Specifications, Radial-Leaded, Mica Capacitors Specifications

Specifications, Radial-Leaded, Mica Capacitors
Specifications
Capacitance is within tolerance
when measured at these frequencies:
1–1000 pF @ 1MHz
> 1000 pF @ 1 kHz
Dissipation Factor limits are
below. Dissipation factor is equal
to DF=2πfRC, where f is the test frequency, R is the equivalent series
resistance, and C is the capacitance. For other capacitance values, see Figure 1.
Capacitance
75–1,000 pF
1,100–3,300 pF
3,600–9,100 pF
10,000 pF
Dissipation Factor
0.00075 max at 1 MHz
0.0014 max at 1 kHz
0.0013 max at 1 kHz
0.0012 max at 1 kHz
Quality Factor (Q) is the reInsulation Resistance for capacitances up to 10,000 pF is
greater than 100 GΩ at 25°C and
greater than 10 GΩ at 125°C. For
other capacitance values and temperatures, see Figure 2.
Withstanding Voltage is 2
times the rated voltage, and can be
applied up to 5 seconds without
damage.
sure the capacitors’ capacitance at
25°C, –55°C, 25°C, 125°C (or
150°C) and at 25°C after stabilizing
at each temperature. The capacitance will meet the limits of the
Characteristic table shown in Ordering Information.
Solderability: After an eighthour steam aging, coat leads with
rosin flux (R) and immerse in molten 245°C ± 5°C 60/40 tin/lead solder. Solder coverage will be no less
than 95% when examined at 10X
magnification.
Surge
Voltage: Standard
dipped capacitors will withstand
500 Vdc max peak transients
above rated voltage. For example,
in flyback regulators with less than
500 Vdc bias, you may use 500
Vdc-rated capacitors provided that
the switching transient peaks are
less than 1,000 V.
Voltage Coefficient: The
change in capacitance from 0 volts
to rated voltage is less than 0.1%.
Pulse Handling: Standard
dipped capacitors will withstand
an unlimited number of pulses
with a dV/dt of 100,000 V/µs tested
per IEC 384-1. Smaller capacitance
ratings can withstand even faster
dV/dt—ratings have been tested
one million discharges at rated
voltage into a 4.7Ω resistor with no
change in capacitance. For a 100
pF, 500 Vdc unit, that’s a peak dV/
dt in excess of 1,000,000 V/µs. The
dV/dt is expressed by this relationship:
dV/dt = V
R dC
RV = rated voltage, Vdc
R d = minimum discharge resistor, Ω
dC = rated capacitance, µF
This is the initial rate of discharge
into Rd.
Marking is in accordance with
EIA RS153B and includes “CD” as
our manufacturer’s symbol, nominal capacitance in pF, capacitance
tolerance, and dc working voltage
followed by V, if other than 500
Vdc.
Miniature dipped units (CD6 and
CD7) are marked with capacitance
in pF and tolerance letter designation.
.10
.01
.001
Maximum dissipation factor
at 1 MHz for capacitance
values of 1,000 pF or less
.0001
1
10
Maximum dissipation factor
at 1 kHz for capacitance
values greater than 1,000 pF
100
1,000
10,000
100,000
INSULATION RESISTANCE (MEGOHMS)
MIL-C-5 units (Type CM) are in accordance with MIL-C-5.
DISSIPATION FACTOR
Radial Leaded
Mica Capacitors
ciprocal of dissipation factor.
Temperature Coefficient
and Capacitance Drift: Mea-
100,000
+25°C
+85°C
+125°C
10,000
+150°C
1,000
100
5 10
CAPITANCE (pF)
Figure 1. DF vs. Capacitance
4.016
100
1,000
10,000
62,000
CAPACITANCE (pF)
Figure 2. IR vs. Capacitance
1605 East Rodney French Blvd.
New Bedford, MA 02744
(508) 996-8564, Fax (508) 996-3830
http://www.cornell-dubilier.com
E-mail: [email protected]
CORNELL
DUBILIER
Your Source For Capacitor Solutions
Specifications, Radial-Leaded, Mica Capacitors
Specifications
Moisture Resistance: Capacitors will meet the requirements of
MIL-STD-202, Method 106F as outlined here and diagrammed on the
right. Refer to MIL-STD-202 for details. For miniature Types CD6 and
CD7, use one 24-hour cycle rather
than 10.
1. Dry capacitors for 24 hours in a
50±2°C oven and then allow to
stabilize at room temperature.
2. Subject the capacitors to 10 24hour continuous cycles with
relative humidity and temperature as shown.
3. 24 hours after completion of the
last cycle, the capacitors will
show no visual damage and will
meet the after-test limits below.
Life Test: Subject the capaci-
65±2°C
90–98% RH
8
1–4
3
25±2°C
90–98% RH
2 1⁄2
3
2 1⁄2
hours
2 1⁄2
3
2 1⁄2
–10±2°C
uncontrolled
humidity
with 1.5 times rated voltage applied for 2,000 hours. There will
be no visual damage and the
capacitors will meet the after-test
limits below.
After-Test Limits
Test
Moisture Resistance
Life Test
IL=Initial Limit
Withstand
Voltage
IL
IL
Insulation
Resistance
30 GΩ
IL
Capacitance Change
(whichever is greater)
NV±1% or ±1 pF
NV±1% or ±1 pF
DF
Q
150% IL
150% IL
2/3xIL
2/3xIL
NV=Nominal Value
CORNELL
DUBILIER
Your Source For Capacitor Solutions
1605 East Rodney French Blvd.
New Bedford, MA 02744
(508) 996-8564, Fax (508) 996-3830
http://www.cornell-dubilier.com
E-mail: [email protected]
4.017
Radial Leaded
Mica Capacitors
tors to maximum operating
temperature (+125°C or +150°C)
24-Hour Moisture Resistance Cycle