For more information, please visit the product page. date 09/28/2012 page 1 of 4 SERIES: PTK10 │ DESCRIPTION: DC-DC CONVERTER RoHS PTK10-Q24-S3 input voltage output voltage output current range (Vdc) (Vdc) min (mA) 10 ~ 36 3.3 0.24 output power ripple1 noise1 efficiency max (mA) max (W) max (mVp-p) max (mVp-p) typ (%) 2.4 7.92 75 75 79 in MODEL ue d FEATURES ·industry standard pin out ·wide 4:1 input range ·fully isolated ·over-current protection ·over-voltage protection ·six-sided EMI shielding ·constant switching frequency ·high efficiency ·compact size 2.0”x1.0”x0.4” ·3 year warranty 10 ~ 36 5 10 ~ 36 12 PTK10-Q24-S15 10 ~ 36 15 PTK10-Q24-D5 10 ~ 36 ±5 PTK10-Q24-D5A 10 ~ 36 ±5 0.15/0.05 1.5/0.5 10.0 PTK10-Q24-D12 10 ~ 36 ±12 0.045 0.45 10.8 PTK10-Q24-D15 10 ~ 36 ±15 0.035 0.35 8.5 150 150 83 PTK10-Q48-S3 20 ~ 72 3.3 0.24 2.4 7.92 75 75 78 PTK10-Q48-S15 PTK10-Q48-D5 PTK10-Q48-D5A 2.0 10.0 75 75 82 0.9 10.8 120 120 83 0.07 0.7 10.5 150 150 84 0.1/0.1 1.0/1.0 10.0 100 100 80 100 100 78 120 120 83 20 ~ 72 5 0.2 2.0 10.0 75 75 81 20 ~ 72 12 0.09 0.9 10.8 120 120 84 20 ~ 72 15 0.07 0.7 10.5 150 150 85 20 ~ 72 ±5 0.1/0.1 1.0/1.0 10.0 100 100 81 20 ~ 72 ±5 0.15/0.05 1.5/0.5 10.0 100 100 81 20 ~ 72 ±12 0.045 0.45 10.8 120 120 83 20 ~ 72 ±15 0.035 0.35 10.5 150 150 83 is PTK10-Q48-D12 co PTK10-Q48-S5 PTK10-Q48-S12 0.2 0.09 nt PTK10-Q24-S5 PTK10-Q24-S12 PTK10-Q48-D15 D Notes: 1. All models are also available in an extended temperature range of -40°C~85°C. For these models, append “M” to the model number, 2. Ripple & noise measured with a 20MHz bandwidth, off a 10uF electrolytic and a 0.1uF ceramic cap in parallel at the ouptut. cui.com e.g. PTK10-Q48-S5M. For more information, please visit the product page. CUI Inc │ SERIES: PTK10 │ DESCRIPTION: DC-DC CONVERTER date 09/28/2012 │ page 2 of 4 INPUT parameter conditions/description operating input voltage min typ max units 10 20 24 48 36 72 Vdc Vdc min typ max units OUTPUT conditions/description line regulation (low line to high line) single output dual output ±0.5 ±1.0 % % load regulation measured from 10% to full load single output models - no load to full load dual output models - balanced loads ±1.0 ±2.5 % % voltage accuracy positive, refer to recommended circuit negative, refer to recommended circuit switching frequency constant ±1 ±3 ±3 ±5 PROTECTIONS conditions/description over-current continuous, automatic recovery4 min over-voltage internal protection zener 4 typ % % kHz ±0.03 %/°C max units 105 135 % 110 140 % max units 83 % in parameter ue 300 temperature coefficient Notes: d parameter 4. continuous operation in a protected state may compromise long-term reliability. SAFETY AND COMPLIANCE conditions/description efficiency typical at full load isolation voltage input/case, input/output, output/case 500 Vac insulation resistance at 500 Vdc 100 MΩ RoHS compliant yes MTBF MIL-HDBK-217F 580,000 hours co nt parameter min typ 77 ENVIRONMENTAL parameter case operating temperature conditions/description min regular models - see derating curve extended temperature models is storage temperature non-condensing temperature rise 100% load lead temperature 1.5 mm from the case for 10 seconds D storage humidity typ max units -20 -40 71 85 °C -40 105 °C 5 95 % 40 DERATING CURVES output power vs. ambient temperaure cui.com °C 300 °C For more information, please visit the product page. CUI Inc │ SERIES: PTK10 │ DESCRIPTION: DC-DC CONVERTER date 09/28/2012 │ page 3 of 4 MECHANICAL parameter conditions/description dimensions 2.0 x 1.0 x 0.4 inch (50.8 x 25.4 x 10.16 mm) min case material Zn typ weight max 40 g d MECHANICAL DRAWING Single Output Dual Output 1. +Vin 2. -Vin 1. +Vin 2. -Vin 3. +Vout 4. No pin 5. -Vout 3. +Vout 4. Com 5. -Vout D is co nt in ue units: inches (mm) cui.com units For more information, please visit the product page. CUI Inc │ SERIES: PTK10 │ DESCRIPTION: DC-DC CONVERTER date 09/28/2012 │ page 4 of 4 REVISION HISTORY rev. description date 1.0 initial release 07/07/2011 1.01 updated mechanical drawing 03/27/2012 1.02 discontinued 09/28/2012 D is co nt in ue d The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.