Film Capacitors Brochure

emi power filters
& film capacitors
EMI Power Filters
& Film Capacitors
find the ideal method to
filter the AC or DC power
entering your system to
prevent radiated or
conducted EMI with our
line of standard power
filters and custom
power solutions
Power Entry Modules, Power Line & 3 Phase Power
Filters are designed in multiple configurations to
cover a range of industrial applications. These
have excellent attenuation for high voltage impulse,
are available in single and dual stage and address
FCC Part 15 regulations while meeting your power
filtering needs… PF5-PF6 & PF16-PF89
Single Line Feed-Through (SLFT)
Power Filters provide superior filtering
in a compact, durable package with single,
dual, and triple feed-throughs available.
These filters are ideal for meeting broad
frequency applications with a bolt-in style
for easy installation… PF7-PF14
Military/Aerospace Multisection
Filters provide excellent EMI filtering for
demanding high reliability applications.
We offer standard filters, as well
as custom designed mechanical
packages for unusual or tight fitting
spaces and higher performance
filtering and expanded voltage
ratings… PF91-PF98
EMI Power Filter Solutions will
lower your costs and reduce your time
to market while providing your system with
protection from radiated or conducted EMI.
Our comprehensive consulting, diagnostic
testing and world class manufacturing
allows us to meet your design/project
parameters… PF99
Power Film Capacitors deliver high
reliability, low inductance, low ESR and
low DF with a high peak withstanding
voltage. These ruggedized capacitors
come in a wide range of dielectrics,
various geometries, a variety of
terminations, multiple sizes and
electrical ratings of 250-15KVDC
typical, ripple currents up to 400
Arms and 150°C operation… PF100
Audio Film Capacitors with multiple dielectrics
in metalized film and film/foil construction. High
quality capacitors specially designed for audio
applications… PF102
EMI Filter Expertise
We differentiate ourselves from typical
filter suppliers by offering our customers
an integrated approach to EMC problem
solving through consulting, diagnostic
testing, design and manufacturing.
■ In-house test facilities to provide a total
solution for your compliance issues –
anechoic chamber, shielded room
and NARTE certified engineers ready
to test for European emission and
immunity regulations, FCC Part 15
and MIL standards
■
■
■
■
Global manufacturing and design support with agency
approved products available
Engineering expertise and vertical integration reduce
your time to market and save you money
High reliability products with low leakage
and nonmagnetic options available
Available to meet MIL-PRF-15733
and MIL-STD-461 standards
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF2
Application Guidelines
Need for EMI suppression
Global regulatory agencies have established limits to
the amount of noise that man-made electronic devices
can radiate or conduct. These regulations have gained
greater importance as the world’s electronic population
intensifies and the proximity of electronic devices
becomes closer.
Power Filter Installation
EMI can propagate through two basic
avenues: Conducted and Radiated
Conducted refers to events where the EMI energy
flowsthrough power lines, data cables and other wiring
that carries functional data or power.
Radiated refers to energy that is propagated by
magnetic or electric fields, which originate from other
electronic or electrical systems.
INCORRECT
CORRECT
CABINET
POWER
INPUT
DENOTES
COUPLING
FROM NOISY
CIRCUITS
BACK TO
LINE
CABINET
DENOTES
COUPLING
FROM NOISY
CIRCUITS
BACK TO
LINE
POWER
INPUT
Interference types
There are two modes of conducted noise: differential
mode (symmetrical or normal mode) and common mode
(asymmetrical mode).
Differential mode interference signals are present on
one side of the line, referenced to the other. The currents
flow along one phase and return along another phase.
Common mode interference signals are present on both
sides of the line referenced to ground. The current flows
from the source to ground along the ground path and
returns along the phases.
Sources of EMI
Electromagnetic interference can occur naturally
or through electronic sources. Lightning discharges,
precipitation, sand and dust storms, and cosmic noise
are sources of natural EMI.
EMI generated from power electrical products cause
the most concern. These man-made sources, such as
power lines, rotating machinery, power supplies and
electronic transmission devices, all have their own
signatures and noise pollution.
EMI filters, insertion loss
and attenuation
Power line EMI filters are designed to attenuate (or
reduce) all radio frequency emissions or energy that is
above the applicable EMC specification. Most power line
EMI filters utilize inductor/capacitor “low pass” component
configurations that pass all DC or low frequency AC
necessary energy and attenuate (suppress) higher
frequencies containing noise or unwanted energy.
LINE
FILTER
CLEAN
LINE
LINE FILTER
To insure a customer’s “in system” unit to unit attenuation
uniformity of power line filters, an insertion loss production
line test is performed by API Technologies.
Each of the specific frequencies is measured using
RF test equipment and the “reference signal level” of
each frequency is stored. Some systems sweep the entire
frequency range and store this “reference signal level”.
The filter to be measured, tested, or evaluated is then
“inserted” between the generator and receiver that
established the stored “reference signal level” on the
RF test analyzer.
The measured difference without a filter (“the reference
signal level”) and with the filter “inserted” into the RF test
equipment/analyzer is defined as insertion loss. The unit
of measure for insertion loss is the decibel (dB). As noted
on most curves in this bulletin, as frequency increases,
the higher the insertion loss or dB value. The plot of
frequency versus dB value establishes the typical
insertion loss curve.
Installation Criteria
Proper installation of a filter network is critical to achieving
successful filtering of electromagnetic interference. API
recommends that power line filters be installed where
the power line enters the equipment. The filter acts as
a barrier between polluted energy and clean energy
going into your equipment. It is important that the filter
is connected to an effective ground plane and where
proximity does not couple radiated noise to the clean lines.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF3
Measurement Guidelines
API Technologies has the capability to perform a wide
range of tests for EMI filters. Unique custom testing
systems designed by Spectrum assure the accuracy
required in today’s demanding environments. Testing
is performed by employing a 50 ohm source and load
impedance per MIL-STD-220. The individual filter
performance is stated in terms of insertion loss. Overall
attenuation reflects the filter’s interaction within the
system. Individual filter performance may differ from
system to system and each application should be verified
through system testing. Examples of various testing
abilities and configurations are outlined below.
Differential (Normal or Symmetrical)
Mode Insertion Loss
Differential mode noise is caused by non-sinusoidal
conduction of rectifiers and other switching devices
creating harmonic distortion.
This noise is predominant from the power frequency
to approximately 10 MHz. Since it follows conventional
current flow, it is considered to be of the same magnitude
but opposite phase of the other line. Spectrum measures
differential mode insertion loss in a 50 ohm system with
Balun transformers as shown.
Leakage Current
Leakage is a measurement of reactive current
(capacitance) to ground per line. Spectrum uses the
following test setup for leakage current measurement.
TIES TO CHASSIS
OF DEVICE
DEVICE
UNDER
TEST
1
AC
SOURCE
2
0.15 µFD
1 NEUTRAL TEST
2 HIGH TEST
1.5 KΩ
v
IN ACCORDANCE WITH U.L. 1283 METHOD
AC Voltage Drop
AC voltage drop is defined as E in - E out = AC
voltage drop.
Spectrum Control uses the following circuit for AC voltage
drop testing:
A
DUT
(FILTER)
E1
BALUN
INSULTATED TABLE
E2
BALUN
FILTER
ØA
50Ω
FILTER
ØB
SIGNAL
GENERATOR
50Ω
RECEIVER
Common (Asymmetrical)
Mode Insertion Loss
E VD
Since common mode insertion loss is of the same
phase as the opposite line, they may not be of the
same magnitude, depending on the end system circuitry.
Spectrum Control tests common mode insertion loss on
each line in a 50 ohm system as shown.
50Ω
LINE
DUT
(FILTER)
A
RS
LINE
50Ω
FILTER
NEUT
DC Voltage Drop
DC voltage drop is performed on each line individually.
This test provides the total DC voltage drop for that line
of the filter. The following circuit is used in testing:
FILTER
ØC
RECEIVER
NEUT
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF4
Power Entry Modules, Power Line Filters &
3 Phase Power Filters Part Numbering System
Part Numbering System
Example: 12-PMB-025-5-A
Part number 12-PMB-025-5A represents a power line filter
with threaded studs, current rated for 25 Amps and with a
leakage current of 0.50 mA.
12
-
PMB
-
Product Line Series
Product Style
10 = Filtered IEC Inlets
11 = Printed Circuit Board
Mount
12 = Power Line Filters
13 = Three Phase Power
Line Filters
14 = Fused or Switched
& Fused Power Entry
Filters (250V)
15 = Switched & Dual Fused
16 = Single Phase (250V)
BBF = 3 Phase, terminal block
connection
BFF = Bolt-in fused filter
BPF = Bolt-in IEC w/Fast-on
rear terminals
BPL = Bolt-in IEC w/wire lead
termination
BSF = Bolt-in switched & fused
CCL = Cylindrical, capacitive
inputs w/Fast-ons
CLF = Cylindrical, inductive
inputs w/wire leads
MMB = Multiple stage filtering
w/threading studs
MMF = Multiple stage filtering
w/Fast-on terminal
MPC = Miniature PCB mountable
PDB = 3 Phase, delta
w/threaded studs
PDF = 3 Phase, delta w/Fast-ons
PDL = 3 Phase, delta w/wire leads
PMB = Power line filter
w/threaded studs
PMF = Power line filter
w/Fast-ons
PML = Power line filter
w/wire leads
PWB = 3 Phase, wye
w/threaded studs
PWE = 3 Phase, wye w/busbar
PWF = 3 Phase, wye w/Fast-ons
PWL = 3 Phase, wye
w/wire leads
025
Current Rating
001
002
003
005
006
010
015
016
020
025
030
035
050
080
100
150
160
200
300
400
500
600
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1.0 Amp
2.0 Amps
3.0 Amps
5.0 Amps
6.0 Amps
10 Amps
15 Amps
16 Amps
20 Amps
25 Amps
30 Amps
35 Amps
50 Amps
80 Amps
100 Amps
150 Amps
16.0 Amps
200 Amps
300 Amps
400 Amps
500 Amps
600 Amps
-
5
-
A
Leakage Current
(Y Cap)
Outline Drawing/
Case Style
250 VAC
125VAC
0 = 0.075 mA DC = DC
1 = 0.01 mA
2 = 0.20 mA
3 = 0.35 mA
4 = 0.10mA
5 = 0.50 mA
6 = 0.60 mA
7 = 0.70 mA
8 = 1.0 mA
9 = 3.0 mA
10 = 2.0 mA
11 = 1.5 mA
12 = 4.5 mA
13 = 9.0 mA
14 = 20.0 mA
15 = 15.0 mA
17 = 33.0 mA
18 = 71.5 mA
DC = DC
1 Select case style from
following
* Cylindrical
* Power line w/Fast-on
* Power line w/threaded
studs
* Power line w/wire leads
* PCB mount
* Large case 3 Phase delta
* Large case 3 Phase wye
* IEC Inlet
2 Refer to drawing list per
selected case style
3 Letter at the end of the
part is found in the case
style drawing list:
A, B, C, D, E, F, etc.
* Note: Not all series offer the product style, rating and leakage current
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF5
Power Entry Modules, Power Line Filters &
3 Phase Power Filters Part Numbering System
Part Numbering System
Example: 60-BPR-060-5-4
Part number 60-BPR-060-5-4 represents a power entry module,
bolt-in style with fast-on terminals, a current rating of 6 Amps,
leakage current of 0.50 mA and capacitance of 0.047 µF.
60
-
BPR
-
Product Line Series
Product Style
60 = Power Entry Modules
61 = Mini PCB Power
Filters
62 = Power Line Filters
63 = Three Phase Power
Line Filters
64 = Fused or Switched
& Fused Power Entry
Filters (250V)
65 = Fused or Switched
& Fused Power Entry
Filters (125V)
66 = Fused or Switched
& Fused Low
Leakage Power Entry
Filters (250V)
67 = Fused or Switched
& Fused Low
Leakage Power Entry
Filters (125V)
68 = Switched & Dual
Fused Power
Entry Filters
69 = Dual Fused Only
or Dual Switched
Only Power
Entry Filters
AFL = Appliance filter w/
inductive input
AFC = Appliance filter w/
capacitive input
ARL = AFL plus bleeder resistor
BFF = Fused filter w/
Fast-on terminals
BFS = Fused filter w/solder
lug terminals
BHP = High frequency bolt-in
for PCB
BHS = High frequency bolt-in
w/solder lugs
BPF = Bolt-In right angle
terminals
BPL = Bolt-in w/wire leads
BPP = Bolt-in PCB mount
BPR = Bolt-in w/Fast-on tab
terminals
BPS = Bolt-in w/ solder lug
terminals
BSF = Bolt-in switched & fused
MMF = Metal case w/fast-on
tabs
MPC = Miniature printed circuit
board
PMB = Metal case w/bolt-on
terminals
PMF = Metal case w/Fast-on
tabs
PML = Metal case w/wire leads
PPF = Plastic case w/Fast-on tabs
PQF = Plastic case w/Fast-on tabs
PRF = Plastic case w/Fast-on tabs
SOF = Switched filter w/
Fast-on tabs
SOS = Switched filter w/
solder tabs
SPL = Snap-in w/wire leads
SPR = Snap-in w/Fast-on
terminals
SPS = Snap-in w/solder lug
terminals
SSF = Snap-in switched
& fused
ARC = AFC plus bleeder resistor
060
-
Current Rating
010
015
016
020
030
040
050
060
080
100
150
160
200
300
400
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
1.0 Amps
1.5 Amps
1.6 Amps
2.0 Amps
3.0 Amps
4.0 Amps
5.0 Amps
6.0 Amps
8.0 Amps
10.0 Amps
15.0 Amps
16.0 Amps
20.0 Amps
30.0 Amps
40.0 Amps
5
-
Leakage Current (Y Cap)
0
1
2
3
4
5
6
7
8
9
250 VAC
= 0.075 mA
= 0.01 mA
= 0.20 mA
= 0.35 mA
= 0.10 mA
= 0.50 mA
= 0.60 mA
= 0.70 mA
= 1.00 mA
= 3.00 mA
0
1
3
4
5
6
7
8
9
125VAC
= 0.035 mA
= 0.005 mA
= 0.35 mA
= 0.05 mA
= 0.50 mA
= 0.60 mA
= 0.70 mA
= 1.00 mA
= 3.00 mA
4
Capacitance (X Cap)
0
1
2
3
4
5
6
01
02
04
06
10
11
12
13
14
16
21
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
none
0.01µF
0.022µF
0.033µF
0.047µF
0.050µF
0.068µF
2 x 0.01µF
0.10µF & 0.22µF
2 x 0.22µF
2 x 0.4µF & 0.22µF
0.15µF
0.10µF
0.22µF
0.33µF
0.47µF
0.22µF & 2 x 0.33µF
1.00µF
* Note: Not all series offer the product style, rating and leakage current
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF6
High Current
DC Single Line
Feed-through Series
Features
■
■
■
■
■
■
■
■
■
Voltage rating of 130VDC
C configuration with Class Y4 capacitors
Current rating up to 300 Amps
Operating temperature range: -40°C to +85°C
Excellent filtering in compact package
Bolt-in style with D-shaped bushing for easy installation
Low cost EMI solution
Design flexibility
UL and Semko approved
Applications
■
■
■
■
■
■
Telecommunications (cellular base stations,
telephone switching racks, etc.)
