B40SR12424A/B/C/D/DP

B40SR12424A/B/C/D/DP
12V Output DC/DC Converter, Box Type Package
FEATURES

Wide input voltage range, 18~60V

200W Output @ 18V~27V Vin range(for A/B/C/D)

300W Output @ 27~60V Vin range (for A/B/C/D)

300W Output @ 18V~60V Vin range(for DP)

Full Load Efficiency up to 88.3% @48Vin

Intergrated fuse holder

Parallel Connection of multiple units

Box type package with metal base plate

Package Dimension:

190.0x76.0x43.5mm (7.48”x2.99”x1.71”)
Operating Temperature Range - 40°C to +75°C

Input Reverse Polarity Protection

Minimized Inrush current

Input UVLO, Output OCL, Short circuit protection,
OVP, OTP

Enable on/off (option)

2250VDC Isolation

IP67 Protection

RoHs Compliant

ISO 9001, ISO 14001 certified manufacturing facility

UL60950

CE Mark

EMC compatible: EN12895, CISPR11 ClassA

Electrical transient conduction: ISO7637-2
The B40SR12424, a wide input voltage range of 18~60V, and single isolated output converter, is the latest product offering from a world
leader in power systems technology and manufacturing ― Delta Electronics, Inc. Such box type DCDC converter can provide 300W (200W at
Vin < 27V for A/B/C/D), 12.4V regulated DC output voltage with full load efficiency up to 88.3% @48Vin; The B40SR12424 offers input UVLO,
output over current limit, short circuit, output over voltage, over temperature, and input reverse polarity protections, It has an intergrated fuse
holder. It also has parallel function; and allows a wide operating temperature range of –40°C to +75°C. With creative design technology and
optimization of component placement, this converter possess outstanding electrical and thermal performance, as well as high reliability under
extrmely harsh operating conditions. The B40SR12424 meet IP67 protection(not include the connector and fuseholder for A/C/D/DP version).
Input Characteristics
Item
Condition
Continuous Input Voltage
Max Input voltage
Min.
Typ.
Max.
Unit
18
48
60
VDC
80
VDC
10 minutes, normal operating
Input Under-Voltage Lockout, Turn-On
Voltage Threshold
16
17
18
VDC
Input Under-Voltage Lockout, Turn-Off
Voltage Threshold
14
15
16
VDC
1
2
3
VDC
Vin=18V, 100% Load(for A/B/C/D)
12.6
13.1
A
Vin=18V, 100% Load(for DP)
18.8
19.5
A
Vin=24V
100
150
mA
Vin=36V
55
80
mA
Vin=48V
40
70
mA
Lockout Hysteresis Voltage
Maximum Input Current
No-Load Input Current
Reflected input ripple current
0.2
A
Max Reverse Polarity Input Voltage
60
VDC
Max Inrush current
10
A
Internal Input Fuse
DS_B40SR12424_10242013
Vin=48V, Vpp
Ø 6.35mm*31.75mm
250V/30A Fast-acting fuse
E-mail [email protected]
http://www.deltaww.com/dcdc
P1
Output Characteristics
Item
Operating Output Current Range
Output Voltage Set Point
Output Voltage Ripple and Noise,
Output Current Limit
Current share accuracy
Start-up time
Rise time
Output Voltage Protection
Conditions
Vin=18V~27V(for A/B/C/D)
Vin=27V~60V(for A/B/C/D)
Vin=18V~60V(for DP)
Vin=24V,36V,48V, Io=0
Vin=24V, Io=16A(for A/B/C/D)
Vin=24V, Io=24A(for DP)
Vin=36V,48V, Io=24A
Vin=36V, 48V, peak to peak,
20MHz bandwidth
RMS
Vin=24V, peak to peak,
20MHz bandwidth
RMS
Vin=24V (for A/B/C/D)
Vin=24V (for DP)
Vin=36V, 48V
Vin=36V, 48V, 24A for each module
16.5
25
25
13
Vin=24V, 8A to 12A load dynamic, 0.1A/us
slew rate(for A/B/C/D)
Output Voltage Current Transient, positive Vin=24V, 12A to 18A load dynamic, 0.1A/us
slew rate(for DP)
and nagetive voltage step
Vin=36V,48V, 12A to 18A load dynamic,
0.1A/us slew rate
Maximum Output Capacitance
ESR>10mohm
Output overshoot
Efficiency @ 100% Load(16A)
Vin=24V(for A/B/C/D)
Efficiency @ 100% Load(24A)
Vin=24V(for DP)
Efficiency @ 100% Load(24A)
Vin=36V
Efficiency @ 100% Load(24A)
Vin=48V
Efficiency @ 60% Load(9.6A)
Vin=24V(for A/B/C/D)
Efficiency @ 60% Load(14.4A)
Vin=24V(for DP)
Efficiency @ 60% Load(14.4A)
Vin=36V
Efficiency @ 60% Load(14.4A)
Vin=48V
General Characteristics
Item
