ETSA Datasheet - AC-DC POWER SUPPLY | CUI Inc

For more information, please visit the product page.
date
11/17/2014
page
1 of 8
SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY
18 W power
compact size
universal input (90~264 Vac)
single regulated output from 5~15 V
over voltage and short circuit protection
UL/cUL, GS, PSE safety approvals
level V efficiency
custom designs available
ETSA050360UD
output
voltage
output
current
output
power
ripple
and noise1
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
3.6
18
100
V
5
ETSA060300UD
6
ETSA120150UD
12
ETSA150120UD
15
efficiency
level
3
18
100
V
1.5
18
120
V
1.2
18
150
V
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
O
PART NUMBER KEY
N
Notes:
TI
MODEL
N
U
•
•
•
•
•
•
•
•
ED
FEATURES
D
IS
C
ETSA120150UD X - XX - SZ - CXX
Base Number
Factory
Designation
example of 12 Vdc, 1.5 A
AC Input Plug:
D = IEC 320 C8 plug
DC Plug type:
see output plug options
on page 7
Input Cable:
“Blank” = No Cable
C = North American input cable
2 = European input cable
3 = United Kingdom input cable
4 = Australian input cable
5 = China input cable
6 = South Korea input cable
7 = Brazil input cable
8 = South Africa input cable
9 = Japan input cable
cui.com
Reserved for Custom
Configurations
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/17/2014 │ page 2 of 8
INPUT
conditions/description
min
90
frequency
47
current
115 Vac, cold start
230 Vac, cold start
inrush current
leakage current
no load power consumption
OUTPUT
conditions/description
line regulation
6 V model
all other models
min
PROTECTIONS
N
load regulation
conditions/description
over voltage protection
output voltage clamped by internal protection zener
short circuit protection
output shut down and auto restart
parameter
min
TI
parameter
SAFETY & COMPLIANCE
typ
U
parameter
typ
conditions/description
min
max
units
264
Vac
63
Hz
ED
parameter
voltage
0.5
A
40
80
A
A
0.25
mA
0.3
W
max
units
±1
±5
%
±5
%
typ
typ
max
units
max
units
3,000
4,242
Vac
Vdc
input to output at 10 mA for 1 minute
isolation resistance
input to output at 500 V dc
safety approvals
UL 60950-1, EN 60950-1/IEC 60950-1, PSE
EMI/EMC
FCC part 15 class B, CE, CISPR 22, ICES-003, ANSI C63.4, VCCI, EN 61204-3, EN 55022, EN 55024 EN
61000-3-(2, 3) Class A, EN 55024, IEC 61000-4-(2, 3, 4, 5, 6, 8, 11)
O
RoHS
N
isolation voltage
100
MΩ
2011/65/EU
ENVIRONMENTAL
conditions/description
min
max
units
0
40
°C
storage temperature
-10
70
°C
operating humidity
20
80
%
storage humidity
10
90
%
IS
C
parameter
D
operating temperature
cui.com
typ
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/17/2014 │ page 3 of 8
MECHANICAL
conditions/description
3.173 x 1.969 x 1.220 (80.6 x 50 x 31 mm)
min
input plug
IEC320 / C8
weight
15 V model
all other models
typ
units
inch
105
110
MECHANICAL DRAWING
N
U
units: mm
tolerance: ±1mm
TI
31±1
O
N
50±1
max
ED
parameter
dimensions
D
IS
C
80.6±1
cui.com
g
g
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/17/2014 │ page 4 of 8
DC CORD
U
ED
cord length
MODEL NO.
CABLE GAUGE
CORD LENGTH
ETSA050360UD
18 AWG
1,000 ±100
18 AWG
1,000 ±100
20 AWG
1,530 ±100
ETSA150120UD
20 AWG
1,830 ±100
N
ETSA060300UD
ETSA120150UD
NORTH AMERICAN INPUT CABLE
IS
C
O
N
units: mm
TI
AC CORD
EUROPEAN INPUT CABLE
D
units: mm
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/17/2014 │ page 5 of 8
AC CORD (CONTINUED)
UNITED KINGDOM INPUT CABLE
U
ED
units: mm
AUSTRALIAN INPUT CABLE
IS
C
units: mm
O
CHINA INPUT CABLE
N
TI
N
units: mm
SOUTH KOREA INPUT CABLE
D
units: mm
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/17/2014 │ page 6 of 8
AC CORD (CONTINUED)
BRAZIL INPUT CABLE
U
ED
units: mm
SOUTH AFRICA INPUT CABLE
D
IS
C
units: mm
O
JAPAN INPUT CABLE
N
TI
N
units: mm
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/17/2014 │ page 7 of 8
OUTPUT PLUG OPTIONS
14±0.5
ED
ø3.5 +0/-0.1
ø3.5 +0/-0.1
3.5 mm Phono Plug
14±0.5
*Tip positive
P1
P1R
C
Right Angle PXR
Standard PXX
B
A
O
IS
C
B
N
B
A
C
C
A
B
C
Unit
5.5
2.1
9.5
mm
P6/P6R
5.5
2.5
9.5
mm
P7/P7R
3.5
1.35
9.5
mm
P8/P8R
3.8
1.35
9.5
mm
P9/P9R
3.8
1.05
9.5
mm
TI
Locking DC Plug
EIAJ Plugs
P5/P5R
N
Standard PX
B
A
B
A
C
A
U
Standard DC Plug
A
B
C
Unit
P10
5.5
2.1
9.5
mm
P11
5.5
2.5
9.5
mm
EIAJ
A
B
C
P12/P12R
EIAJ-1
2.35
0.7
P13/P13R
EIAJ-2
4.0
1.7
P14/P14R
EIAJ-3
4.75
1.7
C
Right Angle PXXR
D
Stripped and Tinned
25±5
9±2
D
DC PLUG TYPE
PXX X X
Plug Type:
PXX = See above plug options
ST = Stripped and Tinned
Plug Angle:
“blank” = Straight
R = Right Angle
*Contact CUI for additional plug options
cui.com
Plug Polarity:
P = Center Positive
N = Center Negative
D
Unit
9.5
NA
mm
9.5
5.0
mm
9.5
5.0
mm
For more information, please visit the product page.
CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY
date 11/17/2014 │ page 8 of 8
REVISION HISTORY
rev.
description
date
01/25/2010
initial release
new template applied
1.02
updated P7/P7R B dimension
1.03
V-Infinity branding removed, safety and EMI/EMC data updated
08/21/2012
1.04
updated series/model numbers
11/20/2012
1.05
added ac cord options
ED
1.0
1.01
12/22/2011
03/23/2012
11/17/2014
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.