Power supplies
Medical equipment
C.O.T.S. (Commercial-Off-The-Shelf) Military
Industrial equipment controls
Data transmission equipment
Specifications
Part
Number
52F226-011-10
52F226-011-16
52F226-011-32
52F226-011-63
52F226-011-100
52F226-011-200
52F226-011-250
52F226-011-300
52F226-021-16
52F226-021-32
52F226-021-63
52F226-021-100
52F226-021-200
52F226-021-250
52F226-021-300
52F226-031-16
52F226-031-32
52F226-031-63
52F226-031-100
52F226-031-200
52F226-031-250
52F226-031-300
52F226-041-16
52F226-041-32
52F226-041-63
52F226-041-100
52F226-041-200
Rated
Current
10A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
Min.
Cap.
.01MHz
10nF
.10MHz
Minimum Insertion Loss (db)*
1MHz
10MHz
100MHz
1000MHz
–
4
21
41
60
2
15
34
53
74
100nF
5
21
40
60
85
47nF
2
15
34
53
74
100nF
5
21
40
60
85
47nF
–
470nF
2
16
33
52
75
90
100nF
–
5
21
40
60
85
470nF
2
16
33
52
75
1000nF
6
20
40
60
85
470nF
2
16
33
52
75
1000nF
4700nF
6
15
20
35
40
54
60
74
85
90
90
* Optimum performance with proper installation
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF7
High Current
DC Single Line
Feed-through Series
F
B
E
WORKORDER NO.
C
D
DATE CODE
SINGLE "D"
MOUNTING FLAT
.025 (.64) SHOULDER
A
Dimensions
Part Number
52F226-011-10
52F226-011-16
52F226-011-32
52F226-011-63
52F226-011-100
52F226-011-200
52F226-011-250
52F226-011-300
52F226-021-16
52F226-021-32
52F226-021-63
52F226-021-100
52F226-021-200
52F226-021-250
52F226-021-300
52F226-031-16
52F226-031-32
52F226-031-63
52F226-031-100
52F226-031-200
52F226-031-250
52F226-031-300
52F226-041-16
52F226-041-32
52F226-041-63
52F226-041-100
52F226-041-200
A
B
C
D
E
2.24 (57)
0.39 (10)
0.51 (13)
0.56 (14.29)
0.63 (16)
2.48 (63)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.06 (27)
1.25 (31.75)
1.02 (26)
1.26 (32)
1.57 (40)
1.57 (40)
2 (50.80)
1.81 (46)
5.83 (148)
0.75 (19)
F
2.95 (75)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.06 (27)
1.25 (31.75)
1.02 (26)
1.26 (32)
1.57 (40)
1.57 (40)
2 (50.80)
1.81 (46)
6.30 (160)
0.75 (19)
0.71 (18)
1.18 (30)
1.30 (33)
1.65 (42)
1.18 (30)
1.30 (33)
2.13 (54)
2.95 (75)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.79 (147)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.30 (33)
1.97 (50)
2 (50.80)
1.81 (46)
2.83 (72)
7.01 (178)
3.23 (82)
3.98 (101)
5.24 (133)
6.50 (165)
0.75 (19)
0.63 (16)
0.75 (19)
1.06 (27)
1.57 (40)
1.06 (27)
1.57 (40)
1.25 (31.75)
1.5 (38.10)
2 (50.80)
0.71 (18)
1.02 (26)
1.26 (32)
1.57 (40)
1.18 (30)
1.30 (33)
1.97 (50)
2.68 (68)
Dimensions in inches (mm)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF8
High Current
DC Single Line
Pi Series
Features
■
■
■
■
■
■
■
Voltage rating of 130VDC
Pi configuration with Class Y4 capacitors
Current rating up to 200 Amps
Excellent filtering in compact package
Bolt-in style with D-shaped bushing for easy installation
Low cost EMI solution
UL and Semko approved
Applications
■
■
■
■
■
■
Telecommunications (cellular base stations,
telephone switching racks, etc.)
Power supplies
Medical equipment
C.O.T.S. (Commercial-Off-The-Shelf) Military
Industrial equipment controls
Data transmission equipment
Circuit Diagram
Specifications
Part
Number
Standard Performance
52F226-020-10
52F226-020-16
52F226-020-32
52F226-020-63
52F226-020-100
52F226-020-200
High Performance
52F226-029-10
52F226-029-16
52F226-029-32
52F226-029-63
52F226-029-100
52F226-029-200
Rated
Current
10A
16A
32A
63A
100A
200A
10A
16A
32A
63A
100A
200A
Min.
Cap. (2X)
10nF
.01MHz
–
.10MHz
Minimum Insertion Loss (db) *
1MHz
10MHz
100MHz
0.5
8
10
27
23
35
23
67
70
60
470nF
4
7
2
8
21
23
100nF
–
8
25
75
470nF
1000nF
4700nF
4
8
20
21
26
40
35
57
85
70
73
90
100nF
30
1000MHz
70
50
90
90
90
90
* Optimum performance with proper installation
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF9
High Current
DC Single Line
Pi Series
A
B
F
E
C
D
SINGLE "D"
MOUNTING FLAT
DATE CODE
WORKORDER NO.
.025 (.64) SHOULDER
Dimensions
Part Number
Standard Performance
52F226-020-10
52F226-020-16
52F226-020-32
52F226-020-63
52F226-020-100
52F226-020-200
High Performance
52F226-029-10
52F226-029-16
52F226-029-32
52F226-029-63
52F226-029-100
52F226-029-200
A
B
C
D
0.47 (12)
0.67 (17)
0.75 (19.05)
0.55 (14)
0.63 (16)
0.75 (19)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.50 (38.10)
3.54 (90)
3.86 (98)
6.30 (160)
7.24 (184)
8.23 (209)
1.06 (27)
5.12 (130)
5.47 (139)
6.81 (173)
8.98 (228)
11 (279)
0.47 (12)
0.63 (16)
0.75 (19)
0.67 (17)
1.06 (27)
1.57 (40)
0.75 (19.05)
1.25 (31.75)
1.50 (38.10)
2 (50.80)
E
F
0.63 (16)
1.93 (49)
0.71 (18)
2.09 (53)
1.02 (26)
1.26 (32)
1.57 (40)
3.70 (94)
4.09 (104)
4.41 (112)
0.63 (16)
3.50 (89)
0.71 (18)
3.70 (94)
1.02 (26)
1.26 (32)
1.57 (40)
4.13 (105)
5.71 (145)
7.17 (182)
Dimensions in inches (mm)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF10
High Current
AC Single Line
Feed-through Series
Features
■
■
■
■
■
■
■
■
Voltage rating of 250VAC
C configuration with Class Y2 capacitors
Current rating up to 300 Amps
Excellent filtering in compact package
Bolt-in style with D-shaped bushing for easy installation
Low cost EMI solution
Design flexibility
UL and Semko approvals pending
Applications
■
■
■
■
■
■
Telecommunications (cellular base stations,
telephone switching racks, etc.)
Power supplies
Medical equipment
C.O.T.S. (Commercial-Off-The-Shelf) Military
Industrial equipment controls
Data transmission equipment
Specifications
Part
Number
52F226-016-10
52F226-016-16
52F226-016-32
52F226-016-63
52F226-016-100
52F226-016-200
52F226-016-250
52F226-016-300
52F226-026-10
52F226-026-16
52F226-026-32
52F226-026-63
52F226-026-100
52F226-026-200
52F226-026-250
52F226-026-300
52F226-036-16
52F226-036-32
52F226-036-63
52F226-036-100
52F226-036-200
52F226-036-250
52F226-036-300
52F226-046-16
52F226-046-32
52F226-046-63
52F226-046-100
52F226-046-200
52F226-046-250
52F226-046-300
Rated
Current
Min.
Cap.
10A
16A
32A
63A
100A
200A
250A
300A
10A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
16A
32A
63A
100A
200A
250A
300A
2.2nF
.01MHz
.10MHz
Minimum Insertion Loss (db) *
1MHz
10MHz
100MHz
1000MHz
-
9
30
45
4.7nF
–
2
15
34
54
10nF
47nF
2
4
15
21
34
41
53
60
74
100nF
5
21
40
60
85
2
15
34
54
4
21
41
60
4.7nF
10nF
–
–
47nF
100nF
2
5
15
21
34
40
53
60
74
85
220nF
10
27
47
67
90
47nF
33nF
100nF
220nF
2
3
5
10
15
16
21
27
34
35
40
47
16
33
52
75
2
5
2
10
16
21
15
27
33
40
34
47
52
60
53
67
75
6
20
40
60
85
470nF
100nF
47nF
220nF
470nF
1000nF
2
–
53
60
67
74
90
85
90
85
74
90
* Optimum performance with proper installation
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF11
High Current
AC Single Line
Feed-through Series
B
F
WORKORDER NO.
C
E
D
SINGLE "D"
MOUNTING FLAT
DATE CODE
.025 (.64) SHOULDER
A
Dimensions
Part Number
52F226-016-10
52F226-016-16
52F226-016-32
52F226-016-63
52F226-016-100
52F226-016-200
52F226-016-250
52F226-016-300
52F226-026-10
52F226-026-16
52F226-026-32
52F226-026-63
52F226-026-100
52F226-026-200
52F226-026-250
52F226-026-300
52F226-036-16
52F226-036-32
52F226-036-63
52F226-036-100
52F226-036-200
52F226-036-250
52F226-036-300
52F226-046-16
52F226-046-32
52F226-046-63
52F226-046-100
52F226-046-200
52F226-046-250
52F226-046-300
A
B
C
D
E
2.24 (57)
0.39 (10)
0.51 (13)
0.56 (14.29)
0.63 (16)
2.48 (63)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.57 (40)
2 (50.80)
1.81 (46)
5.83 (148)
0.75 (19)
1.06 (27)
F
2.24 (57)
0.39 (10)
0.51 (13)
0.56 (14.29)
0.63 (16)
2.48 (63)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.45 (113)
5.12 (130)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.57 (40)
2 (50.80)
1.81 (46)
5.83 (148)
0.75 (19)
1.06 (27)
0.71 (18)
1.18 (30)
1.30 (33)
1.65 (42)
0.71 (18)
1.18 (30)
1.30 (33)
1.65 (42)
2.95 (75)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.71 (18)
3.78 (96)
4.57 (116)
5.79 (147)
0.55 (14)
0.87 (22)
1.06 (27)
1 (25.40)
1.02 (26)
1.26 (32)
1.57 (40)
1.30 (33)
1.97 (50)
2 (50.80)
1.81 (46)
2.13 (54)
0.87 (22)
0.67 (17)
1 (25.40)
0.71 (18)
1.18 (30)
1.06 (27)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
1.57 (40)
1.30 (33)
0.75 (19)
6.30 (160)
3.03 (77)
2.95 (75)
4.45 (113)
5.24 (133)
5.79 (147)
6.30 (160)
0.55 (14)
0.47 (12)
0.63 (16)
0.75 (19)
1.57 (40)
1.57 (40)
1.5 (38.10)
2 (50.80)
1.81 (46)
1.18 (30)
1.97 (50)
2.13 (54)
Dimensions in inches (mm)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF12
High Current
AC Single Line
Pi Series
Features
■
■
■
■
■
■
■
■
Voltage rating of 250VAC
Pi configuration with Class Y2 capacitors
Current rating up to 300 Amps
Excellent filtering in compact package
Bolt-in style with D-shaped bushing for easy installation
Low cost EMI solution
Design flexibility
UL and Semko approvals pending
Circuit Diagram
Applications
■
■
■
■
■
■
Telecommunications (cellular base stations,
telephone switching racks, etc.)
Power supplies
Medical equipment
C.O.T.S. (Commercial-Off-The-Shelf) Military
Industrial equipment controls
Data transmission equipment
Specifications
Part
Number
Standard Performance
52F226-037-10
52F226-037-16
52F226-037-32
52F226-037-63
52F226-037-100
52F226-037-200
52F226-037-250
52F226-037-300
High Performance
52F226-019-10
52F226-019-16
52F226-019-32
52F226-019-63
52F226-019-100
52F226-019-200
52F226-019-250
52F226-019-300
Rated
Current
Min.
Cap. (2X)
10A
16A
32A
63A
100A
200A
250A
300A
4.7nF
10A
16A
32A
63A
100A
200A
250A
300A
10nF
.01MHz
–
47nF
100nF
1
10nF
22nF
–
.10MHz
Minimum Insertion Loss (db) *
1MHz
10MHz
100MHz
–
4
19
77
1
8
22
50
4
8
21
25
52
73
80
9
26
75
1
9
30
3
15
47
27
39
75
150nF
1
12
470nF
4
21
57
85
1000MHz
90
90
80
90
90
* Optimum performance with proper installation
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF13
High Current
AC Single Line
Pi Series
A
B
F
E
C
D
SINGLE "D"
MOUNTING FLAT
DATE CODE
WORKORDER NO.
