FLASH AS8F128K32 128K x 32 FLASH PIN ASSIGNMENT (Top View) AVAILABLE AS MILITARY SPECIFICATIONS 68 Lead CQFP (Q & Q1) • • NC A0 A1 A2 A3 A4 A5 CS3\ GND CS4\ WE1\ A6 A7 A8 A9 A10 Vcc FLASH MEMORY ARRAY SMD 5962-94716 MIL-STD-883 I/O 0 I/O 1 I/O 2 I/O 3 I/O 4 I/O 5 I/O 6 I/O 7 GND I/O 8 I/O 9 I/O 10 I/O 11 I/O 12 I/O 13 I/O 14 I/O 15 FEATURES Fast Access Times: 60, 70, 90, 120 and 150ns Operation with single 5V (±10%) Compatible with JEDEC EEPROM command set Any Combination of Sectors can be Erased Supports Full Chip Erase Embedded Erase and Program Algorithms TTL Compatible Inputs and CMOS Outputs Hardware Data Protection Data\ Polling and Toggle Bits Low Power consumption Individual Byte Read/ Write Control Minimum 1,000,000 Program/Erase Cycles per sector guaranteed OPTIONS • • erase and programming circuitry. Write cycles also internally latch addresses and data needed for the programming and erase operations. Reading data out of the device is similar to reading from other Flash or EPROM devices. Device programming occurs by executing the program command sequence. This invokes the Embedded Program algorithm—an internal algorithm that automatically times the program pulse widths and verifies proper cell margin. Device erasure occurs by executing the erase command sequence. This invokes the Embedded Erase algorithm—an internal algorithm that automatically preprograms the array (if it is not already programmed) before executing the erase operation. During erase, the device automatically times the erase pulse widths and verifies proper cell margin. The host system can detect whether a program or erase operation is complete by reading the I/O7 (Data\ Polling) and I/O6 (toggle) status bits. After a program or erase cycle has been completed, the device is ready to read array data or accept another command. The sector erase architecture allows memory sectors to be erased and reprogrammed without affecting the data contents of other sectors. The device is erased when shipped from the factory. The hardware data protection measures include a low VCC detector automatically inhibits write operations during power transitions. The hardware sector protection feature disables both program and erase operations in any combination of the sectors of memory, and is implemented using standard EPROM programmers. The system can place the device into the standby mode. Power consumption is greatly reduced in this mode. The device electrically erases all bits within a sector simultaneously via Fowler-Nordheim tunneling. The bytes are programmed one byte at a time using the EPROM programming mechanism of hot electron injection. MARKINGS Timing 60ns 70ns 90ns 120ns 150ns Package Ceramic Quad Flat pack Ceramic Quad Flat pack Vcc A11 A12 A13 A14 A15 A16 CS1\ OE CS2\ NC WE2\ WE3\ WE4\ NC NC NC • • • • • • • • • • • • -60 -70 -90 -120 -150 Q Q1 No. 703 GENERAL DESCRIPTION The AS8F128K32 is a 4 Megabit CMOS FLASH Memory Module organized as 128K x 32 bits. The AS8F128K32 achieves high speed access (60 to 150 ns), low power consumption and high reliability by employing advanced CMOS memory technology. The device is designed to be programmed in-system with the standard system 5.0V VCC supply. A 12.0V VPP is not required for program or erase operation. The device can also be programmed or erased in standard EPROM programmers. To eliminate bus contention the device has seperate chip enbaled (CEx\), write enable (WEx\) and output enable (OE) controls. The device requires only a single 5.0 volt power supply for both read and write functions. Internally generated and regulated voltages are provided for the program and erase operations. The device is entirely command set compatible with the JEDEC single-power-supply Flash standard. Commands are written to the command register using standard microprocessor write timings. Register contents serve as input to an internal state machine that controls the AS8F128K32 Rev. 2.8 01/10 I/O 16 I/O 17 I/O 18 I/O 19 I/O 20 I/O 21 I/O 22 I/O 23 GND I/O 24 I/O 25 I/O 26 I/O 27 I/O 28 I/O 29 I/O 30 I/O 31 For more products and information please visit our web site at www.micross.com Micross Components reserves the right to change products or specifications without notice. 1 FLASH AS8F128K32 FUNCTIONAL BLOCK DIAGRAM PIN CONFIGURATION PIN A0 - A16 I/O0 - I/O31 CEx\ OE\ WEx\ LOGIC SYMBOL DESCRIPTION Addresses Input/Output Chip Enable Output Enable Write Enable VCC 5.0V Power Supply GND Device Ground xNC = 1, 2, 3 or 4 No Connect AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 2 FLASH AS8F128K32 DEVICE BUS OPERATIONS the command register contents are altered. See “Reading Array Data” for more information. Refer to the AC Read Operations table for timing specifications and to the Read Operations Timings diagram for the timing waveforms. ICC1 in the DC Characteristics table represents the active current specification for reading array data. NOTE: All device/algorithm descriptions contained in this data sheet reference each individual die. This section describes the requirements and use of the device bus operations, which are initiated through the internal command register. The command register itself does not occupy any addressable memory location. The register is composed of latches that store the commands, along with the address and data information needed to execute the command. The contents of the register serve as inputs to the internal state machine. The state machine outputs