For more information, please visit the product page. date 08/21/2012 page 1 of 5 SERIES: 6 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY up to 6 W power universal input (90~264 Vac) single regulated output from 5~12 V over voltage, over current, and short circuit protections TUV safety approvals level V efficiency custom designs available U • • • • • • • ED FEATURES output voltage output current output power ripple and noise1 (Vdc) max (A) max (W) max (mVp-p) 1.2 6 50 V 0.5 6 120 V EPSA050120UE 5 EPSA120050UE 12 efficiency level 1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 μF aluminum electrolytic and 0.1 μF ceramic capacitors. O PART NUMBER KEY N Notes: TI MODEL N RoHS IS C EPSA050120UE - XX - EJ - CXX Base Number DC Plug Type Factory Designation D example of 5 Vdc, 1.2 A cui.com Reserved for Custom Configurations For more information, please visit the product page. CUI Inc │ SERIES: 6 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY date 08/21/2012 │ page 2 of 5 INPUT conditions/description min voltage 90 frequency 47 current OUTPUT parameter conditions/description min line regulation nom max units 264 Vac 63 Hz ED parameter nom 0.18 A max units ±5 load regulation % ±5 % 2 hold-up U start-up at 110 Vac, 50 Hz, 80% max. load 10 parameter conditions/description over voltage protection output shut down over current protection output shut down and auto restart SAFETY & COMPLIANCE parameter TI short circuit protection N PROTECTIONS conditions/description min isolation voltage input to output at 10 mA for 2 seconds isolation resistance input to output at 500 Vdc nom ms 200 % max units 3,000 Vac 10 MΩ EN 60950-1, CE EMI/EMC EN 55022 Class B, AS/NZS CISPR 22 Class B, EN 61000-3-(2,3), IEC 61000-4-(2,3,4,5,6,8,11) N safety approvals leakage current yes MTBF at full load, 25°C, Telcordia SR-332, Issue 2 O RoHS compliant s 0.25 mA 300,000 hours max units ENVIRONMENTAL parameter min nom 0 40 °C storage temperature -25 85 °C operating humidity 10 95 % storage humidity 10 95 % D IS C operating temperature conditions/description cui.com For more information, please visit the product page. CUI Inc │ SERIES: 6 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY date 08/21/2012 │ page 3 of 5 MECHANICAL conditions/description dimensions 2.953 x 1.378 x 1.457 (75 x 35 x 55 mm) min input plug fixed Europe max units inch MECHANICAL DRAWING units: mm[inch] 37.0 1.457 1.0 N U 35.00 1.378 1.0 typ ED parameter IS C O N TI 75.0 2.953 1.0 D DC CORD cord length cui.com MODEL NO. CABLE GAUGE CORD LENGTH EPSA050120UE 22 AWG 1,530 mm +50/-30 EPSA120050UE 24 AWG 1,530 mm +50/-30 For more information, please visit the product page. CUI Inc │ SERIES: 6 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY date 08/21/2012 │ page 4 of 5 OUTPUT PLUG OPTIONS 14±0.5 ED ø3.5 +0/-0.1 ø3.5 +0/-0.1 3.5 mm Phono Plug 14±0.5 *Tip positive P1 P1R C A B C Unit 2.1 9.5 mm N O B N B A C C B Right Angle PXR Locking DC Plug EIAJ Plugs A 5.5 P6/P6R 5.5 2.5 9.5 mm P7/P7R 3.5 1.35 9.5 mm P8/P8R 3.8 1.35 9.5 mm P9/P9R 3.8 1.05 9.5 mm A B C Unit P10 5.5 2.1 9.5 mm P11 5.5 2.5 9.5 mm TI Standard PX P5/P5R B A B A C A U Standard DC Plug EIAJ A B C D Unit P12/P12R EIAJ-1 2.35 0.7 9.5 NA mm P13/P13R EIAJ-2 4.0 1.7 9.5 5.0 mm P14/P14R EIAJ-3 4.75 1.7 9.5 5.0 mm IS C C Standard PXX Right Angle PXXR D Stripped and Tinned 25±5 9±2 D DC PLUG TYPE ST Stripped and Tinned PXX X X Plug Type Plug Angle: “Blank” = Standard R = Right Angle Plug Polarity: “Blank” = N/A P = Center Positive N = Center Negative *Contact CUI for additional output plug options. cui.com For more information, please visit the product page. CUI Inc │ SERIES: 6 W WALL PLUG - EURO BLADE │ DESCRIPTION: AC-DC POWER SUPPLY date 08/21/2012 │ page 5 of 5 REVISION HISTORY description date 1.0 initial release 02/01/2010 ED rev. 1.01 updated output plug options 1.02 updated inrush current, protection data, and output plug options 11/11/2010 12/09/2010 1.03 updated template 01/24/2012 1.04 updated P7/P7R B dimension 1.05 V-Infinity branding removed, safety and EMI/EMC data updated 03/14/2012 08/21/2012 D IS C O N TI N U The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.