.025 (.64) SHOULDER
Dimensions
Part Number
Standard Performance
52F226-037-10
52F226-037-16
52F226-037-32
52F226-037-63
52F226-037-100
52F226-037-200
52F226-037-250
52F226-037-300
High Performance
52F226-019-10
52F226-019-16
52F226-019-32
52F226-019-63
52F226-019-100
52F226-019-200
52F226-019-250
52F226-019-300
A
B
C
D
E
F
0.47 (12)
0.67 (17)
0.75 (19.05)
0.63 (16)
0.71 (18)
2.24 (57)
2.40 (61)
0.55 (14)
0.63 (16)
0.87 (22)
1 (25.40)
1.25 (31.75)
1.02 (26)
1.26 (32)
1.57 (40)
3.7 (94)
4.09 (104)
4.41 (112)
1.81 (46)
3.66 (93)
3.86 (98)
4.17 (106)
6.30 (160)
7.24 (184)
8.23 (209)
7.87 (200)
0.75 (19)
1.06 (27)
1.57 (40)
1.5 (38.10)
4.21 (107)
0.47 (12)
0.67 (17)
0.75 (19.05)
0.63 (16)
2.6 (66)
4.57 (116)
0.55 (14)
0.87 (22)
1 (25.40)
0.71 (18)
2.72 (69)
6.81 (173)
8.98 (228)
9.57 (243)
0.63 (16)
1.06 (27)
1.25 (31.75)
1.5 (38.10)
1.02 (26)
1.26 (32)
4.13 (105)
5.71 (145)
5.75 (146)
1.57 (40)
2 (50.80)
1.57 (40)
10.5 (267)
0.75 (19)
6.30 (160)
Dimensions in inches (mm)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF14
High Current
Filtered Terminal Blocks
Features
■
■
■
■
Ideal for high current applications
Design flexibility
Available in 2 x 2 through 2 x 6 positions
UL approved
Specifications
Applications
ELECTRICAL
Voltage rating:
Capacitance:
Telecommunications switching networks
■ Cellular base stations
■ Power supplies
■ UPS
■ Instrumentation
■ High reliability radar and transmission systems
■ Industrial controls
■ Power distribution
■
4.600 (116.8)
Dielectric
withstanding voltage: 1000VDC for 1 minute
Current rating:
60 Amps max per terminal
Typical Insertion Loss — dB:
In 50 Ohm Circuit
1
5
10
50
8-32 THREADED
INSERTS (4X)
1.625
(41.3)
.65 MIN (16.5) (6X)
1.10 (27.9)
.80 MIN (20.3)
.75 (19.0) (5X)
.172 (4.3) (4X)
MHz......... 36
MHz......... 33
MHz......... 25
MHz......... 25
US .200: (5.08 mm)
AWG #12-26
Steel, zinc chromate plate
.05" (1.30 mm) contact hole
UL rated 94VO polyamide
2.5 in.-lbs. max. (28 Ncm)
Brass, tin-plated
* For filter elements with additional capacitance values,
consult factory.
PANEL CUTOUT
4.6 (116.8)
5.0 (127)
5.0 (127)
5.6 (142.2)
52-1013-102
70
100
160
200
1.685 2.025
(42.8) (51.4)
2.625 2.025 .75 (19.0)
(66.7) (51.4)
Part
Number
MHz....... 8
MHz....... 24
MHz....... 32
MHz....... 38
MECHANICAL
Center spacing:
Wire size:
Screw material:
Recommended PCB
hole diameter:
Molded material:
Tightening torque:
Terminal:
R.125 (3.2) (4X)
1.15 (29.1)
100 VDC per terminal
.015µF* +80% / -20% per cap
.030µF +80% / -20% per pair
Number of
Terminals
in.
2x2
2.60
A
(mm)
in.
66.04
2.00
B
(mm)
in.
50.80
1.66
C
(mm)
42.16
52-1013-103
2x3
3.35
85.09
2.75
69.85
2.41
61.21
52-1013-104
2x4
4.10
104.14
3.50
88.90
3.16
80.25
52-1013-105
2x5
4.85
123.19
4.25
107.95
3.91
99.31
52-1013-106
2x6
5.60
142.24
5.00
127.00
4.66
118.36
Dimensions in inches (mm)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF15
Power Entry Modules
Bolt-in Rear Terminals
60-BPR & BPS Series
Features
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Solder lug and Fast-on tab terminals available
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF17)
UL approved low leakage version also available
Applications
■
■
■
■
Circuit Diagram
1
CX
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
L1
CY
2
3
E
4
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-XXX-010-3-2
60-XXX-010-3-4
60-XXX-010-5-2
250VAC
60-XXX-020-3-2
60-XXX-020-5-2
250VAC
60-XXX-030-3-2
60-XXX-030-3-4
250VAC
60-XXX-060-3-2
60-XXX-060-5-2
250VAC
60-XXX-100-5-2
60-BPR-150-3-11
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
6A
60-XXX-060-5-4
60-XXX-100-3-2
0.35mA
3A
60-XXX-030-5-4
60-XXX-060-3-4
Capacitance
2A
60-XXX-020-5-4
60-XXX-030-5-2
CY
1A
60-XXX-010-5-4
60-XXX-020-3-4
Leakage Current
(Max.)
250VAC
10A
250VAC
15A
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
Inductance
(L1)
Temperature
Rise (Max.)
6.0mH
30°C
2.4mH
30°C
1.2mH
30°C
0.53mH
45°C
.022uF ± 20%
0.26mH
45°C
.1uF ± 20%
0.15mH
45°C
CX
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
* Substitute BPR or BPS for XXX
BPS - Solder lug terminals
BPR - Fast-on tab terminals
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF16
Power Entry Modules
Bolt-in Rear Terminals
60-BPR & BPS Series
Temperature Characteristics
0.837
(21.3)
120
Current (%)
100
80
.944 (24)
60
1.967
(50)
20
30
40
50
60
70
Ambient Temperature (°C)
80
* General tolerance
± .012 (0.3)
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
Insertion Loss (dB)
Insertion Loss (dB)
70
50
60-BPX-020-5-X
60-BPX-030-5-X
20
60-BPX-010-5-X
60
50
40
60-BPX-020-5-X
30
60-BPX-030-5-X
20
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
70
70
Insertion Loss (dB)
80
60-BPX-060-5-X
50
40
30
60-BPX-100-5-X
20
10
20
50
60-BPX-060-X-4
60
50
60-BPX-060-X-2
40
60-BPX-100-X-2
30
20
10
10
0
0.1
5
60-BPX-060;-100
60-BPX-060;-100
80
60
2
Frequency (MHz)
Frequency (MHz)
Insertion Loss (dB)
50Ω
Level
Meter
50Ω
80
60-BPX-010-5-X
30
50Ω
60-BPX-010;-020;-030
60-BPX-010;-020;-030
80
40
1.10
(28)
90
Common Mode
60
.157
(4)
1.181
(30)
1.573
(40)
20
70
1.476 (37.5)
(2x) .142
(3.6)
40
0
2.263 (57.5)
.252
(6.4)
.846
(21.5)
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF17
Power Entry Modules
Bolt-in Right Angle Terminals
60-BPF Series
Features
■
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
PCB mounting types available (see page PF46)
Length under tab is shortened for small spaces
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF19)
UL approved low leakage version also available
Applications
■
■
■
■
Circuit Diagram
1
CX
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
L1
CY
2
3
E
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPF-010-3-2
60-BPF-010-3-4
60-BPF-010-5-2
250VAC
60-BPF-020-3-2
60-BPF-020-5-2
250VAC
60-BPF-030-3-2
60-BPF-030-5-2
250VAC
60-BPF-060-3-2
60-BPF-060-5-2
250VAC
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
3A
60-BPF-030-5-4
60-BPF-060-3-4
Capacitance
2A
60-BPF-020-5-4
60-BPF-030-3-4
CY
1A
60-BPF-010-5-4
60-BPF-020-3-4
Leakage Current
(Max.)
6A
60-BPF-060-5-4
CX
Inductance
(L1)
Temperature
Rise (Max.)
6.0mH
30°C
2.4mH
30°C
1.2mH
30°C
0.53mH
45°C
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF18
Power Entry Modules
Bolt-in Right Angle Terminals
60-BPF Series
Temperature Characteristics
120
1.463 (37.2)
1.967 (50)
60-BPF
Fast-on
Terminals
1.317
(33.5)
1.573 (40)
.885
(22.5)
Current (%)
100
2- .142
(3.6)
80
.047 (1.2)
.232 (5.9)
1.180 (30)
60
.024
(.6)
.5
R4
.865
(22)
2- .142
(3.6)
1.573 (40)
40
.991
(25.2)
.590 (15)
* General
tolerance
± .012 (.3)
.142
.059 (3.6)
(1.5)
.031 (.8)
1.070
(27.2)
.779 1.180
(19.8) (30)
.708
(18)
Panel cutout dimensions
mounts from backside
20
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
60-BPF-010;-020
70
Insertion Loss (dB)
Insertion Loss (dB)
80
60-BPF-010-3-X
60
50
60-BPF-020-3-X
40
30
20
10
0
0.1
60
60-BPF-010-X-4
50
40
30
60-BPF-020-X-4
20
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
70
70
Insertion Loss (dB)
Insertion Loss (dB)
80
60-BPF-030-3-X
50
5
10
20
50
20
50
60-BPF-030;-060
60-BPF-030;-060
60
2
Frequency (MHz)
80
40
60-BPF-060-3-X
30
20
60
50
40
30
60-BPF-030-X-4
60-BPF-060-X-4
20
10
10
0
0.1
50Ω
Level
Meter
50Ω
60-BPF-010;-020
80
70
50Ω
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF19
Power Entry Modules
High Frequency Attenuation
60-BHS Series
Features
■
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
PCB mounting types available (see page PF48)
PCB mounting minimizes space and provides
economical installation
Excellent filtering characteristics for high frequencies
Earth coil standard
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF21)
Applications
■
■
■
■
Circuit Diagram
1
CX
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
L1
CY
2
3
E
4
L2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BHS-010-3-11
60-BHS-010-3-4
60-BHS-010-5-11
250VAC
60-BHS-020-3-11
60-BHS-020-5-11
250VAC
60-BHS-030-3-11
60-BHS-030-5-11
250VAC
60-BHS-060-3-11
60-BHS-060-5-11
250VAC
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
3A
60-BHS-030-5-4
60-BHS-060-3-4
Capacitance
2A
60-BHS-020-5-4
60-BHS-030-3-4
CY
1A
60-BHS-010-5-4
60-BHS-020-3-4
Leakage Current
(Max.)
6A
60-BHS-060-5-4
CX
Inductance
(L1)
(L2)
Temperature
Rise (Max.)
0.1uF ± 20%
.047uF ± 20%
0.1uF ± 20%
6mH
18.3uH
30°C
2.4mH
18.3uH
30°C
1.2mH
18.3uH
30°C
.53mH
18.3uH
45°C
.047uF ± 20%
0.1uF ± 20%
.047uF ± 20%
0.1uF ± 20%
.047uF ± 20%
0.1uF ± 20%
.047uF ± 20%
0.1uF ± 20%
.047uF ± 20%
0.1uF ± 20%
.047uF ± 20%
0.1uF ± 20%
.047uF ± 20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF20
Power Entry Modules
High Frequency Attenuation
60-BHS Series
.098
(2.5)
1.967 (50)
1.573 (40)
Temperature Characteristics
120
.885
(22.5)
Current (%)
100
1.180 (30)
60
.031 (.8)
.5
R4
.865
(22)
40
2- .142
(3.6)
1.573 (40)
.779 1.180
(19.8) (30)
Panel cutout dimensions
mounts from backside
20
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
Dimensions in inches (mm)
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
60-BHS-XXX-X-11
80
90
60-BHS-020-X-11
60
50
40
60-BHS-030-X-11
30
60-BHS-060-X-11
20
50Ω
60-BHS-XXX-3-11
70
60-BHS-010-3-11
60
50
60-BHS-020-3-11
40
60-BHS-030-3-11
30
60-BHS-060-3-11
20
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
60-BHS-XXX-X-4
90
60-BHS-020-X-4
60
50
40
60-BHS-030-X-4
30
60-BHS-060-X-4
20
10
20
50
60-BHS-XXX-3-4
70
60-BHS-010-3-4
60
50
60-BHS-020-3-4
*
40
60-BHS-030-3-4
30
60-BHS-060-3-4
20
10
0
0.1
5
80
60-BHS-010-X-4
70
Insertion Loss (dB)
Insertion Loss (dB)
80
2
Frequency (MHz)
Frequency (MHz)
90
50Ω
Level
Meter
50Ω
80
60-BHS-010-X-11
70
Insertion Loss (dB)
Insertion Loss (dB)
1.180
(30)
2- .142
(3.6)
80
90
1.534 (39)
1.389
(35.3)
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF21
Power Entry Modules
Bolt-in
Rear Terminals
For General Purpose Applications
10-BPF Series
Features
■
■
■
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Operating temperature: -25°C to +70°C
Compact configuration
Circuit Diagram
CX
CY
Applications
■
■
■
■
CY
L1
1
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CX
CY
L1
CX
CY
2
CX
CX
L1
CY
CY
3
Specifications
Model
Rated
Rated
Voltage
Current
(@ 50/60Hz)
10-BPF-001-5-A
Leakage
Current
(Max.)
120/250VAC
1.5mH
0.50mA
6A
10-BPF-010-5-A
4700pF
Temperature
Rise
(Max.)
