Okaya RHCA-301Q43U Datasheet

RHCASERIES
SURGE PROTECTORS
●RHCA Series (4532)
・Surge current capacity 2000A 8/20μs
・Surface Mounted Gas Arrester
・Micro-Gap Design
・Applications:
・CATV modem
・Telecom, xBase T, Hab Protection
・Security Systems
・Data Acquisition
・Audio Systems
●Surge Absorption Characteristics at EN61000-4-5
0.5kV/div
Peak:3kV
10μsec/div
0.5kV/div
0.5kV/div
Break down
Voltage 400V
2kV/div
1.2/50μs,4kV Surge Wave form
RHCA-201Q43U Break down Voltage
10μsec/div
1μsec/div
Electrical Specifications
Test
Model
B
U
B
RHCA-301Q43
U
B
RHCA-351Q43
U
B
RHCA-401Q43
U
RHCA-201Q43
DC spark-over
Voltage
Insulation
Resistance
Electrostatic
Capacitance
Surge
Current
CapaClty
Impulse
Withstanding
Voltage capaclty
200V
(140∼260)
300V
(210∼390)
350V
(245∼455)
400V
(280∼520)
100MΩ Min.
(DC100V)
0.6pF Max.
(1MHz-1V)
8/20μs
2000A
10/700μs 3kV
Positive/Negative
5 times each
Part number system
RCCA
Series
201
DC spark-over
Voltage
201:20×101=200V
Q
Tolerance
P
±20%
Q
±30%
76
43
Size
43
4.5(L)×3.2(W)
U
Packing form
U
Taping
B
Bulk
XXXXXSERIES
SURGE PROTECTORS
●Recommended land pattern
Dimensions [mm]
Reflow soldering
Flow soldering
a
2.7
2.9
b
6.5 to 8.5
6.5 to 9.5
C
3.4
3.6
A
3.6±0.2
B
4.9±0.2
W
12.0±0.3
F
5.5±0.05
D0
φ1.5
D1
φ1.65±0.15
t1
0.30±0.1
t2
3.0±0.2
+0.1
-0
E
1.75±0.1
P1
8.0±0.1
P2
2.0±0.05
[ mm ]
P0
4.0±0.1
●Reel Dimensioning
Minimum Quantity:3000
[mm]
A
φ330±2
B
φ80±0.5
C
φ13.0±0.5
D
φ21士0.8
E
2.0士0.5
77
W
13.5 +1.0
-0.5
t
1.6±0.5
r
1.0
SURGE ABSORBERS
●Plastic Tape Dimensioning