EtronTech EM68C16CWQE 64M x 16 bit DDRII Synchronous DRAM (SDRAM) Etron Confidential Advanced (Rev. 1.0, Jan. /2014) Features Overview • JEDEC Standard Compliant • JEDEC standard 1.8V I/O (SSTL_18-compatible) • Power supplies: VDD & VDDQ = +1.8V ± 0.1V • Supports JEDEC clock jitter specification • Fully synchronous operation • Fast clock rate: 333/400/533 MHz • Differential Clock, CK & CK# • Bidirectional single/differential data strobe -DQS & DQS# • 8 internal banks for concurrent operation • 4-bit prefetch architecture • Internal pipeline architecture • Precharge & active power down • Programmable Mode & Extended Mode registers • Posted CAS# additive latency (AL): 0, 1, 2, 3, 4, 5, 6 • WRITE latency = READ latency - 1 tCK • Burst lengths: 4 or 8 • Burst type: Sequential / Interleave • DLL enable/disable • On-die termination (ODT) • RoHS compliant • Auto Refresh and Self Refresh • 8192 refresh cycles / 64ms - Average refresh period 7.8µs @ -40℃ ≦TC≦ +85℃ 3.9µs @ +85℃ <TC≦ +95℃ • 84-ball 8 x 12.5 x 1.2mm (max) FBGA package - Pb and Halogen Free The EM68C16C is a high-speed CMOS DoubleData-Rate-Two (DDR2), synchronous dynamic random - access memory (SDRAM) containing 1024 Mbits in a 16-bit wide data I/Os. It is internally configured as a 8bank DRAM, 8 banks x 8Mb addresses x 16 I/Os. The device is designed to comply with DDR2 DRAM key features such as posted CAS# with additive latency, Write latency = Read latency -1 and On Die Termination(ODT). All of the control and address inputs are synchronized with a pair of externally supplied differential clocks. Inputs are latched at the cross point of differential clocks (CK rising and CK# falling) All I/Os are synchronized with a pair of bidirectional strobes (DQS and DQS#) in a source synchronous fashion. The address bus is used to convey row, column, and bank address information in RAS #, CAS# multiplexing style. Accesses begin with the registration of a Bank Activate command, and then it is followed by a Read or Write command. Read and write accesses to the DDR2 SDRAM are 4 or 8-bit burst oriented; accesses start at a selected location and continue for a programmed number of locations in a programmed sequence. Operating the eight memory banks in an interleaved fashion allows random access operation to occur at a higher rate than is possible with standard DRAMs. An auto precharge function may be enabled to provide a self-timed row precharge that is initiated at the end of the burst sequence. A sequential and gapless data rate is possible depending on burst length, CAS latency, and speed grade of the device. Table 1. Ordering Information Part Number Clock Frequency Data Rate EM68C16CWQE-18IH 533MHz 1066Mbps/pin EM68C16CWQE-25IH 400MHz 800Mbps/pin EM68C16CWQE-3IH 333MHz 667Mbps/pin WQ: indicates FBGA package E: indicates Generation Code I: indicates Industrial Grade H: indicates Pb and Halogen Free for FBGA Package Power Supply VDD 1.8V, VDDQ 1.8V VDD 1.8V, VDDQ 1.8V VDD 1.8V, VDDQ 1.8V Package FBGA FBGA FBGA Etron Technology, Inc. No. 6, Technology Rd. V, Hsinchu Science Park, Hsinchu, Taiwan 30078, R.O.C. TEL: (886)-3-5782345 FAX: (886)-3-5778671 Etron Technology, Inc. reserves the right to change products or specification without notice. EtronTech EM68C16CWQE Table 2. Speed Grade Information Speed Grade Clock Frequency CAS Latency tRCD (ns) tRP (ns) DDR2-1066 533MHz 7 13.125 13.125 DDR2-800 400MHz 5 12.5 12.5 DDR2-667 333MHz 5 15 15 Figure 1. Ball Assignment (FBGA Top View) 1 2 3 7 8 9 A VDD NC VSS VSSQ UDQS# VDDQ B DQ14 VSSQ UDM UDQS. VSSQ DQ15 C VDDQ DQ9 VDDQ VDDQ DQ8 VDDQ D DQ12 VSSQ DQ11 DQ10 VSSQ DQ13 E VDD NC VSS VSSQ LDQS# VDDQ F DQ6 VSSQ LDM LDQS VSSQ DQ7 G VDDQ DQ1 VDDQ VDDQ DQ0 VDDQ H DQ4 VSSQ DQ3 DQ2 VSSQ DQ5 J VDDL VREF VSS VSSDL CK VDD CKE WE# RAS# CK# ODT BA0 BA1 CAS# CS# A10 A1 A2 A0 A3 A5 A6 A4 A7 A9 A11 A8 A12 NC NC NC K L BA2 M N VSS P R VDD Etron Confidential 2 VDD VSS Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 2. Block Diagram DLL CLOCK BUFFER Row Decoder CK CK# Column Decoder 8M x 16 CELL ARRAY (BANK #1) Column Decoder Row Decoder COMMAND DECODER CONTROL SIGNAL GENERATOR Row Decoder CKE CS# RAS# CAS# WE# 8M x 16 CELL ARRAY (BANK #0) 8M x 16 CELL ARRAY (BANK #2) A10/AP COLUMN COUNTER MODE REGISTER Row Decoder Column Decoder 8M x 16 CELL ARRAY (BANK #3) Column Decoder Row Decoder ~ A9 A11 A12 BA0 BA1 BA2 ADDRESS BUFFER 8M x 16 CELL ARRAY (BANK #4) Column Decoder Row Decoder A0 REFRESH COUNTER 8M x 16 CELL ARRAY (BANK #5) LDQS LDQS# UDQS UDQS# DATA STROBE BUFFER Row Decoder Column Decoder DQ Buffer 8M x 16 CELL ARRAY (BANK #6) Column Decoder DQ0 Row Decoder ~ DQ15 8M x 16 CELL ARRAY (BANK #7) Column Decoder ODT LDM UDM Etron Confidential 3 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 3. State Diagram CKEL OCD calibration Initialization Sequence SRF H CKE PR Setting MR, EMR(1) EMR(2) EMR(3) (E)MRS Idle All banks precharged ACT Self Refreshing REF CK EL CK EH Refreshing EL CK Precharge Power Down Automatic Sequence Cammand Sequence Activating Active Power Down CKEH CKE L WR Bank Active RD RD Reading W WR CKEL L CKE RA CKEL Writing WR RD A RD CKEL = CKE LOW, enter Power Down RDA A WR WRA Writing With Autoprecharge PR, PRA PR, PRA CKEH = CKE HIGH, exit Power Down,exit Self Refresh ACT = Activate RDA Reading With Autoprecharge PR, PRA WR(A) = Write (with Autoprecharge) RD(A) = Read (with Autoprecharge) PR(A) = Precharge (All) (E)MRS = (Extended) Mode Register Set SRF = Enter Self Refresh Precharging REF = Refresh Note: Use caution with this diagram. It is indented to provide a floorplan of the possible state transitions and the commands to control them, not all details. In particular situations involving more than one bank, enabling/disabling on-die termination, Power Down entry/exit, timing restrictions during state transitions, among other things, are not captured in full detail. Etron Confidential 4 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Ball Descriptions Table 3. Ball Descriptions Symbol Type Description CK, CK# Input Differential Clock: CK, CK# are driven by the system clock. All SDRAM input signals are sampled on the crossing of positive edge of CK and negative edge of CK#. Output (Read) data is referenced to the crossings of CK and CK# (both directions of crossing). CKE Input Clock Enable: CKE activates (HIGH) and deactivates (LOW) the CK signal. If CKE goes LOW synchronously with clock, the internal clock is suspended from the next clock cycle and the state of output and burst address is frozen as long as the CKE remains LOW. When all banks are in the idle state, deactivating the clock controls the entry to the Power Down and Self Refresh modes. BA0-BA2 Input Bank Address: BA0-BA2 define to which bank the BankActivate, Read, Write, or BankPrecharge command is being applied. A0-A12 Input Address Inputs: A0-A12 are sampled during the BankActivate command (row address A0A12) and Read/Write command (column address A0-A9 with A10 defining Auto Precharge). CS# Input Chip Select: CS# enables (sampled LOW) and disables (sampled HIGH) the command decoder. All commands are masked when CS# is sampled HIGH. CS# provides for external bank selection on systems with multiple banks. It is considered part of the command code. RAS# Input Row Address Strobe: The RAS# signal defines the operation commands in conjunction with the CAS# and WE# signals and is latched at the crossing of positive edges of CK and negative edge of CK#. When RAS# and CS# are asserted "LOW" and CAS# is asserted "HIGH," either the BankActivate command or the Precharge command is selected by the WE# signal. When the WE# is asserted "HIGH," the BankActivate command is selected and the bank designated by BA is turned on to the active state. When the WE# is asserted "LOW," the Precharge command is selected and the bank designated by BA is switched to the idle state after the precharge operation. CAS# Input Column Address Strobe: The CAS# signal defines the operation commands in conjunction with the RAS# and WE# signals and is latched at the crossing of positive edges of CK and negative edge of CK#. When RAS# is held "HIGH" and CS# is asserted "LOW," the column access is started by asserting CAS# "LOW." Then, the Read or Write command is selected by asserting WE# “HIGH " or “LOW". WE# Input Write Enable: The WE# signal defines the operation commands in conjunction with the RAS# and CAS# signals and is latched at the crossing of positive edges of CK and negative edge of CK#. The WE# input is used to select the BankActivate or Precharge command and Read or Write command. LDQS, Input / LDQS# Output Bidirectional Data Strobe: Specifies timing for Input and Output data. Read Data Strobe is edge triggered. Write Data Strobe provides a setup and hold time for data and DQM. LDQS is for DQ0~7, UDQS is for DQ8~15. The data strobes LDOS and UDQS may be used in single ended mode or paired with LDQS# and UDQS# to provide differential pair signaling to the system during both reads and writes.A control bit at EMR (1)[A10] enables or disables all complementary data strobe signals. UDQS UDQS# LDM, Input Data Input Mask: Input data is masked when DM is sampled HIGH during a write cycle. LDM masks DQ0-DQ7, UDM masks DQ8-DQ15. DQ0 - DQ15 Input / Output Data I/O: The Data bus input and output data are synchronized with positive and negative edges of DQS/DQS#. The I/Os are byte-maskable during Writes. ODT Input On Die Termination: ODT enables internal termination resistance. It is applied to each DQ, LDQS/LDQS#, UDQS/UDQS#, LDM, and UDM signal. The ODT pin is ignored if the EMR (1) is programmed to disable ODT. UDM Etron Confidential 5 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE VDD Supply Power Supply: +1.8V ±0.1V VSS Supply Ground VDDL Supply DLL Power Supply: +1.8V ±0.1V VSSDL Supply DLL Ground VDDQ Supply DQ Power: +1.8V ±0.1V. VSSQ Supply DQ Ground VREF Supply Reference Voltage for Inputs: +0.5*VDDQ NC - Etron Confidential No Connect: These pins should be left unconnected. 6 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Operation Mode Table 4 shows the truth table for the operation commands. Table 4. Truth Table (Note (1), (2)) Command BankActivate State CKEn-1 CKEn DM BA0-2 A10 A0-9, 11-12 CS# RAS# CAS# WE# Idle(3) H H X V Row address L L H H Single Bank Precharge Any H H X V L X L L H L All Banks Precharge Any H H X X H X L L H L Column address L H L L L H L L L H L H L H L H L L L L Write Active(3) H H X V L Write with AutoPrecharge Active(3) H H X V H Read Active(3) H H X V L Read and Autoprecharge Active(3) H H X V H (Extended) Mode Register Set Idle H H X V No-Operation Any H X X X X X L H H H Active(4) H X X X X X L H H L Device Deselect Any H X X X X X H X X X Refresh Idle H H X X X X L L L H SelfRefresh Entry Idle H L X X X X L L L H SelfRefresh Exit Idle L H X X X X H X X X L H H H Power Down Mode Entry Idle H L X X X X H X X X L H H H Power Down Mode Exit Any L H X X X X H X X X L H H H Data Input Mask Disable Active H X L X X X X X X X Data Input Mask Enable(5) Active H X H X X X X NOTE 1: V=Valid data, X=Don't Care, L=Low level, H=High level NOTE 2: CKEn signal is input level when commands are provided. NOTE 3: CKEn-1 signal is input level one clock cycle before the commands are provided. NOTE 4: These are states of bank designated by BA signal. NOTE 5: Device state is 4, and 8 burst operation. NOTE 6: LDM and UDM can be enabled respectively. X X X Burst Stop Etron Confidential 7 (A0 – A9) Column address (A0 – A9) OP code Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Functional Description Read and write accesses to the DDR2 SDRAM are burst oriented; accesses start at a selected location and continue for a burst length of four or eight in a programmed sequence. Accesses begin with the registration of an Active command, which is then followed by a Read or Write command. The address bits registered coincident with the active command are used to select the bank and row to be accessed (BA0-BA2 select the bank; A0-A12 select the row). The address bits registered coincident with the Read or Write command are used to select the starting column location for the burst access and to determine if the auto precharge command is to be issued. Prior to normal operation, the DDR2 SDRAM must be initialized. The following sections provide detailed information covering device initialization, register definition, command descriptions, and device operation. z Power-up and Initialization DDR2 SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those specified may result in undefined operation. The following sequence is required for POWER UP and Initialization. 