PRODUCT DATASHEET 1‐800‐383‐7323 USA/CAN www.energizer.com Eveready 1212 AAA SUPER HEAVY DUTY Chemical System: Zinc-Manganese Dioxide (Zn/MnO 2) (No Added Mercury or Cadmium) Industry Standard Dimensions mm (inches) Designation: ANSI-24D, IEC-R03 Battery Voltage: Operating Temp: Average Weight: Volume: Average Capacity: 1.5 Volts -18ºC to 55ºC (0ºF to 130ºF) 9.7 grams (0.31 oz.) 4.0 cubic centimeters (0.2 cubic inch) 540 mAh to 0.8 volts (Rated at 25 mA continuous at 21ºC) One No. 12 (size "AAA") Metal Cell: Jacket: Industry Standard Test (21°C) LIGHTING 5.1 ohm LIF Voltage (CCV) 1.6 1.4 1.2 1.0 0.8 0.0 0.5 1.0 1.5 Service (hours) 2.0 Industry Standard Tests (21°C) RADIO 75 ohm 4 hrs/day REMOTE 24 ohm 15 sec/min 8 hrs/day 1.6 Voltage (CCV) Voltage (CCV) 1.6 1.4 1.2 1.0 0.8 0 5 10 15 20 Service (hours) 25 1.4 1.2 1.0 0.8 0 30 4 6 8 Service (hours) 10 12 TAPE / ELECTRONIC GAMES 10 ohm 1 hr/day PHOTOFLASH 3.6 ohm 24 hrs/day 1.6 Voltage (CCV) 1.6 Voltage (CCV) 2 1.4 1.2 1.0 0.8 0 60 120 180 240 Service (cycles) 300 1.4 1.2 1.0 0.8 0.0 0.5 1.0 1.5 2.0 2.5 Service (hours) 3.0 3.5 Important Notice This data sheet contains information specific to batteries manufactured at the time of its publication. Contents herein do not constitute a warranty. Copyright © Eveready Battery Co. Inc. - All Rights Reserved Form No. EBC - 3108E Page 1 of 1