dictate the function of the device. The appropriate device bus operations table lists the inputs and control levels required, and the resulting output. The following subsections describe each of these operations in further detail. Writing Commands/Command Sequences To write a command or command sequence (which includes programming data to the device and erasing sectors of memory), the system must drive WEx\ and CEx\ to VIL, and OE\ to VIH. An erase operation can erase one sector, multiple sectors, or the entire device. The Sector Address Tables indicate the address space that each sector occupies. A “sector address” consists of the address bits required to uniquely select a sector. See the “Command Definitions” section for details on erasing a sector or the entire chip. After the system writes the autoselect command sequence, the device enters the autoselect mode. The system can then read autoselect codes from the internal register (which is separate from the memory array) on I/O31–I/O0. Standard read cycle timings apply in this mode. Refer to the “Autoselect Mode” and “Autoselect Command Sequence” sections for more information. ICC2 in the DC Characteristics table represents the active current specification for the write mode. The “AC Characteristics” section contains timing specification tables Requirements for Reading Array Data To read array data from the outputs, the system must drive the CEx\ and OE\ pins to VIL. CEx\ is the power control and selects the device. OE\ is the output control and gates array data to the output pins. WEx\ should remain at VIH. The internal state machine is set for reading array data upon device power-up. This ensures that no spurious alteration of the memory content occurs during the power transition. No command is necessary in this mode to obtain array data. Standard microprocessor read cycles that assert valid addresses on the device address inputs produce valid data on the device data outputs. The device remains enabled for read access until TABLE 1: Device Bus Operations1 CEx\ OE\ WEx\ ADRESSES (A16:A0) I/O0 - I/O31 Read L L H AIN DOUT Write L H L AIN DIN VCC ± 0.5V X X X High-Z Output Disable L H H X High-Z Hardware Reset X X X X High-Z Temporary Sector Unprotect X X X AIN DIN OPERATION Standby LEGEND: L = Logic Low = VIL, H = Logic High = VIH, VID = 12.0 ± 0.5 V, X = Don’t Care, AIN = Addresses In, DIN = Data In, DOUT = Data Out NOTES: 1. The sector protect and sector unprotect functions must be implemented via programming equipment. See the “Sector Protection/Unprotection” section. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 3 FLASH AS8F128K32 Program and Erase Operation Status Autoselect Mode During an erase or program operation, the system may check the status of the operation by reading the status bits on I/ O31–I/O0. Standard read cycle timings and ICC read specifications apply. Refer to “Write Operation Status” for more information, and to each AC Characteristics section in the appropriate data sheet for timing diagrams. The autoselect mode provides manufacturer and device identification, and sector protection verification, through identifier codes output on I/O31–I/O0. This mode is primarily intended for programming equipment to automatically match a device to be programmed with its corresponding programming algorithm. However, the autoselect codes can also be accessed in-system through the command register. When using programming equipment, the autoselect mode requires VID (11.5 V to 12.5 V) on address pin A9. Address pins A6, A1, and A0 must be as shown in Autoselect Codes (High Voltage Method) table. In addition, when verifying sector protection, the sector address must appear on the appropriate highest order address bits. Refer to the corresponding Sector Address Tables. The Command Definitions table shows the remaining address bits that are don’t care. When all necessary bits have been set as required, the programming equipment may then read the corresponding identifier code on I/O31– I/ O0. To access the autoselect codes in-system, the host system can issue the autoselect command via the command register, as shown in the Command Definitions table. This method does not require VID. See “Command Definitions” for details on using the autoselect mode. Standby Mode When the system is not reading or writing to the device, it can place the device in the standby mode. In this mode, current consumption is greatly reduced, and the outputs are placed in the high impedance state, independent of the OE\ input. The device enters the CMOS standby mode when the CEx\ pin is held at VCC ± 0.5 V. (Note that this is a more restricted voltage range than VIH.) The device enters the TTL standby mode when CEx\ is held at VIH. The device requires the standard access time (tCE) before it is ready to read data. If the device is deselected during erasure or programming, the device draws active current until the operation is completed. ICC3 in the DC Characteristics tables represents the standby current specification. Output Disable Mode When the OE\ input is at VIH, output from the device is disabled. The output pins are placed in the high impedance state. TABLE 2: Sector Addresses Table (Each Byte) SECTOR SA0 SA1 SA2 SA3 SA4 SA5 SA6 SA7 AS8F128K32 Rev. 2.8 01/10 A16 0 0 0 0 1 1 1 1 A15 0 0 1 1 0 0 1 1 A14 0 1 0 1 0 1 0 1 ADDRESS RANGE 00000h - 03FFFh 04000h - 07FFFh 08000h - 0BFFFh 0C000h - 0FFFFh 10000h - 13FFFh 14000h - 17FFFh 18000h - 1BFFFh 1C000h - 1FFFFh Micross Components reserves the right to change products or specifications without notice. 