1. Apply power and attempt to maintain CKE below 0.2*VDDQ and ODT *1 at a low state (all other inputs may be undefined.) The VDD voltage ramp time must be no greater than 200ms from when VDD ramps from 300mV to VDDmin; and during the VDD voltage ramp, |VDD-VDDQ| ≦ 0.3V - VDD, VDDL and VDDQ are driven from a single power converter output, AND - VTT is limited to 0.95 V max, AND - VREF tracks VDDQ/2. or - Apply VDD before or at the same time as VDDL. - Apply VDDL before or at the same time as VDDQ. - Apply VDDQ before or at the same time as VTT & VREF. At least one of these two sets of conditions must be met. 2. Start clock and maintain stable condition. 3. For the minimum of 200µs after stable power and clock (CK, CK#), then apply NOP or deselect and take CKE HIGH. 4. Wait minimum of 400ns then issue precharge all command. NOP or deselect applied during 400ns period. 5. Issue EMRS(2) command. (To issue EMRS (2) command, provide “LOW” to BA0 and BA2, “HIGH” to BA1.) 6. Issue EMRS (3) command. (To issue EMRS (3) command, provide “LOW” to BA2, “HIGH” to BA0 and BA1.) 7. Issue EMRS to enable DLL. (To issue "DLL Enable" command, provide "LOW" to A0, "HIGH" to BA0 and "LOW" to BA1 and BA2.) 8. Issue a Mode Register Set command for “DLL reset”. (To issue DLL reset command, provide "HIGH" to A8 and "LOW" to BA0-BA2) 9. Issue precharge all command. 10. Issue 2 or more auto-refresh commands. 11. Issue a mode register set command with LOW to A8 to initialize device operation. (i.e. to program operating parameters without resetting the DLL.) 12. At least 200 clocks after step 8, execute OCD Calibration (Off Chip Driver impedance adjustment).If OCD calibration is not used, EMRS OCD Default command (A9=A8=A7=HIGH) followed by EMRS OCD calibration Mode Exit command (A9=A8=A7=LOW) must be issued with other operating parameters of EMRS. 13. The DDR2 SDRAM is now ready for normal operation. NOTE 1: To guarantee ODT off, VREF must be valid and a LOW level must be applied to the ODT pin. Etron Confidential 8 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE z Mode Register Set(MRS) The mode register stores the data for controlling the various operating modes of DDR2 SDRAM. It controls CAS latency, burst length, burst sequence, test mode, DLL reset, WR, and various vendor specific options to make DDR2 SDRAM useful for various applications.The default value of the mode register is not defined, therefore the mode register must be programmed during initialization for proper operation. The mode register is written by asserting LOW on CS#, RAS#, CAS#, WE#, BA0 and BA1, while controlling the state of address pins A0 - A12. The DDR2 SDRAM should be in all bank precharge state with CKE already HIGH prior to writing into the mode register.The mode register set command cycle time (tMRD) is required to complete the write operation to the mode register. The mode register contents can be changed using the same command and clock cycle requirements during normal operation as long as all bank are in the precharge state.The mode register is divided into various fields depending on functionality. - Burst Length Field (A2, A1, A0) This field specifies the data length of column access and selects the Burst Length. - Addressing Mode Select Field (A3) The Addressing Mode can be Interleave Mode or Sequential Mode. Both Sequential Mode and Interleave Mode support burst length of 4 and 8. -CAS Latency Field (A6, A5, A4) This field specifies the number of clock cycles from the assertion of the Read command to the first read data. The minimum whole value of CAS Latency depends on the frequency of CK. The minimum whole value satisfying the following formula must be programmed into this field. tCAC(min) ≦ CAS Latency X tCK - Test Mode field: A7; DLL Reset Mode field: A8 These two bits must be programmed to "00" in normal operation. - (BA0-BA1): Bank addresses to define MRS selection. Table 5. Mode Register Bitmap BA2 BA1 BA0 A12 A11 A10 0*2 0 A8 0 1 0 PD DLL Reset No Yes A9 WR A8 A7 A6 DLL TM A7 0 1 A12 Active power down exit time 0 Fast exit (use tXARD) 1 Slow exit (use tXARDS) A5 A4 A3 CAS Latency Mode Normal Test A2 BT A3 0 1 A1 A0 Burst Length Burst Type Sequential Interleave A2 0 0 Address Field Mode Register A1 1 1 A0 0 1 BL 4 8 *1 Write recovery for autoprecharge A11 A10 A9 WR(cycles) 0 0 0 Reserved 0 0 1 2 A6 0 0 A5 0 0 A4 0 1 CAS Latency Reserved Reserved BA1 BA0 MRS Mode 0 1 0 3 0 1 0 Reserved 0 0 1 1 0 1 0 1 MR EMR(1) EMR(2) EMR(3) 0 1 1 1 1 1 0 0 1 1 1 0 1 0 1 4 5 6 7 8 0 1 1 1 1 1 0 0 1 1 1 0 1 0 1 3 4 5 6 7 Note 1:.For DDR2-667/800/1066, WR min is determined by tCK (avg) max and WR max is determined by tCK(avg) min. WR [cycles] = RU {tWR[ns]/tCK(avg)[ns]}, where RU stands for round up. The mode register must be programmed to this value.This is also used with tRP to determine tDAL. NOTE 2: BA2 is reserved for future use and must be set to 0 when programming the MR. Etron Confidential 9 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE z Extended Mode Register Set (EMRS ) - EMR(1) The extended mode register(1) stores the data for enabling or disabling the DLL, output driver strength, ODT value selection and additive latency. The default value of the extended mode register is not defined, therefore the extended mode register must be written after power-up for proper operation. The extended mode register is written by asserting LOW on CS#, RAS#, CAS#, WE#, BA1 and HIGH on BA0, while controlling the states of address pins A0 ~ A12. The DDR2 SDRAM should be in all bank precharge with CKE already HIGH prior to writing into the extended mode register. The mode register set command cycle time (tMRD) must be satisfied to complete the write operation to the extended mode register. Mode register contents can be changed using the same command and clock cycle requirements during normal operation as long as all banks are in the precharge state. A0 is used for DLL enable or disable. A1 is used for enabling a half strength data-output driver. A3~A5 determine the additive latency, A2 and A6 are used for ODT value selection, A7~A9 are used for OCD control, A10 is used for DQS# disable. - DLL Enable/Disable The DLL must be enabled for normal operation. DLL enable is required during power up initialization, and upon returning to normal operation after having the DLL disabled. The DLL is automatically disabled when entering self refresh operation and is automatically re-enabled upon exit of self refresh operation. Any time the DLL is enabled (and subsequently reset), 200 clock cycles must occur before a Read command can be issued to allow time for the internal clock to be synchronized with the external clock. Failing to wait for synchronization to occur may result in a violation of the tAC or tDQSCK parameters. Table 6. Extended Mode Register EMR (1) Bitmap BA2 BA1 BA0 A12 A11 A10 0*3 0 A9 A8 A7 Qoff 0*3 DQS# OCD program 1 BA1 BA0 MRS mode 0 0 MR 0 1 EMR(1) 1 0 EMR(2) A10 0 1 A6 1 1 EMR(3) A9 0 0 0 1 1 A8 0 0 1 0 1 A7 0 1 0 0 1 DQS# Enable Disable A5 A4 A2 A6 0 0 1 A2 0 1 0 Rtt(NOMINAL) ODT Disable 75Ω 1 1 50Ω A0 Address Field Reserved Reserved Reserved OCD Calibration default*1 Qoff Output buffer enabled Output buffer disabled A0 0 1 150Ω OCD Calibration Program *2 A1 Rtt Additive Latency Rtt D.I.C DLL Extended Mode Register OCD Calibration mode exit; maintain setting A12 0 1 A3 A1 0 1 DLL Enable Enable Disable Output Driver Impedance Control Full strength Reduced strength A5 A4 A3 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 Additive Latency 0 1 2 3 4 5 6 Reserved NOTE 1: After setting to default, OCD calibration mode needs to be exited by setting A9-A7 to 000. NOTE 2: Output disabled – DQs, DQSs, DQSs#.This feature is intended to be used during IDD characterization of read current. NOTE 3: A11 and BA2 are reserved for future use and must be set to 0 when programming the MR. Etron Confidential 10 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE - EMR(2) The extended mode register (2) controls refresh related features. The default value of the extended mode register (2) is not defined, therefore the extended mode register (2) must be written after power-up for proper operation. The extended mode register(2) is written by asserting LOW on CS#, RAS#, CAS#, WE#, HIGH on BA1 and LOW on BA0, while controlling the states of address pins A0 ~ A12. The DDR2 SDRAM should be in all bank precharge with CKE already HIGH prior to writing into the extended mode register (2). The mode register set command cycle time (tMRD) must be satisfied to complete the write operation to the extended mode register (2). Mode register contents can be changed using the same command and clock cycle requirements during normal operation as long as all banks are in the precharge state. Table 7. Extended Mode Register EMR(2) Bitmap BA2 BA1 BA0 A12 A11 A10 0*3 1 0*1 0 A7 0 1 A9 A8 A7 SRF A6 A5 A4 A3 A2 A1 *1 A0 Address Field Extended Mode Register(2) 0 High Temperature Self-Refresh Rate Enable Disable *2 Enable NOTE 1: The rest bits in EMRS(2) are reserved for future use and all bits in EMRS(2) except A7, BA0 and BA1 must be programmed to 0 when setting the extended mode register(2) during initialization. NOTE 2: Due to the migration nature, user needs to ensure the DRAM part supports higher than 85℃ Tcase temperature self-refresh entry. If the high temperature self-refresh mode is supported then controller can set the EMRS2[A7] bit to enable the self-refresh rate in case of higher than 85℃ temperature self-refresh operation. NOTE 3: BA2 is reserved for future use and must be set to 0 when programming the MR. Etron Confidential 11 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE - EMR(3) No function is defined in extended mode register(3).The default value of the extended mode register(3) is not defined, therefore the extended mode register(3) must be programmed during initialization for proper operation. Table 8. Extended Mode Register EMR (3) Bitmap BA2 BA1 BA0 A12 A11 A10 0*1 1 A9 A8 A7 A6 A5 A4 A3 A2 A1 0*1 1 A0 Address Field Extended Mode Register(3) NOTE 1: All bits in EMR (3) except BA0 and BA1 are reserved for future use and must be set to 0 when programming the EMR (3). Etron Confidential 12 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE z ODT (On Die Termination) On Die Termination (ODT) is a feature that allows a DRAM to turn on/off termination resistance for each DQ, UDQS/UDQS#, LDQS/LDQS#, UDM, and LDM signal via the ODT control pin. The ODT feature is designed to improve signal integrity of the memory channel by allowing the DRAM controller to independently turn on/off termination resistance for any or all DRAM devices. The ODT function is supported for ACTIVE and STANDBY modes. It is turned off and not supported in SELF REFRESH mode. Figure 4. Functional representation of ODT VDDQ VDDQ VDDQ SW1 SW2 SW3 Rval1 Rval2 Rval3 DRAM Input Buffer Input pin Rval1 SW1 VSSQ Rval2 SW2 VSSQ Rval3 SW3 VSSQ Switch (sw1, sw2, sw3) is enabled by ODT pin. Selection among sw1, sw2, and sw3 is determined by “Rtt (nominal)” in EMR. Termination included on all DQs, DM, DQS, and DQS# pins Table 9. ODT DC Electrical Characteristics Parameter/Condition Symbol Min. Nom. Max. Unit Note Rtt effective impedance value for EMRS(A6,A2)=0,1;75Ω Rtt1(eff) Ω 60 75 90 Rtt effective impedance value for EMRS(A6,A2)=1,0;150Ω Rtt2(eff) Ω 120 150 180 Rtt effective impedance value for EMRS(A6,A2)=1,1;50Ω Rtt3(eff) Ω 40 50 60 % Rtt mismatch tolerance between any pull-up/pull-down pair Rtt(mis) -6 6 NOTE 1: Measurement Definition for Rtt(eff): Apply VIH (ac) and VIL (ac) to test pin seperately, then measure current I(VIH(ac)) and I(VIL(ac)) respectively. Rtt(eff)= 1 1 1 2 VIH (ac ) − VIL (ac ) I(VIH (ac))-I(VIL (ac)) NOTE 2: Measurement Defintion for Rtt (mis): Measure voltage (VM) at test pin (midpoint) with no load. ⎛ 2xVM ⎞ Rtt(mis)= ⎜ − 1⎟ ×100% ⎝ VDDQ ⎠ Etron Confidential 13 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE z Bank activate command The Bank Activate command is issued by holding CAS# and WE# HIGH with CS# and RAS# LOW at the rising edge of the clock. The bank addresses BA0-BA2 are used to select the desired bank. The row addresses A0 through A12 are used to determine which row to activate in the selected bank. The Bank Activate command must be applied before any Read or Write operation can be executed. Immediately after the bank active command, the DDR2 SDRAM can accept a read or write command (with or without Auto-Precharge) on the following clock cycle. If a R/W command is issued to a bank that has not satisfied the tRCDmin specification, then additive latency must be programmed into the device to delay the R/W command which is internally issued to the device. The additive latency value must be chosen to assure tRCDmin is satisfied. Additive latencies of 0, 1, 2, 3, and 4 are supported. Once a bank has been activated it must be precharged before another Bank Activate command can be applied to the same bank. The bank active and precharge times are defined as tRAS and tRP, respectively. The minimum time interval between successive Bank Activate commands to the same bank is determined (tRC). The minimum time interval between Bank Active commands is tRRD In order to ensure that 8 bank devices do