emi power filters & film capacitors EMI Power Filters & Film Capacitors find the ideal method to filter the AC or DC power entering your system to prevent radiated or conducted EMI with our line of standard power filters and custom power solutions Power Entry Modules, Power Line & 3 Phase Power Filters are designed in multiple configurations to cover a range of industrial applications. These have excellent attenuation for high voltage impulse, are available in single and dual stage and address FCC Part 15 regulations while meeting your power filtering needs… PF5-PF6 & PF16-PF89 Single Line Feed-Through (SLFT) Power Filters provide superior filtering in a compact, durable package with single, dual, and triple feed-throughs available. These filters are ideal for meeting broad frequency applications with a bolt-in style for easy installation… PF7-PF14 Military/Aerospace Multisection Filters provide excellent EMI filtering for demanding high reliability applications. We offer standard filters, as well as custom designed mechanical packages for unusual or tight fitting spaces and higher performance filtering and expanded voltage ratings… PF91-PF98 EMI Power Filter Solutions will lower your costs and reduce your time to market while providing your system with protection from radiated or conducted EMI. Our comprehensive consulting, diagnostic testing and world class manufacturing allows us to meet your design/project parameters… PF99 Power Film Capacitors deliver high reliability, low inductance, low ESR and low DF with a high peak withstanding voltage. These ruggedized capacitors come in a wide range of dielectrics, various geometries, a variety of terminations, multiple sizes and electrical ratings of 250-15KVDC typical, ripple currents up to 400 Arms and 150°C operation… PF100 Audio Film Capacitors with multiple dielectrics in metalized film and film/foil construction. High quality capacitors specially designed for audio applications… PF102 EMI Filter Expertise We differentiate ourselves from typical filter suppliers by offering our customers an integrated approach to EMC problem solving through consulting, diagnostic testing, design and manufacturing. ■ In-house test facilities to provide a total solution for your compliance issues – anechoic chamber, shielded room and NARTE certified engineers ready to test for European emission and immunity regulations, FCC Part 15 and MIL standards ■ ■ ■ ■ Global manufacturing and design support with agency approved products available Engineering expertise and vertical integration reduce your time to market and save you money High reliability products with low leakage and nonmagnetic options available Available to meet MIL-PRF-15733 and MIL-STD-461 standards API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF2 Application Guidelines Need for EMI suppression Global regulatory agencies have established limits to the amount of noise that man-made electronic devices can radiate or conduct. These regulations have gained greater importance as the world’s electronic population intensifies and the proximity of electronic devices becomes closer. Power Filter Installation EMI can propagate through two basic avenues: Conducted and Radiated Conducted refers to events where the EMI energy flowsthrough power lines, data cables and other wiring that carries functional data or power. Radiated refers to energy that is propagated by magnetic or electric fields, which originate from other electronic or electrical systems. INCORRECT CORRECT CABINET POWER INPUT DENOTES COUPLING FROM NOISY CIRCUITS BACK TO LINE CABINET DENOTES COUPLING FROM NOISY CIRCUITS BACK TO LINE POWER INPUT Interference types There are two modes of conducted noise: differential mode (symmetrical or normal mode) and common mode (asymmetrical mode). Differential mode interference signals are present on one side of the line, referenced to the other. The currents flow along one phase and return along another phase. Common mode interference signals are present on both sides of the line referenced to ground. The current flows from the source to ground along the ground path and returns along the phases. Sources of EMI Electromagnetic interference can occur naturally or through electronic sources. Lightning discharges, precipitation, sand and dust storms, and cosmic noise are sources of natural EMI. EMI generated from power electrical products cause the most concern. These man-made sources, such as power lines, rotating machinery, power supplies and electronic transmission devices, all have their own signatures and noise pollution. EMI filters, insertion loss and attenuation Power line EMI filters are designed to attenuate (or reduce) all radio frequency emissions or energy that is above the applicable EMC specification. Most power line EMI filters utilize inductor/capacitor “low pass” component configurations that pass all DC or low frequency AC necessary energy and attenuate (suppress) higher frequencies containing noise or unwanted energy. LINE FILTER CLEAN LINE LINE FILTER To insure a customer’s “in system” unit to unit attenuation uniformity of power line filters, an insertion loss production line test is performed by API Technologies. Each of the specific frequencies is measured using RF test equipment and the “reference signal level” of each frequency is stored. Some systems sweep the entire frequency range and store this “reference signal level”. The filter to be measured, tested, or evaluated is then “inserted” between the generator and receiver that established the stored “reference signal level” on the RF test analyzer. The measured difference without a filter (“the reference signal level”) and with the filter “inserted” into the RF test equipment/analyzer is defined as insertion loss. The unit of measure for insertion loss is the decibel (dB). As noted on most curves in this bulletin, as frequency increases, the higher the insertion loss or dB value. The plot of frequency versus dB value establishes the typical insertion loss curve. Installation Criteria Proper installation of a filter network is critical to achieving successful filtering of electromagnetic interference. API recommends that power line filters be installed where the power line enters the equipment. The filter acts as a barrier between polluted energy and clean energy going into your equipment. It is important that the filter is connected to an effective ground plane and where proximity does not couple radiated noise to the clean lines. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF3 Measurement Guidelines API Technologies has the capability to perform a wide range of tests for EMI filters. Unique custom testing systems designed by Spectrum assure the accuracy required in today’s demanding environments. Testing is performed by employing a 50 ohm source and load impedance per MIL-STD-220. The individual filter performance is stated in terms of insertion loss. Overall attenuation reflects the filter’s interaction within the system. Individual filter performance may differ from system to system and each application should be verified through system testing. Examples of various testing abilities and configurations are outlined below. Differential (Normal or Symmetrical) Mode Insertion Loss Differential mode noise is caused by non-sinusoidal conduction of rectifiers and other switching devices creating harmonic distortion. This noise is predominant from the power frequency to approximately 10 MHz. Since it follows conventional current flow, it is considered to be of the same magnitude but opposite phase of the other line. Spectrum measures differential mode insertion loss in a 50 ohm system with Balun transformers as shown. Leakage Current Leakage is a measurement of reactive current (capacitance) to ground per line. Spectrum uses the following test setup for leakage current measurement. TIES TO CHASSIS OF DEVICE DEVICE UNDER TEST 1 AC SOURCE 2 0.15 µFD 1 NEUTRAL TEST 2 HIGH TEST 1.5 KΩ v IN ACCORDANCE WITH U.L. 1283 METHOD AC Voltage Drop AC voltage drop is defined as E in - E out = AC voltage drop. Spectrum Control uses the following circuit for AC voltage drop testing: A DUT (FILTER) E1 BALUN INSULTATED TABLE E2 BALUN FILTER ØA 50Ω FILTER ØB SIGNAL GENERATOR 50Ω RECEIVER Common (Asymmetrical) Mode Insertion Loss E VD Since common mode insertion loss is of the same phase as the opposite line, they may not be of the same magnitude, depending on the end system circuitry. Spectrum Control tests common mode insertion loss on each line in a 50 ohm system as shown. 50Ω LINE DUT (FILTER) A RS LINE 50Ω FILTER NEUT DC Voltage Drop DC voltage drop is performed on each line individually. This test provides the total DC voltage drop for that line of the filter. The following circuit is used in testing: FILTER ØC RECEIVER NEUT API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF4 Power Entry Modules, Power Line Filters & 3 Phase Power Filters Part Numbering System Part Numbering System Example: 12-PMB-025-5-A Part number 12-PMB-025-5A represents a power line filter with threaded studs, current rated for 25 Amps and with a leakage current of 0.50 mA. 12 - PMB - Product Line Series Product Style 10 = Filtered IEC Inlets 11 = Printed Circuit Board Mount 12 = Power Line Filters 13 = Three Phase Power Line Filters 14 = Fused or Switched & Fused Power Entry Filters (250V) 15 = Switched & Dual Fused 16 = Single Phase (250V) BBF = 3 Phase, terminal block connection BFF = Bolt-in fused filter BPF = Bolt-in IEC w/Fast-on rear terminals BPL = Bolt-in IEC w/wire lead termination BSF = Bolt-in switched & fused CCL = Cylindrical, capacitive inputs w/Fast-ons CLF = Cylindrical, inductive inputs w/wire leads MMB = Multiple stage filtering w/threading studs MMF = Multiple stage filtering w/Fast-on terminal MPC = Miniature PCB mountable PDB = 3 Phase, delta w/threaded studs PDF = 3 Phase, delta w/Fast-ons PDL = 3 Phase, delta w/wire leads PMB = Power line filter w/threaded studs PMF = Power line filter w/Fast-ons PML = Power line filter w/wire leads PWB = 3 Phase, wye w/threaded studs PWE = 3 Phase, wye w/busbar PWF = 3 Phase, wye w/Fast-ons PWL = 3 Phase, wye w/wire leads 025 Current Rating 001 002 003 005 006 010 015 016 020 025 030 035 050 080 100 150 160 200 300 400 500 600 = = = = = = = = = = = = = = = = = = = = = = 1.0 Amp 2.0 Amps 3.0 Amps 5.0 Amps 6.0 Amps 10 Amps 15 Amps 16 Amps 20 Amps 25 Amps 30 Amps 35 Amps 50 Amps 80 Amps 100 Amps 150 Amps 16.0 Amps 200 Amps 300 Amps 400 Amps 500 Amps 600 Amps - 5 - A Leakage Current (Y Cap) Outline Drawing/ Case Style 250 VAC 125VAC 0 = 0.075 mA DC = DC 1 = 0.01 mA 2 = 0.20 mA 3 = 0.35 mA 4 = 0.10mA 5 = 0.50 mA 6 = 0.60 mA 7 = 0.70 mA 8 = 1.0 mA 9 = 3.0 mA 10 = 2.0 mA 11 = 1.5 mA 12 = 4.5 mA 13 = 9.0 mA 14 = 20.0 mA 15 = 15.0 mA 17 = 33.0 mA 18 = 71.5 mA DC = DC 1 Select case style from following * Cylindrical * Power line w/Fast-on * Power line w/threaded studs * Power line w/wire leads * PCB mount * Large case 3 Phase delta * Large case 3 Phase wye * IEC Inlet 2 Refer to drawing list per selected case style 3 Letter at the end of the part is found in the case style drawing list: A, B, C, D, E, F, etc. * Note: Not all series offer the product style, rating and leakage current API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF5 Power Entry Modules, Power Line Filters & 3 Phase Power Filters Part Numbering System Part Numbering System Example: 60-BPR-060-5-4 Part number 60-BPR-060-5-4 represents a power entry module, bolt-in style with fast-on terminals, a current rating of 6 Amps, leakage current of 0.50 mA and capacitance of 0.047 µF. 60 - BPR - Product Line Series Product Style 60 = Power Entry Modules 61 = Mini PCB Power Filters 62 = Power Line Filters 63 = Three Phase Power Line Filters 64 = Fused or Switched & Fused Power Entry Filters (250V) 65 = Fused or Switched & Fused Power Entry Filters (125V) 66 = Fused or Switched & Fused Low Leakage Power Entry Filters (250V) 67 = Fused or Switched & Fused Low Leakage Power Entry Filters (125V) 68 = Switched & Dual Fused Power Entry Filters 69 = Dual Fused Only or Dual Switched Only Power Entry Filters AFL = Appliance filter w/ inductive input AFC = Appliance filter w/ capacitive input ARL = AFL plus bleeder resistor BFF = Fused filter w/ Fast-on terminals BFS = Fused filter w/solder lug terminals BHP = High frequency bolt-in for PCB BHS = High frequency bolt-in w/solder lugs BPF = Bolt-In right angle terminals BPL = Bolt-in w/wire leads BPP = Bolt-in PCB mount BPR = Bolt-in w/Fast-on tab terminals BPS = Bolt-in w/ solder lug terminals BSF = Bolt-in switched & fused MMF = Metal case w/fast-on tabs MPC = Miniature printed circuit board PMB = Metal case w/bolt-on terminals PMF = Metal case w/Fast-on tabs PML = Metal case w/wire leads PPF = Plastic case w/Fast-on tabs PQF = Plastic case w/Fast-on tabs PRF = Plastic case w/Fast-on tabs SOF = Switched filter w/ Fast-on tabs SOS = Switched filter w/ solder tabs SPL = Snap-in w/wire leads SPR = Snap-in w/Fast-on terminals SPS = Snap-in w/solder lug terminals SSF = Snap-in switched & fused ARC = AFC plus bleeder resistor 060 - Current Rating 010 015 016 020 030 040 050 060 080 100 150 160 200 300 400 = = = = = = = = = = = = = = = 1.0 Amps 1.5 Amps 1.6 Amps 2.0 Amps 3.0 Amps 4.0 Amps 5.0 Amps 6.0 Amps 8.0 Amps 10.0 Amps 15.0 Amps 16.0 Amps 20.0 Amps 30.0 Amps 40.0 Amps 5 - Leakage Current (Y Cap) 0 1 2 3 4 5 6 7 8 9 250 VAC = 0.075 mA = 0.01 mA = 0.20 mA = 0.35 mA = 0.10 mA = 0.50 mA = 0.60 mA = 0.70 mA = 1.00 mA = 3.00 mA 0 1 3 4 5 6 7 8 9 125VAC = 0.035 mA = 0.005 mA = 0.35 mA = 0.05 mA = 0.50 mA = 0.60 mA = 0.70 mA = 1.00 mA = 3.00 mA 4 Capacitance (X Cap) 0 1 2 3 4 5 6 01 02 04 06 10 11 12 13 14 16 21 = = = = = = = = = = = = = = = = = = none 0.01µF 0.022µF 0.033µF 0.047µF 0.050µF 0.068µF 2 x 0.01µF 0.10µF & 0.22µF 2 x 0.22µF 2 x 0.4µF & 0.22µF 0.15µF 0.10µF 0.22µF 0.33µF 0.47µF 0.22µF & 2 x 0.33µF 1.00µF * Note: Not all series offer the product style, rating and leakage current API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF6 High Current DC Single Line Feed-through Series Features ■ ■ ■ ■ ■ ■ ■ ■ ■ Voltage rating of 130VDC C configuration with Class Y4 capacitors Current rating up to 300 Amps Operating temperature range: -40°C to +85°C Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution Design flexibility UL and Semko approved Applications ■ ■ ■ ■ ■ ■ Telecommunications (cellular base stations, telephone switching racks, etc.) Power supplies Medical equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data transmission equipment Specifications Part Number 52F226-011-10 52F226-011-16 52F226-011-32 52F226-011-63 52F226-011-100 52F226-011-200 52F226-011-250 52F226-011-300 52F226-021-16 52F226-021-32 52F226-021-63 52F226-021-100 52F226-021-200 52F226-021-250 52F226-021-300 52F226-031-16 52F226-031-32 52F226-031-63 52F226-031-100 52F226-031-200 52F226-031-250 52F226-031-300 52F226-041-16 52F226-041-32 52F226-041-63 52F226-041-100 52F226-041-200 Rated Current 10A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A Min. Cap. .01MHz 10nF .10MHz Minimum Insertion Loss (db)* 1MHz 10MHz 100MHz 1000MHz – 4 21 41 60 2 15 34 53 74 100nF 5 21 40 60 85 47nF 2 15 34 53 74 100nF 5 21 40 60 85 47nF – 470nF 2 16 33 52 75 90 100nF – 5 21 40 60 85 470nF 2 16 33 52 75 1000nF 6 20 40 60 85 470nF 2 16 33 52 75 1000nF 4700nF 6 15 20 35 40 54 60 74 85 90 90 * Optimum performance with proper installation API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF7 High Current DC Single Line Feed-through Series F B E WORKORDER NO. C D DATE CODE SINGLE "D" MOUNTING FLAT .025 (.64) SHOULDER A Dimensions Part Number 52F226-011-10 52F226-011-16 52F226-011-32 52F226-011-63 52F226-011-100 52F226-011-200 52F226-011-250 52F226-011-300 52F226-021-16 52F226-021-32 52F226-021-63 52F226-021-100 52F226-021-200 52F226-021-250 52F226-021-300 52F226-031-16 52F226-031-32 52F226-031-63 52F226-031-100 52F226-031-200 52F226-031-250 52F226-031-300 52F226-041-16 52F226-041-32 52F226-041-63 52F226-041-100 52F226-041-200 A B C D E 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16) 2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.12 (130) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.06 (27) 1.25 (31.75) 1.02 (26) 1.26 (32) 1.57 (40) 1.57 (40) 2 (50.80) 1.81 (46) 5.83 (148) 0.75 (19) F 2.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.12 (130) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.06 (27) 1.25 (31.75) 1.02 (26) 1.26 (32) 1.57 (40) 1.57 (40) 2 (50.80) 1.81 (46) 6.30 (160) 0.75 (19) 0.71 (18) 1.18 (30) 1.30 (33) 1.65 (42) 1.18 (30) 1.30 (33) 2.13 (54) 2.