C
A
C
2
B
A
0.5mH
1
3300pF & 0.01uF
1.5mH
2
B
3300pF
0.01uF
0.5mH
1
A
3300pF & 0.01uF
3300pF & 0.01uF
1.5mH
3
B
3300pF
3300pF & 0.01uF
10A
0.01uF
Figure
A
3.0mH
1
3A
10-BPF-006-5-D
10-BPF-010-5-D
Inductance Circuit
(L1)
Diagram
3300pF
10-BPF-003-5-C
10-BPF-006-5-C
CX
2200pF
10-BPF-003-5-A
10-BPF-006-5-A
Capacitance
1A
10-BPF-001-5-C
10-BPF-003-5-D
CY
30°C
C
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF22
Power Entry Modules
Bolt-in
Rear Terminals
For General Purpose Applications
10-BPF Series
Figure B
M3 (2X)
1.6
(40)
M3 (2X)
2.0 (52)
2.0 (52)
1.1 (28.5)
+.01 -0.0
1.6 (40)
±.007
Figure A
1.4 (37)
2.8 (72)
1.25 (32)
Figure C
.80 (20.5)
+.01 -0.0
1.4 (3.5) (2X)
2.3 (62)
1.9 1.6 1.2
(50) (40) (30)
.13 (3.5 (2X)
1.1 (28)
.62 (16)
.82 (21)
.25
(6.5)
1.5 (37.5)
1.6 (40)
2.0 (51)
1.9 (50)
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
70
10-BPF-001-5-A
10-BPF-001-5-C
50
40
10-BPF-003-5-A
30
10-BPF-003-5-C
20
60
10-BPF-001-5-A
50
10-BPF-001-5-C
40
30
10-BPF-003-5-A
20
10-BPF-003-5-C
10
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
70
Insertion Loss (dB)
Insertion Loss (dB)
50
10-BPF-006-5-A
10-BPF-006-5-C
40
30
20
10-BPF-010-5-A
10
0
0.1
0.5
1
20
50
2
10-BPF-006-5-D
60
50
40
30
10-BPF-010-5-A
1
10-BPF-010-5-D
10-BPF-006-5-A
20
10-BPF-006-5-C
10
10-BPF-010-5-D
0.2
10
80
10-BPF-006-5-D
70
5
10-BPF-006;-010
10-BPF-006;-010
80
2
Frequency (MHz)
Frequency (MHz)
60
50Ω
Level
Meter
50Ω
80
Insertion Loss (dB)
Insertion Loss (dB)
50Ω
10-BPF-001;-003
10-BPF-001;-003
80
0
0.1
.07 (2)
Normal Mode
1
3
Filter
2
4
60
1.1 (27)
Dimensions in inches (mm)
Common Mode
70
1.8 (46)
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF23
Power Entry Modules
Bolt-in
Rear Terminals
For Medical Purpose Applications
10-BPF Series
Features
■
■
■
■
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Operating temperature: -25°C to +70°C
Compact configuration
Low leakage current
Circuit Diagram
1
Applications
■
■
■
■
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
E
3
L1
CX
E
2
4
Specifications
Model
Rated
Rated
Voltage
Current
(@ 50/60Hz)
10-BPF-001-2-A
1A
10-BPF-003-2-A 120/250VAC
3A
10-BPF-006-2-A
6A
Leakage
Current
(Max.)
Capacitance
CX
Inductance
(L1)
Circuit
Diagram
Figure
Temperature
Rise
(Max.)
1
A
30°C
3.0mH
5uA
0.01uF
1.5mH
0.5mH
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF24
Power Entry Modules
Bolt-in
Rear Terminals
For Medical Purpose Applications
10-BPF Series
M3 (2X)
1.1 (28.5)
+.01 -0.0
1.6 (40)
±.007
.80 (20.5)
+.01 -0.0
1.4 (3.5)
(2X)
0.837
(21.3)
1.9 1.6 1.2
(50) (40) (30)
Dimensions in inches (mm)
1.1 (28)
1.5 (37.5)
.63 (16)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
70
70
10-BPF-001-2-A
50
10-BPF-003-2-A
40
30
20
10-BPF-006-2-A
10
0
0.1
0.2
0.5
1
2
50Ω
50Ω
Level
Meter
50Ω
10-BPF-001;-003;-006
80
Insertion Loss (dB)
Insertion Loss (dB)
10-BPF-001;-003;-006
80
60
2.0 (51)
.25
(6.5)
.82 (21)
5
Frequency (MHz)
60
50
40
30
20
10-BPF-006-2-A
10-BPF-001-2-A
10
10
20
50
0
0.1
10-BPF-003-2-A
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF25
Power Entry Modules
Snap-in with Wire Leads
60-SPL Series
Features
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Snap-in style saves labor and hardware inventory
Wire output minimizes space and provides
economical installation
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF27)
Applications
■
■
■
■
Circuit Diagram
1
CX
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
3
CY
L1
CY
E
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-SPL-010-3-2
60-SPL-010-3-3
60-SPL-010-5-2
250VAC
60-SPL-020-3-2
60-SPL-020-5-2
250VAC
60-SPL-030-3-2
60-SPL-030-5-2
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.50mA
60-SPL-030-5-3
60-SPL-060-5-2
2200pF ± 20%
3A
60-SPL-060-3-2
60-SPL-060-3-3
0.35mA
0.35mA
250VAC
250VAC
Capacitance
2A
60-SPL-020-5-3
60-SPL-030-3-3
CY
1A
60-SPL-010-5-3
60-SPL-020-3-3
Leakage Current
(Max.)
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
6A
60-SPL-060-5-3
CX
Inductance
(L1)
Temperature
Rise (Max.)
6.0mH
30°C
2.4mH
30°C
1.2mH
30°C
0.53mH
45°C
22nF ± 20%
33nF ± 20%
22nF ± 20%
33nF ± 20%
22nF ± 20%
33nF ± 20%
22nF ± 20%
33nF ± 20%
.022uF ± 20%
.033uF ± 20%
22nF ± 20%
33nF ± 20%
22nF ± 20%
33nF ± 20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF26
Power Entry Modules
Snap-in with Wire Leads
60-SPL Series
Temperature Characteristics
120
80
W
T
W
.039 (1.0)
1.270 (32.3)
.047 (1.2)
1.274 (32.4)
.059 (1.5)
1.285 (32.5)
T :Panel Thickness
1.612 (41)
4.719 (120)*
.252 (6.4)
1.172 (29.8)
Blue
UL 1015 AWG #18
1.397
(35.5)
40
PVC Insulated wire
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
80
60-SPL-020-5-X
70
50Ω
50Ω
Level
Meter
50Ω
60-SPL-010;-020
60-SPL-010;-020
80
UL1617 AWG #22
Dimensions in inches (mm)
Common Mode
Insertion Loss (dB)
60-SPL-010-5-X
50
60-SPL-010-3-X
40
60-SPL-010-X-4
70
60-SPL-020-3-X
60
Green/Yellow
Brown
* Custom lengths available upon request.
0
Insertion Loss (dB)
.236 (6)
60
20
30
20
60-SPL-010-X-2
60
50
60-SPL-020-X-4
40
30
60-SPL-020-X-2
20
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
80
60-SPL-030-5-X
70
Insertion Loss (dB)
50
40
60-SPL-060-5-X
30
60-SPL-060-3-X
20
60
0.2
0.5
1
20
50
60-SPL-030-X-2
50
40
60-SPL-060-X-4
30
20
60-SPL-060-X-2
10
10
0
0.1
10
60-SPL-030-X-4
70
60-SPL-030-3-X
60
5
60-SPL-030;-060
60-SPL-030;-060
80
2
Frequency (MHz)
Frequency (MHz)
Insertion Loss (dB)
.853
(21.7)
.838 (21.3)
Panel cutout dimensions
100
Current (%)
.963
(24.5)
* General tolerance
± .012 (.3)
R2
* Metal case
Tin Plated
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF27
Power Entry Modules
Bolt-in with Wire Leads
60-BPL Series
Features
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Wire output for minimizing space use
and economical installation
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF28)
■
■
■
■
■
■
Circuit Diagram
1
Applications
■
■
■
■
CX
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
3
CY
L1
CY
E
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPL-010-3-2
60-BPL-010-3-3
60-BPL-010-5-2
250VAC
60-BPL-020-3-2
60-BPL-020-3-3
250VAC
60-BPL-030-3-2
60-BPL-030-5-2
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.50mA
60-BPL-060-3-2
60-BPL-060-3-3
2200pF ± 20%
3A
60-BPL-030-5-3
60-BPL-060-5-2
0.35mA
0.35mA
250VAC
250VAC
Capacitance
2A
60-BPL-020-5-3
60-BPL-030-3-3
CY
1A
60-BPL-010-5-3
60-BPL-020-5-2
Leakage Current
(Max.)
2200pF ± 20%
3300pF ± 20%
2200pF ± 20%
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
6A
60-BPL-060-5-3
CX
Inductance
(L1)
Temperature
Rise (Max.)
6.0mH
30°C
2.4mH
30°C
1.2mH
30°C
0.53mH
45°C
22nF ± 20%
33nF ± 20%
22nF ± 20%
33nF ± 20%
22nF ± 20%
33nF ± 20%
22nF ± 20%
33nF ± 20%
.022uF ± 20%
.033uF ± 20%
22nF ± 20%
33nF ± 20%
22nF ± 20%
33nF ± 20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF28
Power Entry Modules
Bolt-in with Wire Leads
60-BPL Series
Temperature Characteristics
.5
R4
.865
(22)
120
1.180 (30)
1.573 (40)
Current (%)
100
1.612 (41)
.830
(21.1)
4.719 (120)*
.252 (6.4)
1.967
(50)
1.172
(29.8)
20
30
40
50
60
70
Ambient Temperature (°C)
80
Oscillator
50Ω
90
1
3
Filter
2
4
Oscillator
50Ω
50Ω
80
60-BPL-020-5-X
60-BPL-010-3-X
30
20
Insertion Loss (dB)
60-BPL-010-5-X
40
60-BPL-010-X-4
70
60-BPL-020-3-X
50
60-BPL-010-X-2
60
50
60-BPL-020-X-4
40
30
60-BPL-020-X-2
20
10
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
80
60-BPL-030-5-X
70
Insertion Loss (dB)
50
40
60-BPL-060-5-X
30
60-BPL-060-3-X
20
60
0.5
1
20
50
60-BPL-030-X-2
50
40
60-BPL-060-X-2
30
20
60-BPL-060-X-4
10
10
0.2
10
60-BPL-030-X-4
70
60-BPL-030-3-X
60
5
60-BPL-030;-060
60-BPL-030;-060
80
2
Frequency (MHz)
Frequency (MHz)
0
0.1
50Ω
Level
Meter
50Ω
60-BPL-010;-020
60-BPL-010;-020
0
0.1
* General tolerance
±.012 (0.3)
Dimensions in inches (mm)
50Ω
Level
Meter
50Ω
60
BROWN
Normal Mode
1
3
Filter
2
4
70
GREEN/YELLOW
PVC Insulated wire
UL1617 AWG #22
* Custom lengths available upon request.
Common Mode
80
.236 (6)
UL1015 AWG # 18
BLUE
1.160
(29.5)
1.573
(40)
0
Insertion Loss (dB)
1.573 (40)
60
40
1.239 (31.5)
Panel cutout dimensions
mounts from front side
.944 (24)
2- .142
(3.6)
20
Insertion Loss (dB)
2- .118 (M3)
2- .130 (3.3)
Panel cutout dimensions
mounts from back side
80
.5
R3
.885
(22.5)
.837
(21.3)
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF29
Power Entry Modules
Bolt-in with Wire Leads
10-BPL Series
Features
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Wire output for minimizing space use
and economical installation
Operating temperature: -25°C to +70°C
Compact configuration
■
■
■
■
■
■
■
Circuit Diagram
Applications
■
■
■
■
1
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
3
CY
L1
CX
E
CY
2
4
Specifications
Model
Rated
Rated Leakage
Voltage
Current Current
(@ 50/60Hz)
(Max.)
10-BPL-006-5-B
Capacitance
CX
250VAC
3A
Inductance Circuit
Diagram
(L1)
Figure
Temperature
Rise
(Max.)
A
30°C
3.0mH
1A
10-BPL-001-5-B
10-BPL-003-5-B
CY
0.50mA
6A
3300pF
0.01uF
1.5mH
1
0.5mH
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF30
Power Entry Modules
Bolt-in with Wire Leads
10-BPL Series
M3 (2X)
Figure A
1.1 (28.5)
+.01 -0.0
1.6 (40)
.007
.80 (20.5)
+.01 -0.0
1.4 (3.5)
(2X)
1.9 1.6 1.2
(50) (40) (30)
1.1 (28)
1.5 (37.5)
.63 (16)
4.72 (120±2)
.25
(6.5)
.82 (21)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
1
10-BPL-001;-003;-006
10-BPL-001-5-B
50
40
30
10-BPL-006-5-B
20
60
50
40
10-BPL-003-5-B
30
20
10-BPL-006-5-B
10
10
0
0.1
10-BPL-001-5-B
70
10-BPL-003-5-B
Insertion Loss (dB)
Insertion Loss (dB)
60
0.2
0.5
1
2
50Ω
Level
Meter
50Ω
10-BPL-001;-003;-006
80
80
70
50Ω
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF31
Power Entry Modules
Snap-in Mount
60-SPR & SPS Series
Features
■
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased miniature filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Snap-in style saves labor and hardware inventory
Solder lug and fast-on tab terminations available
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF33)
UL approved low leakage version also available
Applications
■
■
■
■
Circuit Diagram
1
CX
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
3
CY
L1
CY
E
2
4
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-XXX-010-3-2
60-XXX-010-3-4
60-XXX-010-5-2
250VAC
60-XXX-020-3-2
60-XXX-020-5-2
250VAC
60-XXX-030-3-2
60-XXX-030-5-2
250VAC
60-XXX-060-3-2
60-XXX-060-5-2
250VAC
60-XXX-100-5-2
60-SPR-150-3-11
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
0.50mA
3300pF ± 20%
0.35mA
2200pF ± 20%
6A
60-XXX-060-5-4
60-XXX-100-3-2
0.35mA
Inductance
(L1)
Temperature
Rise (Max.)
6.0mH
30°C
2.4mH
30°C
1.2mH
30°C
0.53mH
45°C
250VAC
10A
.022uF ± 20%
0.26mH
45°C
250VAC
15A
.1uF ± 20%
0.15mH
45°C
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 45g
Input: Compatible with IEC-320
CX
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
3A
60-XXX-030-5-4
60-XXX-060-3-4
Capacitance
2A
60-XXX-020-5-4
60-XXX-030-3-4
CY
1A
60-XXX-010-5-4
60-XXX-020-3-4
Leakage Current
(Max.)
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
.022uF ± 20%
.047uF ± 20%
* Substitute SPR or SPS for XXX
60-SPR - Fast-on terminals
60-SPS - Solder lug terminals
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF32
Power Entry Modules
Snap-in Mount
60-SPR & SPS Series
R2
Temperature Characteristics
Current (%)
80
T: Panel Thickness
T
W
.039 (1.0)
1.270 (32.3)
.047 (1.2)
1.274 (32.4)
.059 (1.5)
1.285 (32.5)
60
W
Panel cutout dimensions
for 1.0t chassis
2.033 (51.7)
1.805 (45.9)
1.418 (35.9)
.252 (6.4)
.157
(4)
Solder Lug
2 X 3 hole
* Standard terminal
Fast-on tab #250
available as
SPR series
2.096 (53.3)
40
1.395
(35.5)
20
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Oscillator
50Ω
50Ω
Oscillator
50Ω
60-SPX-010;-020;-030
Insertion Loss (dB)
50
60-SPX-020-5-X
60-SPX-030-5-X
20
10
0
0.1
60
50
40
60-SPX-010-X-4
60-SPX-020-X-4
60-SPX-030-X-4
30
20
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
60-SPX-060;-100
70
70
Insertion Loss (dB)
80
60-SPX-60-5-X
50
2
5
10
20
50
60-SPX-060;-100
80
60
1
Frequency (MHz)
Frequency (MHz)
40
30
60-SPX-100-5-X
20
10
0
0.1
50Ω
Level
Meter
50Ω
60-SPX-010;-020;-030
70
30
50Ω
80
60-SPX-010-5-X
40
Dimensions in inches (mm)
1
3
Filter
2
4
50Ω
Level
Meter
80
60
* General tolerance
± .012 (0.3)
Normal Mode
1
3
Filter
2
4
70
1.172
(29.8)
Solder lugs shown. Also available in fast-ons.