not exceed the instantaneous current supplying capability of 4 bank devices, certain restrictions on operation of the 8 bank devices must be observed. There are two rules. One for restricting the number of sequential ACT commands that can be issued and another for allowing more time for RAS precharge for a Precharge All command. The rules are as follows: - 8 bank device Sequential Bank Activation Restriction : No more than 4 banks may be activated in a rolling tFAW window. Converting to clocks is done by dividing tFAW[ns] by tCK[ns] or tCK[ns], depending on the speed bin, and rounding up to next integer value. As an example of the rolling window, if RU{ (tFAW / tCK) } or RU{ (tFAW / tCK)} is 10 clocks, and an activate command is issued in clock N, no more than three further activate commands may be issued at or between clock N+1 and N+9. - 8 bank device Precharge All Allowance : tRP for a Precharge All command for an 8 Bank device will equal to tRP + 1 x tCK or tRP + 1 x tCK, depending on the speed bin, where tRP = RU{ tRP / tCK} and tRP is the value for a single bank precharge. z Read and Write access modes After a bank has been activated, a Read or Write cycle can be executed. This is accomplished by setting RAS# HIGH, CS# and CAS# LOW at the clock’s rising edge. WE# must also be defined at this time to determine whether the access cycle is a Read operation (WE# HIGH) or a Write operation (WE# LOW). The DDR2 SDRAM provides a fast column access operation. A single Read or Write Command will initiate a serial Read or Write operation on successive clock cycles. The boundary of the burst cycle is strictly restricted to specific segments of the page length. Any system or application incorporating random access memory products should be properly designed, tested, and qualified to ensure proper use or access of such memory products. Disproportionate, excessive, and/or repeated access to a particular address or addresses may result in reduction of product life. z Posted CAS# Posted CAS# operation is supported to make command and data bus efficient for sustainable bandwidths in DDR2 SDRAM. In this operation, the DDR2 SDRAM allows a CAS# Read or Write command to be issued immediately after the RAS bank activate command (or any time during the RAS# -CAS#-delay time, tRCD, period). The command is held for the time of the Additive Latency (AL) before it is issued inside the device. The Read Latency (RL) is controlled by the sum of AL and the CAS latency (CL). Therefore if a user chooses to issue a R/W command before the tRCDmin, then AL (greater than 0) must be written into the EMR(1). The Write Latency (WL) is always defined as RL - 1 (Read Latency -1) where Read Latency is defined as the sum of additive latency plus CAS latency (RL=AL+CL). Read or Write operations using AL allow seamless bursts (refer to seamless operation timing diagram examples in Read burst and Write burst section) z Burst Mode Operation Burst mode operation is used to provide a constant flow of data to memory locations (Write cycle), or from memory locations (Read cycle). The parameters that define how the burst mode will operate are burst sequence and burst length. The DDR2 SDRAM supports 4 bit and 8 bit burst modes only. For 8 bit burst mode, full interleave address ordering is supported, however, sequential address ordering is nibble based for ease of implementation. The burst length is programmable and defined by the addresses A0 ~ A2 of the MRS. The burst type, either sequential or interleaved, is programmable and defined by the address bit 3 (A3) of the MRS. Seamless burst Read or Write operations are supported. Interruption of a burst Read or Write operation is prohibited, when burst length = 4 is programmed. For burst interruption of a Read or Write burst when burst length = 8 is used, see the “Burst Interruption“ section of this datasheet. A Burst Stop command is not supported on DDR2 SDRAM devices. Etron Confidential 14 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Table 10. Burst Definition, Addressing Sequence of Sequential and Interleave Mode Burst Length 4 8 Start Address A2 A1 A0 X 0 0 X 0 1 X 1 0 X 1 1 0 0 0 0 0 1 0 1 0 0 1 1 1 0 0 1 0 1 1 1 0 1 1 1 Sequential Interleave 0, 1, 2, 3 1, 2, 3, 0 2, 3, 0, 1 3, 0, 1, 2 0, 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 0, 5, 6, 7, 4 2, 3, 0, 1, 6, 7, 4, 5 3, 0, 1, 2, 7, 4, 5, 6 4, 5, 6, 7, 0, 1, 2, 3 5, 6, 7, 4, 1, 2, 3, 0 6, 7, 4, 5, 2, 3, 0, 1 7, 4, 5, 6, 3, 0, 1, 2 0, 1, 2, 3 1, 0, 3, 2 2, 3, 0, 1 3, 2, 1, 0 0, 1, 2, 3, 4, 5, 6, 7 1, 0, 3, 2, 5, 4, 7, 6 2, 3, 0, 1, 6, 7, 4, 5 3, 2, 1, 0, 7, 6, 5, 4 4, 5, 6, 7, 0, 1, 2, 3 5, 4, 7, 6, 1, 0, 3, 2 6, 7, 4, 5, 2, 3, 0, 1 7, 6, 5, 4, 3, 2, 1, 0 z Burst read command The Burst Read command is initiated by having CS# and CAS# LOW while holding RAS# and WE# HIGH at the rising edge of the clock. The address inputs determine the starting column address for the burst. The delay from the start of the command to when the data from the first cell appears on the outputs is equal to the value of the Read Latency (RL). The data strobe output (DQS) is driven LOW 1 clock cycle before valid data (DQ) is driven onto the data bus. The first bit of the burst is synchronized with the rising edge of the data strobe (DQS). Each subsequent data-out appears on the DQ pin in phase with the DQS signal in a source synchronous manner. The RL is equal to an additive latency (AL) plus CAS Latency (CL). The CL is defined by the Mode Register Set (MRS), similar to the existing SDR and DDR SDRAMs. The AL is defined by the Extended Mode Register Set (1) (EMRS (1)). DDR2 SDRAM pin timings are specified for either single ended mode or differential mode depending on the setting of the EMRS “Enable DQS” mode bit; timing advantages of differential mode are realized in system design. The method by which the DDR2 SDRAM pin timings are measured is mode dependent. In single ended mode, timing relationships are measured relative to the rising or falling edges of DQS crossing at VREF. In differential mode, these timing relationships are measured relative to the crosspoint of DQS and its complement, DQS#. This distinction in timing methods is guaranteed by design and characterization. Note that when differential data strobe mode is disabled via the EMRS, the complementary pin, DQS#, must be tied externally to VSS through a 20 Ω to 10 KΩresistor to insure proper operation. z Burst write operation The Burst Write command is initiated by having CS#, CAS# and WE# LOW while holding RAS# HIGH at the rising edge of the clock. The address inputs determine the starting column address. Write latency (WL) is defined by a Read latency (RL) minus one and is equal to (AL + CL -1);and is the number of clocks of delay that are required from the time the Write command is registered to the clock edge associated to the first DQS strobe. A data strobe signal (DQS) should be driven LOW (preamble) one clock prior to the WL. The first data bit of the burst cycle must be applied to the DQ pins at the first rising edge of the DQS following the preamble. The tDQSS specification must be satisfied for each positive DQS transition to its associated clock edge during write cycles. The subsequent burst bit data are issued on successive edges of the DQS until the burst length is completed, which is 4 or 8 bit burst. When the burst has finished, any additional data supplied to the DQ pins will be ignored. The DQ Signal is ignored after the burst write operation is complete. The time from the completion of the burst Write to bank precharge is the write recovery time (WR). DDR2 SDRAM pin timings are specified for either single ended mode or differential mode depending on the setting of the EMRS “Enable DQS” mode bit; timing advantages of differential mode are realized in system design. The method by which the DDR2 SDRAM pin timings are measured is mode dependent. In single ended mode, timing relationships are measured relative to the rising or falling edges of DQS crossing at the specified AC/DC levels. In differential mode, these timing relationships are measured relative to the crosspoint of DQS and its complement, DQS#. This distinction in timing methods is guaranteed by design and characterization. Note that when differential data strobe mode is disabled via the EMRS, the complementary pin, DQS#, must be tied externally to VSS through a 20Ω to 10KΩ resistor to insure proper operation. Etron Confidential 15 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE z Write data mask One Write data mask (DM) pin for each 8 data bits (DQ) will be supported on DDR2 SDRAMs, Consistent with the implementation on DDR SDRAMs. It has identical timings on Write operations as the data bits, and though used in a uni-directional manner, is internally loaded identically to data bits to insure matched system timing. DM is not used during read cycles. z Precharge operation The Precharge command is used to precharge or close a bank that has been activated. The Precharge Command is triggered when CS#, RAS# and WE# are LOW and CAS# is HIGH at the rising edge of the clock. The Precharge Command can be used to precharge each bank independently or all banks simultaneously. Three address bits A10, BA2, BA1, and BA0 are used to define which bank to precharge when the command is issued. Table 11. Bank Selection for Precharge by address bits A10 BA2 BA1 BA0 Precharged Bank(s) LOW LOW LOW LOW Bank 0 only LOW LOW LOW HIGH Bank 1 only LOW LOW HIGH LOW Bank 2 only LOW LOW HIGH HIGH Bank 3 only LOW HIGH LOW LOW Bank 4 only LOW HIGH LOW HIGH Bank 5 only LOW HIGH HIGH LOW Bank 6 only LOW HIGH HIGH HIGH Bank 7 only HIGH DON’T CARE DON’T CARE DON’T CARE ALL Banks z Burst read operation followed by precharge Minimum Read to precharge command spacing to the same bank = AL + BL/2 + max (RTP, 2) - 2 clocks. For the earliest possible precharge, the precharge command may be issued on the rising edge which “Additive latency (AL) + BL/2 clocks” after a Read command. A new bank active (command) may be issued to the same bank after the RAS# precharge time (tRP). A precharge command cannot be issued until tRAS is satisfied. The minimum Read to Precharge spacing has also to satisfy a minimum analog time from the rising clock edge that initiates the last 4-bit prefetch of a Read to Precharge command. This time is called tRTP (Read to Precharge). For BL = 4 this is the time from the actual read (AL after the Read command) to Precharge command. For BL = 8 this is the time from AL + 2 clocks after the Read to the Precharge command. z Burst Write operation followed by precharge Minimum Write to Precharge command spacing to the same bank = WL + BL/2 + tWR. For write cycles, a delay must be satisfied from the completion of the last burst write cycle until the Precharge command can be issued. This delay is known as a write recovery time (tWR) referenced from the completion of the burst write to the Precharge command. No Precharge command should be issued prior to the tWR delay, as DDR2 SDRAM does not support any burst interrupt by a Precharge command. tWR is an analog timing parameter and is not the programmed value for tWR in the MRS. Etron Confidential 16 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE z Auto precharge operation Before a new row in an active bank can be opened, the active bank must be precharged using either the Precharge Command or the auto-precharge function. When a Read or a Write Command is given to the DDR2 SDRAM, the CAS# timing accepts one extra address, column address A10, to allow the active bank to automatically begin precharge at the earliest possible moment during the burst read or write cycle. If A10 is LOW when the READ or WRITE Command is issued, then normal Read or Write burst operation is executed and the bank remains active at the completion of the burst sequence. If A10 is HIGH when the Read or Write Command is issued, then the auto-precharge function is engaged. During auto-precharge, a Read Command will execute as normal with the exception that the active bank will begin to precharge on the rising edge which is CAS latency (CL) clock cycles before the end of the read burst. Auto-precharge also be implemented during Write commands. The precharge operation engaged by the Auto precharge command will not begin until the last data of the burst write sequence is properly stored in the memory array. This feature allows the precharge operation to be partially or completely hidden during burst Read cycles (dependent upon CAS latency) thus improving system performance for random data access. The RAS# lockout circuit internally delays the Precharge operation until the array restore operation has been completed (tRAS satisfied) so that the auto precharge command may be issued with any Read or Write command. z Burst read with auto precharge If A10 is HIGH when a Read Command is issued, the Read with Auto-Precharge function is engaged. The