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.79 (147) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 1.57 (40) 1.30 (33) 1.97 (50) 2 (50.80) 1.81 (46) 2.83 (72) 7.01 (178) 3.23 (82) 3.98 (101) 5.24 (133) 6.50 (165) 0.75 (19) 0.63 (16) 0.75 (19) 1.06 (27) 1.57 (40) 1.06 (27) 1.57 (40) 1.25 (31.75) 1.5 (38.10) 2 (50.80) 0.71 (18) 1.02 (26) 1.26 (32) 1.57 (40) 1.18 (30) 1.30 (33) 1.97 (50) 2.68 (68) Dimensions in inches (mm) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF8 High Current DC Single Line Pi Series Features ■ ■ ■ ■ ■ ■ ■ Voltage rating of 130VDC Pi configuration with Class Y4 capacitors Current rating up to 200 Amps Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution UL and Semko approved Applications ■ ■ ■ ■ ■ ■ Telecommunications (cellular base stations, telephone switching racks, etc.) Power supplies Medical equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data transmission equipment Circuit Diagram Specifications Part Number Standard Performance 52F226-020-10 52F226-020-16 52F226-020-32 52F226-020-63 52F226-020-100 52F226-020-200 High Performance 52F226-029-10 52F226-029-16 52F226-029-32 52F226-029-63 52F226-029-100 52F226-029-200 Rated Current 10A 16A 32A 63A 100A 200A 10A 16A 32A 63A 100A 200A Min. Cap. (2X) 10nF .01MHz – .10MHz Minimum Insertion Loss (db) * 1MHz 10MHz 100MHz 0.5 8 10 27 23 35 23 67 70 60 470nF 4 7 2 8 21 23 100nF – 8 25 75 470nF 1000nF 4700nF 4 8 20 21 26 40 35 57 85 70 73 90 100nF 30 1000MHz 70 50 90 90 90 90 * Optimum performance with proper installation API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF9 High Current DC Single Line Pi Series A B F E C D SINGLE "D" MOUNTING FLAT DATE CODE WORKORDER NO. .025 (.64) SHOULDER Dimensions Part Number Standard Performance 52F226-020-10 52F226-020-16 52F226-020-32 52F226-020-63 52F226-020-100 52F226-020-200 High Performance 52F226-029-10 52F226-029-16 52F226-029-32 52F226-029-63 52F226-029-100 52F226-029-200 A B C D 0.47 (12) 0.67 (17) 0.75 (19.05) 0.55 (14) 0.63 (16) 0.75 (19) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.50 (38.10) 3.54 (90) 3.86 (98) 6.30 (160) 7.24 (184) 8.23 (209) 1.06 (27) 5.12 (130) 5.47 (139) 6.81 (173) 8.98 (228) 11 (279) 0.47 (12) 0.63 (16) 0.75 (19) 0.67 (17) 1.06 (27) 1.57 (40) 0.75 (19.05) 1.25 (31.75) 1.50 (38.10) 2 (50.80) E F 0.63 (16) 1.93 (49) 0.71 (18) 2.09 (53) 1.02 (26) 1.26 (32) 1.57 (40) 3.70 (94) 4.09 (104) 4.41 (112) 0.63 (16) 3.50 (89) 0.71 (18) 3.70 (94) 1.02 (26) 1.26 (32) 1.57 (40) 4.13 (105) 5.71 (145) 7.17 (182) Dimensions in inches (mm) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF10 High Current AC Single Line Feed-through Series Features ■ ■ ■ ■ ■ ■ ■ ■ Voltage rating of 250VAC C configuration with Class Y2 capacitors Current rating up to 300 Amps Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution Design flexibility UL and Semko approvals pending Applications ■ ■ ■ ■ ■ ■ Telecommunications (cellular base stations, telephone switching racks, etc.) Power supplies Medical equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data transmission equipment Specifications Part Number 52F226-016-10 52F226-016-16 52F226-016-32 52F226-016-63 52F226-016-100 52F226-016-200 52F226-016-250 52F226-016-300 52F226-026-10 52F226-026-16 52F226-026-32 52F226-026-63 52F226-026-100 52F226-026-200 52F226-026-250 52F226-026-300 52F226-036-16 52F226-036-32 52F226-036-63 52F226-036-100 52F226-036-200 52F226-036-250 52F226-036-300 52F226-046-16 52F226-046-32 52F226-046-63 52F226-046-100 52F226-046-200 52F226-046-250 52F226-046-300 Rated Current Min. Cap. 10A 16A 32A 63A 100A 200A 250A 300A 10A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A 250A 300A 16A 32A 63A 100A 200A 250A 300A 2.2nF .01MHz .10MHz Minimum Insertion Loss (db) * 1MHz 10MHz 100MHz 1000MHz - 9 30 45 4.7nF – 2 15 34 54 10nF 47nF 2 4 15 21 34 41 53 60 74 100nF 5 21 40 60 85 2 15 34 54 4 21 41 60 4.7nF 10nF – – 47nF 100nF 2 5 15 21 34 40 53 60 74 85 220nF 10 27 47 67 90 47nF 33nF 100nF 220nF 2 3 5 10 15 16 21 27 34 35 40 47 16 33 52 75 2 5 2 10 16 21 15 27 33 40 34 47 52 60 53 67 75 6 20 40 60 85 470nF 100nF 47nF 220nF 470nF 1000nF 2 – 53 60 67 74 90 85 90 85 74 90 * Optimum performance with proper installation API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF11 High Current AC Single Line Feed-through Series B F WORKORDER NO. C E D SINGLE "D" MOUNTING FLAT DATE CODE .025 (.64) SHOULDER A Dimensions Part Number 52F226-016-10 52F226-016-16 52F226-016-32 52F226-016-63 52F226-016-100 52F226-016-200 52F226-016-250 52F226-016-300 52F226-026-10 52F226-026-16 52F226-026-32 52F226-026-63 52F226-026-100 52F226-026-200 52F226-026-250 52F226-026-300 52F226-036-16 52F226-036-32 52F226-036-63 52F226-036-100 52F226-036-200 52F226-036-250 52F226-036-300 52F226-046-16 52F226-046-32 52F226-046-63 52F226-046-100 52F226-046-200 52F226-046-250 52F226-046-300 A B C D E 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16) 2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.12 (130) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 1.57 (40) 1.57 (40) 2 (50.80) 1.81 (46) 5.83 (148) 0.75 (19) 1.06 (27) F 2.24 (57) 0.39 (10) 0.51 (13) 0.56 (14.29) 0.63 (16) 2.48 (63) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.45 (113) 5.12 (130) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 1.57 (40) 1.57 (40) 2 (50.80) 1.81 (46) 5.83 (148) 0.75 (19) 1.06 (27) 0.71 (18) 1.18 (30) 1.30 (33) 1.65 (42) 0.71 (18) 1.18 (30) 1.30 (33) 1.65 (42) 2.95 (75) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.71 (18) 3.78 (96) 4.57 (116) 5.79 (147) 0.55 (14) 0.87 (22) 1.06 (27) 1 (25.40) 1.02 (26) 1.26 (32) 1.57 (40) 1.30 (33) 1.97 (50) 2 (50.80) 1.81 (46) 2.13 (54) 0.87 (22) 0.67 (17) 1 (25.40) 0.71 (18) 1.18 (30) 1.06 (27) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 1.57 (40) 1.30 (33) 0.75 (19) 6.30 (160) 3.03 (77) 2.95 (75) 4.45 (113) 5.24 (133) 5.79 (147) 6.30 (160) 0.55 (14) 0.47 (12) 0.63 (16) 0.75 (19) 1.57 (40) 1.57 (40) 1.5 (38.10) 2 (50.80) 1.81 (46) 1.18 (30) 1.97 (50) 2.13 (54) Dimensions in inches (mm) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF12 High Current AC Single Line Pi Series Features ■ ■ ■ ■ ■ ■ ■ ■ Voltage rating of 250VAC Pi configuration with Class Y2 capacitors Current rating up to 300 Amps Excellent filtering in compact package Bolt-in style with D-shaped bushing for easy installation Low cost EMI solution Design flexibility UL and Semko approvals pending Circuit Diagram Applications ■ ■ ■ ■ ■ ■ Telecommunications (cellular base stations, telephone switching racks, etc.) Power supplies Medical equipment C.O.T.S. (Commercial-Off-The-Shelf) Military Industrial equipment controls Data transmission equipment Specifications Part Number Standard Performance 52F226-037-10 52F226-037-16 52F226-037-32 52F226-037-63 52F226-037-100 52F226-037-200 52F226-037-250 52F226-037-300 High Performance 52F226-019-10 52F226-019-16 52F226-019-32 52F226-019-63 52F226-019-100 52F226-019-200 52F226-019-250 52F226-019-300 Rated Current Min. Cap. (2X) 10A 16A 32A 63A 100A 200A 250A 300A 4.7nF 10A 16A 32A 63A 100A 200A 250A 300A 10nF .01MHz – 47nF 100nF 1 10nF 22nF – .10MHz Minimum Insertion Loss (db) * 1MHz 10MHz 100MHz – 4 19 77 1 8 22 50 4 8 21 25 52 73 80 9 26 75 1 9 30 3 15 47 27 39 75 150nF 1 12 470nF 4 21 57 85 1000MHz 90 90 80 90 90 * Optimum performance with proper installation API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF13 High Current AC Single Line Pi Series A B F E C D SINGLE "D" MOUNTING FLAT DATE CODE WORKORDER NO. .025 (.64) SHOULDER Dimensions Part Number Standard Performance 52F226-037-10 52F226-037-16 52F226-037-32 52F226-037-63 52F226-037-100 52F226-037-200 52F226-037-250 52F226-037-300 High Performance 52F226-019-10 52F226-019-16 52F226-019-32 52F226-019-63 52F226-019-100 52F226-019-200 52F226-019-250 52F226-019-300 A B C D E F 0.47 (12) 0.67 (17) 0.75 (19.05) 0.63 (16) 0.71 (18) 2.24 (57) 2.40 (61) 0.55 (14) 0.63 (16) 0.87 (22) 1 (25.40) 1.25 (31.75) 1.02 (26) 1.26 (32) 1.57 (40) 3.7 (94) 4.09 (104) 4.41 (112) 1.81 (46) 3.66 (93) 3.86 (98) 4.17 (106) 6.30 (160) 7.24 (184) 8.23 (209) 7.87 (200) 0.75 (19) 1.06 (27) 1.57 (40) 1.5 (38.10) 4.21 (107) 0.47 (12) 0.67 (17) 0.75 (19.05) 0.63 (16) 2.6 (66) 4.57 (116) 0.55 (14) 0.87 (22) 1 (25.40) 0.71 (18) 2.72 (69) 6.81 (173) 8.98 (228) 9.57 (243) 0.63 (16) 1.06 (27) 1.25 (31.75) 1.5 (38.10) 1.02 (26) 1.26 (32) 4.13 (105) 5.71 (145) 5.75 (146) 1.57 (40) 2 (50.80) 1.57 (40) 10.5 (267) 0.75 (19) 6.30 (160) Dimensions in inches (mm) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF14 High Current Filtered Terminal Blocks Features ■ ■ ■ ■ Ideal for high current applications Design flexibility Available in 2 x 2 through 2 x 6 positions UL approved Specifications Applications ELECTRICAL Voltage rating: Capacitance: Telecommunications switching networks ■ Cellular base stations ■ Power supplies ■ UPS ■ Instrumentation ■ High reliability radar and transmission systems ■ Industrial controls ■ Power distribution ■ 4.600 (116.8) Dielectric withstanding voltage: 1000VDC for 1 minute Current rating: 60 Amps max per terminal Typical Insertion Loss — dB: In 50 Ohm Circuit 1 5 10 50 8-32 THREADED INSERTS (4X) 1.625 (41.3) .65 MIN (16.5) (6X) 1.10 (27.9) .80 MIN (20.3) .75 (19.0) (5X) .172 (4.3) (4X) MHz......... 36 MHz......... 33 MHz......... 25 MHz......... 25 US .200: (5.08 mm) AWG #12-26 Steel, zinc chromate plate .05" (1.30 mm) contact hole UL rated 94VO polyamide 2.5 in.-lbs. max. (28 Ncm) Brass, tin-plated * For filter elements with additional capacitance values, consult factory. PANEL CUTOUT 4.6 (116.8) 5.0 (127) 5.0 (127) 5.6 (142.2) 52-1013-102 70 100 160 200 1.685 2.025 (42.8) (51.4) 2.625 2.025 .75 (19.0) (66.7) (51.4) Part Number MHz....... 8 MHz....... 24 MHz....... 32 MHz....... 38 MECHANICAL Center spacing: Wire size: Screw material: Recommended PCB hole diameter: Molded material: Tightening torque: Terminal: R.125 (3.2) (4X) 1.15 (29.1) 100 VDC per terminal .015µF* +80% / -20% per cap .030µF +80% / -20% per pair Number of Terminals in. 2x2 2.60 A (mm) in. 66.04 2.00 B (mm) in. 50.80 1.66 C (mm) 42.16 52-1013-103 2x3 3.35 85.09 2.75 69.85 2.41 61.21 52-1013-104 2x4 4.10 104.14 3.50 88.90 3.16 80.25 52-1013-105 2x5 4.85 123.19 4.25 107.95 3.91 99.31 52-1013-106 2x6 5.60 142.24 5.00 127.00 4.66 118.36 Dimensions in inches (mm) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF15 Power Entry Modules Bolt-in Rear Terminals 60-BPR & BPS Series Features ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Solder lug and Fast-on tab terminals available Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF17) UL approved low leakage version also available Applications ■ ■ ■ ■ Circuit Diagram 1 CX E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY L1 CY 2 3 E 4 Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 60-XXX-010-3-2 60-XXX-010-3-4 60-XXX-010-5-2 250VAC 60-XXX-020-3-2 60-XXX-020-5-2 250VAC 60-XXX-030-3-2 60-XXX-030-3-4 250VAC 60-XXX-060-3-2 60-XXX-060-5-2 250VAC 60-XXX-100-5-2 60-BPR-150-3-11 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 6A 60-XXX-060-5-4 60-XXX-100-3-2 0.35mA 3A 60-XXX-030-5-4 60-XXX-060-3-4 Capacitance 2A 60-XXX-020-5-4 60-XXX-030-5-2 CY 1A 60-XXX-010-5-4 60-XXX-020-3-4 Leakage Current (Max.) 250VAC 10A 250VAC 15A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 Inductance (L1) Temperature Rise (Max.) 6.0mH 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C .022uF ± 20% 0.26mH 45°C .1uF ± 20% 0.15mH 45°C CX .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% * Substitute BPR or BPS for XXX BPS - Solder lug terminals BPR - Fast-on tab terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF16 Power Entry Modules Bolt-in Rear Terminals 60-BPR & BPS Series Temperature Characteristics 0.837 (21.3) 120 Current (%) 100 80 .944 (24) 60 1.967 (50) 20 30 40 50 60 70 Ambient Temperature (°C) 80 * General tolerance ± .012 (0.3) Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω Insertion Loss (dB) Insertion Loss (dB) 70 50 60-BPX-020-5-X 60-BPX-030-5-X 20 60-BPX-010-5-X 60 50 40 60-BPX-020-5-X 30 60-BPX-030-5-X 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 70 70 Insertion Loss (dB) 80 60-BPX-060-5-X 50 40 30 60-BPX-100-5-X 20 10 20 50 60-BPX-060-X-4 60 50 60-BPX-060-X-2 40 60-BPX-100-X-2 30 20 10 10 0 0.1 5 60-BPX-060;-100 60-BPX-060;-100 80 60 2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) 50Ω Level Meter 50Ω 80 60-BPX-010-5-X 30 50Ω 60-BPX-010;-020;-030 60-BPX-010;-020;-030 80 40 1.10 (28) 90 Common Mode 60 .157 (4) 1.181 (30) 1.573 (40) 20 70 1.476 (37.5) (2x) .142 (3.6) 40 0 2.263 (57.5) .252 (6.4) .846 (21.5) 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF17 Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards PCB mounting types available (see page PF46) Length under tab is shortened for small spaces Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF19) UL approved low leakage version also available Applications ■ ■ ■ ■ Circuit Diagram 1 CX E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY L1 CY 2 3 E 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BPF-010-3-2 60-BPF-010-3-4 60-BPF-010-5-2 250VAC 60-BPF-020-3-2 60-BPF-020-5-2 250VAC 60-BPF-030-3-2 60-BPF-030-5-2 250VAC 60-BPF-060-3-2 60-BPF-060-5-2 250VAC 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 3A 60-BPF-030-5-4 60-BPF-060-3-4 Capacitance 2A 60-BPF-020-5-4 60-BPF-030-3-4 CY 1A 60-BPF-010-5-4 60-BPF-020-3-4 Leakage Current (Max.) 6A 60-BPF-060-5-4 CX Inductance (L1) Temperature Rise (Max.) 6.0mH 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF18 Power Entry Modules Bolt-in Right Angle Terminals 60-BPF Series Temperature Characteristics 120 1.463 (37.2) 1.967 (50) 60-BPF Fast-on Terminals 1.317 (33.5) 1.573 (40) .885 (22.5) Current (%) 100 2- .142 (3.6) 80 .047 (1.2) .232 (5.9) 1.180 (30) 60 .024 (.6) .5 R4 .865 (22) 2- .142 (3.6) 1.573 (40) 40 .991 (25.2) .590 (15) * General tolerance ± .012 (.3) .142 .059 (3.6) (1.5) .031 (.8) 1.070 (27.2) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-BPF-010;-020 70 Insertion Loss (dB) Insertion Loss (dB) 80 60-BPF-010-3-X 60 50 60-BPF-020-3-X 40 30 20 10 0 0.1 60 60-BPF-010-X-4 50 40 30 60-BPF-020-X-4 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 70 70 Insertion Loss (dB) Insertion Loss (dB) 80 60-BPF-030-3-X 50 5 10 20 50 20 50 60-BPF-030;-060 60-BPF-030;-060 60 2 Frequency (MHz) 80 40 60-BPF-060-3-X 30 20 60 50 40 30 60-BPF-030-X-4 60-BPF-060-X-4 20 10 10 0 0.1 50Ω Level Meter 50Ω 60-BPF-010;-020 80 70 50Ω 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF19 Power Entry Modules High Frequency Attenuation 60-BHS Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 PCB mounting types available (see page PF48) PCB mounting minimizes space and provides economical installation Excellent filtering characteristics for high frequencies Earth coil standard Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF21) Applications ■ ■ ■ ■ Circuit Diagram 1 CX E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY L1 CY 2 3 E 4 L2 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BHS-010-3-11 60-BHS-010-3-4 60-BHS-010-5-11 250VAC 60-BHS-020-3-11 60-BHS-020-5-11 250VAC 60-BHS-030-3-11 60-BHS-030-5-11 250VAC 60-BHS-060-3-11 60-BHS-060-5-11 250VAC 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 3A 60-BHS-030-5-4 60-BHS-060-3-4 Capacitance 2A 60-BHS-020-5-4 60-BHS-030-3-4 CY 1A 60-BHS-010-5-4 60-BHS-020-3-4 Leakage Current (Max.) 6A 60-BHS-060-5-4 CX Inductance (L1) (L2) Temperature Rise (Max.) 0.1uF ± 20% .047uF ± 20% 0.1uF ± 20% 6mH 18.3uH 30°C 2.4mH 18.3uH 30°C 1.2mH 18.3uH 30°C .53mH 18.3uH 45°C .047uF ± 20% 0.1uF ± 20% .047uF ± 20% 0.1uF ± 20% .047uF ± 20% 0.1uF ± 20% .047uF ± 20% 0.1uF ± 20% .047uF ± 20% 0.1uF ± 20% .047uF ± 20% 0.1uF ± 20% .047uF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF20 Power Entry Modules High Frequency Attenuation 60-BHS Series .098 (2.5) 1.967 (50) 1.573 (40) Temperature Characteristics 120 .885 (22.5) Current (%) 100 1.180 (30) 60 .031 (.8) .5 R4 .865 (22) 40 2- .142 (3.6) 1.573 (40) .779 1.180 (19.8) (30) Panel cutout dimensions mounts from backside 20 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 Dimensions in inches (mm) 90 Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 60-BHS-XXX-X-11 80 90 60-BHS-020-X-11 60 50 40 60-BHS-030-X-11 30 60-BHS-060-X-11 20 50Ω 60-BHS-XXX-3-11 70 60-BHS-010-3-11 60 50 60-BHS-020-3-11 40 60-BHS-030-3-11 30 60-BHS-060-3-11 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 60-BHS-XXX-X-4 90 60-BHS-020-X-4 60 50 40 60-BHS-030-X-4 30 60-BHS-060-X-4 20 10 20 50 60-BHS-XXX-3-4 70 60-BHS-010-3-4 60 50 60-BHS-020-3-4 * 40 60-BHS-030-3-4 30 60-BHS-060-3-4 20 10 0 0.1 5 80 60-BHS-010-X-4 70 Insertion Loss (dB) Insertion Loss (dB) 80 2 Frequency (MHz) Frequency (MHz) 90 50Ω Level Meter 50Ω 80 60-BHS-010-X-11 70 Insertion Loss (dB) Insertion Loss (dB) 1.180 (30) 2- .142 (3.6) 80 90 1.534 (39) 1.389 (35.3) 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF21 Power Entry Modules Bolt-in Rear Terminals For General Purpose Applications 10-BPF Series Features ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25°C to +70°C Compact configuration Circuit Diagram CX CY Applications ■ ■ ■ ■ CY L1 1 Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CX CY L1 CX CY 2 CX CX L1 CY CY 3 Specifications Model Rated Rated Voltage Current (@ 50/60Hz) 10-BPF-001-5-A Leakage Current (Max.) 120/250VAC 1.5mH 0.50mA 6A 10-BPF-010-5-A 4700pF Temperature Rise (Max.) C A C 2 B A 0.5mH 1 3300pF & 0.01uF 1.5mH 2 B 3300pF 0.01uF 0.5mH 1 A 3300pF & 0.01uF 3300pF & 0.01uF 1.5mH 3 B 3300pF 3300pF & 0.01uF 10A 0.01uF Figure A 3.0mH 1 3A 10-BPF-006-5-D 10-BPF-010-5-D Inductance Circuit (L1) Diagram 3300pF 10-BPF-003-5-C 10-BPF-006-5-C CX 2200pF 10-BPF-003-5-A 10-BPF-006-5-A Capacitance 1A 10-BPF-001-5-C 10-BPF-003-5-D CY 30°C C Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF22 Power Entry Modules Bolt-in Rear Terminals For General Purpose Applications 10-BPF Series Figure B M3 (2X) 1.6 (40) M3 (2X) 2.0 (52) 2.0 (52) 1.1 (28.5) +.01 -0.0 1.6 (40) ±.007 Figure A 1.4 (37) 2.8 (72) 1.25 (32) Figure C .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 2.3 (62) 1.9 1.6 1.2 (50) (40) (30) .13 (3.5 (2X) 1.1 (28) .62 (16) .82 (21) .25 (6.5) 1.5 (37.5) 1.6 (40) 2.0 (51) 1.9 (50) Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 70 10-BPF-001-5-A 10-BPF-001-5-C 50 40 10-BPF-003-5-A 30 10-BPF-003-5-C 20 60 10-BPF-001-5-A 50 10-BPF-001-5-C 40 30 10-BPF-003-5-A 20 10-BPF-003-5-C 10 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 70 Insertion Loss (dB) Insertion Loss (dB) 50 10-BPF-006-5-A 10-BPF-006-5-C 40 30 20 10-BPF-010-5-A 10 0 0.1 0.5 1 20 50 2 10-BPF-006-5-D 60 50 40 30 10-BPF-010-5-A 1 10-BPF-010-5-D 10-BPF-006-5-A 20 10-BPF-006-5-C 10 10-BPF-010-5-D 0.2 10 80 10-BPF-006-5-D 70 5 10-BPF-006;-010 10-BPF-006;-010 80 2 Frequency (MHz) Frequency (MHz) 60 50Ω Level Meter 50Ω 80 Insertion Loss (dB) Insertion Loss (dB) 50Ω 10-BPF-001;-003 10-BPF-001;-003 80 0 0.1 .07 (2) Normal Mode 1 3 Filter 2 4 60 1.1 (27) Dimensions in inches (mm) Common Mode 70 1.8 (46) 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF23 Power Entry Modules Bolt-in Rear Terminals For Medical Purpose Applications 10-BPF Series Features ■ ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Operating temperature: -25°C to +70°C Compact configuration Low leakage current Circuit Diagram 1 Applications ■ ■ ■ ■ Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units E 3 L1 CX E 2 4 Specifications Model Rated Rated Voltage Current (@ 50/60Hz) 10-BPF-001-2-A 1A 10-BPF-003-2-A 120/250VAC 3A 10-BPF-006-2-A 6A Leakage Current (Max.) Capacitance CX Inductance (L1) Circuit Diagram Figure Temperature Rise (Max.) 1 A 30°C 3.0mH 5uA 0.01uF 1.5mH 0.5mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF24 Power Entry Modules Bolt-in Rear Terminals For Medical Purpose Applications 10-BPF Series M3 (2X) 1.1 (28.5) +.01 -0.0 1.6 (40) ±.007 .