Common Mode
Insertion Loss (dB)
.853
(21.7)
Panel cutout dimensions
100
Insertion Loss (dB)
.837
(21.3)
.963
(24.5)
120
60-SPX-060-X-4
60
50
60-SPX-060-X-2
40
60-SPX-100-X-2
30
20
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF33
Fused Filtered
Power
Entry Modules
For General Purpose Applications
64-65-BFF/64-65-BFS Series
Features
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
North American and Metric fuse
holders available
Fuse holder provides effective EMI suppression
of common and differential mode
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Fast-on terminals or solder lug terminals
Metal case provides effective EMI shielding
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF35)
Applications
■
■
■
■
■
Circuit Diagram
L
L
L1
E
R
CY
E
CX
CY
N
N
Computers and peripheral equipment
Electronic equipment
Digital equipment
Measuring and testing instruments
Telecommunications equipment
Specifications
Model*
64-XXX-020-3-11
64-XXX-020-5-11
64-XXX-020-3-12
64-XXX-020-5-12
64-XXX-040-3-11
64-XXX-040-5-11
64-XXX-040-3-12
64-XXX-040-5-12
64-XXX-060-3-11
64-XXX-060-5-11
64-XXX-060-3-12
64-XXX-060-5-12
65-XXX-020-3-11
65-XXX-020-5-11
65-XXX-020-3-12
65-XXX-020-5-12
65-XXX-040-3-11
65-XXX-040-5-11
65-XXX-040-3-12
65-XXX-040-5-12
65-XXX-060-3-11
65-XXX-060-5-11
65-XXX-060-3-12
65-XXX-060-5-12
Rated Voltage
(@ 50/60Hz)
250VAC
250VAC
250VAC
125VAC
125VAC
125VAC
Rated
Current
2A
4A
6A
2A
4A
6A
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
F(S) = Fast-on or (Solder lug terminals)
Leakage Current
(Max.)
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.35mA
0.50mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
0.20mA
0.25mA
Capacitance
CY
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
2200pF
3300pF
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
±
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
20%
Voltage Drop: 1V max. at rated current
Weight: 78g
Inlet: Compatible with IEC-320
CX
Inductance
(L1)
Temperature
Rise (Max.)
6.5mH
40°C
4.2mH
45°C
1.6mH
45°C
6.5mH
40°C
4.2mH
45°C
1.6mH
45°C
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
* Substitute BFF or BFS for XXX
BFF - Fast-on terminals
BFS - Solder lug terminals
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF34
Fused Filtered
Power
Entry Modules
For General Purpose Applications
64-65-BFF/64-65-BFS Series
Dimensions
Temperature Characteristics
64/65-BFF Series
120
1.738 (44.2)
100
Current (%)
2.32 (59)
.098 (2.5)
1.101 (28)
Fuse cover
1.376
(35)
80
1.298
(33)
60
1.416±.008
(36±0.2)
40
1.29
(32.8)
2 - .13 +.008
-.004
(2 - 3.3+0.2
-0.1)
Hole
0.252 (6.4)
1.14
(29)
1.616 (41.1)
* Alternate Terminal for 64/65-BFS-Solder Lug Terminal
Fast-on tab#250
t= .031 (0.8)
20
0.158
(4.0)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
2.249 (L:57.2)
Common Mode
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
0.50 mA Leakage Versions
90
80
Insertion Loss (dB)
Insertion Loss (dB)
60
50
40
6 Amp
30
0
0.1
0.2
0.5
60
50
6 Amp
40
4 Amp
30
10
1
2
5
Frequency (MHz)
10
20
0
0.1
50
0.35 mA Leakage Versions
90
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
10
20
50
0.35 mA Leakage Versions
80
80
70
70
Insertion Loss (dB)
2 Amp
60
50
40
6 Amp
30
2 Amp
60
50
40
30
6 Amp
4 Amp
20
20
4 Amp
10
0
0.1
2 Amp
20
4 Amp
10
50Ω
Level
Meter
50Ω
0.50 mA Leakage Versions
70
2 Amp
20
Insertion Loss (dB)
50Ω
80
70
90
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
90
* General Tolerance:
±.020 (0.5)
* Metal Case
0.2
0.5
10
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF35
Fused Filtered
Power
Entry Modules
For Medical or General Purpose Applications
■
■
■
■
■
■
■
■
■
■
Medical equipment
Electronic equipment
Digital equipment
Industrial equipment
■
■
■
Telecommunications equipment
Measuring and testing instruments
Personal computers
and peripherals
Circuit Diagrams
66/67-BFF(S)-XXX-0-X and
66/67-BFF(S)-XXX-4-X Filters
66/67-BFF(S)-XXX-1-X Filter
L
L
L
L
L1
R
E
L1
CX
E
E
R
CX
CY
E
LOAD
■
Applications
LINE
■
Tested and found to be
IAW VDE 0565 Part 3.
Metric and North American fuse
holders available
Fuse holder provides effective EMI suppression
of common and differential mode
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Fast-on terminations or solder lug terminations
Metal case provides effective EMI shielding
Provides susceptibility protection without the leakage
current associated with line-to-ground capacitance
Reduces the line to ground capacitance in order
to meet patient care requirements
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF37)
LOAD
■
LINE
66-67-BFF/66-67-BFS Series
Features
CY
N
N
N
N
Specifications
Model*
66-XXX-020-1-11
66-XXX-020-1-12
66-XXX-020-0-11
66-XXX-020-4-11
66-XXX-020-0-12
66-XXX-020-4-12
66-XXX-040-1-11
66-XXX-040-1-12
66-XXX-040-0-11
66-XXX-040-4-11
66-XXX-040-0-12
66-XXX-040-4-12
66-XXX-060-1-11
66-XXX-060-1-12
66-XXX-060-0-11
66-XXX-060-4-11
66-XXX-060-0-12
66-XXX-060-4-12
67-XXX-020-1-11
67-XXX-020-1-12
67-XXX-020-0-11
67-XXX-020-4-11
67-XXX-020-0-12
67-XXX-020-4-12
67-XXX-040-1-11
67-XXX-040-1-12
67-XXX-040-0-11
67-XXX-040-4-11
67-XXX-040-0-12
67-XXX-040-4-12
67-XXX-060-1-11
67-XXX-060-1-12
67-XXX-060-0-11
67-XXX-060-4-11
67-XXX-060-0-12
67-XXX-060-4-12
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
0.01mA
250VAC
2A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
4A
0.075mA
0.1mA
0.075mA
0.1mA
0.01mA
250VAC
6A
0.075mA
0.1mA
0.075mA
0.1mA
0.005mA
125VAC
2A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
4A
0.035mA
0.05mA
0.035mA
0.05mA
0.005mA
125VAC
6A
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
F(S) = Fast-on or (Solder lug terminals)
0.035mA
0.05mA
0.035mA
0.05mA
Capacitance
CY
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
none
330pF
470pF
330pF
470pF
±
±
±
±
20%
20%
20%
20%
Voltage Drop: 1V max. at rated current
Weight: 78g
Inlet: Compatible with IEC-320
CX
0.1uF
0.22uF
0.1uF
Inductance
(L1)
Temperature
Rise (Max.)
6.5mH
40°C
2.4mH
45°C
1.6mH
45°C
6.5mH
40°C
2.4mH
45°C
1.6mH
45°C
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
0.1uF
0.22uF
* Substitute BFF or BFS for XXX
BFF - Fast-on terminals
BFS - Solder lug terminals
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF36
Fused Filtered
Power
Entry Modules
For Medical or General Purpose Applications
66-67-BFF/66-67-BFS Series
Dimensions
Temperature Characteristics
66-67-BFF/66-67-BFS Series
120
1.738 (44.2)
Current (%)
2.32 (59)
.098 (2.5)
1.101 (28)
100
Fuse cover
1.376
(35)
80
1.298
(33)
60
1.416±.008
(36±0.2)
40
1.29
(32.8)
2 - .13 +.008
-.004
(2 - 3.3+0.2
-0.1)
Hole
0.252 (6.4)
1.14
(29)
1.616 (41.1)
* Alternate Terminal for 66/67-BFS-Solder Lug Terminal
Fast-on tab#250
t= .031 (0.8)
20
0
0.158
(4.0)
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
2.249 (L:57.2)
Common Mode
Oscillator
50Ω
90
80
70
70
Insertion Loss (dB)
80
60
2 Amp
40
30
0
0.1
90
0.2
0.5
1
2
5
Frequency (MHz)
10
20
60
30
90
80
70
70
60
2 Amp
40
30
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
6 Amp
0.2
20
50
1
2
5
Frequency (MHz)
10
20
50
60
2 Amp
50
40
30
0
0.1
6 Amp
4 Amp
10
10
0.5
0.075 and 0.1 mA Leakage Current
20
6 Amp
4 Amp
10
4 Amp
40
80
20
2 Amp
50
0
0.1
50
50Ω
Level
Meter
50Ω
0.01 mA Leakage Current
10
0.075 and 0.1 mA Leakage Current
50
50Ω
20
6 Amp
4 Amp
10
Insertion Loss (dB)
Insertion Loss (dB)
Oscillator
50Ω
0.01 mA Leakage Current
20
Insertion Loss (dB)
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
50
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
90
* General Tolerance:
±.020 (0.5)
* Metal Case
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF37
Switched and Fused Filtered
Power
Entry Modules
For General Purpose Applications
64-65-BSF/64-65-SSF Series
Features
■
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3.
North American and Metric fuse
holders available
Fuse holder and double pole power ON/OFF switch
provided in a convenient/compact package
Suitable for products that must conform
to FCC and FTZ requirements
Meets over voltage category II of IEC 664
and complies with IEC 950
Metal case provides effective EMI shielding
Easy access fuse drawer with space for spare fuse
Flange-mounted or snap-in styles available
for quick mounting
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF39)
Applications
■
■
Computers and
peripheral equipment
Electronic equipment
■
■
■
Digital equipment
Measuring and testing instruments
Telecommunications equipment
Circuit Diagram
L
CY
E
R
CX
CX
L
E
CY
N
N
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
Rated
Current
64-XXX-020-3-12
64-XXX-020-3-04
64-XXX-020-3-14
64-XXX-020-3-06
250VAC
2A
64-XXX-020-5-12
64-XXX-020-5-04
64-XXX-020-5-14
64-XXX-020-5-06
64-XXX-040-3-12
64-XXX-040-3-04
64-XXX-040-3-14
64-XXX-040-3-06
250VAC
4A
64-XXX-040-5-12
64-XXX-040-5-04
64-XXX-040-5-14
64-XXX-040-5-06
64-XXX-060-3-12
64-XXX-060-3-04
64-XXX-060-3-14
64-XXX-060-3-06
250VAC
6A
64-XXX-060-5-12
64-XXX-060-5-04
64-XXX-060-5-14
64-XXX-060-5-06
65-XXX-020-3-12
65-XXX-020-3-04
65-XXX-020-3-14
65-XXX-020-3-06
125VAC
2A
65-XXX-020-5-12
65-XXX-020-5-04
65-XXX-020-5-14
65-XXX-020-5-06
65-XXX-040-3-12
65-XXX-040-3-04
65-XXX-040-3-14
65-XXX-040-3-06
125VAC
4A
65-XXX-040-5-12
65-XXX-040-5-04
65-XXX-040-5-14
65-XXX-040-5-06
65-XXX-060-3-12
65-XXX-060-3-04
65-XXX-060-3-14
65-XXX-060-3-06
125VAC
6A
65-XXX-060-5-12
65-XXX-060-5-04
65-XXX-060-5-14
65-XXX-060-5-06
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
B(S) = Bolt-in terminals or (Snap-in terminals)
Leakage Current
(Max.)
CY
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.20mA
2200pF
0.25mA
3300pF
0.20mA
2200pF
0.25mA
3300pF
0.20mA
2200pF
0.25mA
3300pF
Capacitance
CX1
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
CX2
Inductance
(L1)
NONE
0.22uF
NONE
10.5mH
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
4.2mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
1.6mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
10.5mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
4.2mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
1.6mH
NONE
0.22uF
NONE
0.22uF
* Substitute BSF or SSF for XXX
BSF - Bolt-in switched and fused
SSF - Snap-in switched and fused
Temperature
Rise (Max.)