4 FLASH AS8F128K32 Sector Protection/Unprotection Low VCC Write Inhibit The hardware sector protection feature disables both program and erase operations in any sector. The hardware sector unprotection feature re-enables both program and erase operations in previously protected sectors. Sector protection/unprotection must be implemented using programming equipment. The procedure requires a high voltage (VID) on address pin A9 and the control pins. The device is shipped with all sectors unprotected. It is possible to determine whether a sector is protected or unprotected. See “Autoselect Mode” for details. When VCC is less than VLKO, the device does not accept any write cycles. This protects data during VCC power-up and power-down. The command register and all internal program/ erase circuits are disabled, and the device resets. Subsequent writes are ignored until VCC is greater than VLKO. The system must provide the proper signals to the control pins to prevent unintentional writes when VCC is greater than VLKO. Write Pulse “Glitch” Protection Noise pulses of less than 5 ns (typical) on OE\, CEx\ or WEx\ do not initiate a write cycle. Hardware Data Protection The command sequence requirement of unlock cycles for programming or erasing provides data protection against inadvertent writes (refer to the Command Definitions table). In addition, the following hardware data protection measures prevent accidental erasure or programming, which might otherwise be caused by spurious system level signals during VCC power-up and power-down transitions, or from system noise. Logical Inhibit Write cycles are inhibited by holding any one of OE\ = VIL, CEx\ = VIH or WEx\ = VIH. To initiate a write cycle, CEx\ and WEx\ must be a logical zero while OE\ is a logical one. Power-Up Write Inhibit If WEx\ = CEx\ = VIL and OE\ = VIH during power up, the device does not accept commands on the rising edge of WEx\. The internal state machine is automatical ly reset to reading array data on power-up. TABLE 3: Autoselect Codes (High Voltage Method) CEx\ OE\ WEx\ A16 to A14 Manufacturer ID: AMD L L H X X VID X L X L L I/O0 to I/O7 I/O8 to I/O15 I/O16 to I/O23 I/O24 to I/O31 01h Device ID: AM29F010B L L H X X VID X L X L H 20h L L H SA X VID X L X H L DESCRIPTION A13 to A10 A9 A8 to A6 A7 A5 to A2 A1 A0 01h (protected) Sector Protection Verification 00h (unprotected) LEGEND: L = Logic Low = VIL, H = Logic High = VIH, SA = Sector Address, X = Don’t care. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 5 FLASH AS8F128K32 COMMAND DEFINITIONS Autoselect Command Sequence Writing specific address and data commands or sequences into the command register initiates device operations. The Command Definitions table defines the valid register command sequences. Writing incorrect address and data values or writing them in the improper sequence resets the device to reading array data. All addresses are latched on the falling edge of WEx\ or CEx\, whichever happens later. All data is latched on the rising edge of WEx\ or CEx\, whichever happens first. Refer to the appropriate timing diagrams in the “AC Characteristics” section. The autoselect command sequence allows the host system to access the manufacturer and devices codes, and determine whether or not a sector is protected. The Command Definitions table shows the address and data requirements. This method is an alternative to that shown in the Autoselect Codes (High Voltage Method) table, which is intended for PROM programmers and requires VID on address bit A9. The autoselect command sequence is initiated by writing two unlock cycles, followed by the autoselect command. The device then enters the autoselect mode, and the system may read at any address any number of times, without initiating another command sequence. A read cycle at address XX00h or retrieves the manufacturer code. A read cycle at address XX01h returns the device code. A read cycle containing a sector address (SA) and the address 02h in returns 01h if that sector is protected, or 00h if it is unprotected. Refer to the Sector Address tables for valid sector addresses. The system must write the reset command to exit the autoselect mode and return to reading array data. Reading Array Data The device is automatically set to reading array data after device power-up. No commands are required to retrieve data. The device is also ready to read array data after completing an Embedded Program or Embedded Erase algorithm. The system must issue the reset command to re-enable the device for reading array data if I/O5* goes high, or while in the autoselect mode. See the “Reset Command” section, next. See also “Requirements for Reading Array Data” in the “Device Bus Operations” section for more information. The Read Operations table provides the read parameters, and Read Operation Timings diagram shows the timing diagram. Byte Program Command Sequence Programming is a four-bus-cycle operation. The program command sequence is initiated by writing two unlock write cycles, followed by the program set-up command. The program address and data are written next, which in turn initiate the Embedded Program algorithm. The system is not required to provide further controls or timings. The device automatically provides internally generated program pulses and verify the programmed cell margin. The