FEATURES
•
•
•
•
wire leads with feedback
12 Vdc rating
low profile
4.5 kHz rated frequency
SPECIFICATIONS
parameter
conditions/description
min
rated voltage
max
12
operating voltage
current consumption
typ
3
at rated voltage
rated frequency
4,000
sound pressure level
at 30 cm, rated voltage
dimensions
Ø24.0 x 5.0
4,500
units
Vdc
28
Vdc
13
mA
5,000
Hz
83
dB
mm
weight
material
ABS UL94 1/16” HB High Heat (black)
terminal
wire leads
7.4
g
operating temperature
-30
85
°C
storage temperature
-40
95
°C
RoHS
Notes:
2011/65/EU
1. All specifications measured at 5~35°C, humidity at 45~85%, under 86~106kPa pressure, unless otherwise noted.
cui.com
For more information, please visit the product page.
CUI Inc │ MODEL: CPE-121 │ DESCRIPTION: PIEZO BUZZER TRANSDUCER
date 01/08/2015 │ page 2 of 3
MECHANICAL DRAWING
units: mm
tolerance: ±0.5 mm
1.75
1.9
WIRE CONNECTIONS
Color
Function
Red
+terminal (M)
Black
-terminal (G)
Blue
feedback (F)
UL1571 LF 32AWG
5.0
34.0
1.0
blue
red
black
120.0
29.0
24.0
5.0
2.9
5.0
PERFORMANCE CURVES
P: Voltage vs. Sound Pressure Level
I: Voltage vs. Current Consumption
DRIVING CIRCUIT
Notes:
1. The current consumption and the sound pressure level are measured by using the recommended driving circuit shown above.
cui.com
1.9
For more information, please visit the product page.
CUI Inc │ MODEL: CPE-121 │ DESCRIPTION: PIEZO BUZZER TRANSDUCER
date 01/08/2015 │ page 3 of 3
REVISION HISTORY
rev.
description
date
1.0
initial release
11/12/2007
1.01
applied new spec template
01/08/2015
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.