Capacitors for Power Electronics Series/Type: B2536* The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product Date of Withdrawal B25360A5127J050 B25360A5157J050 B25360A5686J050 B25360B5127J050 B25360B5157J050 B25360B5686J050 2013-08-23 2013-08-23 2013-08-23 Deadline Last Orders 2013-11-15 2013-11-15 2013-11-15 Last Shipments 2014-04-15 2014-04-15 2014-04-15 EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Ordering Code Substitute Product Date of Withdrawal B25360A5956J050 B25360A6107J040 B25360A6506J040 B25360A6686J040 B25360A6906J040 B25360A7336J080 B25360A7476J080 B25360A1336J100 B25360A1476J100 B25360A1556J100 B25360A7756J080 B25360A5137J050 B25360B5956J050 B25360B6107J040 B25360B6506J040 B25360B6686J040 B25360B6906J040 B25360B7336J080 B25360B7476J080 B25360B1336J100 B25360B1476J100 B25360B1556J100 B25360B7756J080 B25360B5137J050 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 2013-08-23 Deadline Last Orders 2013-11-15 2013-11-15 2013-11-15 2013-11-15 2013-11-15 2013-11-15 2013-11-15 2013-11-15 2013-11-15 2013-11-15 2013-11-15 2013-11-15 Last Shipments 2014-04-15 2014-04-15 2014-04-15 2014-04-15 2014-04-15 2014-04-15 2014-04-15 2014-04-15 2014-04-15 2014-04-15 2014-04-15 2014-04-15 For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at www.epcos.com/sales. Film capacitors – Power Electronic Capacitors General purpose applications B2536* MKP AC HP Construction and general data Metallized polypropylene film capacitors Aluminum case for general purpose applications Oil filling: Castor oil Safety device: Overpressure disconnector, self-healing technology Mounting and grounding: Stud on bottom of aluminum can Cooling: Naturally air-cooled (or forced air cooling) Degree of protection: Indoor mounting Pollution degree: PD4 Characteristics Rated capacitance CN 10 … 150 µF Tolerance ±5% Connection M10 terminals Rated AC voltage VRMS Rated DC voltage VR Repetitive peak voltage Vi Non repetitive peak voltage VS 550 V 640 V 780 V 1000 V 780 V 900 V 1100 V 1400 V 910 V 1060 V 1290 V 1650 V 1800 V 2100 V 2600 V 3300 V Test data Voltage between terminals VTT 1.5 • VRMS, 60 s Voltage between terminals and aluminium canVTC 3000 V ACRMS, 10 s Dissipation factor tan δ (100 Hz) ≤ 1.0 · 10-3 Life test IEC 61071 Life expectancy Up to 100 000 hours for VRMS |ΔC/C| ≤3% FILM P PM Please read Cautions and warnings and Important notes at the end of this document. May 2012 Page 2 of 8 Film capacitors – Power Electronic Capacitors General purpose applications B2536* MKP AC HP Climatic category 40/70/21 Minimum temperature Θmin. –40 °C Maximum temperature Θmax.* +60 ºC Storage temperature Θstg –40 ºC … +85 ºC Maximum hotspot temperature Θhs** +70 ºC Humidity 95% (ttest = 21 days) Maximum altitude 2000 m above sea level *Considering mounting position with terminals to the top. For other mounting position, please request evaluation. **Maximum temperature allowed at the capacitors hot spot Design data Dimensions (d x h) According to specification table Weight approx. According to specification table Impregnation Castor oil, non PCB Fixing Threaded bolt M12 Max. torque M12: 12 Nm Max. torque M10: 10 Nm Mounting position Upright Reference standards IEC 61071 Certification: UL 810-5th edition Dimensional drawing M10 screw terminal FILM P PM Please read Cautions and warnings and Important notes at the end of this document. May 2012 Page 3 of 8 Film capacitors – Power Electronic Capacitors General purpose applications B2536* MKP AC HP Terms and formulas Maximum current Imax The maximum RMS current for continuous operation Maximum peak current î The maximum current amplitude which occurs instantaneously during continuous operation. The maximum peak current (Î) and the maximum rate of voltage rise (dV/dt) max on a capacitor are related as follows: Î = C · (dv/dt)max Maximum surge current Is The admissible peak current induced by a switching or any other disturbance of the system which is allowed for a limited number of times. Is = C · (dv/dt)s Maximum duration: Maximum number of occurrences: 50 ms/pulse 1000 (during load) Series Resistance Rs The series resistance of a capacitor is the result of the resistive losses that occur in the electrodes, in the contacting and in the inner wiring. The series resistance Rs generates the ohmic losses (I2.Rs) in a capacitor, and it is largely independent of frequency. Self-Inductance Lself The self-inductance is produced by the inductance of the terminals and the windings. With Self-Inductance, it is possible to determine the Resonance Frequency. F= 1 2π Lself C FILM P PM Please read Cautions