BEU Applications Requirement Worksheet

May 6, 2008
Application Requirements Form
Battery Electronics Units
Lithium Ion Battery Balancing, Monitoring,
And Cell Bypass Device Drivers
Rev A
AEROFLEX PLAINVIEW SALES & MARKETING
Prepared by
AEROFLEX PLAINVIEW
35 South Service Road
Plainview, NY 11803
Requirements Worksheet: Battery Electronics Units
Introduction
The Battery Electronics Unit Application Requirements Worksheet
provides a concise format to assist in defining your battery
system’s cell balancing and health monitoring needs.
Completing the worksheet will serve several purposes. You will
have a better understanding of the functional and electrical
features of Aeroflex’s BEU capabilities, it will raise specific
questions pertaining to your application that may not be
covered by the questionnaire, and most importantly, it will
give Aeroflex Engineering and Sales departments a good
understanding of your system needs. This will ultimately result
in very efficient responses to your technical questions and
proposal requests.
Aeroflex Plainview, Sales and Marketing
Completed by:
Date:
Customer Information
Company Name:
Location:
Technical Contact Name:
Technical Contact Phone:
Technical Contact Email:
Application
Program Name:
Application Description:
Target System:
Delivery Needs
Military
Space
Qty
Lab
Date
Prototypes (EM):
Flight product:
Launch Date:
Rev A
2
www.aeroflex.com
Requirements Worksheet: Battery Electronics Units
Balancing Characteristics
Example
Battery Technology
Lithium-Ion
Battery Configuration
8s1p
Battery A-h Capacity
100 A-h
Balancing Accuracy
10 mV
Maximum Desired Balancing Current
1 ampere
Desired balancing current for a voltage
imbalance of 100mv
100 ma
Transfer Ratio ( Cell to Share Bus )
1 ohm
Example
BEU Operating Voltage
Input Voltage Range (With Limits)
Requirement
Requirement
28 V ± 6 V
Voltage Monitoring
Example
Requirement
Total Battery Voltage Accuracy
0.3% of Full Scale
Individual Cell Voltage Accuracy
BOL
Monitor Output Voltage Telemetry
Interface Format
1553 Data Bus
Spacewire
CAN Bus
RS-485 Serial
Discrete Analog Voltages
Other (Specify)
mV
EOL
mV
Discrete Output Thresholds
Low Cell
Volts
High Cell
Volts
OVP (Overvoltage Protection)
Volts
Mechanical Requirements
Standard Product BEU Configuration?
No
Yes
Example
Size
Requirement
5” x 5” x 11”
Weight
Rev A
BEU Series:
8 pounds
3
www.aeroflex.com
Requirements Worksheet: Battery Electronics Units
Radiation Performance Requirements
Total Dose
Example
> 100 krads(Si)
Single Event Latchup
Single Event Upset
Requirement
Immune
Recoverable
ELDRS
Neutron Fluence
Prompt Dose
LET
80 Mev
Example
Environmental Conditions
Temperature Range of Battery
Temperature Range of BEU
-20ºC to +70ºC
Orbit
LEO
Mission Life
8 years
Vibration Level
10 Grms
EMI
Pyroshock
Optional Features
Dual Redundant Balancing
Cell Bypass Relays
Reconditioning Load Control
Temperature Sensor Conditioning (for
temperature sensors located in the
battery)
Requirement
0ºC to +50ºC
MIL-STD-461C
Yes
No
Yes
Yes
Yes
Yes
No
No
No
No
Other(Please Specify)
Rev A
4
www.aeroflex.com
Requirements Worksheet: Battery Electronics Units
Additional Requirements:
Rev A
5