45°C
45°C
45°C
45°C
45°C
45°C
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF38
Temperature
Temperature Characteristics
Characteristics
120
Current (%)
100
Switched and Fused Filtered
Power
Entry Modules
For General Purpose Applications
80
60
40
20
0
30
40
50
60
70
Ambient Temperature (°C)
80
90
64/65-SSF Series
Dimensions
64/65-BSF Series
1.947 (49.5)
1.101 (28)
20
1.313 (33.4)
1.101 (28)
.248
(6.3)
.248
(6.3)
1.133
(28.8)
1.514 (38.8)
1.526 (38.8)
Fast-on tab #250
t= .031 (0.8)
2.556
(65)
2.556
(65)
2.340
(59.5)
2.348
(59.7)
2.348
(59.7)
2.340
(59.5)
Ø.142
(3.6)
1.573 (40±0.2)
R .079
(2.0)
1.133
(28.8)
Fast-on Tab #250
2.273 (57.8)
2 - .142
(3.6) Hole
R .059
(1.5)
Thickness of Panel
.031 (0.8t)
.039 (1.0t)
.047 (1.2t)
.059 (1.5t)
.071 (1.8t)
.079 (2.0t)
A
t= .031 (0.8)
Panel cutout
dimension
mount from
back side
1.573 1.16±.334
0
(40.±0.2) (29.5± 0.5)
0
2.273 (57.8)
Dimensions in inches (mm)
Panel cutout dimension
mount from back side
1.16 +.02
-0
(29.5 +0.5
-0 )
A
2.430 (61.8±0.1)
2.446 (62.2±0.1)
2.462 (62.6±0.1)
2.470 (62.8±0.1)
2.473 (62.9±0.1)
2.477 (63.0±0.1)
* General Tolerance
± .039 (1.0)
* Metal Case
2.399 (61)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
Oscillator
50Ω
0.35 mA Leakage Versions
100
80
90
70
80
2 Amp
60
Insertion Loss (dB)
Insertion Loss (dB)
90
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50
40
4 Amp
30
6 Amp
20
90
0.2
1
0.5
2
5
Frequency (MHz)
10
20
60
50
2 Amp
40
4 Amp
6 Amp
0
0.1
50
0.50 mA Leakage Versions
100
80
0.5
1
2
5
Frequency (MHz)
10
20
50
20
50
64/65-B(S)SF-*-*-11(12,14)
80
Insertion Loss (dB)
2 Amp
60
50
40
4 Amp
30
6 Amp
20
70
60
4 Amp
6 Amp
50
2 Amp
40
30
10
0
0.1
0.2
90
70
Insertion Loss (dB)
70
20
0
0.1
50Ω
Level
Meter
50Ω
64/65-B(S)SF-*-*-02(04,06)
30
10
50Ω
20
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF39
Switched and Fused Filtered
Power
Entry Modules
For Medical or General Purpose Applications
66-67-BSF/66-67-SSF Series
Features
Tested and found to be
IAW VDE 0565 Part 3
Metric and North American fuse holders available
Fuse holder and a double pole power ON/OFF switch
provides a convenient/compact package
■ Suitable for products that must conform
to FCC and FTZ requirements
■ Meets over voltage category II of IEC 664
and complies with IEC 950
■ Provides susceptibility protection without the leakage
current associated with line-to-ground capacitors
■ Designed to meet requirements for non-patient
and patient care equipment
■ Metal case provides effective EMI shielding
■ Easy access fuse drawer - space for spare fuse
■ Flange-mounted or snap-in styles available
for quick mounting
■ Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF41)
■
■
Applications
■
■
■
■
Medical equipment
Industrial equipment
Telecommunications equipment
Measuring and testing instruments
■
■
Digital equipment (including
switching power supplies)
General purpose filter for
susceptibility or high frequency
“clean up” applications
Circuit Diagram
L
L
E
L1
CX1
CX2
CY1
E
LOAD
R
LINE
Note: CY1 and CY2 capacitors
omitted on 66/67
B(S)F-XXX-1-X Filters
CY2
N
N
Specifications
Model*
66-XXX-020-0-12
66-XXX-020-0-04
66-XXX-020-0-14
66-XXX-020-0-06
66-XXX-020-1-12
66-XXX-020-1-04
66-XXX-020-1-14
66-XXX-020-1-06
66-XXX-020-4-12
66-XXX-020-4-04
66-XXX-020-4-14
66-XXX-020-4-06
66-XXX-040-0-12
66-XXX-040-0-04
66-XXX-040-0-14
66-XXX-040-0-06
66-XXX-040-1-12
66-XXX-040-1-04
66-XXX-040-1-14
66-XXX-040-1-06
66-XXX-040-4-12
66-XXX-040-4-04
66-XXX-040-4-14
66-XXX-040-4-06
66-XXX-060-0-12
66-XXX-060-0-04
66-XXX-060-0-14
66-XXX-060-0-06
66-XXX-060-1-12
66-XXX-060-1-04
66-XXX-060-1-14
66-XXX-060-1-06
66-XXX-060-4-12
66-XXX-060-4-04
66-XXX-060-4-14
66-XXX-060-4-06
Rated Rated Leakage
Voltage Current Current
Capacitance
50/60Hz
(Max.) CY
CX1
CX2
.075mA 330pF
2A
.01mA NONE
0.1mA 470pF
.075mA 330pF
250
VAC
4A
.01mA NONE
.01mA 470pF
.075mA 330pF
6A
.01mA NONE
0.1mA 470pF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
Temp.
Induct.
(L1)
Rise
(Max.)
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF 10.5mH 40°C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
4.2mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
45°C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
1.6mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
Note: Test Voltage: 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
Voltage Drop: 1V max. at rated current
Model*
67-XXX-020-0-12
67-XXX-020-0-04
67-XXX-020-0-14
67-XXX-020-0-06
67-XXX-020-1-12
67-XXX-020-1-04
67-XXX-020-1-14
67-XXX-020-1-06
67-XXX-020-4-12
67-XXX-020-4-04
67-XXX-020-4-14
67-XXX-020-4-06
67-XXX-040-0-12
67-XXX-040-0-04
67-XXX-040-0-14
67-XXX-040-0-06
67-XXX-040-1-12
67-XXX-040-1-04
67-XXX-040-1-14
67-XXX-040-1-06
67-XXX-040-4-12
67-XXX-040-4-04
67-XXX-040-4-14
67-XXX-040-4-06
67-XXX-060-0-12
67-XXX-060-0-04
67-XXX-060-0-14
67-XXX-060-0-06
67-XXX-060-1-12
67-XXX-060-1-04
67-XXX-060-1-14
67-XXX-060-1-06
67-XXX-060-4-12
67-XXX-060-4-04
67-XXX-060-4-14
67-XXX-060-4-06
Rated Rated Leakage
Voltage Current Current
Capacitance
50/60Hz
(Max.) CY
CX1
CX2
0.04mA 330pF
2A
.005mA NONE
0.05mA 470pF
0.04mA 330pF
125
VAC
4A
.005mA NONE
0.05mA 470pF
0.04mA 330pF
6A
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals or (Snap-in terminals)
.005mA NONE
0.05mA 470pF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
0.22uF
0.47uF
Temp.
Induct.
(L1)
Rise
(Max.)
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF 10.5mH 40°C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
4.2mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
45°C
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
1.6mH
NONE
0.22uF
NONE
0.22uF
NONE
0.22uF
* Substitute BSF or SSF for XXX
BSF - Bolt-In Switched and Fused
SSF - Snap-In Switched and Fused
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF40
Temperature Characteristics
120
Current (%)
100
Switched and Fused Filtered
Power
Entry Modules
For Medical or General Purpose Applications
80
60
40
20
0
Dimensions
66/67-BSF Series
1.947 (49.5)
1.101 (28)
20
1.313 (33.4)
1.101 (28)
1.526 (38.8)
2.556
(65)
.248
(6.3)
2.340
(59.5)
Ø.142
(3.6)
Fast-on tab #250
t= .031 (0.8)
R .059
(1.5)
Panel cutout
dimension
mount from
back side
Dimensions in inches (mm)
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
90
80
70
70
Insertion Loss (dB)
80
2 Amp
50
40
30
20
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
0.01 mA Leakage Current
60
2 Amp
50
40
30
4 Amp
6 Amp
0
0.1
50
0.075 and 0.1 mA Leakage Current
90
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
50Ω
Level
Meter
50Ω
10
10
90
50Ω
20
6 Amp
4 Amp
A
2.430 (61.8±0.1)
2.446 (62.2±0.1)
2.462 (62.6±0.1)
2.470 (62.8±0.1)
2.473 (62.9±0.1)
2.477 (63.0±0.1)
* General Tolerance
± .039 (1.0)
* Metal Case
Panel cutout dimension
mount from back side
1.16 +.02
-0
(29.5 +0.5
-0 )
0.01 mA Leakage Current
60
Thickness of Panel
.031 (0.8t)
.039 (1.0t)
.047 (1.2t)
.059 (1.5t)
.071 (1.8t)
.079 (2.0t)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
2.273 (57.8)
A
Common Mode
Insertion Loss (dB)
R .079
(2.0)
t= .031 (0.8)
2.399 (61)
90
2.340
(59.5)
2.348
(59.7)
1.133
(28.8)
Fast-on Tab #250
2.273 (57.8)
2 - .142
(3.6) Hole
1.573
1.16 +.02
-0
(40.±0.2) (29.5 +0.5)
-0
90
1.133
(28.8)
1.514 (38.8)
2.556
(65)
1.573 (40±0.2)
80
66/67-SSF Series
.248
(6.3)
2.348
(59.7)
30
40
50
60
70
Ambient Temperature (°C)
2 Amp
50
40
30
20
0
0.1
0.2
0.5
0.5
1
2
5
Frequency (MHz)
10
20
50
0.075 and 0.1 mA Leakage Current
2 Amp
60
50
40
4 Amp
30
6 Amp
20
6 Amp
4 Amp
10
0.2
10
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF41
Switched and Fused Filtered
Power
Entry Modules
Dual Fuse for European Applications
68-BSF Series
Features
Dual fuse for European applications
Fuse holder and double pole power ON/OFF switch
provides a convenient/compact package
■ Suitable for products that must conform
to FCC and FTZ requirements
■ Meets over voltage category II of IEC 664
and complies with IEC 950
■ Metal case provides effective EMI shielding
■ IEC connector meets the safety standards of most
certifying agencies
■ Easy access fuse drawer
■ Flange-mounted
■ UL, CSA, and SEMKO approved
■ Designed to be in accordance with VDE 0565, part 3
■ Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF43)
■
■
Circuit Diagram
FUSE
L
L
L1
E
R1
CX2
CX1
L2
N
CY1
E
CY2
N
SW
Applications
Computers and peripheral equipment
Electronic equipment
■ Digital equipment
■ Measuring and testing instruments
■ Telecommunications equipment
■
■
Specifications
Model
Rated Voltage
(@ 50/60Hz)
68-BSF-020-3-01
68-BSF-040-3-04
68-BSF-060-3-01
68-BSF-060-3-04
Leakage Current
(Max.)
CY1
Capacitance
CY2
CX1
2A
68-BSF-020-3-04
68-BSF-040-3-01
Rated
Current
250VAC
4A
6A
0.35mA
2200pF
2200pF
CX2
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
0.1uF
0.1uF
0.22uF
0.22uF
Inductance
(L1)
Temperature
Rise (Max.)
10.5mH
4.2mH
45°C
1.6mH
Note: Test Voltage 1500VAC one minute, line to ground
Insulation Resistance: 300 MΩ min. at 500VDC
Voltage Drop: 1V max. at rated current
Weight: 130g
Inlet: Compatible with IEC-320
B(S) = Bolt-in terminals
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF42
Switched and Fused Filtered
Power
Entry Modules
Dual Fuse for European Applications
68-BSF Series
Temperature Characteristics
1.947 (49.5)
1.101 (28)
.248
(6.3)
1.526 (38.8)
120
Current (%)
100
2.556
(65)
80
2.348
(59.7)
60
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
t= .031 (0.8)
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
R .059
(1.5)
Panel cutout
dimension
mount from
back side
2.399 (61)
Common Mode
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
90
50Ω
50Ω
Level
Meter
50Ω
100
90
70
80
Insertion Loss (dB)
80
60
50
40
4 Amp
30
2 Amp
6 Amp
20
70
4 Amp
60
50
2 Amp
40
30
10
0
0.1
2 - .142
(3.6) Hole
1.573
1.16 +.02
-0
(40.±0.2) (29.5 +0.5)
-0
0
1.133
(28.8)
Fast-on Tab #250
2.273 (57.8)
1.573 (40±0.2)
40
20
Insertion Loss (dB)
2.340
(59.5)
Ø.142
(3.6)
6 Amp
20
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF43
PCB Power Filters
Miniature Printed Circuit Board
61-MPC Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
Miniature general purpose PCB mounted filter
Requires minimal PCB real estate space
Low cost
Designed for two wire cord systems
For three wire cord systems, Y capacitors
can be attached externally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF45)
Applications
■
■
■
■
■
Circuit Diagram
3
1
Personal computers and peripherals
Digital equipment
Measuring instruments and medical equipment
TV & VCR monitors and display units
Home appliances
L1
CX1
CX1
2
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
61-MPC-010-1-11
61-MPC-016-1-11
61-MPC-025-1-11
61-MPC-036-1-11
Rated
Current
Leakage Current
(Max.)
CX1
Capacitance
CX2
1A
250VAC
1.6A
2.5A
3.6A
Inductance
(L1)
Temperature
Rise (Max.)
11mH
0.1mA
0.1uF
0.1uF
6.0mH
2.4mH
40°C
1.2mH
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 17.5g
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF44
PCB Power Filters
Miniature Printed Circuit Board
61-MPC Series
4
3
4 — .031 (.8)
.551 (14)
2
1
.767 (19.5)
.059 (1.5)
1.239 (31.5)
.767 (19.5)
.590 (15)
.354 (9)
Dimensions in inches (mm)
Temperature Characteristics
Common Mode
1
3
Filter
2
4
Oscillator
50Ω
100
50Ω
Level
Meter
50Ω
1
3
Filter
2
4
(Test circuit 2)
Oscillator
50Ω
Current (%)
Common
mode with
Y cap.
(Test circuit 1)
120
50Ω
Level
Meter
50Ω
80
60
40
20
0
0
30
40
50
60
70
80
Ambient Temperature (°C)
90
100
61-MPC
80
Insertion Loss (dB)
70
Y Cap
2 X 3300pF
61-MPC-010-1-11
60
Normal Mode
50
40
30
61-MPC-025-1-11
20
0
0.1
Oscillator
50Ω
61-MPC-036-1-11
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50Ω
Level
Meter
50Ω
61-MPC
61-MPC
80
70
70
61-MPC-010-1-11
60
Insertion Loss (dB)
Insertion Loss (dB)
50Ω
50
80
50
40
30
61-MPC-016-1-11
20
61-MPC-025-1-11
10
0
0.1
1
3
Filter
2
4
(Test circuit 3)
61-MPC-016-1-11
0.5
1
50
61-MPC-010-1-11
40
61-MPC-016-1-11
30
61-MPC-025-1-11
20
61-MPC-036-1-11
10
61-MPC-036-1-11
0.2
60
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF45
Power Entry Modules
Bolt-in Right Angle Terminals
for PCB Applications
60-BPP Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal case offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Uses IEC connector that meets most safety standards
Solder lug, Fast-on tab styles available (see page PF18)
PCB mounting style minimizes space and provides
economical installation
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF47)
UL approved low leakage version also available
■
■
■
1
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
L1
CX
E
Applications
■
Circuit Diagram
CY
2
3
E
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BPP-010-3-2
60-BPP-010-3-4
60-BPP-010-5-4
60-BPP-020-3-2
60-BPP-020-3-4
60-BPP-030-3-4
60-BPP-030-5-2
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
3A
0.50mA
60-BPP-060-3-2
60-BPP-060-5-2
0.35mA
250VAC
60-BPP-030-5-4
60-BPP-060-3-4
Capacitance
2A
60-BPP-020-5-2
60-BPP-030-3-2
CY
1A
60-BPP-010-5-2
60-BPP-020-5-4
Leakage Current
(Max.)
