Type SCD IGBT Snubber Capacitor Modules

Type SCD IGBT Snubber Capacitor Modules
High dV/dt Direct Mount IGBT Snubber
Style SCD offers protection against voltage transients in low
to medium current IGBT applications where high dV/dt is
encountered. Connect these capacitors from C1 to E2 on a dual
IGBT module or from P to N on a six-pack module to eliminate
severe voltage transients. Parts ending with Z25 fit IGBTs with
23mm, 25mm and 28mm lead spacing. If you have a preferred
lead spacing, please specify.
Highlights
Specifications
- High peak & RMS current capability
- Mount directly to the IGBT module
- Low inductance <20nH
- Low loss polypropylene dielectric
- Self healing
- Other terminal spacing and capacitance values available. - We can build to your specs!
- 85 °C ambient temperature
Capacitance Range
0.22 to 4.7 µF
Capacitance Tolerance
±10% (K) standard, ±5% (J) optional
Rated Voltage
600 to 2000 Vdc
Operating Temperature Range
-55 ºC to 85 ºC
Maximum rms Current
Check tables for values
Test Voltage between Terminals @ 25ºC
160% rated DC voltage for 60 s
Test Voltage between Terminals & Case @ 25ºC
3 kVac @ 50/60 Hz for 60 s
Life Test
2000 h @ 85 ºC, 125% rated DC voltage
Life Expectancy
60,000 h @ rated Vdc, 70 ºC
30,000 h @ rated Vac, 70 ºC
RoHS Compliant
Dimensions
Construction Details
W
Max
L
Max
Case Material
Plastic UL94V-0
Resin Material
Dry Resin UL94V-0
Terminal Material
Tin Plated Copper
H
Max
5.0 mm
1.0 mm
14.0 mm
17.3 mm
6.5 x 8.5 mm
7.0 mm
14.0 mm
25.4 mm
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type SCD IGBT Snubber Capacitor Modules
High dV/dt Direct Mount IGBT Snubber
Mounting Across the Bus?
CDE Will Accommodate Your Bus Structure
Dual Snubber Assembly Option
Part Numbering System
SCD
105
K
122
Series
Type
Designation
Capacitance
in pF
Tolerance
Code
Voltage
J = ±5%
601 = 600 Vdc
Z = Standard
22 = 22 mm
K = ±10% 122 = 1200 Vdc
25.4 mm C-C
24 = 24 mm
104 = 0.1 µF
105 = 1 µF
225 = 2.2 µF
202 = 2000 Vdc
A
3
-
25
Internal
Type of
Lug
Lug Spacing
Assembly Section to be Configuration
Code
used
–F
RoHS
Compliant
Indicator
25 = 25 mm
28 = 28 mm
29 = 29 mm
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type SCD IGBT Snubber Capacitor Modules
High dV/dt Direct Mount IGBT Snubber
Note: Other ratings, sizes and performance specification available upon request. Contact us.
Ratings
Irms
Catalog
Part Number
Volts
100 kHz
Cap.
Volts
60 Hz
dV/dt
Ipk
ESR
55 ºC
W
L
H
(µF)
(Vdc )
(Vac)
(V/µs)
(A)
(mΩ)
(Arms)
(mm)
(mm)
(mm)
600 Vdc
SCD474K601A3Z25-F
0.47
600
275
250
118
9
9.2
24.6
47.0
24.1
SCD684K601A3Z25-F
0.68
600
275
250
170
7
11.5
29.0
47.0
26.7
SCD105K601A3Z25-F
1.00
600
275
200
200
5
14.0
29.0
47.0
26.7
SCD155K601A3Z25-F
1.50
600
275
150
225
4
17.1
29.0
47.0
26.7
SCD205K601A3Z25-F
2.00
600
275
150
300
3
20.7
32.3
45.1
35.6
SCD335K601A3Z25-F
3.30
600
400
300
825
5
35.0
38.1
52.1
38.1
SCD475K601A3Z25-F
4.70
600
400
250
1175
4
46.2
46.4
56.5
50.2
SCD474K102A3Z25-F
0.47
1000
275
250
118
11
9.2
24.6
47.0
24.1
SCD474K102D3Z25-F
0.47
1000
500
700
329
8
12.1
29.0
47.0
26.7
SCD684K102A3Z25-F
0.68
1000
275
200
136
7
11.5
29.0
47.0
26.7
SCD684K102D3Z25-F
0.68
1000
500
500
340
7
14.4
29.0
47.0
26.7
SCD105K102A3Z25-F
1.00
1000
275
200
200
4
14.0
29.0
47.0
26.7
SCD105K102D3Z25-F
1.00
1000
500
400
400
5
17.5
29.0
47.0
26.7
SCD155K102A3Z25-F
1.50
1000
275
160
240
4
17.9
32.3
45.1
35.6
SCD155K102D3Z25-F
1.50
1000
500
400
600
3
22.4
34.8
45.1
35.6
SCD205K102A3Z25-F
2.00
1000
275
160
320
4
20.9
34.8
45.1
35.6
SCD205K102D3Z25-F
2.00
1000
500