Conditions
Input to Output, Input to Case
Ouput to Case
Isolation Voltage,
Isolation Resistance, Input to Output
Isolation Capacitance, Input to Output
Switching Frequency
MTBF
Weight
Min.
0
0
0
12.4
12.13
12.0
12.0
Water Protection Level
Vibration
Shock
Emission
Immunity
ESD
DS_B40SR12424_10242013
12.6
12.33
12.2
12.2
Max.
16
24
24
12.8
12.53
12.4
12.4
Unit
A
A
A
V
V
V
V
150
250
mV
35
60
mV
100
150
mV
30
18.5
28
28
6
800
130
15
50
20.5
31
31
10
1200
200
17
mV
A
A
A
%
mS
mS
V
150
250
mV
160
260
mV
150
250
mV
5000
3
µF
%
%
%
%
%
%
%
%
%
Max.
2250
550
Unit
VDC
VDC
MΩ
pF
KHz
Mhours
g
Max.
+125
+75
94
Unit
℃
℃
℃
℃
% rel. H
86.8
86.5
86.5
86.3
87.6
88.2
87.8
87.3
88.8
88.5
88.5
88.3
89.6
90.2
89.8
89.3
Min.
Typ.
10
6000
175
2.8
900
Ta=25ºC, 80%load
Environmental Specifications
Parameter
Storage Temperature Range
Operating Temperature Range
Maximum permitted meta plate temperature
Over Temperature Protection
Humidity (non condensing)
Typ.
Conditions
Ambient Temperature
Vin=48V, Io=24A, Refer to figure25
NTC Temperature
Min.
-40
-40
118
95
Without connector&fuseholder for A/C/D/DP
version
IEC 60068-2-6
IEC 60068-2-27
EN12895
EN12895, EN61000-4-3
EN12895, EN61000-4-2
IP67
10G/15~200HZ/3 PLANES
50G 3 PLANES
30-1000MHz 34-45dBuV/m
10V/m /27-1000MHz AM; 10V/m /900MHz PM
Direct: ±2KV ±4KV; Air: ±2KV ±4KV ±8KV
E-mail [email protected]
http://www.deltaww.com/dcdc
P2
Notes
1
2
Specifications typical at Ta=+25℃, nominal input voltage and rated full load output current unless otherwise noted.
Specifications are subject to change without notice.
ELECTRICAL CURVES
Figure 1: Efficiency vs. Output current
@ Vin=24V,36V,48V (for A/B/C/D)
Figure 2: Loss vs. Output current
@ Vin=24V,36V,48V (for A/B/C/D)
Figure 3: Efficiency vs. Output current
@ Vin=24V,36V,48V (for DP)
Figure 4: Loss vs. Output current
@ Vin=24V,36V,48V(for DP)
DS_B40SR12424_10242013
E-mail [email protected]
http://www.deltaww.com/dcdc
P3
ELECTRICAL CURVES
Figure 5: Dynamic response to load step 12A~18A with
0.1A/uS slew rate at 48Vin
CH1:VOUT, 100mV/div, 500uS/div
Figure 6: Vout start up with Vin on at 48Vin,24A Iout,
TOP:VIN, 20V/div, 200mS/div
BOTTOM: VOUT, 5V/div, 200mS/div
Figure 7: Output ripple & noise at 48Vin, 24A Iout
CH1:VOUT, 50mV/div, 5uS/div
Figure 8: Output over voltage protection at 48Vin, 24A Iout
CH1:VOUT, 10V/div, 50mS/div
Figure 9: Input current vs. Input voltage
@ Vin=18V~27V, 200W;
Vin=27V~60V, 300W(for A/B/C/D)
Figure 10: Output voltage vs. Output current
OCL Performance( for A/B/C/D)
DS_B40SR12424_10242013
E-mail [email protected]
http://www.deltaww.com/dcdc
P4
ELECTRICAL CURVES (continous)
Figure 11: Input current vs. Input voltage
@ Vin=18V~60V, 300W (for DP)
Figure 12: Output voltage vs. Output current
OCL Performance (for DP)
Figure 13: Output voltage vs. Output current
@Vin=48V. Droop function.
Figure 14: Current share accuracy vs. Total output current
2 in parallel.
Figure 15: Inrush current @ Vin=48V
CH1:Iin, 2A/div, 200nS/div
Max current 2.7A, I2t=1.24E-7 A²S
DS_B40SR12424_10242013
E-mail [email protected]
http://www.deltaww.com/dcdc
P5
FEATURES DESCRIPTIONS
Output Over-Current Limit and Short Protection
The modules include internal output over-current limit (OCL) and short circuit protection (SCP) circuits, the
OCL set point is lower than that of the SCP; The response of SCP circuit is much fast than that of the OCL
circuit. The slowly increase of the output current will let module enter OCL protection when the current exceeds
the OCL set point, while the fast increase of the output current will let module enter SCP when the current
exceeds the SCP set point.
When the modules enter OCL protection, the output voltage will decrease while the output current is kept
constant, the output voltage will soft start to set point when the overload condition is removed.
