Double Digits LED Numeric Display LBP-602 A / K2 Series LBP-602 A / K2 series are the numberical display units featuring ROHM’s in-house 4-element(AlGaInP) high-brightness LED dies.Their luminous intensity is top class in the industry while degradation is considerably slow, which helps to keep illumination vividness almost unchanged and the image of sets high over a long period of time. Dimensions (Unit : mm) 25.0±0.1 12.5 0.25 Features 1) 14.3mm for letter height, two-lines LED numerical displays. 2) About 10 times more luminous intensity than the conventional products by use of 4-element LED dies. (in case of orange color) 3) The same luminous intensity as the conventional products at their 1/10 of current, which contributes lots to energy-saving of sets. 4)Light-leakage from segments probable with the small display packages is very rare. 5)Both anode common type and cathode common type are available in lineup for each color. (15.24) 1.3 14.3 19.0±0.1 10° 2−φ1.5 3.5Min. 8.0 1.3 8.0 0.5 (2.54) (20.32) Tolerance are ±0.3 unless otherwise noted : Selection guide Emitting color Common Anode Cathode Red Orange Yellow Green LBP-602VA2 LBP-602VK2 LBP-602DA2 LBP-602DK2 LBP-602YA2 LBP-602YK2 LBP-602MA2 LBP-602MK2 Pin assignments 18 17 16 15 14 13 12 11 10 + + + + + + + a1 + + a2 f1 b1 f2 b2 g1 g2 e1 c1 e2 c2 d1 d2 Digit 1 D.P1 Digit 2 D.P2 + + + + + + + + + Pin No. 1 2 3 4 5 6 7 8 9 Inner circuit (anode common) a1 b1 c1 d1 e1 f1 g1 D.P1 16 15 3 2 1 18 17 4 Function Pin No. Function 1 2 3 4 5 6 7 8 9 Segment "e1" Segment "d1" Segment "c1" D.P1 Segment "e2" Segment "d2" Segment "g2" Segment "c2" D.P2 10 11 12 13 14 15 16 17 18 Segment "b2" Segment "a2" Segment "f2" Digit 2 Common Digit 1 Common Segment "b1" Segment "a1" Segment "g1" Segment "f1" (cathode common) a2 b2 c2 d2 e2 f2 g2 D.P2 11 10 8 6 5 12 7 9 14 Dig.1 Pin No. a1 b1 c1 d1 e1 f1 g1 D.P1 16 15 3 2 1 18 17 4 13 COM Dig.2 www.rohm.com c 2010 ROHM Co., Ltd. All rights reserved. ○ a2 b2 c2 d2 e2 f2 g2 D.P2 11 10 8 6 5 12 7 9 14 COM Dig.1 1/3 13 COM Dig.2 COM 2010.12 - Rev.A LBP-602 A / K2 Series Data Sheet Absolute maximum ratings (Ta=25C) Red Symbol Parameter PD PD / seg IF IFP VR Topr Tstg Power dissipation Power dissipation Forward current Peak forward current Reverse voltage Operating temperature Storage temperature Orange Green Yellow Unit LBP-602VA2 / VK2 LBP-602DA2 /DK2 LB-602YA2 / YK2 LBP-602MA2 / MK2 896 896 896 896 56 56 56 56 20 20 20 20 60 ∗ 60 ∗ 60 ∗ 60 ∗ 5 5 5 5 −25 to +75 −30 to +85 mW mW mA mA V ˚C ˚C ∗ Pulse width 1ms Duty 1 / 5 Electrical characteristics (Ta=25C) Symbol Conditions Parameter Forward voltage Reverse current Peak wavelength Spectral line half width IF=10mA VR=3V IF=10mA IF=10mA VF IR λP Δλ Red Max. 2.8 100 − − Typ. 1.9 − 650 20 Orange Typ. 1.9 − 605 ∗ 20 ∗ Max. 2.8 100 − − Yellow Typ. 1.9 − 590 20 Max. 2.8 100 − − Green Typ. 1.9 − 572 20 Max. 2.8 100 − − Unit V μA nm nm The products are not radiations resistant. Luminous intensity Color λP (nm) Red 650 Orange 605 Yellow 590 Green 572 Type LBP-602VA2 LBP-602VK2 LBP-602DA2 LBP-602DK2 LBP-602YA2 LBP-602YK2 LBP-602MA2 LBP-602MK2 Min. Typ. Unit 14 36 mcd 56 250 mcd 90 450 mcd 36 100 mcd A condition of measurement is IF=10mA. www.rohm.com c 2010 ROHM Co., Ltd. All rights reserved. ○ 2/3 2010.12 - Rev.A LBP-602 A / K2 Series Data Sheet Electrical and optical characteristic curve 100 10 Relative Luminous Intensity 10 1 0.1 1 0.1 0.01 2.4 1 Fig.1 Forward Current - Forward Voltage 1.2 1 0.8 0.6 0.4 20 40 60 80 Case Temperature : Tc(℃) Fig.3 Relative Luminous Intensity Case Temperature(℃) 10 Ta=25 ℃ 50kHz IF=10mA 1.4 0 100 Fig.2 Relative Luminous Intensity Forward Current Ratio of Maximum Tolerance Peak Current IF PEAK MAX. IF MAX. to Maximum Tolerance DC Cerrent Relative Luminous Intensity 1.6 -20 10 Forward Current(mA) Forward Voltage : VF(V) 100Hz 2.2 200Hz 2 1kHz 1.8 500Hz 1.6 5kHz 1.4 2kHz 1.2 10kHz 1 20kHz Forward Current : IF(mA) Ta=25℃ 1 1 10 100 1000 10000 Pulse Duration : Tw (μs) Fig.4 Ratio of Maximum Tolerable Peak CurrentPulse Duration 120 Forward Current(%) 100 80 60 40 20 0 -25 -15 -5 5 15 25 35 45 55 65 75 85 Ambient Temperature(℃) Fig.5 Derating www.rohm.com c 2010 ROHM Co., Ltd. All rights reserved. ○ 3/3 2010.12 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2010 ROHM Co., Ltd. All rights reserved. R1010A