MODEL: PJ-102A │ DESCRIPTION: DC POWER JACK
FEATURES
•
•
•
•
•
2.0 mm center pin
2.5 A rating
right-angle orientation
through hole
tapered pins
SPECIFICATIONS
parameter
conditions/description
min
rated input voltage
typ
rated input current
contact resistance1
between terminal and mating plug
between terminal in a closed circuit
insulation resistance
at 500 Vdc
voltage withstand
at 50/60Hz for 1 minute
any direction for 10 seconds
-25
life
A
50
30
mΩ
mΩ
500
Vac
3
kg
500
g
85
°C
5,000
flammability rating
UL94V-0
RoHS
2011/65/EU
Note:
2.5
MΩ
0.3
operating temperature
units
Vdc
100
insertion/withdrawal force
terminal strength
max
16
cycles
1. When measured at a current of less than 100 mA/1 kHz
SOLDERABILITY
parameter
conditions/description
min
typ
max
units
wave soldering
dipped in solder pot for 5 ±0.5 seconds
255
260
265
°C
cui.com
For more information, please visit the product page.
CUI Inc │ MODEL: PJ-102A │ DESCRIPTION: DC POWER JACK
date 01/08/2015│ page 2 of 3
MECHANICAL DRAWING
units: mm[inches]
tolerance:
X.X ±0.2mm
X.XX ±0.1mm
X.XXX ±0.05mm
MATERIAL
PLATING
center pin
copper
nickel
terminal 1
brass
tin
terminal 2
copper alloy
tin
terminal 3
brass
tin
plastic
PBT
14.4 0.567
9.0 0.354
3.50 0.138
2.0 0.079
6.50 0.256
11.0 0.433
6.50 0.256
3.5 0.138
(TYP)
2
1.00 0.039
(3 PLCS)
3
1
3.0 0.118
4.7 0.185
3.0 0.118
10.7 0.421
1.00X1.60
(3 PLCS)
10.7 0.421
2
3.0 0.118
3
1
4.7 0.185
3.0 0.118
PCB LAYOUT
TOP VIEW
1
3
2
SCHEMATIC
MATING PLUG
Jack Insertion Depth: 9.0 mm
Note:
Model
PJ-102A
Center Pin
Ø2.0 mm
1. All specifications measured at 10~35°C, humidity at 45~85%, under standard atmospheric pressure, unless otherwise noted.
cui.com
For more information, please visit the product page.
CUI Inc │ MODEL: PJ-102A │ DESCRIPTION: DC POWER JACK
date 01/08/2015│ page 3 of 3
REVISION HISTORY
rev.
description
date
1.0
initial release
11/17/2005
1.01
updated contact resistance
06/06/2006
1.02
applied new spec template
01/08/2015
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.