and warnings and Important notes at the end of this document. May 2012 Page 4 of 8 Film capacitors – Power Electronic Capacitors General purpose applications B2536* MKP AC HP Specifications and ordering codes C μF 33 47 68 95 130 150 IMAX A Î kA IS kA D mm H mm Weight kg Ordering code 45 50 50 60 60 60 1.9 1.9 3.8 3.8 5.2 5.2 5.6 5.7 11.6 11.5 15.7 15.8 75 75 75 75 85 85 115 140 195 245 245 270 0.6 0.8 1.1 1.5 1.6 1.7 B25360A5336J050 B25360A5476J050 B25360A5686J050 B25360A5956J050 B25360A5137J050 B25360A5157J050 640 22 33 50 68 90 100 40 45 50 60 60 60 1.5 1.6 3.2 3.3 4.3 4.2 4.5 4.8 9.6 9.8 13.1 12.6 75 75 75 75 85 85 115 140 195 245 245 270 0.7 0.8 1.1 1.4 1.6 1.8 B25360A6226J040 B25360A6336J040 B25360A6506J040 B25360A6686J040 B25360A6906J040 B25360A6107J040 780 15 22 33 47 75 35 40 50 55 60 1.2 1.2 2.6 2.6 3.7 3.6 3.7 7.9 7.9 11.1 75 75 75 75 85 115 140 195 245 270 0.7 0.8 1.1 1.4 1.7 B25360A7156J080 B25360A7226J080 B25360A7336J080 B25360A7476J080 B25360A7756J080 1000 10 20 33 47 55 30 40 50 60 60 1.2 1.5 2.9 4.1 4.3 3.6 5.0 8.7 12.4 12.8 75 75 75 85 85 115 140 245 245 270 0.7 0.8 1.4 1.6 1.7 B25360A1106J100 B25360A1206J100 B25360A1336J100 B25360A1476J100 B25360A1556J100 VRMS 550 FILM P PM Please read Cautions and warnings and Important notes at the end of this document. May 2012 Page 5 of 8 Film capacitors – Power Electronic Capacitors General purpose applications B2536* MKP AC HP Cautions and warnings • In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not be used at all. This applies also in cases of leakage. • To ensure the full functionality of the overpressure disconnector, elastic elements must not be hindered and a minimum space of 12 mm has to be kept above each capacitor. • Check tightness of the connections/terminals periodically. • The energy stored in capacitors may be lethal. To prevent any chance of shock, discharge and short-circuit the capacitor before handling. • Failure to follow cautions may result, worst case, in premature failures, bursting and fire. • EPCOS AG is not responsible for any kind of possible damages to persons or things due to improper installation and application of capacitors for power electronics. Safety • Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property damage may result from bursting of the capacitor or from expulsion of oil or melted material due to mechanical disruption of the capacitor. • Ensure good, effective grounding for capacitor enclosures. • Observe appropriate safety precautions during operation (self-recharging phenomena and the high energy contained in capacitors). • Handle capacitors carefully, because they may still be charged even after disconnection. • The terminals of capacitors, connected bus bars and cables as well as other devices may also be energized. • Follow good engineering practice. Thermal load After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not exceeded at extreme service conditions. Mechanical protection The capacitor has to be installed in a way that mechanical damages and dents in the aluminum can are avoided. Storage and operating conditions Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas, acid, alkali, salt or the like are present. In dusty environments regular maintenance and cleaning especially of the terminals is required to avoid conductive path between phases and/or phases and ground. The maximum storage temperature is 85 °C. FILM P PM Please read Cautions and warnings and Important notes at the end of this document. May 2012 Page 6 of 8 Film capacitors – Power Electronic Capacitors General purpose applications B2536* MKP AC HP Overpressure disconnector To ensure full functionality of an overpressure disconnector, the following must be observed: 1. The elastic elements must not be hindered, i.e. – connecting lines must be flexible leads (cables). – there must be sufficient space for expansion above the connections. – folding crimps must not be retained by clamps. 2. Stress parameters of the capacitor must be within the IEC61071 specification. Service life expectancy Electrical components do not have an unlimited service life expectancy; this applies to self-healing capacitors, too. The maximum service life expectancy may vary depending on the application the capacitor is used in. FILM P PM Please read Cautions and warnings and Important notes at the end of this document. May 2012 Page 7 of 8 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CeraLink, CSMP, CSSP, CTVS, DeltaCap, DigiSiMic, DSSP, FilterCap, FormFit, MiniBlue, MiniCell, MKD, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 8 of 8