high power, low loss ut-390 semi-rigid coax cable

HIGH POWER, LOW LOSS
UT-390 SEMI-RIGID COAX
CABLE ASSEMBLY WITH
7/16 CONNECTORS
UT-390 High Power, Low Loss Semi-Rigid Coaxial Assemblies
Features:
Center Conductor:
SPC (Silver-Plated Solid Copper)
Outer Conductor: Semi-rigid copper
Dielectric:
PTFE (Polytetrafluoroethylene)
Cable Outer Diameter: 0.390” (9.906mm)
Connectors:
Silver-plated brass
Center Pin:
Silver-plated phosphor bronze
Operating Temperature:-40°C to +85°C
Minimum Bend Radius:0.75”
Assembly Length:
60” Max
Electrical Specifications:
Impedance:
50 Ohms
Frequency (7/16 Conn.): Up to 2.1 GHz
Insertion Loss: <0.05 dB/ft at 1 GHz
VSWR:
<1.3 to 2.1 GHz
Voltage Withstanding: 12k VRMS @ 60 Hz
Corona Extinction Volt.: 6k VRMS @ 60 Hz
Nominal Capacitance: 29.0 pF/ft
Velocity of Propagation:70%
Attenuation (dB/ft):
0.03 Max at 500 MHz
*connector loss not included
0.05 Max at 1 GHz
0.13 Max at 5 GHz
0.20 Max at 10 GHz
Power Handling (Watts): 900 Max at 2.1 GHz
(Watts CW at 20 degrees Celsius and Sea level)
Mechanical Specifications:
Connector Durability:
500 connections Minimum
Electrical Test Data Supplied With Each Cable Assembly
Customer Specified Length
7/16 / 7/16 [Straight/Straight]
Part Number
CCUT-MM-390-XX
Description
Low Loss UT-390 Coax Cable, 7/16 Male/Male, Straight/Straight
Length
Inches
Rev.: A
Date: 04-08-14
HIGH POWER, LOW LOSS
UT-390 SEMI-RIGID COAX
CABLE ASSEMBLY WITH
7/16 CONNECTORS
Actual Data Plot PN: CCUT-MM-390-19
0.20
S11 Insertion Loss
0.10
0.00
-0.10
-0.20
-0.30
0
1
2
3
4
5
6
4
5
6
Actual Data Plot PN: CCUT-MM-390-19
1.60
S12 VSWR
1.50
1.40
1.30
1.20
1.10
1.00
0
1
2
3
Rev.: A
Date: 04-08-14