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 0.837 (21.3) 1.9 1.6 1.2 (50) (40) (30) Dimensions in inches (mm) 1.1 (28) 1.5 (37.5) .63 (16) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 70 70 10-BPF-001-2-A 50 10-BPF-003-2-A 40 30 20 10-BPF-006-2-A 10 0 0.1 0.2 0.5 1 2 50Ω 50Ω Level Meter 50Ω 10-BPF-001;-003;-006 80 Insertion Loss (dB) Insertion Loss (dB) 10-BPF-001;-003;-006 80 60 2.0 (51) .25 (6.5) .82 (21) 5 Frequency (MHz) 60 50 40 30 20 10-BPF-006-2-A 10-BPF-001-2-A 10 10 20 50 0 0.1 10-BPF-003-2-A 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF25 Power Entry Modules Snap-in with Wire Leads 60-SPL Series Features ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Wire output minimizes space and provides economical installation Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF27) Applications ■ ■ ■ ■ Circuit Diagram 1 CX E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units 3 CY L1 CY E 2 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-SPL-010-3-2 60-SPL-010-3-3 60-SPL-010-5-2 250VAC 60-SPL-020-3-2 60-SPL-020-5-2 250VAC 60-SPL-030-3-2 60-SPL-030-5-2 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.50mA 60-SPL-030-5-3 60-SPL-060-5-2 2200pF ± 20% 3A 60-SPL-060-3-2 60-SPL-060-3-3 0.35mA 0.35mA 250VAC 250VAC Capacitance 2A 60-SPL-020-5-3 60-SPL-030-3-3 CY 1A 60-SPL-010-5-3 60-SPL-020-3-3 Leakage Current (Max.) 2200pF ± 20% 3300pF ± 20% 2200pF ± 20% 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 6A 60-SPL-060-5-3 CX Inductance (L1) Temperature Rise (Max.) 6.0mH 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C 22nF ± 20% 33nF ± 20% 22nF ± 20% 33nF ± 20% 22nF ± 20% 33nF ± 20% 22nF ± 20% 33nF ± 20% .022uF ± 20% .033uF ± 20% 22nF ± 20% 33nF ± 20% 22nF ± 20% 33nF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF26 Power Entry Modules Snap-in with Wire Leads 60-SPL Series Temperature Characteristics 120 80 W T W .039 (1.0) 1.270 (32.3) .047 (1.2) 1.274 (32.4) .059 (1.5) 1.285 (32.5) T :Panel Thickness 1.612 (41) 4.719 (120)* .252 (6.4) 1.172 (29.8) Blue UL 1015 AWG #18 1.397 (35.5) 40 PVC Insulated wire 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 80 60-SPL-020-5-X 70 50Ω 50Ω Level Meter 50Ω 60-SPL-010;-020 60-SPL-010;-020 80 UL1617 AWG #22 Dimensions in inches (mm) Common Mode Insertion Loss (dB) 60-SPL-010-5-X 50 60-SPL-010-3-X 40 60-SPL-010-X-4 70 60-SPL-020-3-X 60 Green/Yellow Brown * Custom lengths available upon request. 0 Insertion Loss (dB) .236 (6) 60 20 30 20 60-SPL-010-X-2 60 50 60-SPL-020-X-4 40 30 60-SPL-020-X-2 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 80 60-SPL-030-5-X 70 Insertion Loss (dB) 50 40 60-SPL-060-5-X 30 60-SPL-060-3-X 20 60 0.2 0.5 1 20 50 60-SPL-030-X-2 50 40 60-SPL-060-X-4 30 20 60-SPL-060-X-2 10 10 0 0.1 10 60-SPL-030-X-4 70 60-SPL-030-3-X 60 5 60-SPL-030;-060 60-SPL-030;-060 80 2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) .853 (21.7) .838 (21.3) Panel cutout dimensions 100 Current (%) .963 (24.5) * General tolerance ± .012 (.3) R2 * Metal case Tin Plated 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF27 Power Entry Modules Bolt-in with Wire Leads 60-BPL Series Features Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal case filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Wire output for minimizing space use and economical installation Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF28) ■ ■ ■ ■ ■ ■ Circuit Diagram 1 Applications ■ ■ ■ ■ CX E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units 3 CY L1 CY E 2 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BPL-010-3-2 60-BPL-010-3-3 60-BPL-010-5-2 250VAC 60-BPL-020-3-2 60-BPL-020-3-3 250VAC 60-BPL-030-3-2 60-BPL-030-5-2 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.50mA 60-BPL-060-3-2 60-BPL-060-3-3 2200pF ± 20% 3A 60-BPL-030-5-3 60-BPL-060-5-2 0.35mA 0.35mA 250VAC 250VAC Capacitance 2A 60-BPL-020-5-3 60-BPL-030-3-3 CY 1A 60-BPL-010-5-3 60-BPL-020-5-2 Leakage Current (Max.) 2200pF ± 20% 3300pF ± 20% 2200pF ± 20% 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 6A 60-BPL-060-5-3 CX Inductance (L1) Temperature Rise (Max.) 6.0mH 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C 22nF ± 20% 33nF ± 20% 22nF ± 20% 33nF ± 20% 22nF ± 20% 33nF ± 20% 22nF ± 20% 33nF ± 20% .022uF ± 20% .033uF ± 20% 22nF ± 20% 33nF ± 20% 22nF ± 20% 33nF ± 20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF28 Power Entry Modules Bolt-in with Wire Leads 60-BPL Series Temperature Characteristics .5 R4 .865 (22) 120 1.180 (30) 1.573 (40) Current (%) 100 1.612 (41) .830 (21.1) 4.719 (120)* .252 (6.4) 1.967 (50) 1.172 (29.8) 20 30 40 50 60 70 Ambient Temperature (°C) 80 Oscillator 50Ω 90 1 3 Filter 2 4 Oscillator 50Ω 50Ω 80 60-BPL-020-5-X 60-BPL-010-3-X 30 20 Insertion Loss (dB) 60-BPL-010-5-X 40 60-BPL-010-X-4 70 60-BPL-020-3-X 50 60-BPL-010-X-2 60 50 60-BPL-020-X-4 40 30 60-BPL-020-X-2 20 10 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 80 60-BPL-030-5-X 70 Insertion Loss (dB) 50 40 60-BPL-060-5-X 30 60-BPL-060-3-X 20 60 0.5 1 20 50 60-BPL-030-X-2 50 40 60-BPL-060-X-2 30 20 60-BPL-060-X-4 10 10 0.2 10 60-BPL-030-X-4 70 60-BPL-030-3-X 60 5 60-BPL-030;-060 60-BPL-030;-060 80 2 Frequency (MHz) Frequency (MHz) 0 0.1 50Ω Level Meter 50Ω 60-BPL-010;-020 60-BPL-010;-020 0 0.1 * General tolerance ±.012 (0.3) Dimensions in inches (mm) 50Ω Level Meter 50Ω 60 BROWN Normal Mode 1 3 Filter 2 4 70 GREEN/YELLOW PVC Insulated wire UL1617 AWG #22 * Custom lengths available upon request. Common Mode 80 .236 (6) UL1015 AWG # 18 BLUE 1.160 (29.5) 1.573 (40) 0 Insertion Loss (dB) 1.573 (40) 60 40 1.239 (31.5) Panel cutout dimensions mounts from front side .944 (24) 2- .142 (3.6) 20 Insertion Loss (dB) 2- .118 (M3) 2- .130 (3.3) Panel cutout dimensions mounts from back side 80 .5 R3 .885 (22.5) .837 (21.3) 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF29 Power Entry Modules Bolt-in with Wire Leads 10-BPL Series Features Ideally suited for products that must conform to FCC part 15 regulations Metal case filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Wire output for minimizing space use and economical installation Operating temperature: -25°C to +70°C Compact configuration ■ ■ ■ ■ ■ ■ ■ Circuit Diagram Applications ■ ■ ■ ■ 1 E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units 3 CY L1 CX E CY 2 4 Specifications Model Rated Rated Leakage Voltage Current Current (@ 50/60Hz) (Max.) 10-BPL-006-5-B Capacitance CX 250VAC 3A Inductance Circuit Diagram (L1) Figure Temperature Rise (Max.) A 30°C 3.0mH 1A 10-BPL-001-5-B 10-BPL-003-5-B CY 0.50mA 6A 3300pF 0.01uF 1.5mH 1 0.5mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF30 Power Entry Modules Bolt-in with Wire Leads 10-BPL Series M3 (2X) Figure A 1.1 (28.5) +.01 -0.0 1.6 (40) .007 .80 (20.5) +.01 -0.0 1.4 (3.5) (2X) 1.9 1.6 1.2 (50) (40) (30) 1.1 (28) 1.5 (37.5) .63 (16) 4.72 (120±2) .25 (6.5) .82 (21) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 1 10-BPL-001;-003;-006 10-BPL-001-5-B 50 40 30 10-BPL-006-5-B 20 60 50 40 10-BPL-003-5-B 30 20 10-BPL-006-5-B 10 10 0 0.1 10-BPL-001-5-B 70 10-BPL-003-5-B Insertion Loss (dB) Insertion Loss (dB) 60 0.2 0.5 1 2 50Ω Level Meter 50Ω 10-BPL-001;-003;-006 80 80 70 50Ω 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF31 Power Entry Modules Snap-in Mount 60-SPR & SPS Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. Ideally suited for products that must conform to FCC part 15 regulations Metal cased miniature filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Snap-in style saves labor and hardware inventory Solder lug and fast-on tab terminations available Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF33) UL approved low leakage version also available Applications ■ ■ ■ ■ Circuit Diagram 1 CX E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units 3 CY L1 CY E 2 4 Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 60-XXX-010-3-2 60-XXX-010-3-4 60-XXX-010-5-2 250VAC 60-XXX-020-3-2 60-XXX-020-5-2 250VAC 60-XXX-030-3-2 60-XXX-030-5-2 250VAC 60-XXX-060-3-2 60-XXX-060-5-2 250VAC 60-XXX-100-5-2 60-SPR-150-3-11 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 0.50mA 3300pF ± 20% 0.35mA 2200pF ± 20% 6A 60-XXX-060-5-4 60-XXX-100-3-2 0.35mA Inductance (L1) Temperature Rise (Max.) 6.0mH 30°C 2.4mH 30°C 1.2mH 30°C 0.53mH 45°C 250VAC 10A .022uF ± 20% 0.26mH 45°C 250VAC 15A .1uF ± 20% 0.15mH 45°C Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 45g Input: Compatible with IEC-320 CX .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% 3A 60-XXX-030-5-4 60-XXX-060-3-4 Capacitance 2A 60-XXX-020-5-4 60-XXX-030-3-4 CY 1A 60-XXX-010-5-4 60-XXX-020-3-4 Leakage Current (Max.) .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% .022uF ± 20% .047uF ± 20% * Substitute SPR or SPS for XXX 60-SPR - Fast-on terminals 60-SPS - Solder lug terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF32 Power Entry Modules Snap-in Mount 60-SPR & SPS Series R2 Temperature Characteristics Current (%) 80 T: Panel Thickness T W .039 (1.0) 1.270 (32.3) .047 (1.2) 1.274 (32.4) .059 (1.5) 1.285 (32.5) 60 W Panel cutout dimensions for 1.0t chassis 2.033 (51.7) 1.805 (45.9) 1.418 (35.9) .252 (6.4) .157 (4) Solder Lug 2 X 3 hole * Standard terminal Fast-on tab #250 available as SPR series 2.096 (53.3) 40 1.395 (35.5) 20 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Oscillator 50Ω 50Ω Oscillator 50Ω 60-SPX-010;-020;-030 Insertion Loss (dB) 50 60-SPX-020-5-X 60-SPX-030-5-X 20 10 0 0.1 60 50 40 60-SPX-010-X-4 60-SPX-020-X-4 60-SPX-030-X-4 30 20 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 60-SPX-060;-100 70 70 Insertion Loss (dB) 80 60-SPX-60-5-X 50 2 5 10 20 50 60-SPX-060;-100 80 60 1 Frequency (MHz) Frequency (MHz) 40 30 60-SPX-100-5-X 20 10 0 0.1 50Ω Level Meter 50Ω 60-SPX-010;-020;-030 70 30 50Ω 80 60-SPX-010-5-X 40 Dimensions in inches (mm) 1 3 Filter 2 4 50Ω Level Meter 80 60 * General tolerance ± .012 (0.3) Normal Mode 1 3 Filter 2 4 70 1.172 (29.8) Solder lugs shown. Also available in fast-ons. Common Mode Insertion Loss (dB) .853 (21.7) Panel cutout dimensions 100 Insertion Loss (dB) .837 (21.3) .963 (24.5) 120 60-SPX-060-X-4 60 50 60-SPX-060-X-2 40 60-SPX-100-X-2 30 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF33 Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BFF/64-65-BFS Series Features ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. North American and Metric fuse holders available Fuse holder provides effective EMI suppression of common and differential mode Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Fast-on terminals or solder lug terminals Metal case provides effective EMI shielding Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF35) Applications ■ ■ ■ ■ ■ Circuit Diagram L L L1 E R CY E CX CY N N Computers and peripheral equipment Electronic equipment Digital equipment Measuring and testing instruments Telecommunications equipment Specifications Model* 64-XXX-020-3-11 64-XXX-020-5-11 64-XXX-020-3-12 64-XXX-020-5-12 64-XXX-040-3-11 64-XXX-040-5-11 64-XXX-040-3-12 64-XXX-040-5-12 64-XXX-060-3-11 64-XXX-060-5-11 64-XXX-060-3-12 64-XXX-060-5-12 65-XXX-020-3-11 65-XXX-020-5-11 65-XXX-020-3-12 65-XXX-020-5-12 65-XXX-040-3-11 65-XXX-040-5-11 65-XXX-040-3-12 65-XXX-040-5-12 65-XXX-060-3-11 65-XXX-060-5-11 65-XXX-060-3-12 65-XXX-060-5-12 Rated Voltage (@ 50/60Hz) 250VAC 250VAC 250VAC 125VAC 125VAC 125VAC Rated Current 2A 4A 6A 2A 4A 6A Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC F(S) = Fast-on or (Solder lug terminals) Leakage Current (Max.) 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.35mA 0.50mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA 0.20mA 0.25mA Capacitance CY 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF 2200pF 3300pF ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± ± 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% 20% Voltage Drop: 1V max. at rated current Weight: 78g Inlet: Compatible with IEC-320 CX Inductance (L1) Temperature Rise (Max.) 6.5mH 40°C 4.2mH 45°C 1.6mH 45°C 6.5mH 40°C 4.2mH 45°C 1.6mH 45°C 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF * Substitute BFF or BFS for XXX BFF - Fast-on terminals BFS - Solder lug terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF34 Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BFF/64-65-BFS Series Dimensions Temperature Characteristics 64/65-BFF Series 120 1.738 (44.2) 100 Current (%) 2.32 (59) .098 (2.5) 1.101 (28) Fuse cover 1.376 (35) 80 1.298 (33) 60 1.416±.008 (36±0.2) 40 1.29 (32.8) 2 - .13 +.008 -.004 (2 - 3.3+0.2 -0.1) Hole 0.252 (6.4) 1.14 (29) 1.616 (41.1) * Alternate Terminal for 64/65-BFS-Solder Lug Terminal Fast-on tab#250 t= .031 (0.8) 20 0.158 (4.0) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 2.249 (L:57.2) Common Mode Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 0.50 mA Leakage Versions 90 80 Insertion Loss (dB) Insertion Loss (dB) 60 50 40 6 Amp 30 0 0.1 0.2 0.5 60 50 6 Amp 40 4 Amp 30 10 1 2 5 Frequency (MHz) 10 20 0 0.1 50 0.35 mA Leakage Versions 90 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 10 20 50 0.35 mA Leakage Versions 80 80 70 70 Insertion Loss (dB) 2 Amp 60 50 40 6 Amp 30 2 Amp 60 50 40 30 6 Amp 4 Amp 20 20 4 Amp 10 0 0.1 2 Amp 20 4 Amp 10 50Ω Level Meter 50Ω 0.50 mA Leakage Versions 70 2 Amp 20 Insertion Loss (dB) 50Ω 80 70 90 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 90 * General Tolerance: ±.020 (0.5) * Metal Case 0.2 0.5 10 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF35 Fused Filtered Power Entry Modules For Medical or General Purpose Applications ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Medical equipment Electronic equipment Digital equipment Industrial equipment ■ ■ ■ Telecommunications equipment Measuring and testing instruments Personal computers and peripherals Circuit Diagrams 66/67-BFF(S)-XXX-0-X and 66/67-BFF(S)-XXX-4-X Filters 66/67-BFF(S)-XXX-1-X Filter L L L L L1 R E L1 CX E E R CX CY E LOAD ■ Applications LINE ■ Tested and found to be IAW VDE 0565 Part 3. Metric and North American fuse holders available Fuse holder provides effective EMI suppression of common and differential mode Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Fast-on terminations or solder lug terminations Metal case provides effective EMI shielding Provides susceptibility protection without the leakage current associated with line-to-ground capacitance Reduces the line to ground capacitance in order to meet patient care requirements Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF37) LOAD ■ LINE 66-67-BFF/66-67-BFS Series Features CY N N N N Specifications Model* 66-XXX-020-1-11 66-XXX-020-1-12 66-XXX-020-0-11 66-XXX-020-4-11 66-XXX-020-0-12 66-XXX-020-4-12 66-XXX-040-1-11 66-XXX-040-1-12 66-XXX-040-0-11 66-XXX-040-4-11 66-XXX-040-0-12 66-XXX-040-4-12 66-XXX-060-1-11 66-XXX-060-1-12 66-XXX-060-0-11 66-XXX-060-4-11 66-XXX-060-0-12 66-XXX-060-4-12 67-XXX-020-1-11 67-XXX-020-1-12 67-XXX-020-0-11 67-XXX-020-4-11 67-XXX-020-0-12 67-XXX-020-4-12 67-XXX-040-1-11 67-XXX-040-1-12 67-XXX-040-0-11 67-XXX-040-4-11 67-XXX-040-0-12 67-XXX-040-4-12 67-XXX-060-1-11 67-XXX-060-1-12 67-XXX-060-0-11 67-XXX-060-4-11 67-XXX-060-0-12 67-XXX-060-4-12 Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) 0.01mA 250VAC 2A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 4A 0.075mA 0.1mA 0.075mA 0.1mA 0.01mA 250VAC 6A 0.075mA 0.1mA 0.075mA 0.1mA 0.005mA 125VAC 2A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 4A 0.035mA 0.05mA 0.035mA 0.05mA 0.005mA 125VAC 6A Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC F(S) = Fast-on or (Solder lug terminals) 0.035mA 0.05mA 0.035mA 0.05mA Capacitance CY none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% none 330pF 470pF 330pF 470pF ± ± ± ± 20% 20% 20% 20% Voltage Drop: 1V max. at rated current Weight: 78g Inlet: Compatible with IEC-320 CX 0.1uF 0.22uF 0.1uF Inductance (L1) Temperature Rise (Max.) 6.5mH 40°C 2.4mH 45°C 1.6mH 45°C 6.5mH 40°C 2.4mH 45°C 1.6mH 45°C 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF 0.1uF 0.22uF * Substitute BFF or BFS for XXX BFF - Fast-on terminals BFS - Solder lug terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF36 Fused Filtered Power Entry Modules For Medical or General Purpose Applications 66-67-BFF/66-67-BFS Series Dimensions Temperature Characteristics 66-67-BFF/66-67-BFS Series 120 1.738 (44.2) Current (%) 2.32 (59) .098 (2.5) 1.101 (28) 100 Fuse cover 1.376 (35) 80 1.298 (33) 60 1.416±.008 (36±0.2) 40 1.29 (32.8) 2 - .13 +.008 -.004 (2 - 3.3+0.2 -0.1) Hole 0.252 (6.4) 1.14 (29) 1.616 (41.1) * Alternate Terminal for 66/67-BFS-Solder Lug Terminal Fast-on tab#250 t= .031 (0.8) 20 0 0.158 (4.0) 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 2.249 (L:57.2) Common Mode Oscillator 50Ω 90 80 70 70 Insertion Loss (dB) 80 60 2 Amp 40 30 0 0.1 90 0.2 0.5 1 2 5 Frequency (MHz) 10 20 60 30 90 80 70 70 60 2 Amp 40 30 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 6 Amp 0.2 20 50 1 2 5 Frequency (MHz) 10 20 50 60 2 Amp 50 40 30 0 0.1 6 Amp 4 Amp 10 10 0.5 0.075 and 0.1 mA Leakage Current 20 6 Amp 4 Amp 10 4 Amp 40 80 20 2 Amp 50 0 0.1 50 50Ω Level Meter 50Ω 0.01 mA Leakage Current 10 0.075 and 0.1 mA Leakage Current 50 50Ω 20 6 Amp 4 Amp 10 Insertion Loss (dB) Insertion Loss (dB) Oscillator 50Ω 0.01 mA Leakage Current 20 Insertion Loss (dB) 1 3 Filter 2 4 50Ω Level Meter 50Ω 50 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 90 * General Tolerance: ±.020 (0.5) * Metal Case 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF37 Switched and Fused Filtered Power Entry Modules For General Purpose Applications 