Command Definitions take shows the address and data requirements for the byte program command sequence. When the Embedded Program algorithm is complete, the device then returns to reading array data and addresses are no longer latched. The system can determine the status of the program operation by using I/O7or I/O6. See “Write Operation Status” for information on these status bits. Any commands written to the device during the Embedded Program Algorithm are ignored. Programming is allowed in any sequence and across sector boundaries. A bit cannot be programmed from a “0” back to a “1”. Attempting to do so may halt the operation and set I/O5* to “1”, or cause the Data\ Polling algorithm to indicate the operation was successful. However, a succeeding read will show that the data is still “0”. Only erase operations can convert a “0” to a “1”. Reset Command Writing the reset command to the device resets the device to reading array data. Address bits are don’t care for this command. The reset command may be written between the sequence cycles in an erase command sequence before erasing begins. This resets the device to reading array data. Once erasure begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in a program command sequence before programming begins. This resets the device to reading array data. Once programming begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in an autoselect command sequence. Once in the autoselect mode, the reset command must be written to return to reading array data. If I/O5* goes high during a program or erase operation, writing the reset command returns the device to reading array data. *NOTE: applies to every 8th byte (i.e. I/O5, I/O13, I/O21, I/O29) AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 6 FLASH AS8F128K32 additional sector erase commands can be assumed to be less than 50 ms, the system need not monitor I/O3*. Any command during the time-out period resets the device to reading array data. The system must rewrite the command sequence and any additional sector addresses and commands. The system can monitor I/O3* to determine if the sector erase timer has timed out. (See the “I/O3*: Sector Erase Timer” section.) The time-out begins from the rising edge of the final WE# pulse in the command sequence. Once the sector erase operation has begun, all other commands are ignored. When the Embedded Erase algorithm is complete, the device returns to reading array data and addresses are no longer latched. The system can determine the status of the erase operation by using I/O7 or I/O6. Refer to “Write Operation Status” for information on these status bits. Figure 2 illustrates the algorithm for the erase operation. Refer to the Erase/Program Operations tables in the “AC Characteristics” section for parameters, and to the Sector Erase Operations Timing diagram for timing waveforms. Chip Erase Command Sequence Chip erase is a six-bus-cycle operation. The chip erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the chip erase command, which in turn invokes the Embedded Erase algorithm. The device does not require the system to preprogram prior to erase. The Embedded Erase algorithm automatically preprograms and verifies the entire memory for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. The Command Definitions table shows the address and data requirements for the chip erase command sequence. Any commands written to the chip during the Embedded Erase algorithm are ignored. The system can determine the status of the erase operation by using I/O7 or I/O6. See “Write Operation Status” for information on these status bits. When the Embedded Erase algorithm is complete, the device returns to reading array data and addresses are no longer latched. Figure 2 illustrates the algorithm for the erase operation. See the Erase/Program Operations tables in “AC Characteristics” for parameters, and to the Chip/Sector Erase Operation Timings for timing waveforms. FIGURE 1: Program Operation Sector Erase Command Sequence Sector erase is a six bus cycle operation. The sector erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the address of the sector to be erased, and the sector erase command. The Command Definitions table shows the address and data requirements for the sector erase command sequence. The device does not require the system to preprogram the memory prior to erase. The Embedded Erase algorithm automatically programs and verifies the sector for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. After the command sequence is written, a sector erase time-out of 50 ms begins. During the time-out period, additional sector addresses and sector erase commands may be written. Loading the sector erase buffer may be done in any sequence, and the number of sectors may be from one sector to all sectors. The time between these additional cycles must be less than 50 ms, otherwise the last address and command might not be accepted, and erasure may begin. It is recommended that processor interrupts be disabled during this time to ensure all commands are accepted. The interrupts can be re-enabled after the last Sector Erase command is written. If the time between NOTE: See the appropriate Command Definitions table for program command sequence. *NOTE: applies to every 8th byte (i.e. I/O3, I/O11, I/O19, I/O27) AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 7 FLASH AS8F128K32 COMMAND SEQUENCE CYCLES TABLE 4: Command Definitions (Applies to each device8) 1 4 Read Reset 5 6 Autoselect Manufacturer ID Device ID 7 Sector Protect Verify Program Chip Erase Sector Erase 2,3 FIRST SECOND 8 Addr Data Addr Data8 1 RA RD 3 4 4 555 555 555 555 AA AA AA 4 4 6 6 555 555 555 555 AA AA AA AA 2AA 2AA 2AA 2AA 55 55 55 55 2AA 2AA 2AA 2AA 55 55 55 BUS CYCLES FIFTH SIXTH THIRD FOURTH 8 8 8 Addr Data Addr Data Addr Data Addr Data8 555 555 555 555 555 555 555 555 F0 90 90 90 A0 80 80 XX00 XX01 (SA) X02 PA 555 555 1 20 00 01 PD AA AA 2AA 2AA 55 55 555 SA 10 30 NOTES: 1. See Table 1 for description of bus operations. 