0.35mA
3300pF
2200pF
6A
60-BPP-060-5-4
0.50mA
3300pF
CX
Inductance
(L1)
Temperature
Rise (Max.)
0.022uF
0.047uF
0.022uF
6.0mH
0.047uF
0.022uF
0.047uF
0.022uF
2.4mH
30°C
0.047uF
0.022uF
0.047uF
0.022uF
1.2mH
0.047uF
0.022uF
0.047uF
0.022uF
0.53mH
45°C
0.047uF
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF46
Power Entry Modules
Bolt-in Right Angle Terminals
for PCB Applications
60-BPP Series
Temperature Characteristics
120
100
Current (%)
.098 (2.5)
60-BPP
PCB
Mounting
Type
1.463 (37.2)
1.967 (50)
1.317
(33.5)
1.573 (40)
.885
(22.5)
2- .142
(3.6)
80
.024
(.6)
.5
R4
.865
(22)
40
2- .142
(3.6)
1.573 (40)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
.142
.059 (3.6)
(1.5)
.031 (.8)
1.070
(27.2)
.779 1.180
(19.8) (30)
.708
(18)
Dimensions in inches (mm)
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
70
50Ω
Level
Meter
50Ω
80
70
Insertion Loss (dB)
60-BPP-010-3-X
60
50Ω
60-BPP-010;-020
60-BPP-010;-020
80
Insertion Loss (dB)
* General
tolerance
± .012 (.3)
Panel cutout dimensions
mounts from backside
20
50
60-BPP-020-3-X
40
30
20
60
60-BPP-010-X-4
50
40
30
60-BPP-020-X-4
20
10
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
60-BPP-030;-060
70
70
Insertion Loss (dB)
80
60-BPP-030-3-X
50
40
60-BPP-060-3-X
30
20
10
0
0.1
5
10
20
50
20
50
60-BPP-030;-060
80
60
2
Frequency (MHz)
Frequency (MHz)
Insertion Loss (dB)
.047 (1.2)
.232 (5.9)
1.180 (30)
60
.991
(25.2)
.590 (15)
60
50
40
30
60-BPP-030-X-4
60-BPP-060-X-4
20
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF47
Power Entry Modules
High Frequency Attenuation
Bolt-in for PCB Applications
60-BHP Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
■
Ideally suited for products that must
conform to FCC part 15 regulations
Metal cased filter offers high performance
Meets over voltage of IEC 664 category II
and complies with IEC 950
Solder lug, Fast-on tab styles available (see page PF20)
PCB mounting minimizes space and provides
economical installation
Excellent filtering characteristics for high frequencies
Earth coil standard
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF49)
Circuit Diagram
1
Applications
■
■
■
■
CX
E
Digital equipment
Personal computers and peripherals
Measuring instruments
Monitor and display units
CY
L1
CY
2
3
E
4
L2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
60-BHP-010-3-11
0.35mA
60-BHP-010-3-4
0.50mA
60-BHP-010-5-4
60-BHP-020-3-11
60-BHP-020-3-4
60-BHP-030-3-4
60-BHP-030-5-11
60-BHP-060-5-4
3300pF±20%
0.35mA
2200pF±20%
0.50mA
3300pF±20%
0.35mA
2200pF±20%
3A
60-BHP-060-3-11
60-BHP-060-5-11
2200pF±20%
250VAC
60-BHP-030-5-4
60-BHP-060-3-4
Capacitance
2A
60-BHP-020-5-11
60-BHP-030-3-11
CY
1A
60-BHP-010-5-11
60-BHP-020-5-4
Leakage Current
(Max.)
0.50mA
3300pF±20%
0.35mA
2200pF±20%
0.50mA
3300pF±20%
6A
CX
Inductance
(L1)
(L2)
Temperature
Rise (Max.)
0.1uF±20%
.047uF±20%
0.1uF±20%
6mH
.047uF±20%
0.1uF±20%
.047uF±20%
0.1uF±20%
2.4mH
.047uF±20%
18.3 uH
0.1uF±20%
.047uF±20%
0.1uF±20%
30°C
1.2mH
.047uF±20%
0.1uF±20%
.047uF±20%
0.1uF±20%
0.53mH
45°C
.047uF±20%
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 50g
Input: Compatible with IEC-320
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF48
Power Entry Modules
High Frequency Attenuation
Bolt-in for PCB Applications
60-BHP Series
60-BHP
PCB
Mounting
Type
Temperature Characteristics
120
Current (%)
100
.098
(2.5)
1.967 (50)
1.573 (40)
.885
(22.5)
80
5
4.
R
2- .142
(3.6)
.059
(1.5)
.031 (.8)
1.070
(27.2)
.024
(.6)
1.573 (40)
40
.142
(3.6)
.047 (1.2)
.232 (5.9)
1.180 (30)
.865
(22)
.991
(25.2)
.590 (15)
2- .142
(3.6)
60
1.534 (39)
1.389
(35.3)
.779 1.180
(19.8) (30)
.708 (18)
Panel cutout dimensions
mounts from backside
20
Dimensions in inches (mm)
0
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
Oscillator
50Ω
60-BHP-XXX-X-11
80
Insertion Loss (dB)
50Ω
90
60-BHP-020-X-11
60
50
40
60-BHP-030-X-11
30
60-BHP-060-X-11
20
50Ω
60-BHP-XXX-3-11
70
60-BHP-010-3-11
60
50
60-BHP-020-3-11
40
60-BHP-030-3-11
30
60-BHP-060-3-11
20
10
10
0
0.1
0.2
1
0.5
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
60-BHP-XXX-X-4
Insertion Loss (dB)
80
90
60-BHP-020-X-4
60
50
40
60-BHP-030-X-4
30
60-BHP-060-X-4
20
10
20
50
60-BHP-XXX-3-4
70
60-BHP-010-3-4
60
50
60-BHP-020-3-4
40
60-BHP-030-3-4
30
60-BHP-060-3-4
20
10
10
0
0.1
5
80
60-BHP-010-X-4
70
2
Frequency (MHz)
Insertion Loss (dB)
90
50Ω
Level
Meter
50Ω
80
60-BHP-010-X-11
70
Insertion Loss (dB)
90
1
3
Filter
2
4
50Ω
Level
Meter
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF49
Power Line Filters
Appliance Filters
11-MPC Series
Features
■
■
■
■
■
Miniature general purpose PCB mounted filter
Requires minimal PCB real estate space
Low cost
Operating temperature: -25°C to +70°C
Two forms of cases are available:
metal case and plastic case
Circuit Diagram
Circuit 1
Applications
■
■
■
■
■
Personal computers and peripherals
Digital equipment
Measuring instruments and medical equipment
TV & VCR monitors and display units
Home appliances
Circuit 2
Circuit 3
Circuit 4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
11-MPC-001-2-B
Leakage Current
(Max.)
Circuit
Diagram
Figure
5uA
1
A1
1A
11-MPC-001-5-A
A
2
11-MPC-001-5-B
11-MPC-002-5-B
11-MPC-002-5-D
11-MPC-003-5-E
11-MPC-006-5-B
11-MPC-006-5-C
11-MPC-016-5-B
120/250VAC
2A
0.50mA
3A
6A
16A
Temperature Rise
(Max.)
3
2
0.2mA
4
A1
D
30°C
E
A1
C
B
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 17.5g
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF50
PCB Power Filters
Miniature Printed Circuit Board
11-MPC Series
Figure A
Figure A1
Figure B
0.6 0.9
(16) (25)
2.0
0.9
(25)±.007 (51)
0.6
(16)
0.9 (25)
10.0± 0.2
0.6
(15)
0.4
(10)
20.0±1.0
0.9 (25)
2.5 (64)
Figure C
Figure D
35.0
10.0
.60
(15)
±.07
.79 (20)
1.1 (29)
1.7 (44)
28.0
16.0
45.0
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
80
11-MPC-001-2-B
50
40
11-MPC-002-5-D
30
20
11-MPC-002-5-B
10
0.2
0.5
1
60
11-MPC-001-5-B
50
11-MPC-001-2-B
40
30
20
11-MPC-001-5-A
10
2
5
10
20
0
0.1
50
11-MPC-002-5-B
0.2
0.5
1
11-MPC-003;-006;-016
Insertion Loss (dB)
Insertion Loss (dB)
11-MPC-006-5-B
11-MPC-016-5-B
20
10
1
60
50
0.5
1
2
50
40
11-MPC-016-5-B
11-MPC-003-5-E
30
11-MPC-006-5-C
20
11-MPC-006-5-B
10
0.2
20
70
11-MPC-003-5-E
0
0.1
10
80
11-MPC-006-5-C
30
5
11-MPC-003;-006;-016
80
40
2
Frequency (MHz)
Frequency (MHz)
70
50Ω
Level
Meter
50Ω
11-MPC-002-5-D
70
11-MPC-001-5-A
Insertion Loss (dB)
60
50Ω
11-MPC-001;-002
11-MPC-001;-002
11-MPC-001-5-B
7.0
Dimensions in inches (mm)
80
70
1.4 (35.5)
1.9 (49)
Normal Mode
1
3
Filter
2
4
Insertion Loss (dB)
45.0
36.0
Common Mode
50
.15
(4)
.45
(11.5) 1.4
(35)
.45
(11.5)
10.0
1.9 (30)
.30 (7.5)
60
1.1 (27)
01 (5X)
.30 (7.5)
0
0.1
0.6 (15)
±.03
Figure E
05.0
.03 (1) (5X)
1.4 (36)
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF51
Power Line Filters
Appliance Filters
62-AL/62-AC Series
Features
■
■
■
■
■
■
■
Tested and found to be
IAW VDE 0565 Part 3
Low-cost plastic case
Compact design requires minimal real estate space
Suitable for products that must conform
to FCC regulations
Wide variety of circuit and filtering options
Good filtering characteristics for both normal mode
and common mode
Epoxy molded for reliability
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF53)
Fast-on tab #110
.629
(16.0)
1.220
(31.0)
1.573 (40.0)
.177 x .138 (4.5 x 3.5)
.371
(9.4)
.994 (24.0)
.371
(9.4)
1.527 (38.8)
.657
(16.7)
.374 (9.5)
.263 (6.7)
Dimensions in inches (mm)
Applications
Circuit Diagrams
Personal computers and peripherals
■ Digital equipment
■ Industrial equipment
■ Vending machines
■ Home appliances
■ Office equipment
■
62-AFL-010-3-11
62-AFC-010-3-11
62-AFL-010-5-11
62-AFC-010-5-11
62-AFL-016-3-11
62-AFC-016-3-11
62-AFL-016-5-11
62-AFC-016-5-11
62-AFL-030-3-11
62-AFC-030-3-11
62-AFL-030-5-11
62-AFC-030-5-11
62-AFL-045-3-11
62-AFC-045-3-11
62-AFL-045-5-11
62-AFC-045-5-11
62-AFL-060-3-11
62-AFC-060-3-11
62-AFL-060-5-11
62-AFC-060-5-11
Rated Voltage
(@ 50/60Hz)
R
CY1
CY2
CX
CY1
CY2
* R= w/ Bleeder Resistor
F = w/o Bleeder Resistor
Rated
Current
1.0A
1.6A
250VAC
CX
R
L
62-A*C
Series
Specifications
Model*
L
62-A*L
Series
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
4.5A
Inductance
(L1)
Temperature
Rise (Max.)
11.0mH
6.0mH
0.1uF
3.0A
6.0A
CX
2.4mH
40°C
1.0mH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
0.53mH
* Available with bleeder resistor
Replace F with R for part number
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF52
Temperature Characteristics
120
100
Current (%)
Power Line Filters
Appliance Filters
80
60
40
20
0
Normal
20 Mode
30
40
50
60
70
Ambient Temperature (°C)
62-AL/62-AC Series
Common Mode
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
80
62-AFL-030-3-11
Insertion Loss (dB)
Insertion Loss (dB)
62-AFL-010-3-11
50
40
30
20
62-AFL-060-3-11
10
0.5
1
2
10
5
20
60
62-AFL-010-3-11
40
30
62-AFL-030-3-11
20
62-AFL-060-3-11
0
0.1
50
0.2
80
62-AFC-030-3-11
Insertion Loss (dB)
62-AFC-010-3-11
50
40
30
20
62-AFC-060-3-11
10
0.2
0.5
1
2
10
5
20
30
62-AFC-045-3-11
62-AFC-060-3-11
20
0.2
0.5
1
70
40
30
62-AFL-045-5-11
20
62-AFL-060-5-11
10
1
2
5
10
20
62-AFL-016-5-11
60
50
20
50
62-AFL-030-5-11
50
40
30
20
62-AFL-060-5-11
10
0
0.1
50
62-AFL-045-5-11
0.2
0.5
1
2
5
10
Frequency (MHz)
62-AFC-xxx-5-11
62-AFC-xxx-5-11
80
80
70
70
62-AFC-010-5-11
Insertion Loss (dB)
Insertion Loss (dB)
20
62-AFL-010-5-11
Frequency (MHz)
60
10
62-AFL-xxx-5-11
50
0.5
5
80
62-AFL-016-5-11
62-AFL-010-5-11
0.2
2
Frequency (MHz)
62-AFL-030-5-11
0
0.1
50
62-AFC-010-3-11
40
0
0.1
50
Insertion Loss (dB)
Insertion Loss (dB)
60
20
62-AFC-016-3-11
50
62-AFL-xxx-5-11
70
10
60
Frequency (MHz)
80
5
10
62-AFC-045-3-11
0
0.1
2
62-AFC-030-3-11
70
62-AFC-016-3-11
60
1
62-AFC-XXX-3-11
62-AFC-XXX-3-11
80
70
0.5
Frequency (MHz)
Frequency (MHz)
Insertion Loss (dB)
62-AFL-016-3-11
50
10
62-AFL-045-3-11
0.2
50Ω
Level
Meter
50Ω
62-AFL-045-3-11
70
62-AFL-016-3-11
0
0.1
50Ω
62-AFL-XXX-3-11
62-AFL-xxx-3-11
80
60
90
Normal Mode
1
3
Filter
2
4
70
80
50
40
30
62-AFC-060-5-11
20
62-AFC-045-5-11
62-AFC-030-5-11
62-AFC-016-5-11
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
60
50
62-AFC-016-5-11
62-AFC-030-5-11
62-AFC-010-5-11
40
30
20
62-AFC-045-5-11
10
50
0
0.1
62-AFC-060-5-11
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF53
Power Line Filters
Single Stage
62-PPF/PQF/PRF Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
Low-cost plastic case
Compact design requires minimal real estate space
Suitable for products that must conform
to FCC and FTZ regulations
Wide variety of circuit and filtering options
Good filtering characteristics for both normal mode
and common mode
Epoxy molded for reliability
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF55)
■
■
■
■
Personal computers and peripherals
Digital equipment
Industrial equipment
Vending machines
Office equipment
62-PQF-020-5-11
62-PQF-020-5-12
62-PPF-020-5-11
62-PPF-020-5-12
62-PQF-030-5-11
62-PQF-030-5-12
62-PPF-030-5-11
62-PPF-030-5-12
62-PQF-060-5-11
62-PQF-060-5-12
62-PPF-060-5-11
62-PPF-060-5-12
62-PRF-010-5-11
62-PRF-010-5-12
62-PRF-020-5-11
62-PRF-020-5-12
62-PRF-030-5-11
62-PRF-030-5-12
Rated Voltage
(@ 50/60Hz)
CX
R
CY
CX
R
L1
L1
62-PRF*
Series
CY
CY
L1
CY
R
CX
CY
CY
* Bleeder Resistor is available only for
62-P(Q/R/P)F-XXX-X-12
Specifications
Model
L1
62-PQF*
Series
62-PPF*
Series
Applications
■
Circuit Diagrams
Rated
Current
Leakage Current
(Max.)