DDR2 SDRAM starts an Auto-Precharge operation on the rising edge which is (AL + BL/2) cycles later from the Read with AP command if tRAS(min) and tRTP are satisfied. If tRAS(min) is not satisfied at the edge, the start point of Auto-Precharge operation will be delayed until tRAS(min) is satisfied. If tRTP(min) is not satisfied at the edge, the start point of Auto-precharge operation will be delayed until tRTP(min) is satisfied. In case the internal precharge is pushed out by tRTP, tRP starts at the point where the internal precharge happens (not at the next rising clock edge after this event). So for BL = 4 the minimum time from Read with Auto-Precharge to the next Activate command becomes AL + tRTP + tRP. For BL = 8 the time from Read with Auto-Precharge to the next Activate command is AL + 2 + tRTP + tRP. Note that both parameters tRTP and tRP have to be rounded up to the next integer value. In any event internal precharge does not start earlier than two clocks after the last 4-bit prefetch. A new bank active (command) may be issued to the same bank if the following two conditions are satisfied simultaneously: (1) The RAS# precharge time (tRP) has been satisfied from the clock at which the Auto-Precharge begins. (2) The RAS# cycle time (tRC) from the previous bank activation has been satisfied. z Burst write with auto precharge If A10 is HIGH when a Write Command is issued, the Write with Auto-Precharge function is engaged. The DDR2 SDRAM automatically begins precharge operation after the completion of the burst write plus Write recovery time (tWR). The bank undergoing auto-precharge from the completion of the write burst may be reactivated if the following two conditions are satisfied. (1) The data-in to bank activate delay time (WR + tRP) has been satisfied. (2) The RAS# cycle time (tRC) from the previous bank activation has been satisfied. Etron Confidential 17 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Table 12. Precharge & Auto Precharge Clariification Minimum Delay between “From Unit Note Command” to “To Command” Precharge (to same Bank as Read) AL+BL/2+max(RTP,2)-2 Read tCK 1,2 Precharge All AL+BL/2+max(RTP,2)-2 Precharge (to same Bank as Read w/AP) AL+BL/2+max(RTP,2)-2 tCK 1,2 Read w/AP Precharge All AL+BL/2+max(RTP,2)-2 Precharge (to same Bank as Write) WL+BL/2+tWR Write tCK 2 Precharge All WL+BL/2+tWR Precharge (to same Bank as Write w/AP) WL+BL/2+tWR Write w/AP tCK 2 Precharge All WL+BL/2+tWR Precharge (to same Bank as Precharge) 1 tCK Precharge 2 Precharge All 1 Precharge 1 Precharge All tCK 2 Precharge All 1 NOTE 1: RTP [cycles] =RU {tRTP [ns]/tCK (avg) [ns]}, where RU stands for round up. NOTE 2: For a given bank, the precharge period should be counted from the latest precharge command, either one bank precharge or precharge all, issued to that bank.The prechrage period is satisfied after tRP or tRPall(=tRP for 8 bank device + 1X tCK) depending on the latest precharge command issued to that bank. From Command To Command z Refresh command When CS#, RAS# and CAS# are held LOW and WE# HIGH at the rising edge of the clock, the chip enters the Refresh mode (REF). All banks of the DDR2 SDRAM must be precharged and idle for a minimum of the Precharge time (tRP) before the Refresh command (REF) can be applied. An address counter, internal to the device, supplies the bank address during the refresh cycle. No control of the external address bus is required once this cycle has started. When the refresh cycle has completed, all banks of the DDR2 SDRAM will be in the precharged (idle) state. A delay between the Refresh command (REF) and the next Activate command or subsequent Refresh command must be greater than or equal to the Refresh cycle time (tRFC).To allow for improved efficiency in scheduling and switching between tasks, some flexibility in the absolute refresh interval is provided. A maximum of eight Refresh commands can be posted to any given DDR2 SDRAM, meaning that the maximum absolute interval between any Refresh command and the next Refresh command is 9 * tREFI. z Self refresh operation The Self Refresh command can be used to retain data in the DDR2 SDRAM, even if the rest of the system is powered down. When in the Self Refresh mode, the DDR2 SDRAM retains data without external clocking. The DDR2 SDRAM device has a built-in timer to accommodate Self Refresh operation. The Self Refresh Command is defined by having CS#, RAS#, CAS# and CKE# held LOW with WE# HIGH at the rising edge of the clock. ODT must be turned off before issuing Self Refresh command, by either driving ODT pin LOW or using EMRS command. Once the Command is registered, CKE must be held LOW to keep the device in Self Refresh mode. The DLL is automatically disabled upon entering Self Refresh and is automatically enabled upon exiting Self Refresh. When the DDR2 SDRAM has entered Self Refresh mode all of the external signals except CKE, are “don’t care”. For proper Self Refresh operation all power supply pins (VDD, VDDQ, VDDL and VREF) must be at valid levels. The DRAM initiates a minimum of one refresh command internally within tCKE period once it enters Self Refresh mode. The clock is internally disabled during Self Refresh Operation to save power. The minimum time that the DDR2 SDRAM must remain in Self Refresh mode is tCKE. The user may change the external clock frequency or halt the external clock one clock after Self Refresh entry is registered, however, the clock must be restarted and stable before the device can exit Self Refresh operation. The procedure for exiting Self Refresh requires a sequence of commands. First, the clock must be stable prior to CKE going back HIGH. Once Self Refresh Exit is registered, a delay of at least tXSNR must be satisfied before a valid command can be issued to the device to allow for any internal refresh in progress. CKE must remain HIGH for the entire Self Refresh exit period tXSRD for proper operation except for Self Refresh re-entry. Upon exit from Self Refresh, the DDR2 SDRAM can be put back into Self Refresh mode after waiting at least tXSNR period and issuing one refresh command(refresh period of tRFC). NOP or Deselect commands must be registered on each positive clock edge during the Self Refresh exit interval tXSNR. ODT should be turned off during tXSRD. The use of Self Refresh mode introduces the possibility that an internally timed refresh event can be missed when CKE is raised for exit from Self Refresh mode. Upon exit from Self Refresh, the DDR2 SDRAM requires a minimum of one extra auto refresh command before it is put back into Self Refresh mode. Etron Confidential 18 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE z Power-Down Power-down is synchronously entered when CKE is registered LOW along with NOP or Deselect command. No read or write operation may be in progress when CKE goes LOW. These operations are any of the following: read burst or write burst and recovery. CKE is allowed to go LOW while any of other operations such as row activation, precharge or autoprecharge, mode register or extended mode register command time, or autorefresh is in progress. The DLL should be in a locked state when power-down is entered. Otherwise DLL should be reset after exiting power-down mode for proper read operation. If power-down occurs when all banks are precharged, this mode is referred to as Precharge Power-down; if power-down occurs when there is a row active in any bank, this mode is referred to as Active Power-down. For Active Power-down two different power saving modes can be selected within the MRS register, address bit A12. When A12 is set to “LOW” this mode is referred as “standard active power-down mode” and a fast power-down exit timing defined by the tXARD timing parameter can be used. When A12 is set to “HIGH” this mode is referred as a power saving “LOW power active power-down mode”. This mode takes longer to exit from the power-down mode and the tXARDS timing parameter has to be satisfied. Entering power-down deactivates the input and output buffers, excluding CK, CK#, ODT and CKE. Also the DLL is disabled upon entering precharge powerdown or slow exit active power-down, but the DLL is kept enabled during fast exit active power-down. In powerdown mode, CKE LOW and a stable clock signal must be maintained at the inputs of the DDR2 SDRAM, and all other input signals are “Don’t Care”. Power-down duration is limited by 9 times tREFI of the device. The power-down state is synchronously exited when CKE is registered HIGH (along with a NOP or Deselect command). A valid, executable command can be applied with power-down exit latency, tXP, tXARD or tXARDS, after CKE goes HIGH. Power-down exit latencies are defined in the AC spec table of this data sheet. z Asynchronous CKE LOW Event DRAM requires CKE to be maintained “HIGH” for all valid operations as defined in this datasheet. If CKE asynchronously drops “LOW” during any valid peration DRAM is not guaranteed to preserve the contents of array. If this event occurs, memory controller must satisfy DRAM timing specification tDelay efore turning off the clocks. Stable clocks must exist at the input of DRAM before CKE is raised “HIGH” again. DRAM must be fully re-initialized. DRAM is ready for normal operation after the initialization sequence. z Input clock frequency change during precharge power down DDR2 SDRAM input clock frequency can be changed under following condition: DDR2 SDRAM is in precharged power down mode. ODT must be turned off and CKE must be at logic LOW level. A minimum of 2 clocks must be waited after CKE goes LOW before clock frequency may change. SDRAM input clock frequency is allowed to change only within minimum and maximum operating frequency specified for the particular speed grade. During input clock frequency change, ODT and CKE must be held at stable LOW levels. Once input clock frequency is changed, stable new clocks must be provided to DRAM before precharge power down may be exited and DLL must be RESET via EMRS after precharge power down exit. Depending on new clock frequency an additional MRS command may need to be issued to appropriately set the WR, CL etc. During DLL re-lock period, ODT must remain off. After the DLL lock time, the DRAM is ready to operate with new clock frequency. z No operation command The No Operation Command should be used in cases when the DDR2 SDRAM is in an idle or a wait state. The purpose of the No Operation Command (NOP) is to prevent the DDR2 SDRAM from registering any unwanted commands between operations. A No Operation Command is registered when CS# is LOW with RAS#, CAS#, and WE# held HIGH at the rising edge of the clock. A No Operation Command will not terminate a previous operation that is still executing, such as a burst read or write cycle. z Deselect command The Deselect Command performs the same function as a No Operation Command. Deselect Command occurs when CS# is brought HIGH at the rising edge of the clock, the RAS#, CAS#, and WE# signals become don’t cares. Etron Confidential 19 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Table 13. Absolute Maximum DC Ratings Symbol Parameter Rating Unit Note VDD Voltage on VDD pin relative to Vss -1.0 ~ 2.3 V 1,3 VDDQ Voltage on VDDQ pin relative to Vss -0.5 ~ 2.3 V 1,3 VDDL Voltage on VDDL pin relative to Vss -0.5 ~ 2.3 V 1,3 VIN, VOUT Voltage on any pin relative to Vss - 0.5 ~ 2.3 V 1,4 TSTG Storage temperature - 55~100 1,2 °C NOTE1: Stress greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the devices. This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability. NOTE2: Storage temperature is the case temperature on the center/top side of the DRAM. NOTE3: When VDD and VDDQ and VDDL are less than 500mV, Vref may be equal to or less than 300mV. NOTE4: Voltage on any input or I/O may not exceed voltage on VDDQ. Table 14. Operating Temperature Condition Symbol TOPER Parameter Industrial temperature Rating -40~95 Unit Note 1 °C NOTE1: Operating temperature is the case surface temperature on center/top of the DRAM. NOTE2: If TC exceeds 85°C, the DRAM must be refreshed externally at 2x refresh. It is required to set tREFI=3.9µs in auto refresh mode and to set ‘1’ for EMRS (2) bit A7 in self refresh mode. Table 15. Recommended DC Operating Conditions (SSTL_1.8) Symbol Parameter Unit Note Min. Typ. Max. VDD Power supply voltage 1.7 1.8 1.9 V 1 VDDL Power supply voltage for DLL 1.7 1.8 1.9 V 5 VDDQ Power supply voltage for I/O Buffer 1.7 1.8 1.9 V 1,5 VREF Input reference voltage 0.49 x VDDQ 0.5 x VDDQ 0.51 x VDDQ mV 2,3 VTT Termination voltage VREF - 0.04 VREF VREF + 0.04 V 4 NOTE1: There is no specific device VDD supply voltage requirement for SSTL_18 compliance. However under all conditions VDDQ must be less than or equal to VDD. NOTE2: The value of VREF may be selected by the user to provide optimum noise margin in the system. Typically the value of VREF is expected to be about 0.5 x VDDQ of the transmitting