XA,XAB SERIES 250Vac(VDE)

XA,XAB SERIES
SPARK QUENCHER
Features
 Applies to American, Canadian and German
applications.
Safety Agency : Standard
UL
:UL60384-14
cUL
:CSA E60384-14
CSA
:C22.2 No.1
VDE
:IEC/EN 60384-14
Applications
File No.
E47474(Except XAB1202)
E47474(Except XAB1202)
LR37404, LR68886(Except XAB1202)
128473(Except XAV series)
 Suppressing noise occuring Automatic machines
and Office appliances.
XA Series
XAB Series
T±0.5
T±0.5
Dimensions
W±0.5
15min H±0.5
H±0.5
W±0.5
F±1
10±2
F±1
*100±10
0.6±0.05
Soldering
UL-1007,CSA TR-64(AWG20)
Circuit
*200 & 300 available
Unit: mm
Electrical Specifications
Rated Voltage
Dimension
Safety
Agency Class
X2
Model
Number
Capacitance Resistance
μF±20%
XA120033
0.033
XA1201
0.1
XAB1201
0.1
XAB1202
0.2
Ω±30%
120(1/4W)
120(1/2W)
W
H
T
Pulse condition (Max.)
F
Peak to
peak
17.0 14.0 7.0 15.0
17.5
20.0 16.5
700V
18.0 21.5 8.5 15.0
max
19.0 23.0
125Vac(UL, CSA), 250Vac(VDE)
Pulse
width
Max.
20msec.
50msec.
Repetitive
frequency
Pulse width Peak
Pulse
(sec) x
Frequency Voltage
(Hz)
120(60)Hzmax
3(0.8)max
120Hz max
3max
700V
Test
Voltage
Insulation
Resistance
Line to Line
Line to Line
1200Vrms
15,000MΩmin
50/60Hz 2∼5sec Line to Case
Line to Case
100,000MΩmin
2000Vrms
(at 500Vdc)
50/60Hz 60sec
Operating Temperature: -40~+85℃