SMALL DIMENSION (ELECTRONIC) FUSES 1/4” x 1-1/4” Time-Delay Fuses 1/4” x 1” Fast-Acting Fuses MDL Time-Delay MDA Time-Delay AGX Fast-Acting Physical Size: Physical Size: 1/4” x 1-1/4” (6.3mm x 32mm) Construction: Ceramic Tube Nickel-plated Brass End Caps Agency Approvals: UL Listed product meets standard 248-14 UL Listed Card: MDA 2/10-20A (Guide JDYX, File E19180 UL Recognized Card: MDA 25-30A (Guide JDYX2, File E19180) CSA Certification Card: MDA 2/10-15 (Class No. 1422-01) Physical Size: Electrical Characteristics Current Voltage Rating Rating AC 2/10 250V 1/4 250V 1/2 250V 3/4 250V 1 250V 1-1/2 250V 2 250V 2-1/2 250V 3 250V 4 250V 5 250V 6 250V 7 250V 8 250V 10 250V 15 250V 20 250V 25 250V 30 250V Catalog Symbol & Current Ratings 250 Volts AGX-1/500 AGX-2/10 AGX-1 AGX-1/200 AGX-3/16 AGX-1-1/4 AGX-1/100 AGX-1/4 AGX-1-1/2 AGX-1/32 AGX-3/10 AGX-2 AGX-1/16 AGX-3/8 — AGX-1/10 AGX-4/10 — AGX-1/8 AGX-1/2 — 125 Volts AGX-3/4 AGX-4 AGX-7 AGX-2-1/2 AGX-5 — AGX-3 AGX-6 — 32 Volts AGX-8 AGX-15 AGX-25 AGX-10 AGX-20 AGX-30 1/4” x 1-1/4” (6.3mm x 32mm) Construction: Glass Tube Nickel-plated Brass End Caps Voltage Rating: See Below Interrupting Rating: See Below Agency Approvals: UL Listed product meets standard 24814 UL Listed Card: MDL 1/16-8A (Guide JDYX, File E19180) UL Recognized Card: MDL 9-30A (Guide JDYX2, File E19180) CSA Certification Card: MDA 2/10-15 (Class No. 1422-01) Electrical Characteristics Current Voltage AC Interrupting Rating Rating Rating1 AC 250V 125V 32V 1/16 250V 35A 10000A – 1/10 250V 35A 10000A – 1/8 250V 35A 10000A – 3/16 250V 35A 10000A – 2/10 250V 35A 10000A – 1/4 250V 35A 10000A – 3/10 250V 35A 10000A – 3/8 250V 35A 10000A – 1/2 250V 35A 10000A – 3/4 250V 35A 10000A – 1 250V 35A 10000A – 1-1/4 250V 100A 10000A – 1-1/2 250V 100A 10000A – 2 250V 100A 10000A – 2-1/4 250V 100A 10000A – 2-1/2 250V 100A 10000A – 3 250V 100A 10000A – 4 250V 200A 10000A – 5 250V 200A 10000A – 6 250V 200A 10000A – 7 250V 200A 10000A – 8 250V 200A 10000A – 9 32V – – 1000A 10 32V – – 1000A 15 32V – – 1000A 20 32V – – 1000A 25 32V – – 1000A 30 32V – – 1000A 1 Interrupting ratings were measured at 70% - 80% power factor on AC, and at a time constant described in UL 198L. NEW EDISON MDL 46 CROSS REFERENCE OLD EDISON BUSS GOULD BDL MDL GDL LF 313 AC Interrupting Rating1 250V 125V 35A 10000A 35A 10000A 35A 10000A 35A 10000A 35A 10000A 100A 10000A 100A 10000A 200A 10000A 200A 10000A 200A 10000A 200A 10000A 200A 10000A 200A 10000A 200A 10000A 200A 10000A 750A 10000A 1500A 10000A 1500A 10000A 1500A 10000A 1 Interrupting ratings were measured at 70% - 80% power factor on AC, and at a time constant described in UL 198L. NEW EDISON MDA CROSS REFERENCE OLD EDISON BUSS GOULD BDA MDA None LF 326 1/4” x 1” (6.4mm x 25.4mm) Construction: Glass Tube Voltage Rating: See Below Agency Approvals: UL Listed product meets standard 24814 UL Listed Card: AGX 0-7A (Guide JDYX, File E19180) UL Recognized Card: AGX 8-30A (Guide JDYX2, File E19180) CSA Component Acceptance Card (Class No. 1422-01, File 53787) NEW EDISON CROSS REFERENCE OLD EDISON BUSS GOULD LF AGX BGX 362 AGX EGX