64-65-BSF/64-65-SSF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3. North American and Metric fuse holders available Fuse holder and double pole power ON/OFF switch provided in a convenient/compact package Suitable for products that must conform to FCC and FTZ requirements Meets over voltage category II of IEC 664 and complies with IEC 950 Metal case provides effective EMI shielding Easy access fuse drawer with space for spare fuse Flange-mounted or snap-in styles available for quick mounting Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF39) Applications ■ ■ Computers and peripheral equipment Electronic equipment ■ ■ ■ Digital equipment Measuring and testing instruments Telecommunications equipment Circuit Diagram L CY E R CX CX L E CY N N Specifications Model* Rated Voltage (@ 50/60Hz) Rated Current 64-XXX-020-3-12 64-XXX-020-3-04 64-XXX-020-3-14 64-XXX-020-3-06 250VAC 2A 64-XXX-020-5-12 64-XXX-020-5-04 64-XXX-020-5-14 64-XXX-020-5-06 64-XXX-040-3-12 64-XXX-040-3-04 64-XXX-040-3-14 64-XXX-040-3-06 250VAC 4A 64-XXX-040-5-12 64-XXX-040-5-04 64-XXX-040-5-14 64-XXX-040-5-06 64-XXX-060-3-12 64-XXX-060-3-04 64-XXX-060-3-14 64-XXX-060-3-06 250VAC 6A 64-XXX-060-5-12 64-XXX-060-5-04 64-XXX-060-5-14 64-XXX-060-5-06 65-XXX-020-3-12 65-XXX-020-3-04 65-XXX-020-3-14 65-XXX-020-3-06 125VAC 2A 65-XXX-020-5-12 65-XXX-020-5-04 65-XXX-020-5-14 65-XXX-020-5-06 65-XXX-040-3-12 65-XXX-040-3-04 65-XXX-040-3-14 65-XXX-040-3-06 125VAC 4A 65-XXX-040-5-12 65-XXX-040-5-04 65-XXX-040-5-14 65-XXX-040-5-06 65-XXX-060-3-12 65-XXX-060-3-04 65-XXX-060-3-14 65-XXX-060-3-06 125VAC 6A 65-XXX-060-5-12 65-XXX-060-5-04 65-XXX-060-5-14 65-XXX-060-5-06 Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC B(S) = Bolt-in terminals or (Snap-in terminals) Leakage Current (Max.) CY 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.20mA 2200pF 0.25mA 3300pF 0.20mA 2200pF 0.25mA 3300pF 0.20mA 2200pF 0.25mA 3300pF Capacitance CX1 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF Voltage Drop: 1V max. at rated current Weight: 130g Inlet: Compatible with IEC-320 CX2 Inductance (L1) NONE 0.22uF NONE 10.5mH 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF * Substitute BSF or SSF for XXX BSF - Bolt-in switched and fused SSF - Snap-in switched and fused Temperature Rise (Max.) 45°C 45°C 45°C 45°C 45°C 45°C API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF38 Temperature Temperature Characteristics Characteristics 120 Current (%) 100 Switched and Fused Filtered Power Entry Modules For General Purpose Applications 80 60 40 20 0 30 40 50 60 70 Ambient Temperature (°C) 80 90 64/65-SSF Series Dimensions 64/65-BSF Series 1.947 (49.5) 1.101 (28) 20 1.313 (33.4) 1.101 (28) .248 (6.3) .248 (6.3) 1.133 (28.8) 1.514 (38.8) 1.526 (38.8) Fast-on tab #250 t= .031 (0.8) 2.556 (65) 2.556 (65) 2.340 (59.5) 2.348 (59.7) 2.348 (59.7) 2.340 (59.5) Ø.142 (3.6) 1.573 (40±0.2) R .079 (2.0) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 2 - .142 (3.6) Hole R .059 (1.5) Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) A t= .031 (0.8) Panel cutout dimension mount from back side 1.573 1.16±.334 0 (40.±0.2) (29.5± 0.5) 0 2.273 (57.8) Dimensions in inches (mm) Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) A 2.430 (61.8±0.1) 2.446 (62.2±0.1) 2.462 (62.6±0.1) 2.470 (62.8±0.1) 2.473 (62.9±0.1) 2.477 (63.0±0.1) * General Tolerance ± .039 (1.0) * Metal Case 2.399 (61) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω Oscillator 50Ω 0.35 mA Leakage Versions 100 80 90 70 80 2 Amp 60 Insertion Loss (dB) Insertion Loss (dB) 90 50Ω 1 3 Filter 2 4 50Ω Level Meter 50 40 4 Amp 30 6 Amp 20 90 0.2 1 0.5 2 5 Frequency (MHz) 10 20 60 50 2 Amp 40 4 Amp 6 Amp 0 0.1 50 0.50 mA Leakage Versions 100 80 0.5 1 2 5 Frequency (MHz) 10 20 50 20 50 64/65-B(S)SF-*-*-11(12,14) 80 Insertion Loss (dB) 2 Amp 60 50 40 4 Amp 30 6 Amp 20 70 60 4 Amp 6 Amp 50 2 Amp 40 30 10 0 0.1 0.2 90 70 Insertion Loss (dB) 70 20 0 0.1 50Ω Level Meter 50Ω 64/65-B(S)SF-*-*-02(04,06) 30 10 50Ω 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF39 Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications 66-67-BSF/66-67-SSF Series Features Tested and found to be IAW VDE 0565 Part 3 Metric and North American fuse holders available Fuse holder and a double pole power ON/OFF switch provides a convenient/compact package ■ Suitable for products that must conform to FCC and FTZ requirements ■ Meets over voltage category II of IEC 664 and complies with IEC 950 ■ Provides susceptibility protection without the leakage current associated with line-to-ground capacitors ■ Designed to meet requirements for non-patient and patient care equipment ■ Metal case provides effective EMI shielding ■ Easy access fuse drawer - space for spare fuse ■ Flange-mounted or snap-in styles available for quick mounting ■ Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF41) ■ ■ Applications ■ ■ ■ ■ Medical equipment Industrial equipment Telecommunications equipment Measuring and testing instruments ■ ■ Digital equipment (including switching power supplies) General purpose filter for susceptibility or high frequency “clean up” applications Circuit Diagram L L E L1 CX1 CX2 CY1 E LOAD R LINE Note: CY1 and CY2 capacitors omitted on 66/67 B(S)F-XXX-1-X Filters CY2 N N Specifications Model* 66-XXX-020-0-12 66-XXX-020-0-04 66-XXX-020-0-14 66-XXX-020-0-06 66-XXX-020-1-12 66-XXX-020-1-04 66-XXX-020-1-14 66-XXX-020-1-06 66-XXX-020-4-12 66-XXX-020-4-04 66-XXX-020-4-14 66-XXX-020-4-06 66-XXX-040-0-12 66-XXX-040-0-04 66-XXX-040-0-14 66-XXX-040-0-06 66-XXX-040-1-12 66-XXX-040-1-04 66-XXX-040-1-14 66-XXX-040-1-06 66-XXX-040-4-12 66-XXX-040-4-04 66-XXX-040-4-14 66-XXX-040-4-06 66-XXX-060-0-12 66-XXX-060-0-04 66-XXX-060-0-14 66-XXX-060-0-06 66-XXX-060-1-12 66-XXX-060-1-04 66-XXX-060-1-14 66-XXX-060-1-06 66-XXX-060-4-12 66-XXX-060-4-04 66-XXX-060-4-14 66-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 .075mA 330pF 2A .01mA NONE 0.1mA 470pF .075mA 330pF 250 VAC 4A .01mA NONE .01mA 470pF .075mA 330pF 6A .01mA NONE 0.1mA 470pF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF Temp. Induct. (L1) Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40°C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45°C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF Note: Test Voltage: 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC Voltage Drop: 1V max. at rated current Model* 67-XXX-020-0-12 67-XXX-020-0-04 67-XXX-020-0-14 67-XXX-020-0-06 67-XXX-020-1-12 67-XXX-020-1-04 67-XXX-020-1-14 67-XXX-020-1-06 67-XXX-020-4-12 67-XXX-020-4-04 67-XXX-020-4-14 67-XXX-020-4-06 67-XXX-040-0-12 67-XXX-040-0-04 67-XXX-040-0-14 67-XXX-040-0-06 67-XXX-040-1-12 67-XXX-040-1-04 67-XXX-040-1-14 67-XXX-040-1-06 67-XXX-040-4-12 67-XXX-040-4-04 67-XXX-040-4-14 67-XXX-040-4-06 67-XXX-060-0-12 67-XXX-060-0-04 67-XXX-060-0-14 67-XXX-060-0-06 67-XXX-060-1-12 67-XXX-060-1-04 67-XXX-060-1-14 67-XXX-060-1-06 67-XXX-060-4-12 67-XXX-060-4-04 67-XXX-060-4-14 67-XXX-060-4-06 Rated Rated Leakage Voltage Current Current Capacitance 50/60Hz (Max.) CY CX1 CX2 0.04mA 330pF 2A .005mA NONE 0.05mA 470pF 0.04mA 330pF 125 VAC 4A .005mA NONE 0.05mA 470pF 0.04mA 330pF 6A Weight: 130g Inlet: Compatible with IEC-320 B(S) = Bolt-in terminals or (Snap-in terminals) .005mA NONE 0.05mA 470pF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF 0.22uF 0.47uF Temp. Induct. (L1) Rise (Max.) NONE 0.22uF NONE 0.22uF NONE 0.22uF 10.5mH 40°C NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF NONE 0.22uF 4.2mH NONE 0.22uF NONE 0.22uF NONE 0.22uF 45°C NONE 0.22uF NONE 0.22uF NONE 0.22uF 1.6mH NONE 0.22uF NONE 0.22uF NONE 0.22uF * Substitute BSF or SSF for XXX BSF - Bolt-In Switched and Fused SSF - Snap-In Switched and Fused API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF40 Temperature Characteristics 120 Current (%) 100 Switched and Fused Filtered Power Entry Modules For Medical or General Purpose Applications 80 60 40 20 0 Dimensions 66/67-BSF Series 1.947 (49.5) 1.101 (28) 20 1.313 (33.4) 1.101 (28) 1.526 (38.8) 2.556 (65) .248 (6.3) 2.340 (59.5) Ø.142 (3.6) Fast-on tab #250 t= .031 (0.8) R .059 (1.5) Panel cutout dimension mount from back side Dimensions in inches (mm) 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 90 80 70 70 Insertion Loss (dB) 80 2 Amp 50 40 30 20 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 0.01 mA Leakage Current 60 2 Amp 50 40 30 4 Amp 6 Amp 0 0.1 50 0.075 and 0.1 mA Leakage Current 90 80 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 50Ω Level Meter 50Ω 10 10 90 50Ω 20 6 Amp 4 Amp A 2.430 (61.8±0.1) 2.446 (62.2±0.1) 2.462 (62.6±0.1) 2.470 (62.8±0.1) 2.473 (62.9±0.1) 2.477 (63.0±0.1) * General Tolerance ± .039 (1.0) * Metal Case Panel cutout dimension mount from back side 1.16 +.02 -0 (29.5 +0.5 -0 ) 0.01 mA Leakage Current 60 Thickness of Panel .031 (0.8t) .039 (1.0t) .047 (1.2t) .059 (1.5t) .071 (1.8t) .079 (2.0t) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 2.273 (57.8) A Common Mode Insertion Loss (dB) R .079 (2.0) t= .031 (0.8) 2.399 (61) 90 2.340 (59.5) 2.348 (59.7) 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 2 - .142 (3.6) Hole 1.573 1.16 +.02 -0 (40.±0.2) (29.5 +0.5) -0 90 1.133 (28.8) 1.514 (38.8) 2.556 (65) 1.573 (40±0.2) 80 66/67-SSF Series .248 (6.3) 2.348 (59.7) 30 40 50 60 70 Ambient Temperature (°C) 2 Amp 50 40 30 20 0 0.1 0.2 0.5 0.5 1 2 5 Frequency (MHz) 10 20 50 0.075 and 0.1 mA Leakage Current 2 Amp 60 50 40 4 Amp 30 6 Amp 20 6 Amp 4 Amp 10 0.2 10 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF41 Switched and Fused Filtered Power Entry Modules Dual Fuse for European Applications 68-BSF Series Features Dual fuse for European applications Fuse holder and double pole power ON/OFF switch provides a convenient/compact package ■ Suitable for products that must conform to FCC and FTZ requirements ■ Meets over voltage category II of IEC 664 and complies with IEC 950 ■ Metal case provides effective EMI shielding ■ IEC connector meets the safety standards of most certifying agencies ■ Easy access fuse drawer ■ Flange-mounted ■ UL, CSA, and SEMKO approved ■ Designed to be in accordance with VDE 0565, part 3 ■ Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF43) ■ ■ Circuit Diagram FUSE L L L1 E R1 CX2 CX1 L2 N CY1 E CY2 N SW Applications Computers and peripheral equipment Electronic equipment ■ Digital equipment ■ Measuring and testing instruments ■ Telecommunications equipment ■ ■ Specifications Model Rated Voltage (@ 50/60Hz) 68-BSF-020-3-01 68-BSF-040-3-04 68-BSF-060-3-01 68-BSF-060-3-04 Leakage Current (Max.) CY1 Capacitance CY2 CX1 2A 68-BSF-020-3-04 68-BSF-040-3-01 Rated Current 250VAC 4A 6A 0.35mA 2200pF 2200pF CX2 0.1uF 0.1uF 0.22uF 0.22uF 0.1uF 0.1uF 0.22uF 0.22uF 0.1uF 0.1uF 0.22uF 0.22uF Inductance (L1) Temperature Rise (Max.) 10.5mH 4.2mH 45°C 1.6mH Note: Test Voltage 1500VAC one minute, line to ground Insulation Resistance: 300 MΩ min. at 500VDC Voltage Drop: 1V max. at rated current Weight: 130g Inlet: Compatible with IEC-320 B(S) = Bolt-in terminals API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF42 Switched and Fused Filtered Power Entry Modules Dual Fuse for European Applications 68-BSF Series Temperature Characteristics 1.947 (49.5) 1.101 (28) .248 (6.3) 1.526 (38.8) 120 Current (%) 100 2.556 (65) 80 2.348 (59.7) 60 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 t= .031 (0.8) Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω R .059 (1.5) Panel cutout dimension mount from back side 2.399 (61) Common Mode 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 90 50Ω 50Ω Level Meter 50Ω 100 90 70 80 Insertion Loss (dB) 80 60 50 40 4 Amp 30 2 Amp 6 Amp 20 70 4 Amp 60 50 2 Amp 40 30 10 0 0.1 2 - .142 (3.6) Hole 1.573 1.16 +.02 -0 (40.±0.2) (29.5 +0.5) -0 0 1.133 (28.8) Fast-on Tab #250 2.273 (57.8) 1.573 (40±0.2) 40 20 Insertion Loss (dB) 2.340 (59.5) Ø.142 (3.6) 6 Amp 20 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF43 PCB Power Filters Miniature Printed Circuit Board 61-MPC Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ Miniature general purpose PCB mounted filter Requires minimal PCB real estate space Low cost Designed for two wire cord systems For three wire cord systems, Y capacitors can be attached externally Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF45) Applications ■ ■ ■ ■ ■ Circuit Diagram 3 1 Personal computers and peripherals Digital equipment Measuring instruments and medical equipment TV & VCR monitors and display units Home appliances L1 CX1 CX1 2 4 Specifications Model Rated Voltage (@ 50/60Hz) 61-MPC-010-1-11 61-MPC-016-1-11 61-MPC-025-1-11 61-MPC-036-1-11 Rated Current Leakage Current (Max.) CX1 Capacitance CX2 1A 250VAC 1.6A 2.5A 3.6A Inductance (L1) Temperature Rise (Max.) 11mH 0.1mA 0.1uF 0.1uF 6.0mH 2.4mH 40°C 1.2mH Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 17.5g API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF44 PCB Power Filters Miniature Printed Circuit Board 61-MPC Series 4 3 4 — .031 (.8) .551 (14) 2 1 .767 (19.5) .059 (1.5) 1.239 (31.5) .767 (19.5) .590 (15) .354 (9) Dimensions in inches (mm) Temperature Characteristics Common Mode 1 3 Filter 2 4 Oscillator 50Ω 100 50Ω Level Meter 50Ω 1 3 Filter 2 4 (Test circuit 2) Oscillator 50Ω Current (%) Common mode with Y cap. (Test circuit 1) 120 50Ω Level Meter 50Ω 80 60 40 20 0 0 30 40 50 60 70 80 Ambient Temperature (°C) 90 100 61-MPC 80 Insertion Loss (dB) 70 Y Cap 2 X 3300pF 61-MPC-010-1-11 60 Normal Mode 50 40 30 61-MPC-025-1-11 20 0 0.1 Oscillator 50Ω 61-MPC-036-1-11 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50Ω Level Meter 50Ω 61-MPC 61-MPC 80 70 70 61-MPC-010-1-11 60 Insertion Loss (dB) Insertion Loss (dB) 50Ω 50 80 50 40 30 61-MPC-016-1-11 20 61-MPC-025-1-11 10 0 0.1 1 3 Filter 2 4 (Test circuit 3) 61-MPC-016-1-11 0.5 1 50 61-MPC-010-1-11 40 61-MPC-016-1-11 30 61-MPC-025-1-11 20 61-MPC-036-1-11 10 61-MPC-036-1-11 0.2 60 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF45 Power Entry Modules Bolt-in Right Angle Terminals for PCB Applications 60-BPP Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal case offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Uses IEC connector that meets most safety standards Solder lug, Fast-on tab styles available (see page PF18) PCB mounting style minimizes space and provides economical installation Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF47) UL approved low leakage version also available ■ ■ ■ 1 Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY L1 CX E Applications ■ Circuit Diagram CY 2 3 E 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BPP-010-3-2 60-BPP-010-3-4 60-BPP-010-5-4 60-BPP-020-3-2 60-BPP-020-3-4 60-BPP-030-3-4 60-BPP-030-5-2 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 3A 0.50mA 60-BPP-060-3-2 60-BPP-060-5-2 0.35mA 250VAC 60-BPP-030-5-4 60-BPP-060-3-4 Capacitance 2A 60-BPP-020-5-2 60-BPP-030-3-2 CY 1A 60-BPP-010-5-2 60-BPP-020-5-4 Leakage Current (Max.) 0.35mA 3300pF 2200pF 6A 60-BPP-060-5-4 0.50mA 3300pF CX Inductance (L1) Temperature Rise (Max.) 0.022uF 0.047uF 0.022uF 6.0mH 0.047uF 0.022uF 0.047uF 0.022uF 2.4mH 30°C 0.047uF 0.022uF 0.047uF 0.022uF 1.2mH 0.047uF 0.022uF 0.047uF 0.022uF 0.53mH 45°C 0.047uF Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF46 Power Entry Modules Bolt-in Right Angle Terminals for PCB Applications 60-BPP Series Temperature Characteristics 120 100 Current (%) .098 (2.5) 60-BPP PCB Mounting Type 1.463 (37.2) 1.967 (50) 1.317 (33.5) 1.573 (40) .885 (22.5) 2- .142 (3.6) 80 .024 (.6) .5 R4 .865 (22) 40 2- .142 (3.6) 1.573 (40) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 .142 .059 (3.6) (1.5) .031 (.8) 1.070 (27.2) .779 1.180 (19.8) (30) .708 (18) Dimensions in inches (mm) 90 Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 70 50Ω Level Meter 50Ω 80 70 Insertion Loss (dB) 60-BPP-010-3-X 60 50Ω 60-BPP-010;-020 60-BPP-010;-020 80 Insertion Loss (dB) * General tolerance ± .012 (.3) Panel cutout dimensions mounts from backside 20 50 60-BPP-020-3-X 40 30 20 60 60-BPP-010-X-4 50 40 30 60-BPP-020-X-4 20 10 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 60-BPP-030;-060 70 70 Insertion Loss (dB) 80 60-BPP-030-3-X 50 40 60-BPP-060-3-X 30 20 10 0 0.1 5 10 20 50 20 50 60-BPP-030;-060 80 60 2 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) .047 (1.2) .232 (5.9) 1.180 (30) 60 .991 (25.2) .590 (15) 60 50 40 30 60-BPP-030-X-4 60-BPP-060-X-4 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF47 Power Entry Modules High Frequency Attenuation Bolt-in for PCB Applications 60-BHP Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ ■ Ideally suited for products that must conform to FCC part 15 regulations Metal cased filter offers high performance Meets over voltage of IEC 664 category II and complies with IEC 950 Solder lug, Fast-on tab styles available (see page PF20) PCB mounting minimizes space and provides economical installation Excellent filtering characteristics for high frequencies Earth coil standard Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF49) Circuit Diagram 1 Applications ■ ■ ■ ■ CX E Digital equipment Personal computers and peripherals Measuring instruments Monitor and display units CY L1 CY 2 3 E 4 L2 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 60-BHP-010-3-11 0.35mA 60-BHP-010-3-4 0.50mA 60-BHP-010-5-4 60-BHP-020-3-11 60-BHP-020-3-4 60-BHP-030-3-4 60-BHP-030-5-11 60-BHP-060-5-4 3300pF±20% 0.35mA 2200pF±20% 0.50mA 3300pF±20% 0.35mA 2200pF±20% 3A 60-BHP-060-3-11 60-BHP-060-5-11 2200pF±20% 250VAC 60-BHP-030-5-4 60-BHP-060-3-4 Capacitance 2A 60-BHP-020-5-11 60-BHP-030-3-11 CY 1A 60-BHP-010-5-11 60-BHP-020-5-4 Leakage Current (Max.) 0.50mA 3300pF±20% 0.35mA 2200pF±20% 0.50mA 3300pF±20% 6A CX Inductance (L1) (L2) Temperature Rise (Max.) 0.1uF±20% .047uF±20% 0.1uF±20% 6mH .047uF±20% 0.1uF±20% .047uF±20% 0.1uF±20% 2.4mH .047uF±20% 18.3 uH 0.1uF±20% .047uF±20% 0.1uF±20% 30°C 1.2mH .047uF±20% 0.1uF±20% .047uF±20% 0.1uF±20% 0.53mH 45°C .047uF±20% Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 50g Input: Compatible with IEC-320 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF48 