The module will enter hiccup mode when it triggers the SCP set point. The module will try to restart after
shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue
until the overload condition is removed.
Output Over-Voltage Protection
The power module includes an internal output over-voltage protection(OVP) circuit, which monitors the voltage
on the output terminals. If this voltage exceeds the OVP set point, the module will shut down, and then restart
after a fixed delay time (hiccup mode), please refer to figure8 for detail.
Over-Temperature Protection
The over-temperature protection consists of circuitry that provides protection from thermal damage. If the
temperature exceeds the preset temperature threshold the module will shut down,and all components will not
exceed their absolute maximum temperature ratings.The module will restart after the temperature is within
specification.
Remote On/Off
B40SR12424C has Enable control function. This Enable PIN is designed on the primary side of converter, the
converter will turn on when the Enable PIN connected to VIN+, and turn off when the Enable PIN connected to
VIN- or floating.
B40SR12424C
Enable
VIN+
VINVo+
Vo-
Figure 16: suggested Enable connection
Input Reverse Voltage Protection
The input reverse voltage protection is provided by an diode on the input line, the standoff voltage for the
reverse protection shall be no less than -60V.
DS_B40SR12424_10242013
E-mail [email protected]
http://www.deltaww.com/dcdc
P6
DESIGN CONSIDERATIONS
Parallel connection of multiple units
Two units parallel operation is verified, please contact Delta if more than two units need to be paralleled.
While parallelling multiple units, the impedance of the cables from unit to junction point of each unit should be
within ±5% of each other.
Unit1
Unit1
Load
Load
Unit2
Unit2
Figure 17: suggested parallel connections
EMC
80
80
70
70
60
60
50
Le ve l in d B米 V/
Le ve l in d B米 V/
The converter has the internal EMI filters and meet the EMC standards EN12895 30-1000MHz
34-45dBuV/m.The test result is showed as below
Conditions: Vin=48V, Io=24A, 10m measure distance
40
30
20
10
0
30M
50
40
30
20
10
50 60
80 100M
200
300
400 500
0
30M
800 1G
50 60
Figure 18: test result(Vertical)
80 100M
200
300
400 500
800
1G
Figure 19: test result(Horizontal)
80
80
70
70
60
60
Le ve l in d B米 V/
Le ve l in d B米 V/
Conditions: Vin=24V, Io=24A, 10m measure distance
50
40
30
50
40
30
20
20
10
10
0
30M
50 60
80 100M
200
300
400 500
Figure 20: test result(Vertical)
DS_B40SR12424_10242013
800 1G
0
30M
50 60
80 100M
200
300
400 500
800 1G
Figure 21: test result(Horizontal)
E-mail [email protected]
http://www.deltaww.com/dcdc
P7
DESIGN CONSIDERATIONS
Fuse replacement
The module has the intergratted the fuse holder, when the fuse needs to be replaced, it can be taked down in an
anticlockwise direction by slotted type screwdrivers .
Recommended fuse replacement P/N:
Littlefuse 0314030.MXP
THERMAL CONSIDERATION
The following figure shows the location to monitor the temperature of base plate. Before customer decides to
use this DCDC converter, a thermal evaluation need to be did to make sure the temperature of base plate is
lower than that read from below thermal curves (Figure18~20 base on different input voltage).
Figure 22: Thermal consideration
DS_B40SR12424_10242013
E-mail [email protected]
http://www.deltaww.com/dcdc
P8
THERMAL CURVE
AOS
Figure 23: Output Current vs. Base Plate temperature @Vin=24V
AOS
Figure 24:
DS_B40SR12424_10242013
Output Current vs. Base Table temperature @ Vin=36V
E-mail [email protected]
http://www.deltaww.com/dcdc
P9
THERMAL CURVE
AOS
Figure 25:
DS_B40SR12424_10242013
Output Current vs. Base Table temperature @ Vin=48V
E-mail [email protected]
http://www.deltaww.com/dcdc
P10
Mechanical Drawing
Mechanical Dimensions
Pin Connections
Pin
Function Description
1
OUTPUT -
2
OUTPUT +
3
INPUT -
4
INPUT +

