MCD Differential Capsule Pressure Gauge Main Features Low pressure measurement For non-corrosive gasses Accuracy +/- 2% F.S. Static pressure max. 250 mbar Option: case material 1.4404 (316L) for aggressive atmosphere Applications Laboratory & Medical Oil & Gas / Chemical Machinery Technical Data Nominal size 150 mm Dial Aluminium, white Measurement range 0…10 mbar to 0…250 mbar Pointer Aluminium, black Static pressure Temperature Ambient : -20 ... +60°C Medium: -20 ... +60°C Storage: -40 ... +70°C Manifolds 3-way manifolds are recommended to ensure to apply the pressure simultaneously on both sides and avoid single-sided overload. Working principle The HP is applied inside the capsule and the LP outside the capsule (in the case). The deflection of the capsule results from the difference between the pressure inside (HP) and outside (LP). Zero adjustment +/- 10 % F.S. Adjustment screw accessible on the front side after removing of the bezel ring and window. Max. 250 mbar Allowed single-sided HP side: max. 250 mbar overpressure LP side: max. 130 % F.S. Safety valve Viton® - FKM Integrated on the HP side to protect the capsule Accuracy ± 2% F.S. Protection rating IP 66 (EN 60529) Capsule Stainless steel 1.4404 (AISI 316L) Case Stainless steel 1.4301 (AISI 304) Bezel ring Stainless steel 1.4301 (AISI 304) Movement Brass Window Instrument glass Window gasket Elastomer Code 0651 Window laminated safety glass Code 0751 Window Plexiglas Code 0752 Oxygen application Code 0765 2013-11-04 Stainless steel movement Design and specifications subject to change without notice Options www.baumer.com Data sheet A24.20 Page 1 / 3 MCD Differential Capsule Pressure Gauge Dimensions - Types of mounting (3x) Ø 5,5/120° Ø 168 R P B A HP 22 B Ø 180 A K 22 E (2x) G 1/2 45° Setting BP HP BP 45° F (2x) G 1/2 Setting Type A 45° 45° Type D mm A B E F K P R Weight NS 150 150.2 90 25.4 23 56.4 142 54.5 0.9 Pressure ranges N03 mbar 0 ... 10 Code D03 kPa 0 ... Code 1 R03 mmH20 0 ... 100 N04 0 ... 16 D04 0 ... 1.6 R04 0 ... 160 N05 0 ... 25 D05 0 ... 2.5 R05 0 ... 250 N06 0 ... 40 D06 0 ... 4 R06 0 ... 400 N07 0 ... 60 D07 0 ... 6 R07 0 ... 600 0 ... 100 D08 0 ... 10 R08 0 ... 1000 0 ... 160 D09 0 ... 16 R09 0 ... 1600 N10 0 ... 250 D10 0 ... 25 R10 0 ... 2500 2013-11-04 N08 N09 Design and specifications subject to change without notice Code www.baumer.com Data sheet A24.20 Page 2 / 3 MCD Differential Capsule Pressure Gauge Ordering details MCD 7 Model Differential capsule pressure gauge Nominal size 150 mm . xxx / MCD 7 Type of mounting Stainless steel case and bezel ring 1.4301 (AISI 304) Bottom connection, 3 back lugs fixing Bottom connection Stainless steel case and bezel ring 1.4404 (AISI 316L) Bottom connection, 3 back lugs fixing Bottom connection Process connection G 1/2 1/2 NPT Liquid filling Dry – A D 1 4 3 6 0 Measurement unit mbar kPa mmH20 Options to be added behind the / (see example below) (4) 0 – . N xx D xx R xx Available standard pressures ranges, see tables on page 2. For ranges not listed, please contact Baumer. ( Standard version) / Ordering example with options MCD 7 – D 3 0 . N06 / 0752 _ 0765 Industrial capsule differential pressure gauge Nominal size 150 mm Bottom connection, case material 1.4301 Process connection G1/2 No liquid filling Scale mbar : 0 ... 40 mbar Option : Plexiglas window 2013-11-04 Design and specifications subject to change without notice Option : Oxygen application www.baumer.com Data sheet A24.20 Page 3 / 3