device and VREF is expected to track variations in VDDQ. NOTE3: Peak to peak ac noise on VREF may not exceed +/-2 % VREF (dc). NOTE4: VTT of transmitting device must track VREF of receiving device. NOTE5: VDDQ tracks with VDD, VDDL tracks with VDD. AC parameters are measured with VDD, VDDQ and VDDL tied together Etron Confidential 20 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Table 16. Input logic level (VDD = 1.8V ± 0.1V, TOPER = -40~95 °C) Symbol Parameter -18I -25I/3I Unit Min. Max. Min. Max. VREF + 0.125 VDDQ + 0.3 VREF + 0.125 VDDQ + 0.3 V VIL (DC) DC Input Low Voltage -0.3 VREF - 0.125 -0.3 VREF - 0.125 V VIH (AC) AC Input High Voltage VREF + 0.2 - VREF + 0.2 VDDQ+Vpeak V VIL (AC) AC Input Low Voltage - VREF – 0.2 VssQ –Vpeak VREF – 0.2 V VID (AC) AC Differential Voltage 0.5 VDDQ+0.6 0.5 VDDQ V VIH (DC) DC Input logic High Voltage 0.5 x VDDQ0.5 x 0.5 x 0.5 x VDDQV 0.175 VDDQ+0.175 0.175 VDDQ+0.175 NOTE1: Refer to Overshoot/undershoot specification for Vpeak value: maximum peak amplitude allowed for overshoot and undershoot. VIX (AC) AC Differential crosspoint Voltage Table 17. AC Input test conditions (VDD = 1.8V ± 0.1V, TOPER = -40~95 °C) Symbol VREF Parameter Value Input reference voltage VSWING(max) Input signal maximum peak to peak swing Unit Note 0.5 x VDDQ V 1 1.0 V 1 Slew Rate Input signal minimum slew rate 1.0 V/ns 2, 3 NOTE1: Input waveform timing is referenced to the input signal crossing through the VIH /IL (ac) level applied to the device under test. NOTE2: The input signal minimum slew rate is to be maintained over the range from VREF to VIH(ac) min for rising edges and the range from VREF to VIL (ac) max for falling edges . NOTE3: AC timings are referenced with input waveforms switching from VIL (ac) to VIH (ac) on the positive transitions and VIH (ac) to VIL (ac) on the negative transitions. Table 18. Differential AC output parameters (VDD = 1.8V ± 0.1V, TOPER = -40~95 °C) Symbol Value Parameter Min. Unit Note Max. Vox(ac) AC Differential Cross Point Voltage 0.5xVDDQ-0.125 0.5xVDDQ+0.125 V 1 NOTE1: The typical value of VOX (ac) is expected to be about 0.5 x VDDQ of the transmitting device and VOX (ac) is expected to track variations in VDDQ. VOX (ac) indicates the voltage at which differential output signals must cross. Table 19. AC overshoot/undershoot specification for address and control pins (A0-A12, BA0-BA2, CS#, RAS#, CAS#, WE#, CKE, ODT) Parameter -18I -25I -3I Unit Maximum peak amplitude allowed for overshoot area 0.5 0.5 0.5 V Maximum peak amplitude allowed for undershoot area 0.5 0.5 0.5 V Maximum overshoot area above VDD 0.5 0.66 0.8 V-ns Maximum undershoot area below VSS 0.5 0.66 0.8 V-ns Etron Confidential 21 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Table 20. AC overshoot/undershoot specification for clock, data, strobe, and mask pins (DQ, UDQS, LDQS, UDQS#, LDQS#, DM, CK, CK#) Parameter -18I -25I -3I Unit Maximum peak amplitude allowed for overshoot area 0.5 0.5 0.5 V Maximum peak amplitude allowed for undershoot area 0.5 0.5 0.5 V Maximum overshoot area above VDD 0.19 0.23 0.23 V-ns Maximum undershoot area below VSS 0.19 0.23 0.23 V-ns Table 21. Output AC test conditions (VDD = 1.8V ± 0.1V, TOPER = -40~95 °C) Symbol Parameter Rating Unit Note VOTR Output timing measurement reference level 0.5xVDDQ V 1 SSTL_18 Unit Note -13.4 mA 1, 3, 4 NOTE1: The VDDQ of the device under test is referenced. Table 22. Output DC current drive (VDD = 1.8V ± 0.1V, TOPER = -40~95 °C) Symbol IOH(dc) Parameter Output minimum source DC current IOL(dc) Output minimum sink DC current 13.4 mA 2, 3, 4 NOTE1: VDDQ = 1.7 V; VOUT = 1420 mV. (VOUT - VDDQ) /IOH must be less than 21 Ω for values of VOUT between VDDQ and VDDQ - 280 mV. NOTE2: VDDQ = 1.7 V; VOUT = 280 mV. VOUT/IOL must be less than 21 Ω for values of VOUT between 0 V and 280 mV. NOTE3: The dc value of VREF applied to the receiving device is set to VTT NOTE4: The values of IOH (dc) and IOL (dc) are based on the conditions given in Notes 1 and 2. They are used to test device drive current capability to ensure VIH min plus a noise margin and VIL max minus a noise margin are delivered to an SSTL_18 receiver. The actual current values are derived by shifting the desired driver operating point (see JEDEC standard: Section 3.3 of JESD8-15A) along a 21 Ω load line to define a convenient driver current for measurement. Table 23. Capacitance (VDD = 1.8V, f = 1MHz, TOPER = 25 °C) Symbol CIN CCK CI/O DCIN DCCK DCIO DDR2-1066/800 Parameter Input Capacitance : Command and Address Input Capacitance (CK, CK#) DM, DQ, DQS Input/Output Capacitance Delta Input Capacitance: Command and Address Delta Input Capacitance: CK, CK# Delta Input/Output Capacitance: DM, DQ, DQS Min. 1.0 1.0 2.5 - Max. 1.75 2.0 3.5 0.25 0.25 0.5 DDR2-667 Min. 1.0 1.0 2.5 - Max. 2.0 2.0 3.5 0.25 0.25 0.5 Unit pF pF pF pF pF pF NOTE: These parameters are periodically sampled and are not 100% tested. Etron Confidential 22 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Table 24. IDD specification parameters and test conditions (VDD = 1.8V ± 0.1V, TOPER = -40~95 °C) Parameter & Test Condition -18I -25I Max. -3I 70 60 50 mA 85 75 63 mA 10 9 9 mA 23 18 15 mA 30 25 21 mA 25 23 23 mA 20 16 16 mA 37 32 27 mA 165 130 110 mA IDD4R 150 115 96 mA IDD5 125 100 84 mA IDD6 10 9 9 mA IDD7 240 200 167 mA Symbol Operating one bank active-precharge current: tCK =tCK (min), tRC = tRC (min), tRAS = tRAS(min); CKE is HIGH, CS# is IDD0 HIGH between valid commands; Address bus inputs are SWITCHING; Data bus inputs are SWITCHING Operating one bank active-read-precharge current: IOUT = 0mA; BL = 4, CL = CL (min), AL = 0; tCK = tCK (min),tRC = tRC (min), IDD1 tRAS = tRAS(min), tRCD = tRCD (min);CKE is HIGH, CS# is HIGH between valid commands;Address bus inputs are switching; Data pattern is same as IDD4W Precharge power-down current: All banks idle;tCK =tCK (min); CKE is LOW; Other control and address bus IDD2P inputs are STABLE; Data bus inputs are FLOATING Precharge quiet standby current: IDD2Q All banks idle; tCK =tCK (min); CKE is HIGH, CS# is HIGH; Other control and address bus inputs are STABLE; Data bus inputs are FLOATING Precharge standby current: All banks idle; tCK = tCK (min); CKE is HIGH, CS# is HIGH; Other control I and address bus inputs are SWITCHING; Data bus inputs are DD2N SWITCHING Active power-down current: MRS(A12)=0 All banks open; tCK =tCK (min); CKE is LOW; Other IDD3P control and address bus inputs are STABLE; Data bus MRS(A12)=1 inputs are FLOATING Active standby current: All banks open; tCK = tCK(min), tRAS = tRAS (max), tRP = tRP (min); CKE is I HIGH, CS# is HIGH between valid commands; Other control and address DD3N bus inputs are SWITCHING; Data bus inputs are SWITCHING Operating burst write current: All banks open,continuous burst writes; BL = 4, CL = CL (min), AL = 0; tCK= tCK (min), tRAS = tRAS (max), tRP = tRP (min); CKE is HIGH, CS# is IDD4W HIGH between valid commands; Address bus inputs are switching; Data bus inputs are switching Operating burst read current: All banks open, continuous burst reads, IOUT = 0mA; BL = 4, CL = CL (min), AL = 0; tCK = tCK (min), tRAS = tRAS (max), tRP = tRP (min); CKE is HIGH, CS# is HIGH between valid commands; Address bus inputs are SWITCHING; Data bus inputs are SWITCHING Burst refresh current: tCK = tCK (min); refresh command at every tRFC (min) interval; CKE is HIGH, CS# is HIGH between valid commands; Other control and address bus inputs are SWITCHING; Data bus inputs are SWITCHING Self refresh current: CK and CK# at 0V; CKE ≤ 0.2V;Other control and address bus inputs are FLOATING; Data bus inputs are FLOATING Operating bank interleave read current: All bank interleaving reads, IOUT= 0mA; BL = 4, CL = CL (min), AL =tRCD (min) - 1 x tCK (min); tCK = tCK (min), tRC = tRC (min), tRRD = tRRD (min), tRCD = tRCD (min); CKE is HIGH, CS# is HIGH between valid commands; Address bus inputs are STABLE during DESELECTs.Data pattern is same as IDD4R Etron Confidential 23 Rev. 1.0 Unit Jan. /2014 EtronTech EM68C16CWQE Table 25. Electrical Characteristics and Recommended A.C. Operating Conditions (VDD = 1.8V ± 0.1V, TOPER = -40~95°C) Symbol tCK(avg) tCH(avg) tCL(avg) WL -18I Min. Parameter Average clock period -25I Min. Max. Min. -3I Max. Unit Specific Notes CL=4 3.75 7.5 3.75 8 3.75 8 ns CL=5 3 7.5 2.5 8 3 8 ns CL=6 2.5 7.5 2.5 8 3 8 ns CL=7 1.875 7.5 - - - - ns 0.48 0.52 0.48 0.52 0.48 0.52 tCK 15, 33, 34 15, 33, 34 15, 33, 34 15, 33, 34 34, 35 0.48 0.52 0.48 0.52 0.48 0.52 tCK 34, 35 tDSS tDSH Average clock HIGH pulse width Average Clock LOW pulse width Write command to DQS associated clock edge DQS latching rising transitions to associated clock edges DQS falling edge to CK setup time DQS falling edge hold time from CK tDQSH DQS input HIGH pulse width 0.35 - 0.35 - 0.35 - tCK tDQSL tWPRE tWPST DQS input LOW pulse width Write preamble Write postamble 0.35 - 0.35 - 0.35 - tCK 0.35 - 0.35 - 0.35 - tCK 0.4 0.6 0.4 0.6 0.4 0.6 tCK 10 tDQSS RL-1 RL-1 tCK RL-1 -0.25 0.25 -0.25 0.25 -0.25 0.25 tCK 28 0.2 - 0.2 - 0.2 - tCK 28 0.2 - 0.2 - 0.2 - tCK 0.125 - 0.175 - 0.2 - ns 5, 7, 9, 22, 27 Address and Control input hold time 0.2 - 0.25 - 0.275 - ns 5, 7, 9, 23, 27 tIPW Control & Address input pulse width for each input 0.6 - 0.6 - 0.6 - tCK tDS(base) DQ & DM input setup time 0 - 0.05 - 0.1 - ns 6-8, 20, 26, 29 tDH(base) DQ & DM input hold time 0.075 - 0.125 - 0.175 - ns 6-8, 21, 26, 29 tDIPW tAC tDQSCK tHZ tLZ(DQS) tLZ(DQ) 0.35 - 0.35 - 0.35 - tCK tDQSQ DQ and DM input pulse width for each input DQ output access time from CK, CK# DQS output access time from CK, CK# Data-out high-impedance time from CK, CK# DQS(DQS#) low-impedance time from CK, CK# DQ low-impedance time from CK, CK# DQS-DQ skew for DQS and associated DQ signals tHP CK half pulse width tQHS tQH tRPRE tRPST tRRD tFAW tCCD tWR tDAL tWTR tRTP tCKE tXSNR tXSRD DQ hold skew factor DQ/DQS output hold time from DQS Read preamble Read postamble Active to active command period Four Activate Window CAS# to CAS# command delay Write recovery time Auto Power write recovery + precharge time Internal Write to Read Command Delay Internal read to precharge command delay CKE minimum pulse width Exit self refresh to non-read command delay Exit self refresh to a read command tIS(base) Address and Control input setup time tIH(base) Etron Confidential 24 -0.35 0.35 -0.4 0.4 -0.45 0.45 ns 38 -0.325 0.325 -0.35 0.35 -0.4 0.4 ns 38 - tAC(max) - tAC(max) - tAC(max) ns 18, 38 tAC(min) tAC(max) tAC(min) tAC(max) tAC(min) tAC(max) ns 18, 38 2tAC(min) tAC(max) 2tAC(min) tAC(max) 2tAC(min) tAC(max) ns 18, 38 - 0.175 - 0.2 - 0.24 ns 13 min (tCH,tCL) - min (tCH,tCL) - min (tCH,tCL) - ns 11, 12, 35 - 0.25 - 0.3 - 0.34 ns 12, 36 tHP -tQHS - tHP -tQHS - tHP -tQHS - ns 37 0.9 1.1 0.9 1.1 0.9 1.1 tCK 19, 39 0.4 0.6 0.4 0.6 0.4 0.6 tCK 19, 40 10 - 10 - 10 - ns 4, 30 45 - 45 - 50 - ns 4, 30 2 - 2 - 2 - tCK 15 - 15 - 15 - ns WR + tRP - WR + tRP - WR + tRP - ns 14, 31 7.5 - 7.5 - 7.5 - ns 3, 24, 30 7.5 - 7.5 - 7.5 - ns 3, 30 30 3 - 3 - 3 - tCK 25 tRFC+10 - tRFC+10 - tRFC+10 - ns 30 200 - 200 - 200 - tCK Rev. 1.0 Jan. /2014 EtronTech tXP tXARD tXARDS tAOND EM68C16CWQE Exit precharge power down to any command Exit active power down to read command Exit active power down to read command(slow exit, lower power) ODT turn-on delay tAON ODT turn-on tAONPD ODT turn-on (Power-Down mode) tAOFD ODT turn-off delay ODT turn-off tAOFPD ODT turn-off (Power-Down mode) tANPD tAXPD tMRD tMOD ODT to power down entry latency ODT power down exit latency Mode register set command cycle time MRS command to ODT update delay Minimum time clocks remains ON after CKE asynchronously drops LOW Refresh to active/Refresh command time tRFC tREFI Average periodic refesh interval tRCD tRP tRC tRAS RAS# to CAS# Delay time Row precharge Delay time Row cycle Delay time Row active Delay time Etron Confidential - 2 - 2 - tCK 2 - 2 - 2 - tCK 1 10-AL - 8-AL - 7-AL - tCK 1, 2 2 2 2 2 2 2 tCK 16 tAC(min) tAC(max)+2. 575 tAC(min) tAC(max)+0. 7 tAC(min) tAC(max)+0. ns 7 3 tCK 2 tCK 2 tCK tAC(min)+2 +tAC(max)+ tAC(min)+2 +tAC(max)+ tAC(min)+2 +tAC(max)+ 1 1 1 tAOF tDelay 3 2.5 2.5 tAC(min) tAC(max)+0. 6 2.5 2.5 tAC(min) tAC(max)+0. 