Power Entry Modules High Frequency Attenuation Bolt-in for PCB Applications 60-BHP Series 60-BHP PCB Mounting Type Temperature Characteristics 120 Current (%) 100 .098 (2.5) 1.967 (50) 1.573 (40) .885 (22.5) 80 5 4. R 2- .142 (3.6) .059 (1.5) .031 (.8) 1.070 (27.2) .024 (.6) 1.573 (40) 40 .142 (3.6) .047 (1.2) .232 (5.9) 1.180 (30) .865 (22) .991 (25.2) .590 (15) 2- .142 (3.6) 60 1.534 (39) 1.389 (35.3) .779 1.180 (19.8) (30) .708 (18) Panel cutout dimensions mounts from backside 20 Dimensions in inches (mm) 0 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω Oscillator 50Ω 60-BHP-XXX-X-11 80 Insertion Loss (dB) 50Ω 90 60-BHP-020-X-11 60 50 40 60-BHP-030-X-11 30 60-BHP-060-X-11 20 50Ω 60-BHP-XXX-3-11 70 60-BHP-010-3-11 60 50 60-BHP-020-3-11 40 60-BHP-030-3-11 30 60-BHP-060-3-11 20 10 10 0 0.1 0.2 1 0.5 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 60-BHP-XXX-X-4 Insertion Loss (dB) 80 90 60-BHP-020-X-4 60 50 40 60-BHP-030-X-4 30 60-BHP-060-X-4 20 10 20 50 60-BHP-XXX-3-4 70 60-BHP-010-3-4 60 50 60-BHP-020-3-4 40 60-BHP-030-3-4 30 60-BHP-060-3-4 20 10 10 0 0.1 5 80 60-BHP-010-X-4 70 2 Frequency (MHz) Insertion Loss (dB) 90 50Ω Level Meter 50Ω 80 60-BHP-010-X-11 70 Insertion Loss (dB) 90 1 3 Filter 2 4 50Ω Level Meter 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF49 Power Line Filters Appliance Filters 11-MPC Series Features ■ ■ ■ ■ ■ Miniature general purpose PCB mounted filter Requires minimal PCB real estate space Low cost Operating temperature: -25°C to +70°C Two forms of cases are available: metal case and plastic case Circuit Diagram Circuit 1 Applications ■ ■ ■ ■ ■ Personal computers and peripherals Digital equipment Measuring instruments and medical equipment TV & VCR monitors and display units Home appliances Circuit 2 Circuit 3 Circuit 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 11-MPC-001-2-B Leakage Current (Max.) Circuit Diagram Figure 5uA 1 A1 1A 11-MPC-001-5-A A 2 11-MPC-001-5-B 11-MPC-002-5-B 11-MPC-002-5-D 11-MPC-003-5-E 11-MPC-006-5-B 11-MPC-006-5-C 11-MPC-016-5-B 120/250VAC 2A 0.50mA 3A 6A 16A Temperature Rise (Max.) 3 2 0.2mA 4 A1 D 30°C E A1 C B Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 17.5g API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF50 PCB Power Filters Miniature Printed Circuit Board 11-MPC Series Figure A Figure A1 Figure B 0.6 0.9 (16) (25) 2.0 0.9 (25)±.007 (51) 0.6 (16) 0.9 (25) 10.0± 0.2 0.6 (15) 0.4 (10) 20.0±1.0 0.9 (25) 2.5 (64) Figure C Figure D 35.0 10.0 .60 (15) ±.07 .79 (20) 1.1 (29) 1.7 (44) 28.0 16.0 45.0 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 80 11-MPC-001-2-B 50 40 11-MPC-002-5-D 30 20 11-MPC-002-5-B 10 0.2 0.5 1 60 11-MPC-001-5-B 50 11-MPC-001-2-B 40 30 20 11-MPC-001-5-A 10 2 5 10 20 0 0.1 50 11-MPC-002-5-B 0.2 0.5 1 11-MPC-003;-006;-016 Insertion Loss (dB) Insertion Loss (dB) 11-MPC-006-5-B 11-MPC-016-5-B 20 10 1 60 50 0.5 1 2 50 40 11-MPC-016-5-B 11-MPC-003-5-E 30 11-MPC-006-5-C 20 11-MPC-006-5-B 10 0.2 20 70 11-MPC-003-5-E 0 0.1 10 80 11-MPC-006-5-C 30 5 11-MPC-003;-006;-016 80 40 2 Frequency (MHz) Frequency (MHz) 70 50Ω Level Meter 50Ω 11-MPC-002-5-D 70 11-MPC-001-5-A Insertion Loss (dB) 60 50Ω 11-MPC-001;-002 11-MPC-001;-002 11-MPC-001-5-B 7.0 Dimensions in inches (mm) 80 70 1.4 (35.5) 1.9 (49) Normal Mode 1 3 Filter 2 4 Insertion Loss (dB) 45.0 36.0 Common Mode 50 .15 (4) .45 (11.5) 1.4 (35) .45 (11.5) 10.0 1.9 (30) .30 (7.5) 60 1.1 (27) 01 (5X) .30 (7.5) 0 0.1 0.6 (15) ±.03 Figure E 05.0 .03 (1) (5X) 1.4 (36) 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF51 Power Line Filters Appliance Filters 62-AL/62-AC Series Features ■ ■ ■ ■ ■ ■ ■ Tested and found to be IAW VDE 0565 Part 3 Low-cost plastic case Compact design requires minimal real estate space Suitable for products that must conform to FCC regulations Wide variety of circuit and filtering options Good filtering characteristics for both normal mode and common mode Epoxy molded for reliability Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF53) Fast-on tab #110 .629 (16.0) 1.220 (31.0) 1.573 (40.0) .177 x .138 (4.5 x 3.5) .371 (9.4) .994 (24.0) .371 (9.4) 1.527 (38.8) .657 (16.7) .374 (9.5) .263 (6.7) Dimensions in inches (mm) Applications Circuit Diagrams Personal computers and peripherals ■ Digital equipment ■ Industrial equipment ■ Vending machines ■ Home appliances ■ Office equipment ■ 62-AFL-010-3-11 62-AFC-010-3-11 62-AFL-010-5-11 62-AFC-010-5-11 62-AFL-016-3-11 62-AFC-016-3-11 62-AFL-016-5-11 62-AFC-016-5-11 62-AFL-030-3-11 62-AFC-030-3-11 62-AFL-030-5-11 62-AFC-030-5-11 62-AFL-045-3-11 62-AFC-045-3-11 62-AFL-045-5-11 62-AFC-045-5-11 62-AFL-060-3-11 62-AFC-060-3-11 62-AFL-060-5-11 62-AFC-060-5-11 Rated Voltage (@ 50/60Hz) R CY1 CY2 CX CY1 CY2 * R= w/ Bleeder Resistor F = w/o Bleeder Resistor Rated Current 1.0A 1.6A 250VAC CX R L 62-A*C Series Specifications Model* L 62-A*L Series Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 4.5A Inductance (L1) Temperature Rise (Max.) 11.0mH 6.0mH 0.1uF 3.0A 6.0A CX 2.4mH 40°C 1.0mH Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. 0.53mH * Available with bleeder resistor Replace F with R for part number API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF52 Temperature Characteristics 120 100 Current (%) Power Line Filters Appliance Filters 80 60 40 20 0 Normal 20 Mode 30 40 50 60 70 Ambient Temperature (°C) 62-AL/62-AC Series Common Mode Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 80 62-AFL-030-3-11 Insertion Loss (dB) Insertion Loss (dB) 62-AFL-010-3-11 50 40 30 20 62-AFL-060-3-11 10 0.5 1 2 10 5 20 60 62-AFL-010-3-11 40 30 62-AFL-030-3-11 20 62-AFL-060-3-11 0 0.1 50 0.2 80 62-AFC-030-3-11 Insertion Loss (dB) 62-AFC-010-3-11 50 40 30 20 62-AFC-060-3-11 10 0.2 0.5 1 2 10 5 20 30 62-AFC-045-3-11 62-AFC-060-3-11 20 0.2 0.5 1 70 40 30 62-AFL-045-5-11 20 62-AFL-060-5-11 10 1 2 5 10 20 62-AFL-016-5-11 60 50 20 50 62-AFL-030-5-11 50 40 30 20 62-AFL-060-5-11 10 0 0.1 50 62-AFL-045-5-11 0.2 0.5 1 2 5 10 Frequency (MHz) 62-AFC-xxx-5-11 62-AFC-xxx-5-11 80 80 70 70 62-AFC-010-5-11 Insertion Loss (dB) Insertion Loss (dB) 20 62-AFL-010-5-11 Frequency (MHz) 60 10 62-AFL-xxx-5-11 50 0.5 5 80 62-AFL-016-5-11 62-AFL-010-5-11 0.2 2 Frequency (MHz) 62-AFL-030-5-11 0 0.1 50 62-AFC-010-3-11 40 0 0.1 50 Insertion Loss (dB) Insertion Loss (dB) 60 20 62-AFC-016-3-11 50 62-AFL-xxx-5-11 70 10 60 Frequency (MHz) 80 5 10 62-AFC-045-3-11 0 0.1 2 62-AFC-030-3-11 70 62-AFC-016-3-11 60 1 62-AFC-XXX-3-11 62-AFC-XXX-3-11 80 70 0.5 Frequency (MHz) Frequency (MHz) Insertion Loss (dB) 62-AFL-016-3-11 50 10 62-AFL-045-3-11 0.2 50Ω Level Meter 50Ω 62-AFL-045-3-11 70 62-AFL-016-3-11 0 0.1 50Ω 62-AFL-XXX-3-11 62-AFL-xxx-3-11 80 60 90 Normal Mode 1 3 Filter 2 4 70 80 50 40 30 62-AFC-060-5-11 20 62-AFC-045-5-11 62-AFC-030-5-11 62-AFC-016-5-11 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 60 50 62-AFC-016-5-11 62-AFC-030-5-11 62-AFC-010-5-11 40 30 20 62-AFC-045-5-11 10 50 0 0.1 62-AFC-060-5-11 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF53 Power Line Filters Single Stage 62-PPF/PQF/PRF Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ Low-cost plastic case Compact design requires minimal real estate space Suitable for products that must conform to FCC and FTZ regulations Wide variety of circuit and filtering options Good filtering characteristics for both normal mode and common mode Epoxy molded for reliability Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF55) ■ ■ ■ ■ Personal computers and peripherals Digital equipment Industrial equipment Vending machines Office equipment 62-PQF-020-5-11 62-PQF-020-5-12 62-PPF-020-5-11 62-PPF-020-5-12 62-PQF-030-5-11 62-PQF-030-5-12 62-PPF-030-5-11 62-PPF-030-5-12 62-PQF-060-5-11 62-PQF-060-5-12 62-PPF-060-5-11 62-PPF-060-5-12 62-PRF-010-5-11 62-PRF-010-5-12 62-PRF-020-5-11 62-PRF-020-5-12 62-PRF-030-5-11 62-PRF-030-5-12 Rated Voltage (@ 50/60Hz) CX R CY CX R L1 L1 62-PRF* Series CY CY L1 CY R CX CY CY * Bleeder Resistor is available only for 62-P(Q/R/P)F-XXX-X-12 Specifications Model L1 62-PQF* Series 62-PPF* Series Applications ■ Circuit Diagrams Rated Current Leakage Current (Max.) CY Capacitance 2A 3A 0.50mA 250VAC 3300pF 6A 1A 2A 3A CX 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF 0.1uF .22uF Inductance (L1) Temperature Rise (Max.) 15mH 8mH 30°C 2.1mH 486uH 181uH 97uH Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. (except 62-PRF-010-5-11) at rated current 62-PRF-010-5-11: 1.5V max. at rated current Weight: 62-PPF & PQF Series: 2.11 ounces (60 grams) 62-PRF Series: 1.76 ounces (50 grams) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF54 Power Line Filters Single Stage 62-PPF/PQF/PRF Series Temperature Characteristics Normal Mode 120 1 3 Filter 2 4 Current (%) 100 Oscillator 50Ω 80 50Ω 60 40 80 20 20 30 40 50 60 70 Ambient Temperature (°C) 80 90 Insertion Loss (dB) 70 0 Fast-on tab #110 60 62-PQF Series 62-PQF-020-5-12 50 40 62-PQF-020-5-11 30 62-PQF-060-5-12 20 62-PQF-060-5-11 10 0 0.1 .786 (20) 0.2 1 0.5 .177 x .138 (4.5 x 3.5) 1.947 (49.5) 2.006 (51) .354 (9) 80 1.265 (32) .590 (15) Dimensions in inches (mm) Also available with .250 Fast-ons Common Mode Oscillator 50Ω 50Ω Insertion Loss (dB) 40 0 0.1 62-P(Q/P)-020-5-11 62-P(Q/P)-030-5-11 0.2 0.5 1 10 20 50 10 20 50 62-PPF-020-5-12 40 62-PPF-020-5-11 30 62-PPF-060-5-12 20 62-PPF-060-5-11 2 0.2 1 0.5 2 5 62-PRF Series 70 50 10 50 80 60 20 50 Frequency (MHz) 62-P(Q/P)-060-5-11 30 20 60 0 0.1 50Ω Level Meter 62-P(P/Q/R)F Series 70 10 62-PPF Series 10 1 3 Filter 2 4 80 5 70 .904 (23) Insertion Loss (dB) .354 (9) 2 Frequency (MHz) 1.573 (40) Insertion Loss (dB) 50Ω Level Meter 50Ω 60 50 62-PRF-010-5-11 40 62-PRF-010-5-12 30 62-PRF-030-5-12 20 62-PRF-030-5-11 10 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF55 Power Line Filters Single Stage Wire Leads 62-PML Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ Compact design requires minimal real estate space Suitable for products that must conform to FCC and FTZ regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Structure provides effective shielding for noise generated externally and internally Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF57) Circuit Diagram 1 CY L1 R CX CX E Applications ■ ■ ■ ■ ■ Digital equipment Personal computers and peripherals Measuring instruments Medical equipment Factory automation equipment 3 CY 4 2 Specifications Model Rated Voltage (@ 50/60Hz) 62-PML-015-3-11 1.5A 62-PML-015-5-11 62-PML-030-3-11 62-PML-030-5-11 62-PML-050-3-11 62-PML-050-5-11 Rated Current 250VAC 3A 5A Leakage Current (Max.) CY Capacitance 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF 0.35mA 2200pF 0.50mA 3300pF CX Inductance (L1) Temperature Rise (Max.) 10.0mH 0.1uF 4.3mH 30°C 2.4mH Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Weight: 62-PML-015 Series: 3.06 ounces (87 grams) 62-PML-030 Series: 3.17 ounces (90 grams) 62-PML-050 Series: 3.28 ounces (93 grams) Discharge time: 0.4 sec. max. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF56 Power Line Filters Single Stage Wire Leads 62-PML Series BK Temperature Characteristics WH G/Y 120 BK 1.219 (31) .786 (20) 1.966 (50) WH 100 Current (%) 1.573 (40) PVC Insulated wire AWG # 20 UL1015 .629 (16) 2 — .138 x .181 (3.5 x 4.6) .944 (24) 80 60 .395 (10) .395 (10) 5.112* (130) 40 5.112* (130) 20 * Custom lengths available upon request. Dimensions in inches (mm) 0 20 30 40 50 60 70 80 1.856 (47.2) 90 Ambient Temperature (°C) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω Insertion Loss (dB) 50Ω Oscillator 50Ω 62-PML 60 90 62-PML-015-5-21 40 30 62-PML-050-5-21 20 10 0 0.1 0.5 1 2 5 Frequency (MHz) 50Ω Level Meter 50Ω 62-PML 70 60 62-PML-050-5-11 50 40 62-PML-030-5-11 30 62-PML-015-5-11 20 0.2 50Ω 80 62-PML-030-5-21 50 Insertion Loss (dB) 80 70 1 3 Filter 2 4 50Ω Level Meter 10 20 50 10 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF57 Power Line Filters Single Stage Wire Leads for Medical Purpose Applications 12-PML & 12-PMF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Compact design requires minimal real estate space Suitable for products that must conform to FCC and FTZ regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Structure provides effective shielding for noise generated externally and internally Operating temperature: -25°C to +70°C Low leakage current Circuit Diagram Circuit 1 Circuit 2 Applications ■ ■ ■ ■ ■ Digital equipment Personal computers and peripherals Measuring instruments Medical equipment Factory automation equipment Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 12-PML-001-2-A 1A 12-PML-002-2-A 2A 12-PML-006-2-A 6A 12-PML-010-2-A 12-PMF-001-2-B 120/250VAC 10A 1A 12-PMF-002-2-B 2A 12-PMF-006-2-B 6A 12-PML-001-2-C 1A Leakage Current (Max.) Circuit Diagram Figure 1 A 5uA Temperature Rise (Max.) 30°C 2 B 1 C Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Discharge time: 0.4 sec. max. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF58 Power Line Filters Single Stage Wire Leads for Medical Purpose Applications 12-PML & 12-PMF Series Figure A Figure C .31 (8) .13 (3.5) X .17 (4.5) SLOT (2 PLACES) .13 (3.5) X .17 (4.5) SLOT (2 PLACES) .94 (24) 1.5 (39) 1.9 (49) 1.2 (30) 1.25 (32) 1.6 (42) 1.9 (48) 1.7 (44) .78 (20) .78 (20) Figure B .14 (3.8) (2X) 1.2 (30) 1.7 (44) .79 (20) 2.2 (56) 2.4 (61) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 80 70 70 60 50 12-PML-001-2-A 12-PML-006-2-A 40 30 20 10 12-PML-002-2-A 0 0.1 0.5 1 2 60 12-PML-002-2-A 12-PML-006-2-A 12-PML-001-2-A 50 40 30 20 12-PML-010-2-A 10 12-PML-010-2-A 0.2 5 10 20 0 0.1 50 0.2 0.5 1 2 Frequency (MHz) 70 70 12-PMF-001-2-B 12-PMF-002-2-B 40 30 20 12-PMF-006-2-B 10 0 0.1 0.5 1 2 5 Frequency (MHz) 10 60 12-PMF-001-2-B 20 50 20 50 12-PMF-002-2-B 1 50 11-PML-001-2-C 40 30 1 20 12-PMF-006-2-B 10 11-PML-001-2-C 0.2 10 12-PMF-001;-002;-006;-010 80 Insertion Loss (dB) Insertion Loss (dB) 12-PMF-001;-002;-006;-010 50 5 Frequency (MHz) 80 60 50Ω Level Meter 50Ω 12-PML-001;-002;-006;-010 80 Insertion Loss (dB) Insertion Loss (dB) 12-PML-001;-002;-006;-010 50Ω 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF59 Power Line Filters Single Stage 62-LMF & LMB Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ Space saving, compact designs Suitable for products that must conform to FCC and FTZ regulations Excellent filtering characteristics for both normal mode and common mode Structure provides effective shielding for noise generated externally and internally Metal case provides effective shielding Rugged construction Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF61) Circuit Diagram 1 R ■ ■ ■ CY Digital equipment Office automation equipment, such as copy and fax machines Computers and peripherals Instrumentation and controls 3 CX CX Applications ■ CY L1 E 4 2 Specifications Model* Rated Voltage (@ 50/60Hz) 62-LMB-030-5-11 62-LMF-030-5-11 62-LMB-050-5-11 62-LMF-050-5-11 62-LMB-080-5-11 62-LMF-080-5-11 62-LMB-100-5-11 62-LMF-100-5-11 Rated Current CX Inductance (L1) 3A 0.1uF 14mH 5A 0.1uF & .22uF 7.0mH 8A .22uF 4.2mH 10A .33uF 2.2mH 250VAC Leakage Current (Max.) 0.50mA Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. at rated current Discharge time: 0.4 sec. max. Weight: 5.3 ounces (150 grams) CY Capacitance Temperature Rise (Max.) 45°C 3300pF *62-LMF - designates Fast-on terminals 62-LMB - designates Bolt-in terminals 62-LML - wire lead in/outputs also available API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF60 Temperature Characteristics 120 100 Current (%) Power Line Filters Single Stage 80 60 40 20 62-LMF & LMB Series 0 30 40 50 60 70 Ambient Temperature (°C) 80 90 62-LMF 62-LMB .708 (18.0) 20 1.10 (28.0) 1.97 (50.0) .66 (16.8) .66 (16.8) .255 (6.5) .61 (15.5) 1.10 (28.0) .708 (18.0) .61 (15.5) 1.97 (50.0) 2 - ø4.8 .255 (6.5) 5-M4 2.39 (60.7± 0.5) 1.22 (31.0) 1.97 (50.0) 2.39 (60.7± 0.5) 1.22 (31.0) 2.79 (70.9) .61 (15.5) 1.97 (50.0) 2.79 (70.9) .61 (15.5) Fast-on Tabs #250 .031 (0.8) t 2 - ø .188 (4.8) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 90 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 62-LMF & LMB 90 80 80 60 70 62-LM-030-5-11 62-LM-050-5-11 50 40 40 30 10 0 0.1 62-LM-030-5-11 62-LM-050-5-11 60 50 20 50Ω Level Meter 50Ω 62-LMF & LMB Insertion Loss (dB) Insertion Loss (dB) 70 50Ω 62-LM-100-5-11 20 62-LM-080-5-11 0.2 0.5 10 1 2 62-LM-100-5-11 30 5 Frequency (MHz) 10 20 50 0 0.1 62-LM-080-5-11 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF61 Power Line Filters Single Stage 62-PMF & PMB Series Tested and found to be IAW VDE 0565 Part 3 Features ■ ■ ■ ■ ■ ■ ■ ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF63) Circuit Diagram 1 CX CY ■ ■ ■ ■ ■ ■ ■ ■ E 4 2 Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Office automation equipment, such as copy and fax machines 3 CX R Applications ■ CY L1 Specifications Model* Rated Voltage (@ 50/60Hz) 62-PMB-050-5-11 62-PMF-050-5-11 62-PMB-080-5-11 62-PMF-080-5-11 62-PMB-100-5-12 62-PMF-100-5-12 62-PMB-150-5-13 62-PMF-150-5-13 62-PMB-200-5-13 62-PMF-200-5-13 250VAC Rated Current CX Inductance (L1) 5A 0.1uF 14mH 8A .1uF 7.0mH .22uF 4.2mH 10A Leakage Current (Max.) 0.50mA CY Capacitance 3300pF 15A Temperature Rise (Max.) 30°C 2.2mH 35°C 1.8mH 45°C** .33uF 20A Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 8.82 ounces ( 250 grams) * PMF - designates Fast-on terminals PMB - designates Bolt-in terminals ** The temperature rise of 20 amp units can be decreased to 30°C by mounting on 200 X 200 x 1.0(mm) steel chassis API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF62 Power Line Filters Single Stage 62-PMF & PMB Series 62-PMF 3.291 (83.7) B C Fast-on tab #250 2.937 (74.7) Temperature Characteristics 1.258 (32) 120 2 — .197 (5) .610 (15.5) 62-PMB 80 .610 (15.5) 2.497 (63.5) .315 (8) A 3.291 (83.7) B 5 — .157 (M4) 2.937 (74.7) 60 C 2 — .197 (5) 1.258 (32) 1.998 (50.8) 40 .649 (16.5) 20 MODEL 30 40 50 60 70 Ambient Temperature (°C) 80 90 Common Mode 1.258 .786 (32) (20) Oscillator 50Ω Oscillator 50Ω 90 80 62-PMB-050-5-11 Insertion Loss (dB) Insertion Loss (dB) 62-PMB-080-5-11 50 62-PMB-100-5-12 30 62-PMB-150-5-13 20 0 0.1 0.2 