SN842100

S/MOD/SN842x00/E/10/01/2003
page 1 /3 F/GB
SN842x00
25A/280VAC output
3.5-15VDC control
or
15-32VDC control
Relais Statique pour circuit imprimé
Solid State Relay for printed circuit board
fig 1 : Control Ic = f( Uc)
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
3,5 -15V model
12,5-32V model
0
2
4
6
8 10 12 14 16 18 20 22 24 26 28 30 32
Ue(V)
Caractéristiques de commande (à 20°C) / Control characteristics (at 20°C)
DC
SN842100
Symbol Min
Nom Max
Paramètre / Parameter
Uc
3,5
15
Tension de commande / Control voltage
Ic
5
30
Courant de commande / Control current (@ Uc )
Uc off
1
Tension de relachement/Release voltage
Rc
470
Résistance interne / Input internal resistor fig.1
Urv
15
Tension inverse / Reverse voltage
DC
SN842500
Min
Nom Max Unit
12,5
32
V
5
14
mA
1
V
2200
Ω
32
V
Caractéristiques d'entrée-sortie (à 20°C) / Input-output characteristics (at 20°C)
Ui
4000
Isolement entrée-sortie/Input-output isolation @500m
Ui
4000
Isolement sortie-semelle/Output-case isolation @500m
4000
4000
Tension assignée isolement/ Rated impulse voltage
Uimp
4000
V
V
4000
Caractéristiques générales / General characteristics
Conditions
Paramètre / Parameter
Poids/Weight
Plage de température de stockage / Storage temperature range
Plage de température de fonctionnement/Operating temperature range
Proud to serve you
All technical characteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
Symbol
Typ.
11,5
-40 / +100
-40 / +100
Unit
g
°C
°C
celduc
r
e
l
a
i
®
s
S/MOD/SN842x00/E/10/01/2003
Caractéristiques de sortie(à 20°C) / Output characteristics (at 20°C)
Paramètre / Parameter
Tension de charge / Load voltage
Plage tension de fonctionnement / Operating range
Tension crête (écrêteur de tension) / Peak voltage (clamping voltage)
Niveau de synchonisation / Synchronizing level
Tension d'amorçage / Latching voltage
Courant nominal AC-51/ AC-51 nominal current
Courant nominal AC-53/ AC-53 nominal current
Courant de surcharge non répétitif /Non repetitive overload current
page 2 / 3 F/GB
Conditions
Ie nom
( see Fig. 2 )
Symbol
Ue
Ue min-max
Up
Usync
Ua
Ie AC-51
Typ.
230
24-280
600
25
10
25
Unit
V rms
V rms
V
V
V
A rms
tp=16,3ms (Fig. 3)
Itsm
250
1,08 +
A
@ Ie nom
Vd
V
@Ue, 60Hz
Ilk
Ie min
ton max
toff max
f
dv/dt
I2t
0,016 x I
0,7 (*)
<1
50
8,3
8,3
47-440
500
260
Chute tension directe crête/ On state voltage drop
Thermal resistance between junction to case :Rthj/c
Courant de fuite état bloqué/ Off state leakage current
Courant de charge minimum / Minimum load current
Temps de fermeture/ Turn on time
Temps d'ouverture/ Turn off time
Plage de fréquence / Operating frequency range
dv/dt état bloqué / Off state dv/dt
I2t (<10ms)
Uc nom DC ,f=60Hz
Uc nom DC ,f=60Hz
60hz
K/W
mA
mA
ms
ms
Hz
V/µs
A2s
(*) This product is built with a thermal pad, you have to take the thermal resitance of the contact (about 0,2K/W) into account.
Proud to serve you
All technical characteristics are subject to change without previous notice.
Caractéristiques sujettes à modifications sans préavis.
celduc
r
e
l
a
i
®
s
S/MOD/SN842x00/E/10/01/2003
page 3 / 3 F/GB
Voltage protection :
An external voltage protection by VDR is advised in case of overvoltages on the mains.
Ph
The input of these relays is built with a
current regulator . In case of overvoltages ,
the input can be damaged.
+
So don't put a coil of an electromechanical
relay in parallel with the input without
voltage protection.
Ic
AC
Uc
-
AC
Load
celduc
®
www.celduc.com
r e l a i s
5, Rue Ampère BP30004 42290 SORBIERS - FRANCE
E-mail : [email protected]
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19