S/MOD/SN842x00/E/10/01/2003 page 1 /3 F/GB SN842x00 25A/280VAC output 3.5-15VDC control or 15-32VDC control Relais Statique pour circuit imprimé Solid State Relay for printed circuit board fig 1 : Control Ic = f( Uc) 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 3,5 -15V model 12,5-32V model 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 Ue(V) Caractéristiques de commande (à 20°C) / Control characteristics (at 20°C) DC SN842100 Symbol Min Nom Max Paramètre / Parameter Uc 3,5 15 Tension de commande / Control voltage Ic 5 30 Courant de commande / Control current (@ Uc ) Uc off 1 Tension de relachement/Release voltage Rc 470 Résistance interne / Input internal resistor fig.1 Urv 15 Tension inverse / Reverse voltage DC SN842500 Min Nom Max Unit 12,5 32 V 5 14 mA 1 V 2200 Ω 32 V Caractéristiques d'entrée-sortie (à 20°C) / Input-output characteristics (at 20°C) Ui 4000 Isolement entrée-sortie/Input-output isolation @500m Ui 4000 Isolement sortie-semelle/Output-case isolation @500m 4000 4000 Tension assignée isolement/ Rated impulse voltage Uimp 4000 V V 4000 Caractéristiques générales / General characteristics Conditions Paramètre / Parameter Poids/Weight Plage de température de stockage / Storage temperature range Plage de température de fonctionnement/Operating temperature range Proud to serve you All technical characteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis. Symbol Typ. 11,5 -40 / +100 -40 / +100 Unit g °C °C celduc r e l a i ® s S/MOD/SN842x00/E/10/01/2003 Caractéristiques de sortie(à 20°C) / Output characteristics (at 20°C) Paramètre / Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crête (écrêteur de tension) / Peak voltage (clamping voltage) Niveau de synchonisation / Synchronizing level Tension d'amorçage / Latching voltage Courant nominal AC-51/ AC-51 nominal current Courant nominal AC-53/ AC-53 nominal current Courant de surcharge non répétitif /Non repetitive overload current page 2 / 3 F/GB Conditions Ie nom ( see Fig. 2 ) Symbol Ue Ue min-max Up Usync Ua Ie AC-51 Typ. 230 24-280 600 25 10 25 Unit V rms V rms V V V A rms tp=16,3ms (Fig. 3) Itsm 250 1,08 + A @ Ie nom Vd V @Ue, 60Hz Ilk Ie min ton max toff max f dv/dt I2t 0,016 x I 0,7 (*) <1 50 8,3 8,3 47-440 500 260 Chute tension directe crête/ On state voltage drop Thermal resistance between junction to case :Rthj/c Courant de fuite état bloqué/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de fréquence / Operating frequency range dv/dt état bloqué / Off state dv/dt I2t (<10ms) Uc nom DC ,f=60Hz Uc nom DC ,f=60Hz 60hz K/W mA mA ms ms Hz V/µs A2s (*) This product is built with a thermal pad, you have to take the thermal resitance of the contact (about 0,2K/W) into account. Proud to serve you All technical characteristics are subject to change without previous notice. Caractéristiques sujettes à modifications sans préavis. celduc r e l a i ® s S/MOD/SN842x00/E/10/01/2003 page 3 / 3 F/GB Voltage protection : An external voltage protection by VDR is advised in case of overvoltages on the mains. Ph The input of these relays is built with a current regulator . In case of overvoltages , the input can be damaged. + So don't put a coil of an electromechanical relay in parallel with the input without voltage protection. Ic AC Uc - AC Load celduc ® www.celduc.com r e l a i s 5, Rue Ampère BP30004 42290 SORBIERS - FRANCE E-mail : [email protected] Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19