6 2.5 tAC(min) 2.5 6, 16, 38 ns tCK 17, 42 tAC(max)+0. ns 6 17, 41, 42 2.5 tCK 2.5 tCK 2.5 tCK tAC(min)+2 +tAC(max)+ tAC(min)+2 +tAC(max)+ tAC(min)+2 +tAC(max)+ 1 1 1 ns 4 - 3 - 3 - tCK 11 - 8 - 8 - tCK 2 - 2 - 2 - tCK 0 12 0 12 0 12 ns 30 - tIS+ tCK +tIH - tIS+ tCK +tIH - ns 15 127.5 tIS+ tCK +tIH 127.5 - - 127.5 - ns 43 @ -40℃ to +85℃ - 7.8 7.8 - 7.8 µs 43 @ +85℃ to 95℃ - 3.9 3.9 - 3.9 µs 43 13.125 - 12.5 - 15 - ns 13.125 - 12.5 - 15 - ns 58.125 - 57.5 - 60 - ns 45 70K 45 70K 45 70K ns 25 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE General notes, which may apply for all AC parameters: NOTE 1: DDR2 SDRAM AC timing reference load The below figure represents the timing reference load used in defining the relevant timing parameters of the part. It is not intended to be either a precise representation of the typical system environment or a depiction of the actual load presented by a production tester. Figure 5. AC timing reference load VDDQ DQ DUT DQS Ouput 25Ω DQS# VTT=VDDQ/2 Timing reference point The output timing reference voltage level for single ended signals is the crosspoint with VTT. The output timing reference voltage level for differential signals is the crosspoint of the true (e.g. DQS) and the complement (e.g. DQS#) signal. NOTE 2: Slew Rate Measurement Levels a) Output slew rate for falling and rising edges is measured between VTT - 250 mV and VTT + 250 mV for single ended signals. For differential signals (e.g. DQS – DQS#) output slew rate is measured between DQS – DQS# = - 500 mV and DQS – DQS# = + 500 mV. Output slew rate is guaranteed by design, but is not necessarily tested on each device. b) Input slew rate for single ended signals is measured from VREF (dc) to VIH (ac), min for rising edges and from VREF(dc) to VIL(ac),max for falling edges.For differential signals (e.g. CK – CK#) slew rate for rising edges is measured from CK – CK# = - 250 mV to CK -CK# = + 500 mV (+ 250 mV to - 500 mV for falling edges). c) VID is the magnitude of the difference between the input voltage on CK and the input voltage on CK#, or betweenDQS and DQS# for differential strobe. NOTE 3: DDR2 SDRAM output slew rate test load Output slew rate is characterized under the test conditions as bellow Figure 6. Slew rate test load VDDQ DQ DUT DQS Ouput 25Ω DQS# VTT=VDDQ/2 Test point Etron Confidential 26 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE NOTE 4: Differential data strobe DDR2 SDRAM pin timings are specified for either single ended mode or differential mode depending on the setting of the EMRS “Enable DQS” mode bit; timing advantages of differential mode are realized in system design. The method by which the DDR2 SDRAM pin timings are measured is mode dependent. In single ended mode, timing relationships are measured relative to the rising or falling edges of DQS crossing at VREF. In differential mode, these timing relationships are measured relative to the crosspoint of DQS and its complement, DQS#. This distinction in timing methods is guaranteed by design and characterization. Note that when differential data strobe mode is disabled via the EMRS, the complementary pin, DQS#, must be tied externally to VSS through a 20 Ω to 10 kΩ resistor to insure proper operation NOTE 5: AC timings are for linear signal transitions. NOTE 6:All voltages are referenced to VSS. NOTE 7: These parameters guarantee device behavior, but they are not necessarily tested on each device.They may be guaranteed by device design or tester correlation NOTE 8: Tests for AC timing, IDD, and electrical (AC and DC) characteristics, may be conducted at nominal reference/supply voltage levels, but the related specifications and device operation are guaranteed for the full voltage range specified. Specific notes for dedicated AC parameters NOTE 1:User can choose which active power down exit timing to use via MRS (bit 12). tXARD is expected to be used for fast active power down exit timing. tXARDS is expected to be used for slow active power down exit timing where a lower power value is defined by each vendor data sheet. NOTE 2: AL=Additive Latency. NOTE 3:This is a minimum requirement. Minimum read to precharge timing is AL+BL/2 provided that the tRTP and tRAS (min) have been satisfied. NOTE 4: A minimum of two clocks (2* tCK) is required irrespective of operating frequency. NOTE 5: Timings are specified with command/address input slew rate of 1.0 V/ns. NOTE 6:Timings are specified with DQs, DM, and DQS’s (in single ended mode) input slew rate of 1.0V/ns. NOTE 7:Timings are specified with CK/CK# differential slew rate of 2.0 V/ns. Timings are guaranteed for DQS signals with a differential slew rate of 2.0 V/ns in differential strobe mode and a slew rate of 1 V/ns in single ended mode. NOTE 8:Data setup and hold time derating. For all input signals the total tDS (setup time) and tDH (hold time) required is calculated by adding the data sheet. tDS(base) and tDH(base) value to the ∆tDS and ∆tDH derating value respectively. Example: tDS (total setup time) =tDS (base) + ∆tDS.For slew rates in between the values listed in Tables 26, the derating values may obtained by linear interpolation.These values are typically not subject to production test. They are verified by design and characterization. Table 26. DDR2-667/800/1066 tDS/tDH derating with differential data strobe △tDS, △tDH derating values for DD2-667/800/1066 (All units in ‘ps’; the note applies to the entire table) DQS,DQS# Differential Slew Rate 4.0 V/ns 3.0 V/ns 2.0 V/ns 1.8 V/ns 1.6 V/ns 1.4 V/ns 1.2 V/ns 1.0 V/ns △tD S DQ Slew Rate V/ns 2.0 1.5 1.0 0.9 0.8 0.7 0.6 0.5 0.4 △tD H △tD S 100 45 67 21 0 0 0 0 - - -5 -14 - - - - -13 -31 - - - - - - - - - - - - - - - - - - - - - - Etron Confidential △tD H △tD S △tD H △tD S 100 45 100 45 - - - - - - - - - - - - 67 21 67 21 79 33 - - - - - - - - - - 0 0 12 12 24 24 - - - - - - - - -5 -14 7 -2 19 10 31 22 - - - - - - -1 -19 11 -7 23 5 35 17 - - - - -10 -42 2 -30 14 -18 26 -6 38 6 - - - - -10 -59 2 -47 14 -35 26 -23 38 -11 - - - - - -24 -89 -12 -77 0 -65 12 -53 - - - - - - - -52 -140 -40 -128 -28 -116 27 △tD S △tD H △tD S △tD H △tD S △tD H Rev. 1.0 △tD S 0.8 V/ns △tD H △tD H △tD S △tD H Jan. /2014 EtronTech EM68C16CWQE NOTE 9:tIS and tIH (input setup and hold) derating For all input signals the total tIS (setup time) and tIH (hold time) required is calculated by adding the data sheet tIS(base) and tIH(base) value to the ∆tIS and ∆tIH derating value respectively. Example: tIS (total setup time) = tIS(base) + ∆tIS For slew rates in between the values listed in Tables 27, the derating values may obtained by linear interpolation.These values are typically not subject to production test. They are verified by design and characterization Table 27. Derating values for DDR2-667/800/1066 Command/ Address Slew rate (V/ns) 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.25 0.2 0.15 0.1 △tIS and △tIH Derating Values for DR2-667/800/1066 CK,CK# Differential Slew Rate 2.0 V/ns 1.5 V/ns 1.0 V/ns △tIS △tIH △tIS △tIH △tIS △tIH +150 +94 +180 +124 +210 +154 +143 +89 +173 +119 +203 +149 +133 +83 +163 +113 +193 +143 +120 +75 +150 +105 +180 +135 +100 +45 +130 +75 +160 +105 +67 +21 +97 +51 +127 +81 0 0 +30 +30 +60 +60 -5 -14 +25 +16 +55 +46 -13 -31 +17 -1 +47 +29 -22 -54 +8 -24 +38 +6 -34 -83 -4 -53 +26 -23 -60 -125 -30 -95 0 -65 -100 -188 -70 -158 -40 -128 -168 -292 -138 -262 -108 -232 -200 -375 -170 -345 -140 -315 -325 -500 -295 -470 -265 -440 -517 -708 -487 -678 -457 -648 -1000 -1125 -970 -1095 -940 -1065 Units ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps ps Notes 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 NOTE 10: The maximum limit for this parameter is not a device limit. The device will operate with a greater value for this parameter, but system performance (bus turnaround) will degrade accordingly. NOTE 11: MIN (tCL, tCH) refers to the smaller of the actual clock LOW time and the actual clock HIGH time as provided to the device (i.e. this value can be greater than the minimum specification limits for tCL and tCH). NOTE 12: tQH = tHP – tQHS, where: tHP = minimum half clock period for any given cycle and is defined by clock HIGH or clock LOW (tCH, tCL). tQHS accounts for: 1) The pulse duration distortion of on-chip clock circuits; and 2) The worst case push-out of DQS on one transition followed by the worst case pull-in of DQ on the next transition, both of which are, separately, due to data pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers. NOTE 13: tDQSQ: Consists of data pin skew and output pattern effects, and p-channel to n-channel variation of the output drivers as well as output slew rate mismatch between DQS / DQS# and associated DQ in any given cycle. NOTE 14: tDAL = WR + RU{ tRP[ns] / tCK[ns] }, where RU stands for round up.WR refers to the tWR parameter stored in the MRS. For tRP, if the result of the division is not already an integer, round up to the next highest integer. tCK refers to the application clock period. NOTE 15: The clock frequency is allowed to change during self–refresh mode or precharge power-down mode. In case of clock frequency change during precharge power-down. NOTE 16: ODT turn on time min is when the device leaves high impedance and ODT resistance begins to turn on. ODT turn on time max is when the ODT resistance is fully on. Both are measured from tAOND, which is interpreted differently per speed bin. For DDR2- 667/800/1066, tAOND is 2 clock cycles after the clock edge that registered a first ODT HIGH counting the actual input clock edges. Etron Confidential 28 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE NOTE 17: ODT turn off time min is when the device starts to turn off ODT resistance. ODT turn off time max is when the bus is in high impedance. Both are measured from tAOFD, which is interpreted differently per speed bin. For DDR2-667/800/1066, if tCK(avg) = 3 ns is assumed, tAOFD is 1.5 ns (= 0.5 x 3 ns) after the second trailing clock edge counting from the clock edge that registered a first ODT LOW and by counting the actual input clock edges. NOTE 18: tHZ and tLZ transitions occur in the same access time as valid data transitions. These parameters are referenced to a specific voltage level which specifies when the device output is no longer driving (tHZ), or begins driving (tLZ). NOTE 19: tRPST end point and tRPRE begin point are not referenced to a specific voltage level but specify when the device output is no longer driving (tRPST), or begins driving (tRPRE). The actual voltage measurement points are not critical as long as the calculation is consistent. NOTE 20: Input waveform timing tDS with differential data strobe enabled MR[bit10]=0, is referenced from the input signal crossing at the VIH(ac) level to the differential data strobe crosspoint for a rising signal, and from the input signal crossing at the VIL(ac) level to the differential data strobe crosspoint for a falling signal applied to the device under test. DQS, DQS# signals must be monotonic between VIL(dc)max and VIH(dc)min. NOTE 21: Input waveform timing tDH with differential data strobe enabled MR[bit10]=0, is referenced from the differential data strobe crosspoint to the input signal crossing at the VIH(dc) level for a falling signal and from the differential data strobe crosspoint to the input signal crossing at the VIL(dc) level for a rising signal applied to the device under test. DQS, DQS# signals must be monotonic between VIL(dc)max and VIH(dc)min. NOTE 22: Input waveform timing is referenced from the input signal crossing at the VIH(ac) level for a rising signal and VIL(ac) for a falling signal applied to the device under test. NOTE 23: Input waveform timing is referenced from the input signal crossing at the VIL(dc) level for a rising signal and VIH(dc) for a falling signal applied to the device under test. NOTE 24: tWTR is at lease two clocks (2 x tCK ) independent of operation frequency. NOTE 25: tCKEmin of 3 clocks means CKE must be registered on three consecutive positive clock edges. CKE must remain at the valid input level the entire time it takes to achieve the 3 clocks of registration. Thus, after any CKE transition, CKE may not transition from its valid level during the time period of tIS + 2 x tCK + tIH. NOTE 26: If tDS or tDH is violated, data corruption may occur and the data must be re-written with valid data before a valid READ can be executed. NOTE 27: These parameters are measured from a command/address signal (CKE, CS#, RAS#, CAS#, WE#, ODT, BA0, A0, A1, etc.) transition edge to its respective clock signal (CK/CK#) crossing. The spec values are not affected by the amount of clock jitter applied (i.e. tJIT(per), tJIT(cc), etc.), as the setup and hold are relative to the clock signal crossing that latches the command/address. That is, these parameters should be met whether clock jitter is present or not. NOTE 28: These parameters are measured from a data strobe signal (LDQS/UDQS) crossing to its respective clock signal (CK/CK#) crossing. The spec values are not affected by the amount of clock jitter applied (i.e. tJIT(per), tJIT(cc), etc.), as these are relative to the clock signal crossing. That is, these parameters should be met whether clock jitter is present or not. NOTE 29: These parameters are measured from a data signal ((L/U) DM, (L/U) DQ0, (L/U) DQ1, etc.) transition edge to its respective data strobe signal (LDQS/UDQS/LDQS#/UDQS#) crossing. NOTE 30: For these parameters, the DDR2 SDRAM device is characterized and verified to support tnPARAM = RU{tPARAM / tCK(avg)}, which is in clock cycles, assuming all input clock jitter specifications are satisfied. NOTE 31: tDAL [tCK] = WR [tCK] + tRP [tCK] = WR + RU {tRP [ps] / tCK(avg) [ps] }, where