Data Sheet - Carlton

Series T
• Triac output SSRs; Output rated from 10A to 25A @ 24-240 VAC
• AC or DC control
• Zero-crossing (resistive loads) output
PRODUCT SELECTION
Control Voltage
3-32 VDC
90-280 VAC
3-32 VDC
90-280 VAC
10A
25A
TD1210
TA1210
TD2410
TA2410
TD1225
TA1225
TD2425
TA2425
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current (3) [Arms]
Minimum Load Current [mArms]
Maximum Surge Current (16.6ms) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I2 t for Fusing (8.3 msec) [A2 sec]
Minimum Power Factor (with Maximum Load)
10A
25A
10A
25A
24-140
400
8
200
10
40
120
1.6
1.48
60
24-140
400
8
200
25
40
250
1.6
1.02
260
24-280
600
10
200
10
40
120
1.6
1.48
60
24-280
600
10
200
25
40
250
1.6
1.02
260
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Turn-On Voltage
Minimum Turn-Off Voltage
Maximum Reverse Voltage
Typical Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
TDxxxx
TAxxxx
3-32 VDC
3.0 VDC
1.0 VDC
-32 VDC
3.4 mA @ 5 VDC, 20 mA @ 28 VDC
1500 Ohm
1/2 Cycle
1/2 Cycle
90-280 VAC
90 Vrms
10 Vrms
2 mA @ 120 Vrms, 4 mA @240 Vrms
60 K Ohm
10
40
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
Terminals
Recommended Terminal Screw Torque Range:
Parameters
4000 Vrms
109 Ohm
8 pF
-40 to 80°C
-40 to 125 °C
3.0 oz (86.5g)
Thermally conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
6-32 Screws - 10 in lbs. 8-32 Screws - 20 in. lbs. (Screws dry without grase)
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Heat sinking required, for derating curves see page 2
MECHANICAL SPECIFICATIONS
THERMAL DERATE INFORMATION
AGENCY APPROVALS
UL E116949
CSA LR81689
VDE 10143 UG
Rev. 090712
ANNEX - ENVIROMENTAL INFORMATION