400
800
5
26.2
38.1
52.1
38.1
1000 Vdc
1200 Vdc
SCD224K122A3Z25-F
0.22
1200
500
650
143
19
7.9
24.6
47.0
24.1
SCD334K122A3Z25-F
0.33
1200
500
650
215
13
10.0
29.0
47.0
26.7
SCD474K122A3Z25-F
0.47
1200
500
500
235
10
12.0
29.0
47.0
26.7
SCD684K122A3Z25-F
0.68
1200
500
500
340
7
15.1
32.3
45.1
35.6
SCD105K122A3Z25-F
1.00
1200
500
500
500
5
18.5
34.8
45.1
35.6
SCD155K122A3Z25-F
1.50
1200
500
400
600
4
23.9
38.1
52.1
38.1
SCD205K122A3Z25-F
2.00
1200
500
400
800
4
30.1
46.4
56.5
50.2
SCD305K122C3Z25-F
3.00
1200
500
400
1200
5
39.7
76.2
62.9
38.1
SCD224K162A3Z25-F
0.22
1600
500
650
143
19
7.9
24.6
47.0
24.1
SCD334K162A3Z25-F
0.33
1600
500
650
215
12
10.0
29.0
47.0
26.7
SCD474K162A3Z25-F
0.47
1600
500
650
306
10
12.6
32.3
45.1
35.6
SCD684K162A3Z25-F
0.68
1600
500
650
442
7
15.3
34.8
45.1
35.6
SCD105K162A3Z25-F
1.00
1600
500
500
500
6
19.5
38.1
52.1
38.1
SCD155K162A3Z25-F
1.50
1600
500
400
600
5
25.6
41.9
68.6
38.1
SCD205K162A3Z25-F
2.00
1600
500
400
800
5
30.6
44.5
66.7
46.4
SCD224K202A3Z25-F
0.22
2000
500
176
19
8.2
24.6
47.0
24.1
1600 Vdc
2000 Vdc
800
SCD334K202A3Z25-F
0.33
2000
500
800
264
13
10.5
32.3
45.1
35.6
SCD474K202A3Z25-F
0.47
2000
500
600
282
10
13.0
34.3
55.9
30.5
SCD684K202A3Z25-F
0.68
2000
500
600
408
8
16.1
38.1
52.1
38.1
SCD105K202A3Z25-F
1.00
2000
500
600
600
6
21.3
46.4
56.5
50.2
Note: Modify Catalog Part Number to specify lead spacing. Example: 44mm spacing would use –44 instead of Z25. Other capacitance values and lead orientations are
available. Contact us.
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data
(collectively, the “Information”) in this datasheet or other publication are subject to change. The customer
is responsible for checking, confirming and verifying the extent to which the Information contained in this
datasheet or other publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without any guarantee, warranty, representation
or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based
on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has
of operating conditions that such Cornell Dubilier company regards as typical for such applications, but
are not intended to constitute any guarantee, warranty or representation regarding any such matter – and
Cornell Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning
the suitability for a specific customer application, use, storage, transportation, or operating environment.
The Information is intended for use only by customers who have the requisite experience and capability to
determine the correct products for their application. Any technical advice inferred from this Information or
otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given
gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability
for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality
and safety standards regarding the design and manufacturing of its products, in light of the current state
of the art, isolated component failures may still occur. Accordingly, customer applications which require a
high degree of reliability or safety should employ suitable designs or other safeguards (such as installation
of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the
failure of an electrical component does not result in a risk of personal injury or property damage. Although
all product-related warnings, cautions and notes must be observed, the customer should not assume that all
safety measures are indicated in such warnings, cautions and notes, or that other safety measures may not be
required.