2. All values are in hexadecimal. 3. Except when reading array or autoselect data, all command bus cycles are write operations. 4. No unlock or command cycles required when reading array data. 5. The Reset command is required to return to reading array data when device is in the autoselect mode, or if I/O5 goes high (while the device is providing status data). 6. The fourth cycle of the autoselect command sequence is a read operation. 7. The data is 00h for an unprotected sector and 01h for a protected sector. See “Autoselect Command Sequence” for more information. 8. Data shown for each respective byte I/O31-I/O24, I/O25-I/O16, I/O15-I/O8, I/O7-I/O0. FIGURE 2: Erase Operation LEGEND: X = Don’t care RA = Address of the memory location to be read. RD = Data read from location RA during read operation. PA = Address of the memory location to be programmed. Addresses latch on the falling edge of the WEx\ or CEx\ pulse, whichever happens later. PD = Data to be programmed at location PA. Data latches on the rising edge of WEx\ or CEx\ pulse, whichever happens first. SA = Address of the sector to be verified (in autoselect mode) or erased. Address bits A16–A14 uniquely select any sector. NOTE: 1. See the appropriate Command Definitions table for program command sequence. 2. See "I/O3: Sector Erase Timer" for more information. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 8 FLASH AS8F128K32 WRITE OPERATION STATUS FIGURE 3: Data\ Polling Algorithm The device provides several bits to determine the status of a write operation: I/O3, I/O5, I/O6, and I/O7. Table 5 and the following subsections describe the functions of these bits. I/O7 and I/O6 each offer a method for determining whether a program or erase operation is complete or in progress. These three bits are discussed first. I/O7: Data\ Polling The Data\ Polling bit, I/O7*, indicates to the host system whether an Embedded Algorithm is in progress or completed. Data\ Polling is valid after the rising edge of the final WEx\ pulse in the program or erase command sequence. During the Embedded Program algorithm, the device outputs on I/O7* the complement of the datum programmed to I/O7*. When the Embedded Program algorithm is complete, the device outputs the datum programmed to I/O7*. The system must provide the program address to read valid status information on I/O7*. If a program address falls within a protected sector, Data\ Polling on I/O7* is active for approximately 2 ms, then the device returns to reading array data. During the Embedded Erase algorithm, Data\ Polling produces a “0” on I/O7*. When the Embedded Erase algorithm is complete, Data\ Polling produces a “1” on I/O7*. This is analogous to the complement/true datum output described for the Embedded Program algorithm: the erase function changes all the bits in a sector to “1”; prior to this, the device outputs the “complement,” or “0.” The system must provide an address within any of the sectors selected for erasure to read valid status information on I/O7*. After an erase command sequence is written, if all sectors selected for erasing are protected, Data\ Polling on I/O7* is active for approximately 100 ms, then the device returns to reading array data. If not all selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors that are protected. When the system detects I/O7* has changed from the complement to true data, it can read valid data at I/O7– I/O0 on the following read cycles. This is because I/O7* may change asynchronously with I/O0–I/O6 while Output Enable (OE\) is asserted low. The Data\ Polling Timings (During Embedded Algorithms) figure in the “AC Characteristics” section illustrates this. Table 5 shows the outputs for Data\ Polling on I/ O7*. Figure 3 shows the Data\ Polling algorithm. * * * NOTES: 1. VA = Valid address for programming. During a sector erase operation, a valid address is an address within any sector selected for erasure. During chip erase, a valid address is any non-protected sector address. 2. I/O7 should be rechecked even if I/O5 = “1” because I/O7 may change simultaneously with I/O5. *NOTE: applies to every 8th byte. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 9 FLASH AS8F128K32 I/O6: Toggle Bit I Toggle Bit I on I/O6 indicates whether an Embedded Program or Erase algorithm is in progress or complete. Toggle Bit I may be read at any address, and is valid after the rising edge of the final WEx\ pulse in the command sequence (prior to the program or erase operation), and during the sector erase time-out. During an Embedded Program or Erase algorithm operation, successive read cycles to any address cause I/O6 to toggle. (The system may use either OE\ or CEx\ to control the read cycles.) When the operation is complete, I/O6 stops toggling. After an erase command sequence is written, if all sectors selected for erasing are protected, I/O6 toggles or approximately 100 ms, then returns to reading array data. If not all selected sectors are protected, the Embedded Erase algorithm erases the unprotected sectors, and ignores the selected sectors that are protected. If a program address falls within a protected sector, I/O6 toggles for approximately 2 ms after the program command sequence is written, then returns to reading array data. The Write Operation Status table shows the outputs for Toggle Bit I on I/O6. Refer to Figure 4 for the toggle bit algorithm, and to the Toggle Bit Timings figure in the “AC Characteristics” section for the timing diagram. I/O5 through successive read cycles, determining the status as described in the previous paragraph. Alternatively, it may choose to perform other system tasks. In this case, the system must start at the beginning of the algorithm when it returns to determine the status of the operation (top of Figure 4). FIGURE 4: Toggle Bit Algorithm Reading Toggle Bit I/O6 Refer to Figure 4 for the following discussion. Whenever the system initially begins reading toggle bit status, it must read I/O7–I/O0 at least twice in a row to determine whether a toggle bit is toggling. Typically, a system would note and store the value of the toggle bit after the first read. After the second read, the system would compare the new value of the toggle bit with the first. If the toggle bit is not toggling, the device has completed the program or erase operation. The system can read array data on I/O7–I/O0 on the following read cycle. However, if after the initial two read cycles, the system determines that the toggle bit is still toggling, the system also should note whether the value of I/O5 is high (see the section on I/O5). If it is, the system should then determine again whether the toggle bit is toggling, since the toggle bit may have stopped toggling just as I/O5 went high. If the toggle bit is no longer toggling, the device has successfully completed the program or erase operation. If it is still toggling, the device did not complete the operation successfully, and the system must write the reset command to return to reading array data. The remaining scenario is that the system initially determines that the toggle bit is toggling and I/O5 has not gone high. The system may continue to monitor the toggle bit and * NOTES: 1. Read toggle bit twice to determine whether or not it is toggling. See text. 2. Recheck toggle bit because it may stop toggling as I/O5 changes to “1”. See text. *NOTE: applies to every 8th byte. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 10 FLASH AS8F128K32 I/O5: Exceeded Timing Limits I/O5* indicates whether the program or erase time has exceeded a specified internal pulse count limit. Under these conditions I/O5* produces a “1.” This is a failure condition that indicates the program or erase cycle was not successfully completed. The I/O5* failure condition may appear if the system tries to program a “1” to a location that is previously programmed to “0.” Only an erase operation can change a “0” back to a “1.” Under this condition, the device halts the operation, and when the operation has exceeded the timing limits, I/O5* produces a “1.” Under both these conditions, the system must issue the reset command to return the device to reading array data. I/O3: Sector Erase Timer After writing a sector erase command sequence, the system may read I/O3* to determine whether or not an erase operation has begun. (The sector erase timer does not apply to the chip erase command.) If additional sectors are selected for erasure, the entire timeout also applies after each additional sector erase command. When the time-out is complete, I/O3* switches from “0” to “1.” The system may ignore I/O3* if the system can guarantee that the time between additional sector erase commands will always be less than 50 ms. See also the “Sector Erase Command Sequence” section. After the sector erase command sequence is written, the system should read the status on I/O7* (Data\ Polling) or I/O6 (Toggle Bit I) to ensure the device has accepted the command sequence, and then read I/O3. If I/O3 is “1”, the internally controlled erase cycle has begun; all further commands are ignored until the erase operation is complete. If I/O3 is “0”, the device will accept additional sector erase commands. To ensure the command has been accepted, the system software should check the status of I/O3 prior to and following each subsequent sector erase command. If I/O3 is high on the second status check, the last command might not have been accepted. Table TABLE 5: Write Operation Status I/O71,* I/O7\ 0 OPERATION Embedded Program Algorithm Embedded Erase Algorithm NOTES: *applies to every 8th byte I/O52,* 0 0 I/O6* Toggle Toggle I/O3* N/A 1 1. I/O7 requires a valid address when reading status information. Refer to the appropriate subsection for further details. 2. I/O5 switches to ‘1’ when an Embedded Program or Embedded Erase operation has exceeded the maximum timing limits. See “I/O5: Exceeded Timing Limits” for more information. *Stresses greater than those listed under "Absolute Maximum Voltage with respect to Ground, VCC .............-2.0V to +7.0V Ratings" may cause permanent damage to the device. This is a stress rating only and functional operation of the device Voltage with respect to Ground, A9 2................