0.5 1 2 50Ω 5 Frequency (MHz) 20 50 R2 R1 S1 Filter S2 T1 T2 50Ω Level Meter 62-PMB-200-5-13 62-PMF-050-5-11 60 50 40 62-PMF-150-5-13 30 10 10 50Ω Level Meter 50Ω 70 20 62-PMB-200-5-13 10 Dimensions in inches (mm) 50Ω 50Ω 50Ω 50Ω Level Meter 90 40 0 (0) 1 3 Filter 2 4 80 60 C 62-PMF/PMB-050-080 62-PMB-050-6 R2 R1 S1 Filter S2 T1 T2 Oscillator 50Ω B 1.490 .944 .433 (38) (24) (11) 50Ω Level Meter 50Ω 62-PMB-050-6 A 62-PMF/PMB-100-200 Normal Mode 1 3 Filter 2 4 Oscillator 50Ω .315 (8) A 50Ω 20 50Ω 0 70 .649 (16.5) 2.497 (63.5) 50Ω Current (%) 100 1.998 (50.8) 0 0.1 62-PMF-080-5-11 62-PMF-100-5-12 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF63 Power Line Filters Single Stage 12-PMF Series Features ■ ■ ■ ■ ■ ■ ■ ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Operating temperature: -25°C to +85°C Circuit Diagram Circuit 1 Circuit 2 Circuit 3 Circuit 4 Circuit 5 Circuit 6 Applications ■ ■ ■ ■ ■ ■ ■ ■ ■ Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Office automation equipment, such as copy and fax machines Specifications Model Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) Circuit Diagram Figure 12-PMF-001-5-A 1A 1 A 12-PMF-002-5-B 2A 2 B 4 A 2 B 12-PMF-003-5-A 3A 12-PMF-003-5-B 12-PMF-006-5-A 6A 12-PMF-006-5-C 12-PMF-006-5-D 12-PMF-010-5-A 12-PMF-010-5-C 12-PMF-015-5-C 12-PMF-015-5-E 120/250VAC 10A A 1 C 6 D 2 A 3 15A 20A 12-PMF-020-5-E 30°C C E 5 12-PMF-020-5-C 12-PMF-020-5-D 0.5mA 4 Temperature Rise (Max.) C D E Note: Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF64 Power Line Filters Single Stage 12-PMF Series Figure A Figure B .14 (3.8) 2 .34 (8.8) 1.2 (30) 2.4 1.8 (62) (46) 2.1 (54) 1.7 (44) 2.2 (56) .78 (20) 3.2 (81) 1.25 (32) 2.4 (62) .86 (22) Figure D Figure C Figure E .41 (10.5) 2 .17 (8.8) 2- 1.7 (4.5) (2X) .18 (4.8) 2.0 (52) 2.0 (52) 2.4 (63) 1.9 2.3 2.8 (50) (60) (10.5) 1.4 (37) 2.5 3.3 (64) (85) 2.9 (74) 3.2 (82) 1.7 (44) Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 12-PMF-001;-002;-003;-006 80 12-PMF-002-5-B 12-PMF-003-5-B 12-PMF-006-5-A 40 12-PMF-003-5-A 30 20 12-PMF-006-5-C 12-PMF-006-5-D 10 12-PMF-006-5-C 12-PMF-006-5-A 60 12-PMF-006-5-D 50 40 30 12-PMF-003-5-B 20 12-PMF-003-5-A 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 12-PMF-002-5-B 0.2 0.5 1 Frequency (MHz) 12-PMF-001;-002;-003;-006 50 12-PMF-002-5-B 12-PMF-003-5-B 12-PMF-006-5-A 12-PMF-003-5-A 30 20 0 0.1 12-PMF-006-5-C 12-PMF-006-5-D 10 0.2 0.5 1 2 5 20 50 60 50 12-PMF-010-5-C 12-PMF-020-5-C 40 12-PMF-010-5-A 30 20 12-PMF-020-5-D 12-PMF-020-5-E 10 Frequency (MHz) 10 12-PMF-015-5-E 70 12-PMF-001-5-A 40 5 12-PMF-010;-015;-020 80 Insertion Loss (dB) Insertion Loss (dB) 60 2 Frequency (MHz) 80 70 50Ω Level Meter 50Ω 12-PMF-001-5-A 70 12-PMF-001-5-A Insertion Loss (dB) Insertion Loss (dB) 50 50Ω 12-PMF-001;-002;-003;-006 80 60 1.4 (36) 3.1 (80) Common Mode 70 2.0 (51) 1.1 (28) 2.9 (74) 10 20 50 0 0.1 1 12-PMF-015-5-C 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF65 Power Line Filters Single Stage - Higher Current 62-PMB Series Features ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Safety agency approvals pending Designed to be in accordance with VDE 0565 Part 3 Operating temperature: -25°C to +85°C (including temperature rise) Circuit Diagram 3 1 L1 CX CY CX R E CY L1 4 2 Applications ■ ■ ■ ■ ■ ■ ■ ■ ■ Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Office automation equipment, such as copy and fax machines Specifications Model Rated Voltage (@ 50/60Hz) 62-PMB-300-5-14 Rated Current CY Capacitance 0.50mA 3300pF CX 40A Inductance (L1) Temperature Rise (Max.) 1.6mH 30A 250VAC 62-PMB-400-5-14 Leakage Current (Max.) .47uF 45°C 0.8mH Note: Test voltage: 1500VAC one minute, line to earth Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 8.82 ounces (250 grams) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF66 Power Line Filters Single Stage - Higher Current 62-PMB Series 62-PMB-300-5-14 and 62-PMB-400-5-14 4.13 (105) 3.74 (95±.08) 3.15 (80) 3.03 (77±0.5) 0.511 (13.0) 3.70 (94) 3.85 (98) 1.022 (26.0) 5.591 (142.00) 2.049 (52.0) Dimensions in inches (mm) Common Mode Normal Mode 1 FILTER 2 1 4 2 50 ohm 50 ohm LEVEL METER 50 ohm 90 90 80 80 70 70 60 50 62-PMB-400-5-14 40 30 20 10 0 0.1 4 50 ohm LEVEL METER 50 ohm 60 50 62-PMB-300-5-14 40 30 20 62-PMB-300-5-14 3 FILTER OSCILLATOR 50 ohm Insertion Loss (dB) Insertion Loss (dB) OSCILLATOR 50 ohm 3 62-PMB-400-5-14 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF67 Power Line Filters Single Stage - Higher Current 12-PMB Series Features ■ ■ ■ ■ ■ ■ ■ ■ ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Designed to be in accordance with VDE 0565 Part 3 Operating temperature: -25°C to +85°C Circuit Diagram Applications ■ ■ ■ ■ ■ ■ ■ ■ ■ 3 1 L1 CX CY CX R L1 E CY 4 2 Digital equipment Computers and peripherals Measuring instruments Medical equipment Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Office automation equipment, such as copy and fax machines Specifications Model Rated Voltage (@ 50/60Hz) Rated Current 12-PMB-025-5-A 25A 12-PMB-030-5-A 30A 12-PMB-035-5-B 12-PMB-050-5-B 120/250VAC 35A Leakage Current (Max.) 100A 12-PMB-120-8-C 120A 1 1.0mA Figure Temperature Rise (Max.) A 0.5mA 50A 12-PMB-100-8-C Circuit Diagram B 30°C C Note: Test voltage: 1500VAC one minute, line to earth Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 8.82 ounces (250 grams) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF68 Power Line Filters Single Stage - Higher Current 12-PMB Series Figure A 1M4 STUD (4X) Figure B Figure C .17 (4.5) ±.007 (2X) 4.5±0.2 x 6.5±0.2 (4X) M6x1 (4X) M8 THREAD (4X) M6 THREAD (2X) 4.5 x 6.5 SLOT (4X) M4x0.7 2.0 (24) ±.03 2.0 (52) 0.2 (6) ±.03 84.0±2.0 44±1.0 2.5 (64) MAX 0.8 (22) ±.03 1.4 (37) MAX 19±1.0 2.9 (75) ±.01 105±2.0 100 65 115±0.5 130 50.8±0.5 98.5±2.0 38.5±2.0 3.9 (101) MAX 95.3±0.5 28 158.5±3.0 80±0.5 120 180 50 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 1 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 70 70 Insertion Loss (dB) Insertion Loss (dB) 80 12-PMB-025-5-A 50 40 30 12-PMB-035-5-B 20 12-PMB-030-5-A 10 0 0.1 0.2 0.5 1 2 60 50 12-PMB-025-5-A 40 12-PMB-030-5-A 30 20 10 10 5 12-PMB-035-5-B 20 0 0.1 50 0.2 0.5 1 70 70 12-PMB-100-8-C 50 40 30 12-PMB-050-5-B 12-PMB-120-8-C 10 0 0.1 0.2 0.5 1 2 10 5 20 50 12-PMB-050;-100;-120 80 Insertion Loss (dB) Insertion Loss (dB) 12-PMB-050;-100;-120 80 20 2 Frequency (MHz) Frequency (MHz) 60 50Ω Level Meter 50Ω 12-PMB-025;-030;-035 12-PMB-025;-030;-035 80 60 50Ω 5 Frequency (MHz) 10 20 12-PMB-050-5-B 60 50 1 12-PMB-120-8-C 40 12-PMB-100-8-C 30 20 10 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF69 Power Line Filters DC - Higher Current 12-PMF & 12 PMB DC Series Features ■ ■ ■ ■ ■ ■ ■ ■ ■ Space-saving, compact designs Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective shielding Excellent filtering characteristics for both normal mode and common mode Epoxy molded for internal component reliability Structure provides effective shielding for noise generated externally and internally Designed to be in accordance with VDE 0565 Part 3 Operating temperature: -40°C to +85°C Circuit Diagram Circuit 1 Circuit 2 Applications ■ ■ ■ ■ ■ ■ ■ Digital equipment Computers and peripherals Measuring instruments Equipment requiring very high impulse attenuation Factory automation equipment Industrial equipment such as UPS, inverters and converters Telecommunications equipment Circuit 3 Specifications Model 12-PMF-006-DC-C 12-PMF-010-DC-C 12-PMF-015-DC-C 12-PMF-020-DC-C 12-PMF-025-DC-D 12-PMB-025-DC-F 12-PMB-030-DC-F 12-PMB-035-DC-F 12-PMB-040-DC-F 12-PMB-040-DC-B 12-PMB-050-DC-B 12-PMB-060-DC-B 12-PMB-080-DC-G 12-PMB-080-DC-C 12-PMB-100-DC-C 12-PMB-120-DC-C 12-PMB-140-DC-C 12-PMB-180-DC-E 12-PMB-200-DC-E 12-PMB-260-DC-E Rated Voltage (@ 50/60Hz) Rated Current Circuit Diagram 6A 10A 15A 20A B 1 C 40A 48/250 VDC 50A 60A 80A 100A 120A 140A 180A 200A 260A Note: Test voltage: 1500VAC one minute, line to earth Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Temperature Rise (Max.) A 25A 30A 35A Figure D 2 3 2 30°C E F G Discharge time: 0.4 sec. max. Weight: 8.82 ounces (250 grams) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF70 Figure A Power Line Filters DC - Higher Current 12-PMF & 12-PMB DC Series Figure B Figure C Figure D Figure F Figure G 4.8 (2X) 20.0±1.0 4.0±1.0 10.5±0.5 44.0±1.0 50.0±1.0 8.0±1.0 10.0±1.0 60.0±0.5 28.5±1.0 70.5±1.0 Figure E 1.9 (50) ±.003 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 1 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 1 12-PMF-006;-010;-015;-020;-025 Insertion Loss (dB) 70 12-PMF-006;-010;-015;-020;-025 50 12-PMF-025-DC-D 40 30 12-PMF-015-DC-C 20 12-PMF-020-DC-C 10 0 0.1 0.2 0.5 1 12-PMF-025-DC-D 70 12-PMF-010-DC-C 60 2 5 10 60 12-PMF-020-DC-C 50 12-PMF-010-DC-C 40 12-PMF-015-DC-C 30 12-PMF-006-DC-C 20 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 12-PMB-080-DC-G 12-PMB-080-DC-C 12-PMB-025-DC-F 12-PMB-030-DC-F 12-PMB-035-DC-F 12-PMB-040-DC-F 50 40 12-PMB-180-DC-E 12-PMB-200-DC-E 12-PMB-260-DC-E 30 20 12-PMB-100-DC-C 12-PMB-120-DC-C 12-PMB-140-DC-C 10 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) 5 10 20 50 12-PMB-040-DC-B 12-PMB-050-DC-B 12-PMB-060-DC-B 10 20 12-PMB-025; thru -260 70 Insertion Loss (dB) 60 80 60 50 12-PMB-025-DC-F 12-PMB-030-DC-F 12-PMB-035-DC-F 12-PMB-040-DC-F 50 40 30 20 10 I Insertion Loss (dB) 70 2 Frequency (MHz) 12-PMB-025; thru -260 80 50Ω Level Meter 50Ω 80 12-PMF-006-DC-C Insertion Loss (dB) 80 50Ω 0 0.1 12-PMB-180-DC-E 12-PMB-200-DC-E 12-PMB-260-DC-E 0.2 0.5 12-PMB-080-DC-G 12-PMB-080-DC-C 12-PMB-040-DC-B 12-PMB-050-DC-B 12-PMB-060-DC-B 1 2 12-PMB-100-DC-C 12-PMB-120-DC-C 12-PMB-140-DC-C 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF71 Power Line Filters Dual Stage 62-MMF Series Features ■ ■ ■ ■ ■ ■ ■ Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Epoxy molded for reliability Structure provides effective shielding for noise generated both externally and internally Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF73) Circuit Diagram 62-MMF-XXX-7-11 1 L1 CX R Applications ■ ■ ■ ■ ■ CX CY L1 CY Digital equipment Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation CX CY CY 2 3 E 4 Specifications Model Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) CY1 Capacitance CY2 CX Inductance (L1) (2X) Temperature Rise (Max.) 62-MMF-030-7-11 250VAC 3A .7mA 3300pF 1000pF 0.1uF 3.7mH 30°C 62-MMF-050-7-11 250VAC 5A .7mA 3300pF 1000pF 0.1uF 2.9mH 30°C Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Leakage current: 0.7 mA max. Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 6.0 ounces (170 grams) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF72 Power Line Filters Dual Stage 62-MMF Series Temperature Characteristics 3.291 (83.7) 120 .786 (20) .315 (8) Fast-on tab #250 2.937 (74.7) Current (%) 100 80 .315 (8) 1.258 (32) 2 – .197 (5) 1.998 (50.8) 60 40 .610 (15.5) .610 (15.5) 2.497 (63.5) 1.258 (32) 20 Dimensions in inches (mm) 0 20 30 40 50 60 70 80 90 Ambient Temperature (°C) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 50Ω Oscillator 50Ω 62-MMF 90 80 80 70 70 60 Insertion Loss (dB) Insertion Loss (dB) 90 1 3 Filter 2 4 50Ω Level Meter 62-MMF-050-7-11 50 62-MMF-030-7-11 40 30 20 50Ω Level Meter 50Ω 62-MMF 60 62-MMF-050-7-11 50 62-MMF-030-7-11 40 30 20 10 0 0.1 50Ω 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF73 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Features ■ ■ ■ ■ ■ ■ Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Structure provides effective shielding for noise generated both externally and internally Operating temperature: -40°C to +85°C ■ High performance ■ Low leakage current Applications ■ ■ ■ ■ ■ ■ Digital equipment Switching power supplies Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation Circuit Diagram Circuit 1 Circuit 2 Circuit 3 Specifications Model 12-MMF-002-5-F 12-MMF-003-5-F 12-MMF-003-5-A 12-MMF-006-5-F 12-MMF-006-5-G 12-MMF-008-5-B 12-MMF-010-5-F 12-MMF-010-5-G 12-MMF-010-5-B 12-MMF-012-5-B 12-MMB-015-5-E 12-MMB-020-5-F 12-MMB-030-5-D 12-MMB-050-5-C Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) 2A Circuit Diagram 1 3A 3 6A 10A Temperature Rise (Max.) A A B A C 8A 120/250VAC Figure A A1 0.25mA@120VAC/ 0.5mA@250VAC 2 12A 15A 20A 30A 50A 30°C C D G E F Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Voltage drop: 1V max. Discharge time: 0.4 sec. max. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF74 Figure A Power Line Filters Dual Stage Figure A1 1.42 (36) 12-MMF & 12-MMB Series Figure B Figure C Ø .15 (3.8) (2X) M4 STUD (7X) 2.24 (57) 2.12 (54) 1.81 2.44 (46) (62) .21 (5.4) X .37 (9.4) HOLE (4X) 3.38 1.65 (86) (42) 2.40 .007 (60 .2) 2.90 (73) 2.42 (87) 4.01 (102) 1.77 (45) 1.26 (32) .87 (22) Figure D Ø .25 (6.4) (2X) 2.44 (62) .71 (18) 1.50 (38) 6.30 (160) 7.24 (184) 7.95 (202) 2.30 (58) Figure E M4 THREAD (5X) Figure F .117 (4.5) X .25 (6.3) SLOT (4X) Figure G M4 THREAD M4 THREAD (5X) M6 THREAD (4X) 4.5 x 6.5 (2X) 57 3.30 3.74 4.13 (84) (95) (105) 3.93 4.52 5.12 (100) (115) (130) 1.97 (50) 3.15 (80) 4.72 (120) 7.09 (180) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 70 70 60 12-MMF-002-5-F 50 12-MMF-003-5-F 40 12-MMF-006-5-F 12-MMF-006-5-G 30 50Ω 0 12-MMF-008-5-B 10 12-MMF-006-5-G 60 12-MMF-002-5-F 50 12-MMF-003-5-A 0.05 0.15 0.45 1 2 5 10 20 40 12-MMF-008-5-B 30 20 12-MMF-003-5-A 0 0.01 50 0.05 0.15 0.45 1 Frequency (MHz) 80 70 70 1 12-MMB-030-5-D 12-MMB-050-5-C 40 12-MMB-015-5-E 12-MMF-010-5-F 12-MMF-010-5-G 12-MMB-020-5-F 12-MMF-010-5-B 12-MMF-012-5-B 30 20 10 0 0.01 0.05 0.15 0.45 1 2 5 Frequency (MHz) 10 20 50 Insertion Loss (dB) Insertion Loss (dB) 12-MMF-010;-012;-015;-020;-030;-050 50 2 5 10 20 50 Frequency (MHz) 80 60 12-MMF-006-5-F 12-MMF-003-5-F 10 0 0.01 50Ω Level Meter 50Ω 12-MMF-002;-003;-006;-008 80 Insertion Loss (dB) Insertion Loss (dB) 12-MMF-002;-003;-006;-008 80 20 73 87 109 MAX 45 2.01 (51) 3.88 (98.5) 5.31 (135) 1.51 (38.5) 12-MMF-010;-012;015;-020;-030;-050 12-MMB-050-5-C 60 50 40 12-MMB-030-5-D 30 12-MMF-010-5-F 12-MMF-010-5-G 12-MMF-010-5-B 12-MMF-012-5-B 12-MMB-015-5-E 12-MMB-020-5-F 20 10 0 0.01 0.05 0.15 0.45 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF75 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Features ■ ■ ■ ■ ■ ■ ■ Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Structure provides effective shielding for noise generated both externally and internally Operating temperature: -40°C to +85°C Circuit Diagram Circuit 1 High performance Applications ■ ■ ■ ■ ■ Digital equipment Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation Circuit 2 Specifications Model 12-MMF-003-11-F 12-MMF-006-11-F 12-MMF-010-11-F 12-MMB-015-11-G 12-MMB-020-11-D 12-MMB-030-11-D 12-MMB-040-11-B 12-MMB-040-11-E 12-MMB-050-11-H Rated Voltage (@ 50/60Hz) 120/250VAC Rated Current 3A 6A 10A 15A 20A 30A Leakage Current (Max.) Circuit Diagram Figure 1 A Temperature Rise (Max.) C 1.5mA 40A 50A 1 2 1 B 30°C D E F Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Leakage current: 0.7 mA max. Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 6.0 ounces (170 grams) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF76 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Figure A Figure C Figure B 04.5 ±0.2 x 7.0 ±0.2, 4 PLCS. M4 THREAD, 2 PLCS. 3.74 1.73 3.33 ± .02 ± .04 MAX (44 ± 1) (84.5) (95 ± 0.5) .75 ± .04 (19 ± 1) 1.53 MAX (39) Figure D .25 (6.4) x .37(9.4) SLOT (4X) 2.28 (58) M4 THREAD M6 THREAD, 4 PLCS. 58 (2.283) ±0.5 103 (4.055) ±2 144 (5.669) ±0.5 160 (6.299) ±2 190 (7.480) ±3 60 (2.362) ±2 Figure F M6 THREAD (4X) 4.5±0.2 x 6.5±0.2 SLOT (4X) .165 (4.2) X .25 (6.4) (4X) M8 THREAD (4X) 84.0±2.0 3.54 5.90 (90) (150) 1.77 (45) 70 (2.756) ±2 40 (1.575) ±1 30 (1.181) ±1 2.01 ± .02 (51 ± 0.5) 3.90 MAX (99) 6.20 MAX (157) Figure E M6 THREAD (5X) 3.54 (90) 4.13 MAX (105) 44±1.0 8.66 (220) 9.57 (243) 10.27 (261) 95.3±0.5 19±1.0 3.93 4.53 5.12 (100) (115) (130) 105±2.0 50.8±0.5 38.5±2.0 1.97 (50) 98.5±2.0 158.5 3.14 (80) 4.72 (120) 7.08 (180) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 12-MMF/MMB-003;-006;-010;-012;-015 Insertion Loss (dB) 105 90 120 12-MMF-003-11-F 1 75 60 12-MMF-006-11-F 45 30 15 0 0.1 12-MMF-010-11-F 12-MMB-015-11-G 0.2 0.5 1 12-MMF-012-11-A 12-MMF-003-11-F 90 75 60 45 12-MMB-015-11-G 30 12-MMF-006-11-F 15 2 5 10 20 0 50 12-MMF-010-11-F 0.1 0.2 0.5 1 Frequency (MHz) 120 105 90 75 60 45 30 12-MMB-040-11-E 15 0 12-MMB-030-11-D 0.1 0.2 0.5 1 5 Frequency (MHz) 10 20 50 10 12-MMB-040-11-B 90 75 60 45 12-MMB-050-11-H 30 12-MMB-040-11-E 15 12-MMB-050-11-H 2 5 12-MMB-020;-030;-040;-050 120 12-MMB-020-11-D Insertion Loss (dB) Insertion Loss (dB) 105 2 Frequency (MHz) 12-MMB-020;-030;-040;-050 12-MMB-040-11-B 50Ω Level Meter 50Ω 12-MMF/MMB-003;-006;-010;-012;-015 105 12-MMF-012-11-A Insertion Loss (dB) 120 50Ω 20 50 0 12-MMB-030-11-D 12-MMB-020-11-D 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF77 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Features ■ ■ ■ ■ ■ ■ ■ Suitable for products that must conform to FCC regulations Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Two stages for excellent filtering characteristics Epoxy molded for reliability Structure provides effective shielding for noise generated both externally and internally Operating temperature: -25°C to +85°C Circuit Diagram Circuit 1 Applications ■ ■ ■ ■ ■ Digital equipment Personal computers and peripherals Measuring instruments and medical equipment Telecommunications equipment Equipment requiring very high noise attenuation Circuit 2 Circuit 3 Specifications Model 12-MMF-001-5-F 12-MMF-003-5-G 12-MMF-003-2-G 12-MMF-006-5-G 12-MMB-010-5-D 12-MMB-015-5-E 12-MMB-020-5-E 12-MMB-030-5-E Rated Voltage (@ 50/60Hz) Rated Current 1A 3A 120/250VAC 6A 10A 15A 20A 30A Leakage Current (Max.) Circuit Diagram 0.5mA 3 5uA 1 Figure A B C 0.5mA Temperature Rise (Max.) 30°C 2 D Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3 Test voltage: 1500VAC one minute, line to ground Insulation resistance: 300 Mohm min. at 500VDC Leakage current: 0.7 mA max. Voltage drop: 1V max. Discharge time: 0.4 sec. max. Weight: 6.0 ounces (170 