WR is the value programmed in the mode register set. NOTE 32: New units, ‘tCK(avg)’ is introduced in DDR2-667, DDR2-800 and DDR2-1066. Unit ‘tCK(avg)’ represents the actual tCK(avg) of the input clock under operation. NOTE 33: Input clock jitter spec parameter. These parameters and the ones in the table below are referred to as 'input clock jitter spec parameters' and these parameters apply to DDR2-667, DDR2-800 and DDR2-1066 only. The jitter specified is a random jitter meeting a Gaussian distribution. Etron Confidential 29 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Table 28. Input clock jitter spec parameter Parameter Symbol Clock period jitter Clock period jitter during DLL locking period Cycle to cycle clock period jitter Cycle to cycle clock period jitter during DLL locking period Cumulative error across 2 cycles Cumulative error across 3 cycles Cumulative error across 4 cycles Cumulative error across 5 cycles -18I -25I -3I Min. Max. Min. Max. Min. Max. Units Notes tJIT (per) -90 90 -100 100 -125 125 ps 33 tJIT (per,lck) -80 80 -80 80 -100 100 ps 33 tJIT (cc) -180 180 -200 200 -250 250 ps 33 tJIT (cc,lck) -160 160 -160 160 -200 200 ps 33 tERR (2per) -132 132 -150 150 -175 175 ps 33 tERR (3per) -157 157 -175 175 -225 225 ps 33 tERR (4per) -175 175 -200 200 -250 250 ps 33 tERR (5per) -188 188 -200 200 -250 250 ps 33 -250 250 -300 300 -350 350 ps 33 -425 425 -450 450 -450 450 ps 33 -75 75 -100 100 -125 125 ps 33 Cumulative error across n cycles, n=6...10, tERR (6-10per) inclusive Cumulative error across n cycles, tERR (11-50per) n=11...50, inclusive Duty cycle jitter tJIT (duty) NOTE 34: These parameters are specified per their average values, however it is understood that the following relationship between the average timing and the absolute instantaneous timing holds at all times. (Min andmax of SPEC values are to be used for calculations in the table below.) Table 29. Absolute clock period average values Parameter Absolute clock period Symbol tCK (abs) Min. tCK(avg),min + tJIT(per),min Max. tCK(avg),max + tJIT(per),max Unit ps Absolute clock HIGH pulse width tCH (abs) tCL (abs) tCH(avg),max * tCK(avg),max + tJIT(duty),max tCL(avg), max * tCK(avg),max + tJIT(duty), max ps Absolute clock LOW pulse width tCH(avg),min * tCK(avg),min + tJIT(duty),min tCL(avg),min * tCK(avg),min + tJIT(duty),min ps NOTE 35: tHP is the minimum of the absolute half period of the actual input clock. tHP is an input parameter but not an input specification parameter. It is used in conjunction with tQHS to derive the DRAM output timing tQH. The value to be used for tQH calculation is determined by the following equation; tHP = Min ( tCH(abs), tCL(abs) ), where, tCH(abs) is the minimum of the actual instantaneous clock HIGH time; tCL(abs) is the minimum of the actual instantaneous clock LOW time; NOTE 36: tQHS accounts for: 1) The pulse duration distortion of on-chip clock circuits, which represents how well the actual tHP at the input is transferred to the output; and 2) The worst case push-out of DQS on one transition followed by the worst case pull-in of DQ on the next transition, both of which are independent of each other, due to data pin skew, output pattern effects, and pchannel to n-channel variation of the output drivers Etron Confidential 30 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE NOTE 37: tQH = tHP – tQHS, where: tHP is the minimum of the absolute half period of the actual input clock; and tQHS is the specification value under the max column. {The less half-pulse width distortion present, the larger the tQH value is; and the larger the valid data eye will be.} NOTE 38: When the device is operated with input clock jitter, this parameter needs to be derated by the actual tERR(6-10per) of the input clock. (output deratings are relative to the SDRAM input clock.) NOTE 39: When the device is operated with input clock jitter, this parameter needs to be derated by the actual tJIT(per) of the input clock. (output deratings are relative to the SDRAM input clock.) NOTE 40: When the device is operated with input clock jitter, this parameter needs to be derated by the actual tJIT(duty) of the input clock. (output deratings are relative to the SDRAM input clock.) NOTE 41: When the device is operated with input clock jitter, this parameter needs to be derated by { tJIT(duty),max - tERR(6-10per),max } and { - tJIT(duty),min - tERR(6-10per),min } of the actual input clock. (output deratings are relative to the SDRAM input clock.) NOTE 42: For tAOFD of DDR2-667/800/1066, the 1/2 clock of tCK in the 2.5 x tCK assumes a tCH(avg), average input clock HIGH pulse width of 0.5 relative to tCK(avg). tAOF,min and tAOF,max should each be derated by the same amount as the actual amount of tCH(avg) offset present at the DRAM input with respect to 0.5. NOTE 43: If refresh timing is violated, data corruption may occur and the data must be re-writtern with valid data before a valid READ can be executed. Etron Confidential 31 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Timing Waveforms Figure 7. Initialization sequence after power-up tCH tCL CK CK# tIS CKE tIS ODT Command EMR S PRE ALL NOP tRP 400ns PRE ALL MRS tMRD DLL ENABLE tMRD REF tRP REF tRFC tRFC DLL RESET EMR S EMR S MRS tMRD min 200 Cycle Follow OCD Flowchart ANY CMD t OIT OCD CAL.MOD E EXIT OCD Default NOTE 1: To guarantee ODT off, VREF must be valid and a LOW level must be applied to the ODT pin. Figure 8. ODT update delay timing-tMOD CMD EMRS NOP NOP NOP NOP NOP CK# CK ODT tIS tAOFD Rtt tMOD, min Old setting tMOD, max Updating New setting NOTE 1: To prevent any impedance glitch on the channel, the following conditions must be met: - tAOFD must be met before issuing the EMRS command. - ODT must remain LOW for the entire duration of tMOD window, until tMOD, max is met. then the ODT is ready for normal operation with the new setting, and the ODT signal may be raised again to turned on the ODT. NOTE 2: EMRS command directed to EMR(1), which updates the information in EMR(1)[A6,A2], i.e. Rtt (Nominal). NOTE 3: "setting" in this diagram is the Register and I/O setting, not what is measured from outside. Figure 9. ODT update delay timing-tMOD, as measured from outside CK# CK CMD EMRS NOP ODT NOP tIS tAOFD Rtt NOP NOP NOP tAOND tMOD, max New setting Old setting NOTE 1: EMRS command directed to EMR(1), which updates the information in EMR(1)[A6,A2], i.e. Rtt (Nominal). NOTE 2: "setting" in this diagram is measured from outside. Etron Confidential 32 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 10. ODT timing for active standby mode T0 T1 T3 T2 T4 T5 T6 CK# CK tIS CKE tIS tIS VIH(ac) VIL(ac) ODT tAOND Internal Term Res. tAOFD RTT tAON,min tAOF,min tAON,max tAOF,max Figure 11. ODT timing for power-down mode T0 T1 T3 T2 T4 T5 T6 CK# CK CKE tIS tIS VIH(AC) VIL(AC) ODT tAOFPD,max tAOFPD,min Internal Term Res. Etron Confidential RTT tAONPD,min tAONPD,max 33 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 12. ODT timing mode switch at entering power-down mode T-5 CK# T-4 T-3 T-2 CK T-1 tANPD T0 T1 T2 T3 T4 tIS CKE Entering Slow Exit Active Power Down Mode or Precharge Power Down Mode. ODT tIS VIL(ac) tAOFD Internal Term Res. Active & Standby mode timings to be applied. RTT tIS ODT VIL(ac) Power Down mode timings to be applied. tAOFPD max Internal Term Res. RTT tIS VIH(ac) ODT tAOND RTT Internal Term Res. VIH(ac) ODT tIS tAONPD max RTT Internal Term Res. Etron Confidential Active & Standby mode timings to be applied. 34 Power Down mode timings to be applied. Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 13.ODT timing mode switch at exit power-down mode T0 CK# CK VIH(ac) T1 T4 T5 T6 T7 T8 T9 T10 T11 tAXPD tIS CKE Exiting from Slow Active Power Down Mode or Precharge power Down Mode. tIS ODT Active & Standby mode timings to be applied. VIL(ac) tAOFD Internal Term Res. RTT tIS ODT Power Down mode timings to be applied. VIL(ac) tAOFPD max Internal Term Res. RTT tIS Active & Standby mode timings to be applied. VIH(ac) ODT tAOND RTT Internal Term Res. VIH(ac) Power Down mode timings to be applied. tIS ODT tAONPD max Internal Term Res. RTT Figure 14. Bank activate command cycle (tRCD=3, AL=2, tRP=3, tRRD=2, tCCD=2) T0 T1 T3 T2 Tn Tn+1 Tn+2 Tn+3 CK# CK ADDRESS Internal RAS# - CAS# delay (>=tRCD min) Bank A Row Addr. tRCD = 1 Bank A Col. Addr. Bank A Activate Bank A Addr. Bank B Addr. Bank A Row Addr. Bank A Precharge Bank B Precharge Bank A Activate CAS# - CAS# delay time (tCCD) Additive latency delay (AL) Read Begins RAS# - RAS# delay time (>=tRRD) COMMAND Bank B Col. Addr Bank B Row Addr. Bank A Post CAS# Read Bank B Activate Bank B Post CAS# Read Bank precharge time (>=tRP) Bank Active (>=tRAS) RAS# Cycle time (>=tRC) Etron Confidential 35 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 15. Posted CAS# operation: AL=2 Read followed by a write to the same bank -1 0 1 2 Active A-Bank Read A-Bank 3 4 5 6 7 8 9 10 11 12 11 12 CK# CK CMD Write A-Bank AL=2 WL=RL-1=4 CL=3 DQS DQS# >=tRCD RL=AL+CL=5 DQ Din 0 Dout 0 Dout 1 Dout 2 Dout 3 Din 1 Din 2 Din 3 [ AL=2 and CL=3, RL= (AL+CL)=5, WL= (RL-1)=4, BL=4] Figure 16. Posted CAS# operation: AL=0 Read followed by a write to the same bank -1 0 1 2 3 4 5 6 7 8 9 10 CK# CK AL=0 CMD Active A-Bank Write A-Bank Read A-Bank CL=3 DQS DQS# WL=RL-1=2 >=tRCD RL=AL+CL=3 DQ Dout 0 Dout 1 Dout 2 Dout 3 Din 0 Din 1 Din 2 Din 3 [ AL=0 and CL=3, RL= (AL+CL)=3, WL= (RL-1)=2, BL=4] Etron Confidential 36 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 17. Data output (read) timing tCH CK# CK tCL CK DQS# DQS DQS# DQS tRPRE DQ tRPST tDQSQ max Q Q Q Q tDQSQ max tQH tQH Figure 18. Burst read operation: RL=5 (AL=2, CL=3, BL=4) CK# CK CMD T0 T1 Posted CAS# READ A T2 NOP T3 NOP NOP T4 T5 NOP T6 NOP T7 NOP T8 NOP NOP =< tDQSCK DQS DQS# AL=2 CL=3 RL=5 DQs Dout A0 Dout A1 Dout A2 Dout A3 Figure 19. Burst read operation: RL=3 (AL=0, CL=3, BL=8) CK# CK CMD T0 READ A DQS DQS# T1 NOP T2 NOP T3 T4 NOP T5 NOP T6 NOP T7 NOP NOP T8 NOP =< tDQSCK CL=3 RL=3 DQs Etron Confidential Dout A0 Dout A1 37 Dout A2 Dout A3 Dout A4 Dout A5 Dout A6 Rev. 1.0 Dout A7 Jan. /2014 EtronTech EM68C16CWQE Figure 20. Burst read followed by burst write: RL=5, WL= (RL-1) =4, BL=4 T0 CK# CK CMD T1 Post CAS# READ A Tn-1 NOP Tn Tn+1 Post CAS# WRITE A NOP Tn+2 NOP Tn+3 NOP Tn+4 NOP Tn+5 NOP NOP tRTW (Read to Write turn around time) DQS DQS# RL=5 WL = RL-1 = 4 DQs Dout A0 Dout A1 Dout A2 Dout A3 Din A0 Din A1 Din A2 Din A3 NOTE : The minimum time from the burst read command to the burst write command is defined by a read-to-writeturn-around-time, which is 4 clocks in case of BL = 4 operation, 6 clocks in case of BL = 8 operation. Figure 21. Seamless burst read operation: RL=5, AL=2, CL=3, BL=4 T0 CK# CK CMD T1 Post CAS# READ A NOP T2 T3 Post CAS# READ B T4 NOP NOP T5 T6 NOP T7 NOP T8 NOP NOP DQS DQS# AL=2 CL=3 RL=5 DQs Dout A0 Dout A1 Dout A2 Dout A3 Dout B0 Dout B1 Dout B2 NOTE : The seamless burst read operation is supported by enabling a read command at every other clock for BL = 4 operation, and every 4 clock for BL =8 operation. This operation is allowed regardless of same or different banks as long as the banks are activated. Etron Confidential 38 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 22. Read burst interrupt timing: (CL=3, AL=0, RL=3, BL=8) CK# CK CMD Read A NOP NOP Read B NOP NOP NOP NOP NOP NOP DQS DQS# DQs A0 A1 A2 A3 B0 B1 B2 B3 B4 B5 B6 B7 NOTE 1: Read burst interrupt function is only allowed on burst of 8. Burst interrupt of 4 is prohibited. NOTE 2: Read burst of 8 can only be interrupted by another Read command. Read burst interruption by Write command or Precharge command is prohibited. NOTE 3: Read burst interrupt must occur exactly two clocks after previous Read command. Any other Read burst interrupt timings are prohibited. NOTE 4: Read burst interruption is allowed to any bank inside DRAM. NOTE 5: Read burst with Auto Precharge enabled is not allowed to interrupt. NOTE 6: Read burst interruption is allowed by another Read with Auto Precharge command. NOTE 7: All command timings are referenced to burst length set in the mode register. They are not referenced to actual burst. For example, Minimum Read to Precharge timing is AL+BL/2 where BL is the burst length set in the mode register and not the actual burst (which is shorter because of interrupt). Figure 23. Data input (write) timing tDQSH DQS# tDQSL DQS DQS# DQS tWPRE DQ tWPSL VIH(ac) D VIL(ac) tDS DM Etron Confidential VIH(dc) D D VIL(dc) tDH tDS tDH VIH(dc) VIH(ac) DMin D DMin DMin VIL(ac) 39 DMin VIL(dc) Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 24. Burst write operation: RL=5 (AL=2, CL=3), WL=4, BL=4 T0 CK# CK T1 Posted CAS# WRITE A CMD T2 NOP T3 NOP T4 NOP Case 1: with tDQSS (max) DQS DQS# T5 T6 NOP NOP tDQSS tDSS tDQSS T7 NOP tDSS Precharge Completion of the Burst Write WL = RL-1 =4 >=tWR DQs DNA0 Case 2: with tDQSS (min) DQS DQS# NOP Tn tDQSS tDSH DNA1 DNA2 DNA3 tDQSS tDSH >=tWR WL = RL-1 =4 DQs DNA0 DNA1 DNA2 DNA3 Figure 25. Burst write operation: RL=3 (AL=0, CL=3), WL=2, BL=4 CK# CK CMD T0 T1 WRITE A NOP T2 T3 NOP NOP <=tDQSS DQS DQS# Etron Confidential T5 NOP NOP >=tWR DNA0 DNA1 Tm Tm+1 NOP Precharge Tn Bank A Activate Completion of the Burst Write WL = RL-1 =2 DQs T4 >=tRP DNA2 DNA3 40 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 26. Burst write followed by burst read: RL=5 (AL=2, CL=3, WL=4, tWTR=2, BL=4) CK# T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 CK Write to Read = CL-1+BL/2+tWTR CKE DQS DQS# NOP NOP NOP Post CAS# READ A NOP NOP NOP NOP NOP DQS# DQS WL = RL-1 = 4 AL=2 CL=3 RL=5 >=tWTR DQ DNA0 DNA1 DNA2 DNA3 DOUT A0 NOTE : The minimum number of clock from the burst write command to the burst read command is [CL-1 + BL/2 + tWTR]. This tWTR is not a write recovery time (tWR) but the time required to transfer the 4 bit write data from the input buffer into sense amplifiers in the array. tWTR is defined in the timing parameter table of this standard. Figure 27. Seamless burst write operation RL=5, WL=4, BL=4 CK# T0 T1 T2 T3 T4 T5 T6 T7 T8 CK CMD DQS DQS# Post CAS# Write A NOP Post CAS# Write B NOP NOP NOP NOP NOP NOP DQS# DQS WL = RL-1 = 4 DQ DNA0 DNA1 DNA2 DNA3 DNB0 DNB1 DNB2 DNB3 NOTE : The seamless burst write operation is supported by enabling a write command every other clock for BL= 4 operation, every four clocks for BL = 8 operation. This operation is allowed regardless of same or different banks as long as the banks are activated. Etron Confidential 41 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 28. Write burst interrupt timing: (CL=3, AL=0, RL=3, WL=2, BL=8) CK# CK CMD NOP Write A NOP Write B NOP NOP NOP NOP NOP NOP DQS DQS# DQs A0 A1 A2 A3 B0 B1 B2 B3 B4 B5 B6 B7 NOTE 1: Write burst interrupt function is only allowed on burst of 8. Burst interrupt of 4 is prohibited. NOTE 2: Write burst of 8 can only be interrupted by another Write command. Write burst interruption by Read command or Precharge command is prohibited. NOTE 3: Write burst interrupt must occur exactly two clocks after previous Write command. Any other Write burst interrupt timings are prohibited. NOTE 4: Write burst interruption is allowed to any bank inside DRAM. NOTE 5: Write burst with Auto Precharge enabled is not allowed to interrupt. NOTE 6: Write burst interruption is allowed by another Write with Auto Precharge command. NOTE 7: All command timings are referenced to burst length set in the mode register. They are not referenced to actual burst. For example, minimum Write to Precharge timing is WL + BL/2 + tWR where tWR starts with the rising clock after the uninterrupted burst end and not from the end of actual burst end. Etron Confidential 42 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 29. Write data mask Data Mask Timing DQS DQS# DQ DM Data Mask Function, WL=3, AL=0, BL=4 shown VIH(ac)VIH(dc) VIH(ac)VIH(dc) VIL(ac)VIL(dc) VIL(ac)VIL(dc) tDS tDH tDS tDH Case 1: min tDQSS CK# CK tWR COMMAND Write DQS DQS# WL tDQSS DQ DM Case 2: max tDQSS tDQSS DQS DQS# DQ DM Etron Confidential 43 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 30. Burst read operation followed by precharge: (RL=4, AL=1, CL=3, BL=4, tRTP ≦2 clocks) T0 CK# T1 T2 T3 T4 T5 T6 T7 T8 CK Post CAS# Read A CMD NOP NOP NOP Precharge NOP Bank A Active NOP NOP AL+BL'/2 clks DQS DQS# AL=1 CL=3 >=tRP RL=4 DQ DOUTA0 DOUTA1 DOUTA2 DOUTA3 >=tRAS >=tRTP CL=3 Figure 31. Burst read operation followed by precharge: (RL=4, AL=1, CL=3, BL=8, tRTP≦2 clocks) CK# CK CMD DQS DQS# T0 T1 Post CAS# READ A T2 NOP T3 NOP T4 NOP NOP T5 T6 T7 NOP Precharge A T8 NOP NOP AL + BL/2 clks CL = 3 AL = 1 RL= 4 DQ's DOUT A0 DOUT A1 DOUT A2 DOUT A3 DOUT A4 DOUT A5 DOUT A6 DOUT A7 >=tRTP First 4-bit prefetch Etron Confidential Second 4-bit prefetch 44 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 32. Burst read operation followed by precharge: (RL=5, AL=2, CL=3, BL=4, tRTP≦2 clocks) T0 T1 T2 T3 T4 T5 T6 T7 T8 CK# CK CMD Post CAS# READ A NOP NOP NOP NOP Precharge A NOP Bank A Activate NOP AL + BL/2 clks DQS DQS# CL = 3 AL = 2 >=tRP RL= 5 DOUT A0 DQ's >=tRAS DOUT A1 DOUT A2 DOUT A3 CL = 3 >=tRTP Figure 33. Burst read operation followed by precharge: (RL=6, AL=2, CL=4, BL=4, tRTP≦2 clocks) T0 T1 T2 T3 T4 T5 T6 T7 T8 CK# CK CMD Post CAS# READ A NOP NOP NOP Precharge A NOP NOP Bank A Activate NOP AL + BL/2 clks DQS DQS# CL = 4 AL = 2 >=tRP RL= 6 DOUT A0 DQ's >=tRAS DOUT A1 DOUT A2 DOUT A3 CL = 4 >=tRTP Etron Confidential 45 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 34. Burst read operation followed by precharge: (RL=4, AL=0, CL=4, BL=8, tRTP>2 clocks) T0 CK# T1 T2 T3 T4 T5 T6 T7 T8 CK Post CAS# READ A CMD NOP NOP NOP NOP NOP Precharge A NOP Bank A Activate AL + 2 + max( tRTP, 2 tCK)* DQS DQS# CL = 4 AL = 0 >=tRP RL= 4 DQ's DOUT A0 >=tRAS DOUT A1 DOUT A2 DOUT A3 DOUT A4 DOUT A5 DOUT A6 DOUT A7 >=tRTP First 4-bit prefetch Second 4-bit prefetch *: rounded to next integer. Figure 35. Burst write operation followed by precharge: WL= (RL-1) =3 CK# T0 T1 T2 T3 T4 T5 T6 T7 T8 CK CMD Post CAS# Write A NOP NOP NOP NOP NOP NOP NOP Precharge A Completion of the Burst Write DQS DQS# >=tWR WL= 3 DQ's Etron Confidential DNA0 DNA1 46 DNA2 DNA3 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 36. Burst write followed by precharge: WL= (RL-1) =4 T0 CK# T1 T2 T3 T4 T5 T6 T7 T9 CK Post CAS# Write A CMD NOP NOP NOP NOP NOP NOP NOP Precharge A Completion of the Burst Write >=tWR DQS DQS# WL= 4 DQ's DNA0 DNA1 DNA2 DNA3 Figure 37. Burst read operation with auto precharge: (RL=4,AL=1, CL=3, BL=8, tRTP≦2 clocks) T0 CK# CK T1 Post CAS# READ A CMD T2 NOP NOP Autoprecharge DQS DQS# T3 T4 NOP T5 NOP T6 NOP NOP T8 Bank A Activate NOP >= tRP AL + BL/2 clks AL = 1 T7 CL = 3 RL= 4 DQ's >=tRTP DOUT A0 DOUT A1 DOUT A2 DOUT A3 DOUT A4 DOUT A5 DOUT A6 DOUT A7 tRTP First 4-bit prefetch Etron Confidential Second 4-bit prefetch 47 Precharge begins here Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 38. Burst read operation with auto precharge: (RL=4, AL=1, CL=3, BL=4, tRTP>2 clocks) T0 CK# CK T1 Post CAS# READ A CMD T2 NOP NOP T4 NOP NOP T5 T6 NOP NOP T7 Bank A Activate T8 NOP >= AL+tRTP+tRP Autoprecharge DQS DQS# T3 AL= 1 CL= 3 RL= 4 DQ's DoutA0 DoutA1 DoutA2 DoutA3 tRTP tRP First 4-bit prefetch Precharge begins here Figure 39. Burst read operation with auto precharge followed by activation to the same bank (tRC Limit): RL=5(AL=2, CL=3, internal tRCD=3, BL=4, tRTP≦2 clocks) CK# CK T0 T1 T2 T3 T4 T5 T6 T7 T8 A10= 1 CMD DQS DQS# Post CAS# READ A NOP NOP NOP NOP NOP NOP NOP Bank A Activate >=tRAS(min) Auto Precharge Begins AL= 2 CL= 3 >=tRP RL= 5 DQ's DoutA0 DoutA1 DoutA2 DoutA3 CL=3 >= tRC Etron Confidential 48 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 40. Burst read operation with auto precharge followed by an activation to the same bank (tRP Limit): (RL=5 (AL=2, CL=3, internal tRCD=3, BL=4, tRTP≦2 clocks) T0 CK# CK T1 T2 T3 T4 T5 T6 T7 T8 A10= 1 CMD Post CAS# READ A NOP NOP NOP >=tRAS(min) NOP NOP Bank A Activate NOP NOP Auto Precharge Begins DQS DQS# AL= 2 >= tRP CL= 3 RL= 5 DQ's DoutA0 DoutA1 DoutA2 DoutA3 CL=3 >= tRC Figure 41. Burst write with auto-precharge (tRC Limit): WL=2, WR=2, BL=4, tRP=3 CK# CK T0 T1 T2 T3 T4 T5 T6 T7 Tm A10 = 1 CMD Post CAS# WRA Bank A NOP NOP NOP NOP NOP NOP NOP Bank A Active Completion of the Burst Write DQS DQS# Auto Precharge Begins >=WR WL= RL-1=2 DQ's Etron Confidential DNA0 DNA1 >=tRP DNA2 DNA3 >=tRC 49 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 42. Burst write with auto-precharge (WR+tRP): WL=4, WR=2, BL=4, tRP=3 T0 CK# T3 T4 T5 T6 T7 T8 T9 T12 CK A10 = 1 CMD Post CAS# WRA Bank A NOP NOP NOP NOP NOP NOP NOP Bank A Active Completion of the Burst Write Auto Precharge Begins DQS DQS# >=WR >=tRP WL= RL-1=4 DQ's DNA0 DNA1 DNA2 DNA3 >=tRC Figure 43. Refresh command T0 T1 T2 T3 Tm Tn Tn+1 CK# CK HIGH CKE CMD >=tRP Precharge Etron Confidential NOP >=tRFC NOP REF >=tRFC REF 50 NOP Rev. 1.0 ANY Jan. /2014 EtronTech EM68C16CWQE Figure 44. Self refresh operation T0 CK# tCH tCK T1 T2 T3 T4 T5 T6 Tm Tn tCL CK >=tXSNR tRP* >=tXSRD CKE VIH(ac) VIL(ac) tAOFD ODT tIS tIS VIL(ac) tIS tIS tIH tIH tIS VIH(ac) Self VIH(dc) VIL(ac) Refresh VIL(dc) CMD tIH NOP NOP NOP Valid NOTE 1 Device must be in the "All banks idle" state prior to entering Self Refresh mode. NOTE 2 ODT must be turned off tAOFD before entering Self Refresh mode, and can be turned on again when tXSRD timing is satisfied. NOTE 3 tXSRD is applied for Read or a Read with autoprecharge command. tXSNR is applied for any command except a Read or a Read with autoprecharge command. Figure 45. Basic power down entry and exit timing diagram CK CK# tIH CKE Command tIS VALID tIH NOP tIS NOP NOP tCKE min tIS tIH VALID VALID or NOP tXP, tXARD tXARDS Exit Power-Down mode Enter Power-Down mode tIH tCKE(min) Don't Care Figure 46. CKE intensive environment CK# CK tCKE tCKE CKE tCKE tCKE NOTE: DRAM guarantees all AC and DC timing & voltage specifications and proper DLL operation with intensive CKE operation Etron Confidential 51 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 47. CKE intensive environment CK# CK CKE tCKE tCKE tCKE tXP CMD tCKE tXP REF REF tREFI NOTE: The pattern shown above can repeat over a long period of time. With this pattern, DRAM guarantees all AC and DC timing & voltage specifications and DLL operation with temperature and voltage drift Figure 48. Read to power-down entry T0 T1 T2 Tx Tx+1 Tx+2 Tx+3 Tx+4 Tx+5 Tx+6 Tx+7 Tx+8 Tx+9 Tx+8 Tx+9 CK# CK CMD Read operation starts with a read command and RD CKE should be kept HIGH until the end of burst operation BL=4 CKE AL+CL Q DQ Q Q tIS Q DQS DQS# T0 T1 T2 Tx Tx+1 Tx+2 Tx+3 Tx+4 Tx+5 Tx+6 Tx+7 CK# CK CMD RD CKE should be kept HIGH until the end of burst operation BL=8 CKE AL+CL DQ Q Q Q Q Q Q Q Q tIS DQS DQS# Etron Confidential 52 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 49. Read with autoprecharge to power-down entry T0 T1 T2 Tx Tx+1 Tx+2 Tx+3 Tx+4 Tx+5 Tx+6 Tx+7 Tx+8 Tx+9 Tx+8 Tx+9 CK# CK CMD RDA PRE BL=4 CKE should be kept HIGH until the end of burst operation AL+BL/2 with tRTP = 7.5ns & tRAS min satisfied CKE AL+CL Q DQ Q Q tIS Q DQS DQS# T0 T1 T2 Tx Tx+1 Tx+2 Tx+3 Tx+4 Tx+5 Tx+6 Tx+7 CK# CK Start internal precharge CMD RD PRE BL=8 CKE should be kept HIGH until the end of burst operation AL+BL/2 with tRTP = 7.5ns & tRAS min satisfied CKE AL+CL Q DQ Q Q Q Q Q Q tIS Q DQS DQS# Figure 50. Write to power-down entry CK# T0 T1 Tm Tm+1 Tm+2 Tm+3 Tx Tx+1 Tx+2 Ty Ty+1 Ty+2 Ty+3 Tx Tx+1 Tx+2 Tx+3 Tx+4 CK CMD WR BL=4 CKE WL Q DQ Q Q tIS Q tWTR DQS DQS# CK# T0 T1 Tm Tm+1 Tm+2 Tm+3 Tm+4 Tm+5 CK CMD WR BL=8 CKE WL DQ Q Q Q Q Q Q Q tIS Q tWTR DQS DQS# Etron Confidential 53 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 51. Write with autoprecharge to power-down entry T0 T1 Tm Tm+1 Tm+2 Tm+3 Tx Tx+1 Tx+2 Tx+3 Tx+4 Tx+5 Tx+6 Tx+1 Tx+2 Tx+3 Tx+4 CK# CK CMD WRA PRE BL=4 CKE WL Q DQ Q Q tIS Q WR*1 DQS DQS# T0 T1 Tm Tm+1 Tm+2 Tm+3 Tm+4 Tm+5 Tx CK# CK Start internal Precharge CMD WRA PRE BL=8 CKE WL Q DQ Q Q Q Q Q Q tIS Q WR*1 DQS DQS# *1: WR is programmed through MRS Figure 52. Refresh command to power-down entry T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 CK# CK CMD REF CKE can go to LOW one clock after an Auto-refresh command CKE tIS Figure 53. Active command to power-down entry T0 CMD T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 ACT CKE can go to LOW one clock after an Active command CKE tIS Etron Confidential 54 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 54. Precharge/precharge-all command to power-down entry T0 CMD T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 PR or PRA CKE can go to LOW one clock after a Precharge or Precharge all command CKE tIS Figure 55. MRS/EMRS command to power-down entry T0 T1 T2 MRS or EMRS CMD T3 T4 T5 T6 T7 T8 T9 T10 T11 tMRD CKE tIS Figure 56. Asynchronous CKE LOW event Stable clocks tCK CK# CK CKE tDelay CKE asynchronously drops LOW tIS Clocks can be turned off after this point Figure 57. Clock frequency change in precharge power down mode CK# CK T0 CMD T1 T2 NOP NOP T4 Tx Tx+1 Ty Ty+1 Ty+2 Ty+3 NOP NOP Ty+4 DLL RESET Tz NOP Valid Frequency Change Occurs here CKE ODT tIS tXP tRP tAOFD Minimum 2 clocks required before changing frequency Etron Confidential 200 Clocks tIS tIH ODT is off during DLL RESET Stable new clock before power down exit 55 Rev. 1.0 Jan. /2014 EtronTech EM68C16CWQE Figure 58. 84-Ball FBGA Package Outline Drawing Information PIN A 1 IN D EX T op V iew B ottom V iew Side V iew D ET A IL : "A" Symbol A A1 A2 A3 D E D1 E1 F e b D2 Etron Confidential Dimension in inch Dimension in mm Min Nom Max Min Nom Max --0.047 --1.20 0.010 -0.016 0.25 -0.40 0.030 0.031 0.033 0.75 0.80 0.85 0.005 0.006 0.007 0.125 0.155 0.185 0.311 0.315 0.319 7.9 8.0 8.1 0.488 0.492 0.496 12.4 12.5 12.6 -0.252 --6.40 --0.441 --11.2 --0.126 --3.2 --0.031 --0.80 -0.016 0.018 0.020 0.40 0.45 0.50 --0.081 --2.05 56 Rev. 1.0 Jan. /2014