-2.0V to +14V at these or any other conditions above those indicated in the Voltage with respect to Ground, All other pins 1-2.0V to +7.0V operation section of this specification is not implied. Exposure Short-circuit output current..........................................200mA to absolute maximum rating conditions for extended periods Ambient Temperature with power Applied.....-55°C to 125°C may affect reliability. Storage temperature range................................-65°C to 150°C NOTES: ABSOLUTE MAXIMUM RATINGS* 1 1. Minimum DC voltage on input or I/O pin is –0.5 V. During voltage transitions, inputs may overshoot VSS to –2.0 V for periods of up to 20 ns. See Figure 5. Maximum DC on input and I/O pins is VCC + 0.5 V. During voltage transitions, input and I/O pins may overshoot to VCC + 2.0 V for periods up to 20 ns. See Figure 6. 2. Minimum DC input voltage on A9 pin is –0.5V. During voltage transitions, A9 pins may overshoot VSS to –2.0 V for periods of up to 20 ns. See Figure 5. Maximum DC input voltage on A9 is +12.5 V which may overshoot to 14V for periods up to 20 ns. 3. No more than one output shorted at a time. Duration of the short circuit should not be greater than one second. FIGURE 5: Maximum Negative Overshoot AS8F128K32 Rev. 2.8 01/10 FIGURE 6: Maximum Positive Overshoot Micross Components reserves the right to change products or specifications without notice. 11 FLASH AS8F128K32 DC CHARACTERISTICS SYM CONDITION MAX UNIT Input Load Current ILI VIN = VSS to VCC, VCC = VCCMax ±10 µA A9 Input Load Current ILIT VCC = VCCMax, A9 = 12.5V 200 µA Output Leakage Current PARAMETER MIN ILO VOUT = VSS to VCC, VCC = VCCMax ±10 µA 1 ICC1 CEx\ = VIL, OE\ = VIH, VCC = VCCMax, f = 5MHz 140 mA 2,3 ICC2 CEx\ = VIL, OE\ = VIH, VCC = VCCMax, f = 5MHz 200 mA TTL/NMOS ICC3 VCC = VCCMax, CEx\ and OE\ = VIH, f = 5MHz 6.5 mA CMOS ICC3 VCC = VCCMax, CEx\ = VCC ± 0.3V, OE\ = VIH 2 mA VCC Active Current VCC Active Current VCC Standby Current Input Low Voltage VIL -0.5 0.8 V Input High Voltage VIH 2.0 VCC + 0.5 V Voltage for Autoselect and Temporary Sector Unprotect VID VCC = 5.0V 11.5 12.5 V Output Low Voltage VOL IOL = 12mA, VCC = VCCMin 0.45 V VOH IOH = -2.5mA, VCC = VCCMin 2.4 V VOH1 IOH = -2.5mA, VCC = VCCMin 0.85 VCC V VOH2 IOH = -100µA, VCC = VCCMin VCC -0.4 V TTL/NMOS Output High Voltage CMOS Low VCC Lock-out Voltage VLKO 3.2 4.2 NOTES: 1. The ICC current listed is typically less than 8 mA/MHz, with OE\ at VIH. 2. ICC active while Embedded Program or Embedded Erase Algorithm is in progress. 3. Not 100% tested. FIGURE 7: Test Setup TABLE 6: Test Specifications CONDITION Output Load Output Load Capacitiance, CL (Including jig capacitance) Input Rise and Fall Times Input Pulse Levels Input timing measurement reference levels Output timing measurement reference levels NOTE: ALL SPEEDS UNIT 1 TTL Gate 50 pF 5 0.0 - 0.3 ns V 1.5 V 1.5 V Diodes are IN3064 or equivalent. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 12 V FLASH AS8F128K32 AC CHARACTERISTICS SYMBOL JEDEC Standard PARAMETER Read-Only Operations 1 Read Cycle Time tAVAV tRC Address to Output Delay tAVQV tACC Chip Enable to Output Delay tELQV Output Enable to Output Delay Chip Enable to Output High Z 1,2 1,2 Output Enable to Output High Z Output Enable Hold Time ns Max 60 70 90 120 150 ns tCE Max 60 70 90 120 150 ns tGLQV tOE Max 30 35 40 50 55 ns tEHQZ tDF Max 20 20 25 30 35 ns tGHQZ tDF Max 20 20 25 30 35 ns tOEH Min -60 -70 -90 -120 -150 UNIT 60 70 90 120 150 1 Output Hold Time From Addresses CEx\ or OE\, Whichever Comes First Erase and Program Operations TEST SETUP CEx\ = VIL OE\ = VIL Read Toggle and Data Polling Min 0 ns Min 10 ns tAXQX tOH Min 0 ns tAVAV tWC Min 60 70 90 120 150 ns Address Setup Time tAVWL tAS Min 0 ns Address Hold Time tWLAX tAH Min 45 45 45 50 50 ns Data Setup Time tDVWH tDS Min 30 30 45 50 50 ns Data Hold Time tWHDX tDH Min 0 ns Read Recover Time Before Write (OE\ High to WEx\ Low) tGHWL tGHWL Min 0 ns CEx\ Setup Time tELWL tCS Min 0 ns CEx\ Hold Time tWHEH tCH Min 0 ns Write Pulse Width tWLWH tWP Min 30 35 45 Write Pulse Width High tWHWL tWPH Min 20 ns tWHWH1 tWHWH1 TYP 14 µs tWHWH2 tWHWH2 TYP 1.0 sec Min 50 µs Write Cycle Time 1 4 Byte Programming Operation 4 Sector Erase Operation VCC Setup Time 1 tVCS 50 50 ns NOTES: 1. Not 100% tested. 2. Output Driver Disable Time. 3. See Figure 7 and Table 6 for test specifications. 4. See the “Erase and Programming Performance” section for more information. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 13 FLASH AS8F128K32 FIGURE 8: Read Operations Timings FIGURE 9: Program Operations Timings NOTE: PA = program address, PD = program data, DOUT is the true data at the program address. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 14 FLASH AS8F128K32 FIGURE 10: Chip/Sector Erase Operations Timings 2AAh NOTE: SA = sector address (for Sector Erase), VA = Valid Address for reading status data (see “Write Operation Status”). FIGURE 11: Data\ Polling Timings (During Embedded Algorithms) NOTES: VA = Valid address. Illustration shows first status cycle after command sequence, last status read cycle, and array data read cycle. *applies to every 8th byte. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 15 FLASH AS8F128K32 FIGURE 12: Toggle Bit Timings (During Embedded Algorithms) NOTES: VA = Valid address; not required for I/O6. Illustration shows first two status cycle after command sequence, last status read cycle, and array data read cycle. *applies to every 8th byte. AC CHARACTERISTICS: Erase and Program Operations, Alternate CEx\ Controlled Writes SYMBOL JEDEC Standard DESCRIPTION -60 -70 -90 -120 -150 UNIT PARAMETER 1 tAVAV tWC Min 60 70 90 120 150 ns Address Setup Time tAVEL tAS Min 0 ns Address Hold Time tELAX tAH Min 45 45 45 50 50 ns Data Setup Time tDVEH tDS Min 30 30 45 50 50 ns Data Hold Time tEHDX tDH Min 0 ns tOES Min 0 ns Write Cycle Time 1 Output Enable Setup Time Read Recover Time Before Write tGHEL tGHEL Min 0 ns WEx\ Setup Time tEHWH tWS Min 0 ns WEx\ Hold Time tEHWH tWH Min 0 ns CEx\ Pulse Width tELEH tCP Min 30 35 45 CEx\ Pulse Width High tEHEL tCPH Min 20 ns 2 tWHWH1 tWHWH1 TYP 14 µs 2 tWHWH2 tWHWH2 TYP 1.0 sec Byte Programming Operation Chip/Sector Erase Operation 50 50 ns NOTES: 1. Not 100% tested. 2. See the “Erase and Programming Performance” section for more information. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 16 FLASH AS8F128K32 FIGURE 13: Alternate CEx\ Controlled Write Operation Timings 555 for program 2AA for erase PA for program SA for sector erase 555 for chip erase NOTES: 1. PA = Program Address, PD = Program Data, SA = Sector Address, I/O7\ = Complement of Data Input, DOUT = Array Data. 2. Figure indicates the last two bus cycles of the command sequence. ERASE AND PROGRAMMING PERFORMANCE LIMITS PARAMETER TYP Chip/Sector Erase Time Byte Programming Time Chip Programming Time 3 1.0 14 1.8 1 2 MAX UNIT 15 1000 12.5 sec µs sec COMMENTS Excludes 00h programming prior to erasure 4 Excludes system-level overhead5 NOTES: 1. Typical program and erase times assume the following conditions: 25° C, 5.0 V VCC, 100,000 cycles. Additionally, programming typicals assume checkerboard pattern. 2. Under worst case conditions of 90°C, VCC = 4.5 V (4.75 V for -45, -55 PDIP), 100,000 cycles. 3. The typical chip programming time is considerably less than the maximum chip programming time listed, since most bytes program faster than the maximum byte program time listed. If the maximum byte program time given is exceeded, only then does the device set I/O5 = 1. See the section on I/O5 for further information. 4. In the pre-programming step of the Embedded Erase algorithm, all bytes are programmed to 00h before erasure. 5. System-level overhead is the time required to execute the four-bus-cycle command sequence for programming. See Table 1 for further information on command definitions. 6. The device has a typical erase and program cycle endurance of 1,000,000 cycles. 100,000 cycles are guaranteed. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 17 FLASH AS8F128K32 CAPACITANCE PARAMETER SYMBOL CONDITIONS MAX UNIT CIN VIN = 0 50 pF CSx\ & WEx\ Capacitance COUT VOUT = 0 20 pF I/O0 - I/O31 Capacitance CIN2 VIN = 0 20 pF A0 - A16 Capacitance NOTES: 1. Sampled, not 100% tested. 2. Test conditions TA = 25° C, f = 1.0 MHz. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 18 FLASH AS8F128K32 MECHANICAL DEFINITIONS* Micross Case #703 (Package Designator Q) SMD 5962-94716, Case Outlines M & N D2 D1 DETAIL A D R 1o - 7o b L1 e SEE DETAIL A A c A2 E SYMBOL A A2 b c D D1 D2 E e R L1 SMD SPECIFICATIONS, CASE N MIN MAX 0.123 0.160 0.005 0.025 0.013 0.017 0.009 0.012 0.800 BSC 0.870 0.890 0.980 1.000 0.936 0.956 0.050 BSC 0.010 BSC 0.035 0.045 SYMBOL A A2 b c D D1 D2 E e R L1 SMD SPECIFICATIONS, CASE M MIN MAX 0.123 0.200 0.005 0.025 0.013 0.017 0.009 0.012 0.800 BSC 0.870 0.890 0.980 1.000 0.936 0.956 0.050 BSC 0.010 BSC 0.035 0.045 *All measurements are in inches. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 19 FLASH AS8F128K32 MECHANICAL DEFINITIONS* Micross Case (Package Designator Q1) SMD 5962-94716, Case Outline A SYMBOL A A1 b B c D/E D1/E1 D2/E2 e L R SMD SPECIFICATIONS MIN MAX --0.200 0.054 --0.013 0.017 0.010 TYP 0.009 0.012 0.980 1.000 0.870 0.890 0.800 BSC 0.050 BSC 0.035 0.045 0.010 TYP *All measurements are in inches. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 20 FLASH AS8F128K32 ORDERING INFORMATION EXAMPLE: AS8F128K32Q-70/XT Device Number AS8F128K32 AS8F128K32 AS8F128K32 AS8F128K32 AS8F128K32 Package Type Q Q Q Q Q Speed ns -60 -70 -90 -120 -150 Process /* /* /* /* /* EXAMPLE: AS8F128K32Q1-120/883C Device Number AS8F128K32 AS8F128K32 AS8F128K32 AS8F128K32 AS8F128K32 Package Type Q1 Q1 Q1 Q1 Q1 *AVAILABLE PROCESSES IT = Industrial Temperature Range XT = Extended Temperature Range 883C = Full Military Processing Q = Full QML Processing AS8F128K32 Rev. 2.8 01/10 Speed ns -60 -70 -90 -120 -150 Process /* /* /* /* /* -40oC to +85oC -55oC to +125oC -55oC to +125oC -55oC to +125oC Micross Components reserves the right to change products or specifications without notice. 21 FLASH AS8F128K32 MICROSS TO DSCC PART NUMBER* CROSS REFERENCE Micross Package Designator Q Micross Part # SMD Part # AS8F128K32Q-150/Q AS8F128K32Q-120/Q AS8F128K32Q-90/Q AS8F128K32Q-70/Q AS8F128K32Q-60/Q 5962-9471601HNX 5962-9471602HNX 5962-9471603HNX 5962-9471604HNX 5962-9471605HNX AS8F128K32Q-150/Q AS8F128K32Q-120/Q AS8F128K32Q-90/Q AS8F128K32Q-70/Q AS8F128K32Q-60/Q 5962-9471601HMX 5962-9471602HMX 5962-9471603HMX 5962-9471604HMX 5962-9471605HMX Micross Package Designator Q1 Micross Part # SMD Part # AS8F128K32Q1-150/Q AS8F128K32Q1-120/Q AS8F128K32Q1-90/Q AS8F128K32Q1-70/Q AS8F128K32Q1-60/Q 5962-9471601HAX 5962-9471602HAX 5962-9471603HAX 5962-9471604HAX 5962-9471605HAX * Micross part number is for reference only. Orders received referencing the SMD part number will be processed per the SMD. AS8F128K32 Rev. 2.8 01/10 Micross Components reserves the right to change products or specifications without notice. 22