XA,XAB SERIES SPARK QUENCHER Features Applies to American, Canadian and German applications. Safety Agency : Standard UL :UL60384-14 cUL :CSA E60384-14 CSA :C22.2 No.1 VDE :IEC/EN 60384-14 Applications File No. E47474(Except XAB1202) E47474(Except XAB1202) LR37404, LR68886(Except XAB1202) 128473(Except XAV series) Suppressing noise occuring Automatic machines and Office appliances. XA Series XAB Series T±0.5 T±0.5 Dimensions W±0.5 15min H±0.5 H±0.5 W±0.5 F±1 10±2 F±1 *100±10 0.6±0.05 Soldering UL-1007,CSA TR-64(AWG20) Circuit *200 & 300 available Unit: mm Electrical Specifications Rated Voltage Dimension Safety Agency Class X2 Model Number Capacitance Resistance μF±20% XA120033 0.033 XA1201 0.1 XAB1201 0.1 XAB1202 0.2 Ω±30% 120(1/4W) 120(1/2W) W H T Pulse condition (Max.) F Peak to peak 17.0 14.0 7.0 15.0 17.5 20.0 16.5 700V 18.0 21.5 8.5 15.0 max 19.0 23.0 125Vac(UL, CSA), 250Vac(VDE) Pulse width Max. 20msec. 50msec. Repetitive frequency Pulse width Peak Pulse (sec) x Frequency Voltage (Hz) 120(60)Hzmax 3(0.8)max 120Hz max 3max 700V Test Voltage Insulation Resistance Line to Line Line to Line 1200Vrms 15,000MΩmin 50/60Hz 2∼5sec Line to Case Line to Case 100,000MΩmin 2000Vrms (at 500Vdc) 50/60Hz 60sec Operating Temperature: -40~+85℃