grams) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF78 Power Line Filters Dual Stage 12-MMF & 12-MMB Series Figure B Figure A 2.01 (51) 2.52 (64) 2.95 (75) 3.70 (94) 1.06 (27) Figure C M4 THREAD (5X) Figure D .25 (6.4) .37 (9.4) HOLE (4X) M4 STUD (7X) 3.33 1.73 ± .03 (84.5) (44 ± 1) MAX 3.74 ± .02 (95 ± 0.5) 4.13 MAX. (64) 0.75 ± .03 (19 ± 1) 2.36 ± .007 (60 ± .2) 3.38 1.65 (86) (42) 2.01 ± .02 (51 ± .05) 1.52 (39) MAX 2.28 (58) 3.15 (99) MAX 5.31 (135) MAX Common Mode 1 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 12-MMF-001;-003;-006 120 Insertion Loss (dB) Insertion Loss (dB) 90 75 60 45 30 12-MMF-003-2-G 15 0 0.1 0.2 0.5 12-MMF-001-5-F 1 2 12-MMF-003-2-G 90 75 60 12-MMF-003-5-G 45 30 12-MMF-001-5-F 15 10 5 20 0 50 0.1 0.2 0.5 1 Frequency (MHz) 120 12-MMB-010-5-D 12-MMB-015-5-E 105 12-MMB-020-5-E 90 75 60 12-MMB-030-5-E 45 30 10 20 50 12-MMB-010-5-D 12-MMB-015-5-E 12-MMB-020-5-E 90 75 12-MMB-030-5-E 60 45 30 15 15 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 I 0 5 12-MMB-010;-015;-020;-030 120 Insertion Loss (dB) Insertion Loss (dB) 105 2 Frequency (MHz) 12-MMB-010;-015;-020;-030 1 50Ω Level Meter 50Ω 12-MMF-006-5-G 105 12-MMF-003-5-G 50Ω 12-MMF-001;-003;-006 120 12-MMF-006-5-G 105 Dimensions in inches (mm) Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 7.09 (180) 7.24 (184) 7.95 (202) .71 (18) 1.50 (38) Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF79 Power Line Filters Three Phase Low Current/High Performance 62-PMB/63-PMF Series Features ■ ■ ■ ■ ■ ■ ■ ■ ■ Excellent attenuation for high voltage impulse Effective for both balanced and unbalanced three-phase loads Metal case provides effective EMI shielding Epoxy molded for internal component reliability Compact and economical Excellent filtering characteristics for both normal and common mode Various current ratings available: 3, 5, 8 and 16 Amps Safety agency approvals pending Operating temperature: -25°C to +85°C (including temperature rise, see graph on page PF81) ■ ■ ■ 62-PMB-050-6-12 (5 Amp Delta) L L L L CX CX CY CX L CY L CY 63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp Wye) Applications ■ Circuit Diagram CX L Digital equipment Industrial equipment (UPS, inverters and converters) Automation equipment Computerized washing machines L CY CX L CY CX CY L CY 63-PMF-160-9-21 (16 Amp Wye) L L L CX CX CX L CY CX CX CX CY Specifications Model Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) CY 62-PMB-050-6-12 250VAC 5A 0.6mA 3A 63-PMF-030-8-14 63-PMF-080-8-14 63-PMF-160-9-21 480VAC 8A 16A Capacitance CX Inductance (L1) Temperature Rise (Max.) 2200pF 0.22uF 115mH 45°C 1.0mA 4700pF (4X) 470uF (3X) 3.0mA 0.015uF (2X) 1.0uF (6X) 1.0mH (4X) 30°C 0.74mH (4X) 40°C 1.2mH (4X) 45°C Note: Test Voltage 1500VAC one minute, line to ground. Insulation Resistance: 300 MΩ min. at 500VDC. Voltage Drop: 1V max. at rated current. Weight: 8.82 ounces (250 grams) for 63-PMF-030-8-14 and 63-PMF-080-8-14 19.4 ounces (550 grams) for 62-PMB-050-6-12 51.5 ounces (1450 grams) for 63-PMF-160-9-21 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF80 Temperature Characteristics Power Line Filters Three Phase Low Current/High Performance 62-PMB/63-PMF Series 62-PMB-050-6-12 (5 Amp) 5 — .157 (M4) .865 (22) 2.753 (70) 3.460 3.539 (88) (90) .865 (22) .039 (1) * General .944 (24) tolerance ±.020 (0.5) 1.376 (35) 63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp) 4.444 (113) 4.050 (103) Fast-on tab #250 2 - .197 (ø5) Hole .547 (13.9) .547 (13.9) 3.585 (91.2) .629 (16) .708 (18) BL BK BL 1.809 (46) Dimensions in inches (mm) BK .208 (5.3) .350 (8.9) .362 (9.2) 4.404 (112) .350 (8.9) .350 (8.9) 4.286 (109) Fast on tab #250 (Ground tab) 3.146 (80.0±0.5) 5.112 (130.0) 5.702 (145 ± 0.5) 6.292 (160) Common Mode 4 - .216 (ø5.5) Hole Fast on tab #250 2.045 (52) .983 (25) 63-PMF-160-9-21 (16 Amp) * General tolerance ±..059 (1.5) 1.494 (38) 2.359 (60) .708 (18) Normal Mode 62-PMB-050-6-12 (5 Amp) 62-PMB-050-6-12 (5 Amp) 63-PMF (3, 8 and 16 Amp) 63-PMF (3, 8 and 16 Amp) 63-PMF-160-9-21 63-PMF-160-9-21 63-PMF-080-8-14 63-PMF-030-8-14 63-PMF-030-8-14 63-PMB-050-8-12 63-PMF-080-8-14 63-PMB-050-8-12 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF81 Power Line Filters Three Phase 13-PWF/PWL/PWB Series Features ■ ■ ■ ■ ■ ■ ■ ■ Excellent attenuation for high voltage impulse Effective for both balanced and unbalanced three-phase loads Metal case provides effective EMI shielding Epoxy molded for internal component reliability Suitable for both Wye and Delta connection Excellent filtering characteristics for both normal and common mode Operating temperature: -40°C to +85°C Circuit Diagram Circuit 1 ■ ■ ■ A' B B' C C' N G N' Designed for 3-phase 4-line power supply systems Applications ■ A Digital equipment Industrial equipment (UPS, inverters and converters) Automation equipment Computerized washing machines Circuit 2 A A' B B' C C' N G N' Specifications Model 13-PWF-005-12-H 13-PWL-005-12-C 13-PWF-010-12-H 13-PWL-010-12-C 13-PWB-010-12-D 13-PWB-015-12-D 13-PWB-020-12-D 13-PWB-025-12-D 13-PWB-030-12-D Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) Circuit Diagram Figure 1 A B A B 5A 10A 1.5mA 440/250VAC 15A 20A 25A 30A Temperature Rise (Max.) 30°C 2 C Note: Test Voltage 1500VAC one minute, line to ground. Insulation Resistance: 300 MΩ min. at 500VDC. Voltage Drop: 1V max. at rated current. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF82 Figure B Power Line Filters Three Phase 13-PWF/PWL/PWB Series Figure A Figure C 2.0 (51) 3.9 (98.5) 5.3 (135) Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 13-PWF-005;-010;-PWL-005;-010;-PWB-010 80 Insertion Loss (dB) Insertion Loss (dB) 50 40 30 13-PWF-010-12-H 13-PWL-010-12-C 13-PWB-010-12-D 20 10 0 0.1 13-PWB-010-12-D 70 60 60 50 40 13-PWF-005-12-H 13-PWL-005-12-C 30 20 13-PWF-010-12-H 13-PWL-010-12-C 10 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 13-PWB-015;-020;-025:-030 40 30 13-PWB-030-12-D 20 10 0 0.1 10 20 50 10 20 50 13-PWB-015-12-D 13-PWB-020-12-D 13-PWB-025-12-D 70 Insertion Loss (dB) Insertion Loss (dB) 50 5 13-PWB-015;-020;-025:-030 80 13-PWB-015-12-D 13-PWB-020-12-D 13-PWB-025-12-D 60 2 Frequency (MHz) 80 70 50Ω Level Meter 50Ω 13-PWF-005;-010;-PWL-005;-010;-PWB-010 80 13-PWF-005-12-H 13-PWL-005-12-C 70 50Ω 1 60 50 40 13-PWB-030-12-D 30 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF83 Power Line Filters Three Phase High Performance 13-PDF/PDL/PDB Series Features ■ ■ ■ ■ ■ ■ ■ ■ Excellent attenuation for high voltage impulse Effective for both balanced and unbalanced three-phase loads Metal case provides effective EMI shielding Epoxy molded for internal component reliability Compact and economical Excellent filtering characteristics for both normal and common mode Operating temperature: -40°C to +85°C Circuit Diagram Circuit 1 ■ ■ ■ A' B B' C C' Designed for 3-phase, 3-Delta connection system Applications ■ A Digital equipment Industrial equipment (UPS, inverters and converters) Automation equipment Switching power supplies G Circuit 2 A A' B B' C C' G Specifications Model 13-PDF-005-11-J 13-PDL-005-11-D 13-PDF-010-11-J 13-PDL-010-11-D 13-PDB-010-11-D 13-PDB-015-11-D 13-PDB-020-11-D 13-PDB-025-11-D 13-PDB-030-11-D Rated Voltage (@ 50/60Hz) Rated Current Leakage Current (Max.) Circuit Diagram Figure 1 A B A B 5A 10A 1.5mA 440/250VAC 15A 20A 25A 30A Temperature Rise (Max.) 30°C 2 C Note: Test Voltage 1500VAC one minute, line to ground. Insulation Resistance: 300 MΩ min. at 500VDC. Voltage Drop: 1V max. at rated current. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF84 Figure B Ø .177 (4.5) (2X) Power Line Filters Three Phase 2.00 (51) High Performance 13-PDF/PDL/PDB Series 2.52 (64) 1.06 (27) 2.95 (75) 3.35 (85) Figure A Figure C Ø .177 (4.5) (2X) 95.3±0.5 2.52 2.91 3.35 (64) (74) (85) 1.42 (36) 6.5±0.2 (4X) 4.5±0.2 (4X) M4 THREAD (8X) 50.0±1.0 12.5±1.0 2.00 (51) 84.0±2.0 105.0±2.0 11.5±1.0 26.5±1.0 50.8±0.5 98.5±2.0 38.5±2.0 3.15 (80) 134.5±3.0 Dimensions in inches (mm) Common Mode Normal Mode 1 3 Filter 2 4 Oscillator 50Ω 1 3 Filter 2 4 50Ω Level Meter 50Ω Oscillator 50Ω 13-PDF-005;-010; PDL-005;-010 PDB-010 80 Insertion Loss (dB) Insertion Loss (dB) 13-PDB-010-11-D 70 60 50 40 13-PDB-010-11-D 30 13-PDF-010-11-J 13-PDL-010-11-D 20 10 60 50 13-PDF-010-11-J 13-PDL-010-11-D 40 30 13-PDF-005-11-J 13-PDL-005-11-D 20 10 0 0.1 0.2 0.5 1 2 5 10 20 0 0.1 50 0.2 0.5 1 Frequency (MHz) 13-PDB-015;-020;-025:-030 70 40 30 13-PDB-030-11-D 20 10 0 0.1 10 20 50 10 20 50 13-PDB-015;-020;-025:-030 Insertion Loss (dB) Insertion Loss (dB) 50 5 80 13-PDB-015-11-D 13-PDB-020-11-D 13-PDB-025-11-D 60 2 Frequency (MHz) 80 70 50Ω Level Meter 50Ω 13-PDF-005;-010; PDL-005;-010 PDB-010 80 13-PDF-005-11-J 13-PDL-005-11-D 70 50Ω 13-PDB-030-11-D 60 50 40 13-PDB-015-11-D 13-PDB-020-11-D 13-PDB-025-11-D 30 20 10 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF85 Power Line Filters Three Phase High Performance 13-PWB Series Features ■ ■ ■ ■ ■ ■ ■ Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Circuit Epoxy molded for internal component reliability Excellent filtering characteristics for both normal and common mode Circuit 1 Various current ratings available: from 5 to 150 Amps A Operating temperature: -40°C to +85°C Designed for 3-phase, 4-line power systems Applications ■ ■ ■ ■ Power supplies for data systems Industrial equipment (UPS, inverters and converters) Automation equipment Telecommunications systems and equipment Diagram A' B B' C C' N G N' Circuit 2 A A' B B' C C' N G N' Specifications Model 13-PWB-005-12-A 13-PWB-010-12-B 13-PWB-020-12-B 13-PWB-035-12-C 13-PWB-050-13-C 13-PWB-080-14-D 13-PWB-100-14-D 13-PWB-150-14-E Rated Voltage (@ 50/60Hz) Rated Current 480/277VAC 5A 10A 20A 35A 50A 80A 100A 150A Leakage Current (Max.) Circuit Diagram 4.5mA 1 30°C 9.0mA 20mA Temperature Rise (Max.) 2 Note: Test Voltage 1500VAC one minute, line to ground. Insulation Resistance: 300 MΩ min. at 500VDC. Voltage Drop: 1V max. at rated current. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF86 H Power Line Filters Three Phase P M E F D High Performance I L 13-PWB Series K B A C G N J Dimensions Dimensions in inches (mm) A Model B C 13-PWB-005-12-A 7.2 (184) 6.3 (160) 7.9 (202) 13-PWB-010-12-B 13-PWB-020-12-B 13-PWB-035-12-C 9.6 (243) 8.7 (220) 10.3 (261) 13-PWB-100-14-D 13-PWB-150-14-E 13.9 (354) 12.6 (320) E 2.4 (60) 1.7 (44) 3.1 (81) 13-PWB-050-13-C 13-PWB-080-14-D D 3.9 (99) 15.1 (384) F G H I 3.5 (86) .70 (18) 2.3 (58) 3.9 (100) 3.8 (96) 4.9 (125) 6.1 (155) 7.3 (185) M4 .98 (25) 3.5 (90) M6 1.2 (30) M8 7.5 (190) 8.7 (220) 1.4 (35) 3.9 (100) Oscillator 50Ω 50Ω 13-PWB-020-12-A 13-PWB-035-12-A 13-PWB-005-12-A 0.2 0.5 1 – – – M4 2.9 (74) 1.9 (49) .25 x .37 (6.4 x 9.4) 2.4 (62) M4 2 5 10 20 .25 x .36 (6.4 x 9.11) 50Ω 50Ω Level Meter 50Ω 13-PWB-010-12-A 13-PWB-005-12-A 13-PWB-020-12-A 75 60 13-PWB-035-12-A 45 30 0.1 0.2 0.5 1 2 5 10 20 50 13-PWB-050;-080;-100;-150 120 75 13-PWB-150-14-E 13-PWB-050-13-C 45 30 15 13-PWB-080-14-D 13-PWB-100-14-D 105 Insertion Loss (dB) Insertion Loss (dB) .25 x .36 (6.4 x 9.10) Frequency (MHz) 13-PWB-100-14-D 90 0 .25 x .39 (6.4 x 9.9) M8 2.4 (61) 90 0 50 13-PWB-080-14-D 60 .25 x .38 (6.4 x 9.8) 15 13-PWB-050;-080;-100;-150 105 .25 x .38 (6.4 x 9.7) M6 2.2 (56) 3.4 (86) Frequency (MHz) 120 1 .25 x .37 (6.4 x 9.5) .25 x .38 (6.4 x 9.6) 2.3 (58) 105 90 0 0.1 L 13-PWB-005;-010;-020;-035 120 13-PWB-010-12-A 15 P Oscillator 50Ω Insertion Loss (dB) Insertion Loss (dB) 105 30 N 1 3 Filter 2 4 13-PWB-005;-010;-020;-035 45 1.8 (45) 50Ω Level Meter 120 60 M Normal Mode 1 3 Filter 2 4 75 K 1.5 (38) Common Mode 1 J 90 75 13-PWB-050-13-C 60 45 13-PWB-150-14-E 30 15 0.1 0.2 0.5 1 2 5 Frequency (MHz) 10 20 50 0 0.1 0.2 0.5 1 2 5 10 20 50 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF87 Power Line Filters Three Phase High Performance 13-PDB Series Features ■ ■ ■ ■ ■ ■ ■ Excellent attenuation for high voltage impulse Metal case provides effective EMI shielding Epoxy molded for internal component reliability Excellent filtering characteristics for both normal and common mode Various current ratings available: from 5 to 200 Amps Operating temperature: -40°C to +85°C Designed for 3-phase, 3-line connection systems Applications ■ ■ Digital equipment Industrial equipment (UPS, inverters and converters) Circuit Diagram Circuit 1 A A' B B' C C' G Circuit 2 A A' B B' C C' G Specifications Model 13-PDB-005-12-A 13-PDB-010-12-A 13-PDB-020-12-B 13-PDB-035-12-B 13-PDB-050-12-B 13-PDB-080-13-C 13-PDB-100-14-C 13-PDB-150-14-C 13-PDB-200-14-D Rated Voltage (@ 50/60Hz) Rated Current 480/277VAC 5A 10A 20A 35A 50A 80A 100A 150A 200A Leakage Current (Max.) Circuit Diagram Temperature Rise (Max.) 4.5mA 1 30°C 9.0mA 20mA 2 Note: Test Voltage 2250VDC one minute, line to ground. Insulation Resistance: 500MΩ. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF88 Power Line Filters Three Phase F D High Performance I L P H M E 13-PDB Series B A C G N J K Dimensions Model A B C D E F G H I J K M N Dimensions in inches (mm) P L 13-PDB-005-12-A 7.2 (184) 6.3 (160) 7.9 (202) 1.6 (42) 2.4 (60) 3.3 (86) .70 (18) 2.3 (58) M4 1.5 (38) – – – M4 9.6 (243) 8.7 (220) 10.3 (261) 2.3 (58) 2.7 (70) 3.9 (100) .98 (25) M6 2.3 (58) 1.9 (49) M6 6.1 (155) 7.3 (185) 1.2 (30) 13-PDB-010-12-A 13-PDB-020-12-B 13-PDB-035-12-B 13-PDB-050-12-B 13-PDB-080-13-C 13-PDB-100-14-C 13.9 (354) 13-PDB-150-14-C 12.6 (320) 15.1 (384) 2.5 (66) 13-PDB-200-14-D 3.5 (90) M8 Oscillator 50Ω Oscillator 50Ω 13-PDB-005;-010;-020;-035 120 120 90 75 13-PDB-035-12-B 13-PDB-005-12-A 0.01 0.02 .1 1 10 13-PDB-005;-010;-020;-035 13-PDB-010-12-A 13-PDB-005-12-A 75 60 45 13-PDB-035-12-B 30 13-PDB-020-12-B 15 20 30 0 0 60 0.01 0.02 .1 Frequency (MHz) 13-PDB-050;-080;-100;-150;-200 90 1 120 105 13-PDB-100-14-C 13-PDB-050-12-B 13-PDB-080-13-C 75 60 45 13-PDB-150-14-C 30 13-PDB-200-14-D 15 0 0 Insertion Loss (dB) Insertion Loss (dB) 105 0.01 0.02 .1 1 10 Frequency (MHz) 1 10 20 30 60 Frequency (MHz) 13-PDB-050;-080;-100;-150;-200 13-PDB-100-14-C 13-PDB-050-12-B 90 13-PDB-200-14-D 75 60 45 13-PDB-080-13-C 30 13-PDB-150-14-C 15 20 30 60 I 120 50Ω Level Meter 50Ω 90 13-PDB-010-12-A 0 0 50Ω 105 13-PDB-020-12-B Insertion Loss (dB) Insertion Loss (dB) 105 15 .25 x .36 (6.4 x 9.11) .25 x .36 (6.4 x 9.12) 1 3 Filter 2 4 50Ω Level Meter 50Ω 30 M8 .25 x .36 (6.4 x 9.10) Normal Mode 1 3 Filter 2 4 45 .25 x .38 (6.4 x 9.7) .25 x .39 (6.4 x 9.9) 2.4 (61) 7.5 (190) 8.6 (220) 1.4 (35) 3.9 (100) 60 .25 x .38 (6.4 x 9.6) 2.2 (56) 3.3 (86) 2.4 (62) .25 x .37 (6.4 x 9.5) .25 x .38 (6.4 x 9.8) M4 Common Mode 1 2.9 (74) .25 x .37 (6.4 x 9.4) 0 0 0.01 0.02 .1 1 10 20 30 60 Frequency (MHz) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF89 Commercial-Off-The-Shelf (COTS) Filters API Technologies’ Spectrum Control brand now offers COTS single line feed-through EMI filters that are the commercial equivalent to M15733-PRF/72, M15733PRF/73 and M15733-PRF/74. These reliable AC and DC high performance filters provide an excellent source of filtering in a compact package and are well suited for the military and aerospace industries. They filter up to 500 A with an attenuation of 40 to 90 dB from 1 MHZ to 1 GHz and voltage rating of 130 VDC to 250 VAC. Please reference API mechanical drawing. Dimensions F B E WORKORDER NO. C D DATE CODE SINGLE "D" MOUNTING FLAT .025 (.64) SHOULDER A MIL part M15733/ Part Number A ±0.100 B ±0.032 C ±0.010 D ±0.010 E ±0.100 F Max Mounting Flat ±0.015 72-0034 72-0046 72-0043 72-0049 72-0053 73-0034 73-0043 73-0046 73-0049 73-0051 73-0053 74-0030 74-0036 74-0042 74-0045 5004-7053-100-A 5004-7053-100-A 5004-7053-100-A 5004-7059-100-A 5004-7065-100-A 5004-7058-125-A 5004-7058-125-A 5004-7052-125-A 5004-7058-125-A 5004-7059-250-A 5004-7064-125-A 5004-7041-250-A 5004-7047-250-A 5004-7053-250-A 5004-7059-250-A 6.750 6.750 6.750 7.250 8.781 7.250 7.250 6.750 7.250 7.250 8.781 4.750 6.500 6.750 7.250 0.375 0.375 0.375 0.375 0.531 0.375 0.375 0.375 0.375 0.375 0.531 0.310 0.310 0.375 0.375 0.930 0.930 0.930 0.930 1.625 0.930 0.930 0.930 0.930 0.930 1.625 0.616 0.616 0.930 0.930 1.500 1.500 1.500 2.000 2.250 2.000 2.000 1.500 2.000 2.000 2.250 1.000 1.000 1.500 2.000 0.750 0.750 0.750 0.750 1.000 0.750 0.750 0.750 0.750 0.750 1.000 0.600 0.750 0.750 0.750 4.875 4.875 4.875 5.375 6.250 5.375 5.375 4.875 5.375 5.375 6.250 3.400 4.750 4.875 5.375 0.656 0.656 0.656 0.656 1.046 0.656 0.656 0.656 0.656 0.656 1.046 0.437 0.473 0.656 0.656 Shielded Filters API has developed a new MRI filter product line which provides MRI/RF shielding solutions for medical, commercial and government applications. Offers 100 dB insertion loss per MIL-STD 220 from 14 KHz to 10 GHZ. Shielded Room Filters P/N Series 52-1490 Configuration* Description 1x5 1 x 30 1 x 100 1 x 150 1 x 200 1 x 225 2 x 0.5 2 x 1 ALRM 2x5 2 x 20 2 x 30 2 x 50 2 x 60 1 x 5 A, 277 VAC 1 x 30 A, 277 VAC 1 x 100 A, 277 VAC 1 x 150 A, 277 VAC 1 x 200 A, 277 VAC 1 x 225 A, 277 VAC Speaker Filter Fire Alarm Filter 2 x 5 A, 277 VAC 2 x 20 A, 277 VAC 2 x 30 A, 277 VAC 2 x 50 A, 277 VAC 2 x 60 A, 277 VAC * Add to P/N series (eg. 52-1490-1x5) Options are available with or without discharge light “L” at the end of the part (52-1490-1x5L). Custom configurations are available. Consult factory. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF90 Military/Aerospace Multisection Filters API Technologies’ Spectrum Control brand will address virtually any requirement for a military/custom power product. Our engineering expertise and vertical integrations reduce your speed to market as well as saves you money. Our electromagnetic compatibility expertise in the tempest arena can help you meet MIL-F-15733 and MIL-STD 461 standard requirements. Features Applications ■ Military ■ Commercial and military/aerospace ■ High common and differential mode attenuation ■ Standard designs up to 400 Amps Secured communications ■ ■ Excellent insertion loss characteristics up to 10 GHz Switching power supplies ■ ■ Voltage rating 115-250VAC and 400VDC up to 400 Hz Data processing equipment ■ ■ Available to meet TEMPEST and FCC requirements Ruggedized computers ■ ■ Custom designs for application-specific requirements Radar ■ ■ Electronic warfare ■ Ground/air weapon systems ■ Satellites ■ Ship board systems ■ Land based vehicles ■ Fixed and mobile control stations Test Specifications The high performance power line filters shown on pages 59 and 60 are designed to meet the following criteria. The information shown can be used as a basis for filter specifications. (Contact factory for additional details). Test Group IIA IIB III Order of Test Examination or Test Test Method (Per MIL-STD-202) Post Test Requirements 1 Voltage Drop Paragraph 4.6.8 of MIL-F-15733 Three percent of rated voltage max. 2 Leakage Current UL 1283 Per applicable specification 3 Temperature Rise MIL-F-15733 Paragraph 4.6.4 25°C max. 4 Terminal Strength Method 211, Condition A No evidence of loosening or rupture. 