VPM-S400 Datasheet - AC-DC POWER SUPPLY | CUI Inc

For more information, please visit the product page.
date
08/28/2012
page
1 of 5
SERIES: VPM-S400│ DESCRIPTION: AC-DC POWER SUPPLY
U
universal input, full range
remote sense & remote on/off
high power density: 7.15 watts/inch3
power factor corrected to EN 61000-3-2 class D
approved to UL/cUL, TUV, CB, CE & Class B Emissions
metal-enclosed
short circuit, overload, and overvoltage protections
RoHS
output
voltage1,2,3
min
(Vdc)
VPM-S400-12
12
12
VPM-S400-18
18
16
VPM-S400-24
24
22
VPM-S400-36
36
31
VPM-S400-48
48
42
1.
2.
3.
4.
5.
6.
output
power
efficiency
max
(A)
max
(% Vp-p)
max
(W)
typ
(%)
33.34
±1
400
80
21
25
±1
400
80
30
18.19
±1
400
80
41
12.9
±1
400
80
55
9.53
±1
400
80
max
(Vdc)
15
customer must specify output voltage
output is fully isolated
output voltage is measured at output power connector
output current limited by max. power
1% minimum load is required to maintain the ripple and regulation
ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 μF ceramic capacitor and 10 μF electrolytic capacitor in parallel.
IS
C
O
Notes:
ripple
and noise5,6
N
(Vdc)
output
current4
TI
preset
voltage
MODEL
N
•
•
•
•
•
•
•
ED
FEATURES
PART NUMBER KEY
VPM-S400 - XX
Base Number
D
Preset Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VPM-S400 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 2 of 5
INPUT
conditions/description
min
voltage
frequency
input current
max
units
90
264
Vac
47
63
Hz
at 90 Vac, full load
inrush current
at 230 Vac, full load, cold start
input fuse
built-in ac fuse. A blown fuse usually indicates permanent
damage to the power supply serviceable by factory only.
power factor correction
meets EN 61000-3-2 Class D
OUTPUT
conditions/description
min
typ
U
parameter
typ
ED
parameter
total regulation
overshoot
turn-on and turn-off overshoot shall not exceed 5% over
nominal voltage.
start-up time
at 120 Vac
hold-up time
at 80% load
N
output voltage returns to within 1% in less than 2.5 ms for a
50% load change. Peak transient does not exceed 5%.
35
mA
max
units
%
1
20
output user adjustable
remote sense
designated as V1S+ and V1S- on CN3. voltage compensates for
up to 0.5V line drop.
remote on/off
defined INH on CN3, requiring a TTL remote on-off, low signal to inhibit
output
LED display (LED 1)
green - the power supply is operating normally.
orange - when any protection occurs or RSW is low.
power good
designated as PG on CN3. This signal goes high 100~500 ms
after the output reaches regulation. It goes low at least 1 ms
before loss of regulation.
±5
%
O
N
TI
s
ms
adjustment range
parameter
A
±1
transient response
PROTECTIONS
5
min
typ
max
units
power supply shuts down when ac input is under 80 ±5 Vac.
When ac line reappears over 86 ±5 Vac, the power supply
restarts automatically.
IS
C
input under voltage protection
conditions/description
over voltage protection
shutdown and latches, ac input reset required to restart
over current protection
auto recovery
short circuit protection
continuous auto recovery upon removal of short
D
110
cui.com
130
%
140
%Io
For more information, please visit the product page.
CUI Inc │ SERIES: VPM-S400 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 3 of 5
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
primary to secondary at 10 mA for 3 seconds
primary to transformer core at 10 mA for 3 seconds
primary to earth ground for at 10 mA 3 seconds
safety approvals
UL 60950-1, CSA C22.2 No. 60950-1-03, TUV EN 60950-1, CE Mark (LVD) EN 61000-3-(2,3) & IEC
61000-4 Series Regulations, CB
EMI/EMC
EN 60601-1, EN 61204-3 Class B conducted/radiated, EN
61000-3-(2,3), IEC 61000-4-(2,3,4,5,6,8,11)
leakage current
at 240 Vac
grounding test
allowable resistance measured when 25 A current is applied
from the ground pin of the three prong plug to the farthest
earthed connection point.
RoHS compliant
yes
MTBF
according to MIL-HBK-217F at 30°C
parameter
conditions/description
operating temperature
derating linearly at 2.5% from 50~70°C
non-condensing
non-condensing
D
IS
C
O
N
operating humidity
storage humidity
cui.com
max
units
ED
Vac
Vac
Vac
3.5
mA
0.1
Ω
U
min
typ
hours
max
units
0
70
°C
-20
85
°C
5
90
%RH
5
95
%RH
TI
storage temperature
typ
100,000
N
ENVIRONMENTAL
min
3,000
1,500
1,500
For more information, please visit the product page.
CUI Inc │ SERIES: VPM-S400 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 4 of 5
MECHANICAL
parameter
conditions/description
dimensions
8 x 4 x 2 (203.2 x 101.6 x 50.8 mm)
min
typ
max
units
inch
1.05
kg
ED
weight
Two sets of 8 threaded mounting holes available on the enclosure.
B: 6-32, maximum insertion depth of 0.2 inches.
C: M4, maximum insertion depth of 0.2 inches.
Mounting holes
MECHANICAL DRAWING
IS
C
O
VOVO
VOVO
VO+
VO
L N
N
IEC 320
IE
VO+
VO
TI
N
U
units: inches (mm)
tolerance: inches: x.xx = ±0.02
mm: x.xx = ±0.5
LOGIC CONNECTOR (CN3)
INPUT CONNECTOR (CN1)
IEC320 or equivalent
snap-in mounting type
(option 1)
DINKLE DT-35-A02W-03
(option 2)
Suggested mating plug
IEC320
Suggested mating connector
Molex 19198-0016 or similar
OUTPUT CONNECTOR (CN2)
Howder HD-121-6P
(option 2)
Suggested mating connector
Molex 09-91-1400
Suggested mating connector
Molex 19198-0045 or similar
D
Molex Part No. 26-48-1141
or similar.
(option 1)
PIN
FUNCTION
PIN
FUNCTION
1~7
+Vo
1~3
+Vo
8~14
-Vo
4~6
-Vo
FAN
JS B5B-XH-A
JS B2B-XH-A
Suggested mating connector
JST XHP-5 or equivalent
Contact: SXH-002T-P0.6
Suggested mating connector
JST XHP-2 or equivalent
Contact: SXH-001T-P0.6
PIN
FUNCTION
1
PG - power good signal
2
INH - inhibit / remote On-Off
3
RTN - return
4
VIS- - output voltage remote sense-
5
VIS+ - output voltage remote sense+
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VPM-S400 │ DESCRIPTION: AC-DC POWER SUPPLY
date 08/28/2012 │ page 5 of 5
REVISION HISTORY
description
date
1.0
initial release
07/21/2006
1.01
new template applied, V-Infinity branding removed
ED
rev.
08/28/2012
D
IS
C
O
N
TI
N
U
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.