Type RA Angstor® Radial PET Film Capacitors

Type RA Angstor® Radial PET Film Capacitors
The RA style capacitor is constructed in an efficient rugged selfencased size. The non-inductive multilayer metallized polyester film
capacitor features a small size, high dv/dt capability, very low ESR
at high frequency and a self-healing capability. RA type capacitors
are ideal for use in high frequency switching power supplies, noise
suppression, EMI reduction and long-life applications.
Highlights
Specifications
- Efficient size
- Self healing
- Low ESR/ESL
- High dv/dt
- Wave solderable
Capacitance Range (at 1 kHz)
0.1 to 10 µF
Capacitance Tolerance
Standard Tolerance ±10% (K), Optional ±5% (J) or ±20% (M)
Rated Voltage
100, 250, 400, 500 Vdc
Operating Temperature Range
–55 ºC to 125 ºC
Dissipation Factor (at 1 kHZ/25 ºC)
≤1.0%
Insulation Resistance
≥1,000 MΩ x µF - Need not exceed 1,000 MΩ
Test Voltage for 100 Vdc rating: 10 Vdc
Test Voltage for >100 Vdc rating : 100 Vdc
Dielectric Strength
1.6 x rated VDC for 2 seconds max.
Bold P.N.: 1.3 x rated VDC for 2 seconds max.
Self Inductance (typical)
2 to 6 nh
Temperature Range
-55° to +125°C at Rated DC Voltage
Bold P.N.: -55° to +125°C
(derate voltage 1.25% / °C above +85°C)
Life Test:
Apply 1.25 x the rated DC voltage for 1000 hours at +85°C.
After the test, the capacitance, DF, and IR should meet the following:
Capacitance change: ≤ 5.0%
DF will meet the initial specification
Insulation Resistance will meet the initial specification
Moisture Test:
Subject the capacitor to +85°C / 85% RH for 21 days without voltage.
After the test, the capacitance, DF, and IR should meet the following:
Capacitance change: ≤ 7.0%
DF will meet the initial specification
Insulation Resistance ≥ 30% of the initial limit
Long Term Stability :
After 2 years of storage in a standard environment.
Capacitance change: ≤2.0%
Vibration
Mil Std 202 Method 204D
Solder Resistance
260°C, 5 sec.
Capacitance change: ≤ 2.0%
Outline Drawing
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type RA Angstor® Radial PET Film Capacitors
Ratings
Catalog
Part Number
Capacitance
(uF)
224K100RA3-FA
Dimensions (in.)
Dimensions (mm)
d
L
Max.
T
Max.
H
Max.
S
± 0.5
d
Max. dv/dt
(V/us)
0.295
0.025
8.9
3.9
7.1
7.5
0.6
75
0.305
0.295
0.025
8.9
4.6
7.7
7.5
0.6
65
L
Max.
T
Max.
H
Max.
0.22
0.350
0.155
0.280
474K100RA3-FA
0.47
0.350
0.180
S
± 0.02
100 Vdc / 80 Vac
105K100RA4-FA
1.0
0.450
0.175
0.285
0.394
0.025
11.4
4.4
7.2
10
0.6
35
225K100RA3-FA
2.2
0.350
0.250
0.350
0.295
0.025
8.9
6.3
8.9
7.5
0.6
25
225K100RA4-FA
2.2
0.450
0.205
0.285
0.394
0.025
11.4
5.2
7.2
10
0.6
25
335K100RA4-FA
3.3
0.450
0.250
0.350
0.394
0.025
11.4
6.3
8.9
10
0.6
25
405K100RA4-FA
4.0
0.450
0.200
0.380
0.394
0.032
11.4
5.1
9.7
10
0.8
20
505K100RA4-FA
5.0
0.450
0.220
0.480
0.394
0.032
11.4
5.6
12.2
10
0.8
20
106K100RA6-FA
10.0
0.650
0.260
0.460
0.591
0.032
16.5
6.6
11.7
15
0.8
13
104K250RA4-FA
0.10
0.450
0.160
0.255
0.394
0.025
11.4
4.1
6.5
10
0.6
100
224K250RA4-FA
0.22
0.450
0.190
0.305
0.394
0.025
11.4
4.8
7.7
10
0.6
75
250 Vdc / 160 Vac
334K250RA4-FA
0.33
0.450
0.250
0.330
0.394
0.025
11.4
6.3
8.4
10
0.6
75
474K250RA4-FA
0.47
0.450
0.210
0.305
0.394
0.025
11.4
5.3
7.7
10
0.6
55
474K250RA6-FA
0.47
0.650
0.230
0.340
0.591
0.032
16.5
5.8
8.6
15
0.8
50
105K250RA6-FA
1.0
0.650
0.240
0.340
0.591
0.032
16.5
6.1
8.6
15
0.8
35
400 Vdc / 250 Vac
224K400RA6-FA
0.22
0.650
0.230
0.340
0.591
0.032
16.5
5.8
8.6
15
0.8
65
474K400RA6-FA
0.47
0.650
0.290
0.440
0.591
0.032
16.5
7.4
11.1
15
0.8
120
504K500RA6-FA
0.5
0.650
0.280
0.540
16.5
7.1
13.7
15
0.8
120
500 Vdc / 250 Vac
0.591
0.032
Part numbers highlighted in yellow are stocked
Part Numbering System
224
K
100
RA
3
Capacitance
Tolerance
Voltage
Type
Case Size
224 = 0.22 µF
K = ±10%
100 = 100 Vdc
3 = 0.3”=7.5 mm
4 = 0.4”=10 mm
-FA
RoHS
-FA = 6/6 Compliant
w Sn plated wire leads
(Blank = 5/6 compliant
w SnPb wire lead finish)
6 = 0.6”=15 mm
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Type RA Angstor® RadialTypical
PET Film
Capacitors
Performance