All dimensions in mm (inches)

Tolerance:X.X±0.5 (X.XX±0.02)

Connector:
MOLEX MINI-FIT SrTM Header
X.XX±0.25 ( X.XXX±0.010)
(MOLEX P/N :42819-4213)
B40SR12424A(C)
Pin
Function Description
1
OUTPUT -
2
OUTPUT +
3
INPUT -
4
INPUT +

All dimensions in mm (inches)

Tolerance:X.X±0.5 (X.XX±0.02)

Connector:
Deutsch DTP Receptacles
X.XX±0.25 ( X.XXX±0.010)
B40SR12424B(C)
DS_B40SR12424_10242013
(DEUTSCH P/N :DTP04-4P)
E-mail [email protected]
http://www.deltaww.com/dcdc
P11
Mechanical Drawing
Mechanical Dimensions
Pin Connections
Pin
Function Description
1
OUTPUT -
2
OUTPUT +
3
INPUT -
4
INPUT +
5
ENABLE

All dimensions in mm (inches)

Tolerance:X.X±0.5
(X.XX±0.02)
X.XX±0.25
( X.XXX±0.010)

B40SR12424C(C)
Connector:
MOLEX
MINI-FIT
Header
SrTM
(MOLEX P/N :42819-5213)
Pin
Function Description
1
OUTPUT -
2
OUTPUT +
3
INPUT -
4
INPUT +

All dimensions in mm (inches)

Tolerance:X.X±0.5
(X.XX±0.02)
X.XX±0.25
( X.XXX±0.010)

B40SR12424D/DP(C)
Connector:
MOLEX
MINI-FIT
Header
SrTM
(MOLEX P/N :42819-4213)
Physical Outline
Case Size
Case Material
DS_B40SR12424_10242013
:
:
190.0x76.0x43.5 mm (7.48”x2.99”x1.71”)
Case: PC; Plate: AL6063
E-mail [email protected]
http://www.deltaww.com/dcdc
P12
Part Numbering System
B
40
S
R
124
24
A
Form
Factor
Input
Voltage
Number
of
Outputs
Product
Series
Output
Voltage
Output
Current
Option Code
BBox
40 –
18V~60V
S–
Single
R–
Regular
124 –
12.4V
24 –
24A
C
Option
Fitting
With
Built-in
fuse
holder
Enable
pin
Sealed
connector
& fuse
holder
Connector Kit
A
YES
NO
NO
1xhousing+ 4 terminals
B
YES
NO
YES
1xhousing+ 4 terminals
C
NO
YES
NO
1xhousing+ 5 terminals
D
NO
NO
NO
1xhousing+ 4 terminals
DP
NO
NO
NO
1xhousing+ 4 terminals
Model List
Input Voltage Range
Input
EFF @48VIN 100%
LOAD
Output
B40SR12424(A\B\C\D)
18V~60V
13.1A
12.4V
24A
88.3%
B40SR12424(DP)
18V~60V
19.5A
12.4V
24A
88.3%
CONTACT: www.deltaww.com/dcdc
USA:
Telephone:
East Coast: 978-656-3993
West Coast: 510-668-5100
Fax: (978) 656 3964
Email: [email protected]
Europe:
Phone: +31-20-655-0967
Fax: +31-20-655-0999
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107
ext 6220~6224
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) years limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its
use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at
any time, without notice.
DS_B40SR12424_10242013
E-mail [email protected]
http://www.deltaww.com/dcdc
P13