For more information, please visit the product page. date 11/17/2014 page 1 of 8 SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY 18 W power compact size universal input (90~264 Vac) single regulated output from 5~15 V over voltage and short circuit protection UL/cUL, GS, PSE safety approvals level V efficiency custom designs available ETSA050360UD output voltage output current output power ripple and noise1 (Vdc) max (A) max (W) max (mVp-p) 3.6 18 100 V 5 ETSA060300UD 6 ETSA120150UD 12 ETSA150120UD 15 efficiency level 3 18 100 V 1.5 18 120 V 1.2 18 150 V 1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors. O PART NUMBER KEY N Notes: TI MODEL N U • • • • • • • • ED FEATURES D IS C ETSA120150UD X - XX - SZ - CXX Base Number Factory Designation example of 12 Vdc, 1.5 A AC Input Plug: D = IEC 320 C8 plug DC Plug type: see output plug options on page 7 Input Cable: “Blank” = No Cable C = North American input cable 2 = European input cable 3 = United Kingdom input cable 4 = Australian input cable 5 = China input cable 6 = South Korea input cable 7 = Brazil input cable 8 = South Africa input cable 9 = Japan input cable cui.com Reserved for Custom Configurations For more information, please visit the product page. CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/17/2014 │ page 2 of 8 INPUT conditions/description min 90 frequency 47 current 115 Vac, cold start 230 Vac, cold start inrush current leakage current no load power consumption OUTPUT conditions/description line regulation 6 V model all other models min PROTECTIONS N load regulation conditions/description over voltage protection output voltage clamped by internal protection zener short circuit protection output shut down and auto restart parameter min TI parameter SAFETY & COMPLIANCE typ U parameter typ conditions/description min max units 264 Vac 63 Hz ED parameter voltage 0.5 A 40 80 A A 0.25 mA 0.3 W max units ±1 ±5 % ±5 % typ typ max units max units 3,000 4,242 Vac Vdc input to output at 10 mA for 1 minute isolation resistance input to output at 500 V dc safety approvals UL 60950-1, EN 60950-1/IEC 60950-1, PSE EMI/EMC FCC part 15 class B, CE, CISPR 22, ICES-003, ANSI C63.4, VCCI, EN 61204-3, EN 55022, EN 55024 EN 61000-3-(2, 3) Class A, EN 55024, IEC 61000-4-(2, 3, 4, 5, 6, 8, 11) O RoHS N isolation voltage 100 MΩ 2011/65/EU ENVIRONMENTAL conditions/description min max units 0 40 °C storage temperature -10 70 °C operating humidity 20 80 % storage humidity 10 90 % IS C parameter D operating temperature cui.com typ For more information, please visit the product page. CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/17/2014 │ page 3 of 8 MECHANICAL conditions/description 3.173 x 1.969 x 1.220 (80.6 x 50 x 31 mm) min input plug IEC320 / C8 weight 15 V model all other models typ units inch 105 110 MECHANICAL DRAWING N U units: mm tolerance: ±1mm TI 31±1 O N 50±1 max ED parameter dimensions D IS C 80.6±1 cui.com g g For more information, please visit the product page. CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/17/2014 │ page 4 of 8 DC CORD U ED cord length MODEL NO. CABLE GAUGE CORD LENGTH ETSA050360UD 18 AWG 1,000 ±100 18 AWG 1,000 ±100 20 AWG 1,530 ±100 ETSA150120UD 20 AWG 1,830 ±100 N ETSA060300UD ETSA120150UD NORTH AMERICAN INPUT CABLE IS C O N units: mm TI AC CORD EUROPEAN INPUT CABLE D units: mm cui.com For more information, please visit the product page. CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/17/2014 │ page 5 of 8 AC CORD (CONTINUED) UNITED KINGDOM INPUT CABLE U ED units: mm AUSTRALIAN INPUT CABLE IS C units: mm O CHINA INPUT CABLE N TI N units: mm SOUTH KOREA INPUT CABLE D units: mm cui.com For more information, please visit the product page. CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/17/2014 │ page 6 of 8 AC CORD (CONTINUED) BRAZIL INPUT CABLE U ED units: mm SOUTH AFRICA INPUT CABLE D IS C units: mm O JAPAN INPUT CABLE N TI N units: mm cui.com For more information, please visit the product page. CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/17/2014 │ page 7 of 8 OUTPUT PLUG OPTIONS 14±0.5 ED ø3.5 +0/-0.1 ø3.5 +0/-0.1 3.5 mm Phono Plug 14±0.5 *Tip positive P1 P1R C Right Angle PXR Standard PXX B A O IS C B N B A C C A B C Unit 5.5 2.1 9.5 mm P6/P6R 5.5 2.5 9.5 mm P7/P7R 3.5 1.35 9.5 mm P8/P8R 3.8 1.35 9.5 mm P9/P9R 3.8 1.05 9.5 mm TI Locking DC Plug EIAJ Plugs P5/P5R N Standard PX B A B A C A U Standard DC Plug A B C Unit P10 5.5 2.1 9.5 mm P11 5.5 2.5 9.5 mm EIAJ A B C P12/P12R EIAJ-1 2.35 0.7 P13/P13R EIAJ-2 4.0 1.7 P14/P14R EIAJ-3 4.75 1.7 C Right Angle PXXR D Stripped and Tinned 25±5 9±2 D DC PLUG TYPE PXX X X Plug Type: PXX = See above plug options ST = Stripped and Tinned Plug Angle: “blank” = Straight R = Right Angle *Contact CUI for additional plug options cui.com Plug Polarity: P = Center Positive N = Center Negative D Unit 9.5 NA mm 9.5 5.0 mm 9.5 5.0 mm For more information, please visit the product page. CUI Inc │ SERIES: ETSA 18W UD │ DESCRIPTION: AC-DC POWER SUPPLY date 11/17/2014 │ page 8 of 8 REVISION HISTORY rev. description date 01/25/2010 initial release new template applied 1.02 updated P7/P7R B dimension 1.03 V-Infinity branding removed, safety and EMI/EMC data updated 08/21/2012 1.04 updated series/model numbers 11/20/2012 1.05 added ac cord options ED 1.0 1.01 12/22/2011 03/23/2012 11/17/2014 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.