Curves
Typical Performance Curves
Selected High Value “Power” Capacitors
3.3 µF 100 VDC RA4
10.0 µF 100 VDC RA6
0.10
Vrms
Irms
0.01
0.001
0.01
Maximum RMS Voltage & Current vs Frequency
c
335K100RA4 (3.3 µF RA4 MLP)
100 Hz
1 KHz
KH
10
0 KHz
KH
100
00 KHz
KH 1 MHz
MH
Frequency
Current (rms)
0.10
1.00
0.10
Vrms
Irms
0.01
0.001
10 MHz
0.001
100 Hz
1000
10.00
10.00
100.0
0.10
Vrms
Irms
0.01
0.001
100 Hz
1.00
Voltage (rms)
100.0
Current (rms)
Voltage (rms)
100.0
0.10
1 KHz
10 KHz
100 KHz 1 MHz
0.01
0.001
100 Hz
0.001
100 Hz
1 KHz
10 KHz
100 KHz 1 MHz
1.00
0.10
0.01
Maximum RMS Voltage & Current vs Frequency
c
105K250RA6 (1.0 µF RA6 MLP)
1 KHz
10 KHz
100 KHz 1 MHz
0.001
10 MHz
Current (rms)
100.0
Voltage (rms)
0.10
10.00
1000
1.00
0.01
Maximum RMS Voltage & Current vs Frequency
c
505K100RA4 (5.0 µF RA4 MLP)
0.001
10 MHz
0.47 µF 400 VDC RA6
Current (rms)
Voltage (rms)
Vrms
Irms
100 KHz 1 MHz
Vrms
Irms
0.10
10.00
0.10
10 KHz
1.00
0.01
0.001
10 MHz
100.0
1.00
1 KHz
10.00
5.0 µF 100 VDC RA4
10.00
Maximum RMS Voltage & Current vs Frequency
c
106K100RA6 (10.0 µF RA6 MLP)
10.00
0.01
Maximum RMS Voltage & Current vs Frequency
c
405K100RA4 (4.0 µF RA4 MLP)
0.10
1.0 µF 250 VDC RA6
4.0 µF 100 VDC RA4
1.00
1.00
0.01
Current (rms)
1.00
10.00
1.00
Voltage (rms)
Current (rms)
Voltage (rms)
10.00
10.00
100.0
10.00
100.0
10.00
1.00
0.10
Vrms
Irms
0.01
0.001
10 MHz
0.001
www.paktron.com
0.10
0.01
Maximum RMS Voltage & Current vs Frequency
c
474K400RA6 (0.47 µF RA6 MLP)
100 Hz
1.00
1 KHz
10 KHz
100 KHz 1 MHz
0.001
10 MHz
PAGE 9
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830
Notice and Disclaimer: All product drawings, descriptions, specifications, statements, information and data
(collectively, the “Information”) in this datasheet or other publication are subject to change. The customer
is responsible for checking, confirming and verifying the extent to which the Information contained in this
datasheet or other publication is applicable to an order at the time the order is placed. All Information given
herein is believed to be accurate and reliable, but it is presented without any guarantee, warranty, representation
or responsibility of any kind, expressed or implied. Statements of suitability for certain applications are based
on the knowledge that the Cornell Dubilier company providing such statements (“Cornell Dubilier”) has
of operating conditions that such Cornell Dubilier company regards as typical for such applications, but
are not intended to constitute any guarantee, warranty or representation regarding any such matter – and
Cornell Dubilier specifically and expressly disclaims any guarantee, warranty or representation concerning
the suitability for a specific customer application, use, storage, transportation, or operating environment.
The Information is intended for use only by customers who have the requisite experience and capability to
determine the correct products for their application. Any technical advice inferred from this Information or
otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given
gratis (unless otherwise specified by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability
for the advice given or results obtained. Although Cornell Dubilier strives to apply the most stringent quality
and safety standards regarding the design and manufacturing of its products, in light of the current state
of the art, isolated component failures may still occur. Accordingly, customer applications which require a
high degree of reliability or safety should employ suitable designs or other safeguards (such as installation
of protective circuitry or redundancies or other appropriate protective measures) in order to ensure that the
failure of an electrical component does not result in a risk of personal injury or property damage. Although
all product-related warnings, cautions and notes must be observed, the customer should not assume that all
safety measures are indicated in such warnings, cautions and notes, or that other safety measures may not be
required.