Brick™ Fuses 6125TD Series, Time Delay Description • Time Delay surface mount fuse • Complies with EIA-IS-722 Standard • Solder Immersion Compatible RoHS 2002/95/EC ELECTRICAL CHARACTERISTICS % of Amp Rating Opening Time 4 Hours Minimum 100% 1 Second Minimum 200% 2-4 Seconds Typical 200% 200% 60 Seconds Maximum Agency Information • UL Recognition Guide & File numbers: JDYX2 & E19180. • CSA Component Acceptance: 053787 C 000 & Class No: 1422 30. Environmental Data • Life Test: MIL-STD-202, Method 108A, Test Condition D • Load Humidity: MIL-STD-202, Method 103B • Moisture Resistance: MIL-STD-202, Method 106E • Thermal Shock: MIL-STD-202, Method 107D, air-to-air • Case Resistance: EIA/IS-722 • Resistance to Dissolution of Metallization: ANSI J-STD-002, Test D • Mechanical Shock: MIL-STD-202, Method 213B, Test Condition A • High Frequency Vibration: MIL-STD-202, Method 204D, Test Condition D • Resistance to Solvents: MIL-STD-202, Method 215A Ordering • Specify packaging and product code (i.e., TR1/6125TD500-R) Dimensions mm ⁄(inches) Land Pattern 2.6 3.0 (0.102) (0.118) 4.0 (0.157) 8.6 (0.338) Soldering Method • Wave Immersion: 260°C, 10 sec max. • Infrared: 260°C, 30 sec max. SPECIFICATIONS Product Code Current Rating 6125TD500-R 6125TD750-R 6125TD1-R 6125TD1.5-R 6125TD2-R 6125TD2.5-R 6125TD3-R 6125TD3.5-R 6125TD4-R 6125TD5-R 6125TD7-R 500mA 750mA 1A 1.5A 2A 2.5A 3A 3.5A 4A 5A 7A Voltage Rating AC DC 125V 60V 125V 60V 125V 60V 125V 60V 125V 60V 125V 60V 125V 60V 125V 60V 125V 60V 125V 60V 125V 60V Interrupting Rating* 125VAC 60VDC 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A 50A Resistance (ohms)** Typ. 0.4025 0.2350 0.1680 0.0630 0.0480 0.0350 0.0263 0.0195 0.0185 0.0133 0.0087 Typical Melting I2t† 0.716 1.07 2.88 2.35 9.45 16.2 15.3 14.5 38.8 34.4 90.2 Typical Voltage Drop‡ 245 mV 250 mV 256 mV 125 mV 133 mV 130 mV 97 mV 95 mV 106 mV 100 mV 99 mV * AC Interrupting Rating (Measured at designated voltage, 100% power factor); DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds, battery source) ** DC Cold Resistance (Measured at 10% of rated current) † Typical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current (not to exceed IR), time constant of calibrated circuit less than 50 microseconds) ‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes) Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures. Brick™ Fuses 6125TD Series, Time Delay TIME CURRENT CURVE PACKAGING CODE Packaging Code TR1 Visit us on the web at: www.cooperbussmann.com OC-2530 Rev. M 3/07 © Cooper Electronic Technologies 2007 Description 1000 pieces of fuses on 12mm tape-and-reel on a 7 inch (177mm) reel per EIA Standard 481 North America Cooper Electronic Technologies Cooper Bussmann 1225 Broken Sound Parkway NW P.O. Box 14460 Suite F St. Louis, MO 63178-4460 Boca Raton, FL 33487-3533 Tel: 1-636-394-2877 Tel: 1-561-998-4100 Fax: 1-800-544-2570 Fax: 1-561-241-6640 Toll Free: 1-888-414-2645 Europe Cooper Electronic Technologies Cooper Electronic Technologies Cooper (UK) Limited Avda. Santa Eulalia, 290 Burton-on-the-Wolds 08223 Leicestershire • LE12 5TH UK Terrassa, (Barcelona), Spain Tel: +44 (0) 1509 882 737 Tel: +34 937 362 812 Fax: +44 (0) 1509 882 786 +34 937 362 813 Fax: +34 937 362 719 Asia Pacific Cooper Electronic Technologies 1 Jalan Kilang Timor #06-01 Pacific Tech Centre Singapore 159303 Tel: +65 278 6151 Fax: +65 270 4160