5 lb. applied force. Line Cords: 35 Lbs. 1 Shock, Medium Impact Method 213, Condition G Must pass DWV and Insertion Loss 2 Vibration, High Frequency Method 204, Condition A Monitor for shorts or open 3 Thermal Shock Method 107, Test Condition A Pass 90% DWV IR to be 30% of initial 4 Humidity Method 107, Condition B, except temperature equals 25°C Pass 90% DWV IR to be 30% of initial 1 Life Method 108, Condition D 1.2 x Rated AC voltage at max. operating temp. or 1.4 x DC voltage Pass 90% DWV insulation resistance to be 30% of initial. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF91 Military/Aerospace Multisection Filters Insertion Loss 52-600-001 Insertion Loss (dB) 80 differential mode 60 Circuit Schematic 40 common mode 20 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 100 1000 LINE LOAD 52-600-002 Insertion Loss (dB) 80 60 common mode 40 20 0 0.01 differential mode 0.1 1 10 Frequency (MHz) Dimensions 1.250 (31.75) .250 Fast-on tabs (3 PL.) .240 (6.10) SWITCH 52-600-001 52-600-002 .215 (5.46) FUSE CONNECTOR .250 (6.35) 2.500 (63.50) .625 (15.8) 1.68 (42.67) 2.98 (75.70) #6-32 THREADED INSERTS (4 PL.) (3.50-32) Model Temperature Rating DCR. max. (ohms) Leakage Current (max.) Mode (max.) 52-600-001 5A 120/240VAC -40°C to +65°C .20 1 mA 60 Hz 120/240VAC 60 Hz 2.120 ± .010 (53.85) Dimensions in inches (mm) Voltage Rating 10A .03 R. 4 PL 2.500 (63.50) CHASSIS MOUNTING HOLE 3.88 (98.55) Current Rating 52-600-002 1.250 (31.75) -40°C to +65°C .10 1 mA Minimum Insertion Loss (db) Per MIL-STD-220 50K 150K 300K 1M 10M 100M 1G COMM 33 65 80 80 80 80 60 DIFF 37 65 80 80 80 – – COMM – 50 70 80 80 70 60 DIFF 25 50 75 80 80 – – Consult factory for UL/CSA approval availability. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF92 Military/Aerospace Multisection Filters Circuit Schematic Insertion Loss 52-523-002 52-523-002 LINE Insertion Loss (dB) 80 LOAD 60 40 20 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 Dimensions 52-523-002 .750 (19.05) .600 (15.24) 2.010 (51.05) .250 (6.35) .250 (6.35) 3.000 (76.2) .375 (9.52) FUSEHOLDER 1.75 .875 (44.4) (22.2) 3.50 .875 (88.9) (22.2) PLUG #6-32 THDED INSERT 4 PLCS. (3.50-32) 4.00 (101.6) .625 (15.8) 1.25 (31.75) Dimensions in inches (mm) Model Current Rating Voltage Rating Temperature Rating DCR max. (ohms) Leakage Current (max.) Mode (max.) 52-523-002 5A 120/240VAC -40°C to +65°C .25 1 mA COMM – 55 60 80 80 70 60 DIFF – 50 60 80 80 – – 60 Hz Minimum Insertion Loss (db) Per MIL-STD-220 50K 150K 300K 1M 10M 100M 1G Consult factory for UL/CSA approval availability. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF93 Military/Aerospace Multisection Filters Insertion Loss 1212-0502 Insertion Loss (dB) 80 Circuit Schematic 60 1212-0502 40 20 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 Dimensions .055 TYP. (1.40) 1212-0502 .219 TYP. (5.56) .656 (16.41) .418 (10.62) 1.000 (25.4) .500 (12.7) .209 (5.31) .120 TYP. (3.05) .594 ± .031 ± (.78) 1.187 ± .015 (30.15 ± .38) 1.125 (28.58) .125 6-PLCS. (3.18 ± .00) .875 (22.23) 1.250 (31.75) .105 TYP. (2.67) .281 ± .031 (7.14 ± .78) MOUNTING SURFACE .032 (.81) .710 (18.03) .187 (4.75) 1.437 ± .031 (36.50 ± .78) Model Current Rating 1212-0502 10A Voltage Rating 350VDC Dimensions in inches (mm) Temperature Rating -55°C to +125°C DCR max. (ohms) Leakage Current (max.) Cx Value .01 1 mA 5000pF Minimum Insertion Loss (db) Per MIL-STD-220 10M 100M 500M 1G 20 65 70 70 240VAC 60 Hz Consult factory for UL/CSA approval availability. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF94 Military/Aerospace Multisection Filters Secure Communications API's electromagnetic compatibility expertise in the secure communication or “TEMPEST” arena is represented by this group of high performance filters. These units are especially well suited for use in MILSTD-461 applications to reduce conducted emissions. The filters are manufactured with glass sealed terminals and connectors. Filter Schematic A LINE Features ■ ■ ■ ■ Excellent insertion loss profile Available for DC & AC applications up to 400 Hz Available for 3-14 Amp applications Custom systems can be designed to your specific needs LOAD A A C C B B Filter Schematic B LINE LOAD A A C C B B Dimensions 2.50 (63.50) 1.25 (31.75) Insertion Loss 1.75 (44.45) 52-378-002, -004 MIL-STD-220 52-378-002 Insertion Loss (dB) 80 1.500 (38.10) .750 2.50 (19.05) (63.50) #8-32 UNC THD. INSERTS (4.17-32) .350 DEEP, 2 PLACES (8.89) CONNECTOR #8001-14S-7P-A3 MATES WITH MS-3106-14S-7S 60 40 20 0 0.01 0.1 1 10 Frequency (MHz) Dimensions in inches (mm) 100 1000 Minimum Insertion Loss (db) Model Current Rating Voltage Rating Temperature Range DCR max. (ohms) Leakage Current (max.) Schematic 52-378-001 3 Amps 240VAC 60 Hz Line to Line -55°C to 85°C .3 50 mA A 30 60 70 80 80 70 70 52-378-002 5 Amps 240VAC 60 Hz Line to Line -55°C to 85°C .2 50 mA B 24 64 70 80 80 70 70 52-378-004 5 Amps 240VAC 60 Hz Line to Line -55°C to 85°C .2 50 mA A 34 64 70 80 80 70 70 52-378-005 3 Amps 240VAC 60 Hz Line to Line -55°C to 85°C .3 50 mA B 40 70 80 80 80 70 60 50 150 300 1 10 100 1 KHz KHz KHz MHz MHZ MHZ GHz API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF95 Military/Aerospace Multisection Filters Filter Schematic C Insertion Loss LINE 52-387-010, -003 MIL-STD-220 52-409-001 MIL-STD-220 Insertion Loss (dB) 80 60 52-387-010, -003 MIL-STD-220 40 0 0.01 0.1 1 10 Frequency (MHz) A A C C B B Filter Schematic D 52-409-001 MIL-STD-220 20 LOAD LINE 100 LOAD A A C C B B 1000 Filter Schematic E LINE 3 Phase and 400 Hz models available. Please consult the factory. LOAD A A C C B B Dimensions Figure 1 2.50 (63.50) 1.25 (31.75) 2.50 (63.50) 1.25 (31.75) 1.25 (31.75) 1.500 (38.10) .750 2.50 (19.05) (63.50) #8-32 UNC THD. INSERTS (4.17-32) .350 DEEP, 2 PLACES (8.89) Current Rating Figure 2 3.00 (76.20) #8-32 UNC THD. INSERTS (4.17-32) .350 DEEP, 2 PLACES (8.89) Dimensions in inches (mm) Voltage Rating Fig. 52-387-010 1 10 Amps 240VAC 60 Hz Line to Line 52-387-012 1 5 Amps 52-409-001 2 14 Amps 240VAC 60 Hz Line to Line Temperature Range DCR Leakage max. Current (ohms) (max.) CONNECTOR #8001-14S-7P-A3 MATES WITH MS-3106-14S-7S Dimensions in inches (mm) Minimum Insertion Loss (db) 50 150 300 1.0 10 100 1 KHz KHz KHz MHz MHz MHz GHz Sch. Mode common 24 60 70 80 80 70 70 common 34 64 70 80 80 70 70 differential 30 30 70 80 80 – – common 14 30 45 80 80 70 60 -55°C to 85°C .2 50 mA C 240VAC 400 Hz -55°C to 85°C Line to Line .2 5 mA D .04 50 mA E -55°C to 85°C 1.75 (44.45) #8-32 UNC (4.17-32) STUD 1.500 (38.10) .750 2.50 (19.05) (63.50) CONNECTOR #8001-10SL-3PN-FP-A3 MATES WITH MS-3106-10SL-3S Model .625 (15.87) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF96 Military/Aerospace Multisection Filters Secure Communications Features ■ ■ ■ ■ ■ ■ Meets applicable sections of MIL-F-15733 Excellent performance Integral IEC connector Available with integral fused IEC connector and two pole switch Current ratings to 15 Amps Custom designs available Part Numbering System: 760 - A 06 Q Model Current Rating: 3, 6, 10, 15 Amps Electrical Specifications Rated current ranges .................. Rated voltage............................. Operating frequency................... Maximum leakage current @115VAC 60 Hz............ @250VAC 50 Hz............ Test voltage Line-to-Line .................... Line-to-Ground............... 3, 6, 10, 15 Amps 115-250VAC 50-60 Hz Terminal Style: A=.25 Quick Connect C=Wire Leads (4" min.) 1.2 mA 2.5 mA Series: 760; 761 or 762 1450VDC 2250VDC Insertion Loss 760, 761, 762 - 3, 6 Amps 760, 761, 762 - 10, 15 Amps common mode 80 60 Insertion Loss (dB) Insertion Loss (dB) 80 40 20 differential mode 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 common mode 60 40 20 differential mode 0 0.01 0.1 1 10 Frequency (MHz) 100 1000 Common Mode (CM) is tested in a 50 ohm system with all lines tied together on the line and load sides of the filter. Differential Mode (DM) is tested in a 50 ohm system using a 180° phase splitter on both sides of the filter. API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF97 Military/Aerospace Multisection Filters Dimensions - 760 Series .55 (13.97) Current Rating (Amps) Series B C 3, 6 2.25 (57.15) 3.00 (76.20) 1.88 (47.75) 10, 15 5.50 (139.70) 3.15 (88.01) 2.10 (53.34) A 760 1.23 (31.24) Filter Dimensions A .13 (3.30) B 1.332 (33.83) .67 (42.41) 1.312 (33.32) .95 (24.13) C .66 (16.67) TERMINATION STYLE “A” 8-32 Inserts (4 Places) TERMINATION STYLE “C” Dimensions in inches (mm) Dimensions - 761, 762 Series C Series Current Rating (Amps) 761, 762 Filter Dimensions A B C 3, 6 2.55 (64.77) 2.97 (75.43) 1.88 (47.75) 761 10, 15 5.50 (139.70) 3.15 (88.01) 2.10 (53.34) 762 10, 15 5.75 (146.05) 3.15 (88.01) 2.10 (53.34) 3.00 (76.2) 0.20 (5.08) 1.30 (33.02) 1.30 (33.02) 0.20 (5.08) A 0.80 (20.32) 1.875 (47.62) 6-32 UNC-2B (6 Places) 0.80 (20.32) B 3.67 (93.21) .40 (10.16) Switch Omitted in Model 761 3, 6, 10, AMP FRONT PANEL Switch Omitted in Model 761 15 AMP FRONT PANEL .55 (13.97) Dimensions in inches (mm) API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF98 EMI Power Filter Solutions Military and Aerospace API Technologies has a long history of partnering with leading suppliers of the defense industry. Our ability to find solutions to suppress or eliminate electromagnetic interference (EMI) allows us to provide the high reliability filters required for military and aerospace applications. API’s Spectrum Control brand can design your custom filter with a unique mechanical package for those unusual or tight fitting spaces, higher performance filtering and the voltage rating you need to address all of your AC and DC power issues. Communications API’s Spectrum line of power filter solutions can create an agency-approved product that will filter and condition the power to your communications infrastructure equipment, as well as eliminate emissions that can contaminate your distributed AC and DC power. Our custom power filters will incorporate all the components and the filtering in one complete package to save you space, time and money. And as a vertically integrated supplier, API offers global low cost manufacturing which allows us to produce fast prototypes and a quicker time to market. Medical Our many years of experience in providing EMI/RFI solutions has given us the know-how to design products to meet the specific constraints and requirements of the medical industry. Much of the medical equipment used today requires complete suppression of any and all EMI, as well as low-leakage, nonmagnetic properties to prevent negatively affecting surrounding equipment. We will design and build a high reliability, high performance custom power filter to meet your system and all EN requirements. Industrial At API, we do everything from package design and metalworking to EMI filtering to EMC testing, which means a lower cost for you. Our engineers will design and build a custom power filter that will satisfy global EMC regulations, improve speedto-market times, overcome space constraints and withstand harsh environmental conditions. Our plug-and-play designs cover a range of industrial and instrumentation applications that will address any of your power filtering needs with current ratings as high as 500 Amps. ■ Unique mechanical packages addressing specific size and space constraints ■ Customized and fully integrated assemblies incorporating filters, circuit components and connectors ■ Custom applicationspecific filters that meet MIL standard environmental conditions ■ Complex, multifunctional designs that incorporate the filtering and custom circuitry into one easy to install package ■ Designs with selective line filtering, high voltages and agency approvals ■ High reliability filters with low-leakage and nonmagnetic options meet EN testing requirements ■ Vertically integrated solutions include packaging, circular connectors and filter plates ■ Compact, space-saving assembly optimized for the welding industry ■ Ruggedized construction and design flexibility allow our filters to meet demanding environmental and performance requirements API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF99 55DC Link Series Power Film Capacitors API’s Spectrum Control line of high reliability DC link capacitors are ideal for power inverter applications which require superior life under harsh operating conditions, such as electric vehicle power conversions, battery chargers, aircraft power conversion systems and radar systems. Featuring a compact and cost-effective design, DC link capacitors are manufactured from segmented, self-healing metallized polypropylene, resulting in longer life expectancy (+100,000 hrs). With high capacitance density and ripple current capabilities, API’s DC link capacitors are the ideal replacement for electrolytic capacitors. Dimensions M Configuration ø20.8 MM (2 PLCS) Specifications ■ Capacitance tolerance: +/- 10% standard ■ Rated voltage: 900 to 1300 VDC ■ Test voltage between terminals and housing: 5kVDC for 10 sec Series – M6 x 1.0 THREAD 10 MM DEEP MIN. (2 PLCS) ø20.8 MM (2 PLCS) 32 or 45 MM – Voltage 901 = 900 VDC 321 H – Capacitance – = Segmented 321 = 320 µF 112 = 1100 VDC S = Standard 441 = 440 µF (non-segmented) 132 = 1300 VDC ±2.00MM XX Terminal Code – = M12 stud M = M8 External Thread, N = No M12 stud 45mm center-center F = M5 Internal Thread, 45mm center-center S = M6 Internal Thread, 45mm center-center 55DC-901-321-XX 55DC-901-441-XX 55DC-901-561-XX 55DC-901-681-XX 55DC-112-221-XX 55DC-112-281-XX 55DC-112-361-XX 55DC-112-421-XX 55DC-132-161-XX 55DC-132-211-XX 55DC-132-251-XX 55DC-132-321-XX MM 90 +2 -0 MM 6 ±1 MM (2 PLCS) 901 Part Number 16 ±1MM S Configuration 55DC Link Series Part Numbering System 55DC ±2.00MM 16 ±1MM Enclosure/construction: aluminum housing, brass terminals with dry resin, UL 94V-0 encapsulant RoHS compliant 6 ±1 MM (2 PLCS) M12 x 1.75 THREAD M12 x 1.75 THREAD ■ Low ESR and ESL 32 or 45 MM 6 ±1 MM (2 PLCS) H Test voltage between terminals: 150% rated voltage for 10 sec ■ ø20.8 MM (2 PLCS) H ±2.00 MM Operating temperature range: -55°C to +85°C standard (+105°C upon special request) ■ MM 90 +2 -0 MM 20 ±1 MM ■ ■ M5 x 0.8 THREAD 5 MM DEEP MIN. (2 PLCS) 32 or 45 MM M8 x 1.25 THREAD (2 PLCS) Capacitance range: 160 µF to 680 µF standard (others available upon request) ■ F Configuration MM 90 +2 -0 MM M12 x 1.75 THREAD 16 ±1MM MA = M8 External Thread, 32mm center-center FA = M5 Internal Thread, 32mm center-center SA = M6 Internal Thread, 32 mm center-center Rated Voltage (VDC) Capacitance (µF) D Diameter (mm) Height H (mm) Typ ESR (mOhms) Typ ESL (nH) Irms Max. (A) M Weight (kg) 900 900 900 900 1100 1100 1100 1100 1300 1300 1300 1300 320 440 560 680 220 280 360 420 160 210 250 320 90 90 90 90 90 90 90 90 90 90 90 90 97 120 145 170 97 120 145 170 97 120 145 170 2.1 1.8 2.1 2.5 2.5 2.1 1.9 2.3 2.1 1.9 2.5 2.8 50 60 60 80 50 50 60 80 50 50 60 80 60 60 60 60 60 60 60 60 60 60 50 53 0.80 1.00 1.10 1.30 0.90 1.20 1.30 1.30 0.80 1.00 1.20 1.30 API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF101 Audio Film Capacitors Features ■ Multiple dielectric options ■ Metalized film and film/foil construction ■ Wrap and fill, encapsulated and hermetic options ■ Multiple lead configurations, tape and epoxy colors ■ Ability to wind 2-10 layers in a single pass ■ Ability to provide 4-12 micron film ■ Wide range of sized up to 2.000" D x 4.250" L ■ Custom designs available Benefits ■ ■ Application matching for best performance and cost Consistent and repeatable, producing high quality components in smaller package size ■ Improved productivity and increased voltage capability ■ Excellent performance especially for audio applications ■ ■ Tighter tolerance to help meet critical application requirement for capacitance and voltage Hermetic option provides enhanced protection for use in harsh environments Capacitor Type Operating Temperature WVD C WVAC Capacitance Range DF Metallized Film Polyester -55 to +85°C 50 - 600 N/A 0.001 - 15 µF 1.0% Film - Foil Polyester -55 to +85°C 100 - 600 N/A 0.001 - 5 µF 0.5% Metallized Polypropylene -55 to +85°C 200 - 600 504 @ 60 Hz 115 @ 1 kHz 0.001 - 8 µF 0.2% Film-Foil Polypropylene -55 to +85°C 100 - 600 AC Capable TC DA Key Features -6 to +15% 0.6% Low cost -6 to +15% 0.6% Low cost -4 to +2% 0.1% Low DF 0.1% -4 to +2% 0.1% Low DF Metallized Polyphenylene Sulfide -55 to +125°C 50 - 600 25 - 50 kMΩ • µF 240 @ 60 Hz 0.001 - 10 µF 0.3 - 0.5% or 50 - 100 kMΩ, 160 @ 1 kHz w/e less ±2% 0.2% Metallized Polycarbonate* -55 to +125°C 50 - 600 25 - 50 kMΩ • µF 240 @ 60 Hz 0.001 - 10 µF 0.3 - 0.5% or 50 - 100 kMΩ, 160 @ 1 kHz w/e less ±2% 0.2% Metallized Teflon -55 to +170°C 50 - 5000 AC Capable -6 to +15% 0.06% 0.001 - 1 µF 0.0047 10 µF 0.1% Insulation Resistance 10 - 25 kMΩ • µF or 40 - 60 kMΩ, w/e less 50 kMΩ • µF or 100 kMΩ, w/e less 200 kMΩ • µF or 400 kMΩ, w/e less 250 kMΩ • µF or 500 kMΩ, w/e less 100 kMΩ • µF or 200 kMΩ, w/e less High temp capability No voltage derating High temp capability No voltage derating High temp capability Electrical characteristics * Metalized Polycarbonate is being phased out and replace by Metalized Polyphenylene Sulfide API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58 PF102