CY
Capacitance
2A
3A
0.50mA
250VAC
3300pF
6A
1A
2A
3A
CX
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
0.1uF
.22uF
Inductance
(L1)
Temperature
Rise (Max.)
15mH
8mH
30°C
2.1mH
486uH
181uH
97uH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. (except 62-PRF-010-5-11) at rated current
62-PRF-010-5-11: 1.5V max. at rated current
Weight: 62-PPF & PQF Series: 2.11 ounces (60 grams)
62-PRF Series: 1.76 ounces (50 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF54
Power Line Filters
Single Stage
62-PPF/PQF/PRF Series
Temperature Characteristics
Normal Mode
120
1
3
Filter
2
4
Current (%)
100
Oscillator
50Ω
80
50Ω
60
40
80
20
20
30
40
50
60
70
Ambient Temperature (°C)
80
90
Insertion Loss (dB)
70
0
Fast-on tab #110
60
62-PQF Series
62-PQF-020-5-12
50
40
62-PQF-020-5-11
30
62-PQF-060-5-12
20
62-PQF-060-5-11
10
0
0.1
.786
(20)
0.2
1
0.5
.177 x .138 (4.5 x 3.5)
1.947 (49.5)
2.006 (51)
.354
(9)
80
1.265 (32)
.590 (15)
Dimensions in inches (mm)
Also available with .250 Fast-ons
Common Mode
Oscillator
50Ω
50Ω
Insertion Loss (dB)
40
0
0.1
62-P(Q/P)-020-5-11
62-P(Q/P)-030-5-11
0.2
0.5
1
10
20
50
10
20
50
62-PPF-020-5-12
40
62-PPF-020-5-11
30
62-PPF-060-5-12
20
62-PPF-060-5-11
2
0.2
1
0.5
2
5
62-PRF Series
70
50
10
50
80
60
20
50
Frequency (MHz)
62-P(Q/P)-060-5-11
30
20
60
0
0.1
50Ω
Level
Meter
62-P(P/Q/R)F Series
70
10
62-PPF Series
10
1
3
Filter
2
4
80
5
70
.904
(23)
Insertion Loss (dB)
.354
(9)
2
Frequency (MHz)
1.573 (40)
Insertion Loss (dB)
50Ω
Level
Meter
50Ω
60
50
62-PRF-010-5-11
40
62-PRF-010-5-12
30
62-PRF-030-5-12
20
62-PRF-030-5-11
10
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF55
Power Line Filters
Single Stage Wire Leads
62-PML Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
Compact design requires minimal real estate space
Suitable for products that must conform
to FCC and FTZ regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF57)
Circuit Diagram
1
CY
L1
R
CX
CX
E
Applications
■
■
■
■
■
Digital equipment
Personal computers and peripherals
Measuring instruments
Medical equipment
Factory automation equipment
3
CY
4
2
Specifications
Model
Rated Voltage
(@ 50/60Hz)
62-PML-015-3-11
1.5A
62-PML-015-5-11
62-PML-030-3-11
62-PML-030-5-11
62-PML-050-3-11
62-PML-050-5-11
Rated
Current
250VAC
3A
5A
Leakage Current
(Max.)
CY
Capacitance
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
0.35mA
2200pF
0.50mA
3300pF
CX
Inductance
(L1)
Temperature
Rise (Max.)
10.0mH
0.1uF
4.3mH
30°C
2.4mH
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Weight: 62-PML-015 Series: 3.06 ounces (87 grams)
62-PML-030 Series: 3.17 ounces (90 grams)
62-PML-050 Series: 3.28 ounces (93 grams)
Discharge time: 0.4 sec. max.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF56
Power Line Filters
Single Stage Wire Leads
62-PML Series
BK
Temperature Characteristics
WH
G/Y
120
BK
1.219
(31)
.786
(20) 1.966
(50)
WH
100
Current (%)
1.573
(40)
PVC
Insulated wire
AWG # 20 UL1015
.629
(16)
2 — .138 x .181 (3.5 x 4.6)
.944 (24)
80
60
.395 (10)
.395
(10)
5.112* (130)
40
5.112* (130)
20
* Custom lengths available upon request. Dimensions in inches (mm)
0
20
30
40
50
60
70
80
1.856 (47.2)
90
Ambient Temperature (°C)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
Insertion Loss (dB)
50Ω
Oscillator
50Ω
62-PML
60
90
62-PML-015-5-21
40
30
62-PML-050-5-21
20
10
0
0.1
0.5
1
2
5
Frequency (MHz)
50Ω
Level
Meter
50Ω
62-PML
70
60
62-PML-050-5-11
50
40
62-PML-030-5-11
30
62-PML-015-5-11
20
0.2
50Ω
80
62-PML-030-5-21
50
Insertion Loss (dB)
80
70
1
3
Filter
2
4
50Ω
Level
Meter
10
20
50
10
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF57
Power Line Filters
Single Stage Wire Leads
for Medical Purpose Applications
12-PML & 12-PMF Series
Features
■
■
■
■
■
■
■
■
Compact design requires minimal real estate
space
Suitable for products that must conform
to FCC and FTZ regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal
mode and common mode
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -25°C to +70°C
Low leakage current
Circuit Diagram
Circuit 1
Circuit 2
Applications
■
■
■
■
■
Digital equipment
Personal computers and peripherals
Measuring instruments
Medical equipment
Factory automation equipment
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
12-PML-001-2-A
1A
12-PML-002-2-A
2A
12-PML-006-2-A
6A
12-PML-010-2-A
12-PMF-001-2-B
120/250VAC
10A
1A
12-PMF-002-2-B
2A
12-PMF-006-2-B
6A
12-PML-001-2-C
1A
Leakage Current
(Max.)
Circuit
Diagram
Figure
1
A
5uA
Temperature Rise
(Max.)
30°C
2
B
1
C
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Discharge time: 0.4 sec. max.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF58
Power Line Filters
Single Stage Wire Leads
for Medical Purpose Applications
12-PML & 12-PMF Series
Figure A
Figure C
.31 (8)
.13 (3.5) X .17 (4.5) SLOT (2 PLACES)
.13 (3.5) X .17 (4.5) SLOT (2 PLACES)
.94
(24)
1.5
(39)
1.9
(49)
1.2
(30)
1.25 (32)
1.6 (42)
1.9 (48)
1.7 (44)
.78 (20)
.78 (20)
Figure B
.14 (3.8) (2X)
1.2
(30)
1.7 (44)
.79 (20)
2.2 (56)
2.4 (61)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
80
70
70
60
50
12-PML-001-2-A
12-PML-006-2-A
40
30
20
10
12-PML-002-2-A
0
0.1
0.5
1
2
60
12-PML-002-2-A
12-PML-006-2-A
12-PML-001-2-A
50
40
30
20
12-PML-010-2-A
10
12-PML-010-2-A
0.2
5
10
20
0
0.1
50
0.2
0.5
1
2
Frequency (MHz)
70
70
12-PMF-001-2-B
12-PMF-002-2-B
40
30
20
12-PMF-006-2-B
10
0
0.1
0.5
1
2
5
Frequency (MHz)
10
60
12-PMF-001-2-B
20
50
20
50
12-PMF-002-2-B
1
50
11-PML-001-2-C
40
30
1
20
12-PMF-006-2-B
10
11-PML-001-2-C
0.2
10
12-PMF-001;-002;-006;-010
80
Insertion Loss (dB)
Insertion Loss (dB)
12-PMF-001;-002;-006;-010
50
5
Frequency (MHz)
80
60
50Ω
Level
Meter
50Ω
12-PML-001;-002;-006;-010
80
Insertion Loss (dB)
Insertion Loss (dB)
12-PML-001;-002;-006;-010
50Ω
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF59
Power Line Filters
Single Stage
62-LMF & LMB Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
Space saving, compact designs
Suitable for products that must conform
to FCC and FTZ regulations
Excellent filtering characteristics for both normal mode
and common mode
Structure provides effective shielding for noise
generated externally and internally
Metal case provides effective shielding
Rugged construction
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF61)
Circuit Diagram
1
R
■
■
■
CY
Digital equipment
Office automation equipment, such as copy
and fax machines
Computers and peripherals
Instrumentation and controls
3
CX
CX
Applications
■
CY
L1
E
4
2
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
62-LMB-030-5-11
62-LMF-030-5-11
62-LMB-050-5-11
62-LMF-050-5-11
62-LMB-080-5-11
62-LMF-080-5-11
62-LMB-100-5-11
62-LMF-100-5-11
Rated
Current
CX
Inductance
(L1)
3A
0.1uF
14mH
5A
0.1uF & .22uF
7.0mH
8A
.22uF
4.2mH
10A
.33uF
2.2mH
250VAC
Leakage Current
(Max.)
0.50mA
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max. at rated current
Discharge time: 0.4 sec. max.
Weight: 5.3 ounces (150 grams)
CY
Capacitance
Temperature
Rise (Max.)
45°C
3300pF
*62-LMF - designates Fast-on terminals
62-LMB - designates Bolt-in terminals
62-LML - wire lead in/outputs also available
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF60
Temperature Characteristics
120
100
Current (%)
Power Line Filters
Single Stage
80
60
40
20
62-LMF & LMB Series
0
30
40
50
60
70
Ambient Temperature (°C)
80
90
62-LMF
62-LMB
.708
(18.0)
20
1.10
(28.0)
1.97
(50.0)
.66
(16.8)
.66
(16.8)
.255
(6.5)
.61
(15.5)
1.10
(28.0)
.708
(18.0)
.61
(15.5)
1.97
(50.0)
2 - ø4.8
.255
(6.5)
5-M4
2.39
(60.7± 0.5)
1.22
(31.0)
1.97
(50.0)
2.39
(60.7± 0.5)
1.22
(31.0)
2.79
(70.9)
.61
(15.5)
1.97
(50.0)
2.79
(70.9)
.61
(15.5)
Fast-on Tabs #250
.031 (0.8) t
2 - ø .188
(4.8)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
90
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
62-LMF & LMB
90
80
80
60
70
62-LM-030-5-11
62-LM-050-5-11
50
40
40
30
10
0
0.1
62-LM-030-5-11
62-LM-050-5-11
60
50
20
50Ω
Level
Meter
50Ω
62-LMF & LMB
Insertion Loss (dB)
Insertion Loss (dB)
70
50Ω
62-LM-100-5-11
20
62-LM-080-5-11
0.2
0.5
10
1
2
62-LM-100-5-11
30
5
Frequency (MHz)
10
20
50
0
0.1
62-LM-080-5-11
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF61
Power Line Filters
Single Stage
62-PMF & PMB Series
Tested and found to be
IAW VDE 0565 Part 3
Features
■
■
■
■
■
■
■
■
Space-saving, compact designs
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF63)
Circuit Diagram
1
CX
CY
■
■
■
■
■
■
■
■
E
4
2
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
3
CX
R
Applications
■
CY
L1
Specifications
Model*
Rated Voltage
(@ 50/60Hz)
62-PMB-050-5-11
62-PMF-050-5-11
62-PMB-080-5-11
62-PMF-080-5-11
62-PMB-100-5-12
62-PMF-100-5-12
62-PMB-150-5-13
62-PMF-150-5-13
62-PMB-200-5-13
62-PMF-200-5-13
250VAC
Rated
Current
CX
Inductance
(L1)
5A
0.1uF
14mH
8A
.1uF
7.0mH
.22uF
4.2mH
10A
Leakage Current
(Max.)
0.50mA
CY
Capacitance
3300pF
15A
Temperature
Rise (Max.)
30°C
2.2mH
35°C
1.8mH
45°C**
.33uF
20A
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 8.82 ounces ( 250 grams)
* PMF - designates Fast-on terminals
PMB - designates Bolt-in terminals
** The temperature rise of 20 amp units can be decreased to 30°C
by mounting on 200 X 200 x 1.0(mm) steel chassis
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF62
Power Line Filters
Single Stage
62-PMF & PMB Series
62-PMF
3.291 (83.7)
B
C
Fast-on tab
#250
2.937 (74.7)
Temperature Characteristics
1.258
(32)
120
2 — .197 (5)
.610
(15.5)
62-PMB
80
.610
(15.5)
2.497 (63.5)
.315
(8)
A
3.291 (83.7)
B
5 — .157
(M4)
2.937 (74.7)
60
C
2 — .197
(5)
1.258
(32)
1.998
(50.8)
40
.649
(16.5)
20
MODEL
30
40
50
60
70
Ambient Temperature (°C)
80
90
Common Mode
1.258 .786
(32) (20)
Oscillator
50Ω
Oscillator
50Ω
90
80
62-PMB-050-5-11
Insertion Loss (dB)
Insertion Loss (dB)
62-PMB-080-5-11
50
62-PMB-100-5-12
30
62-PMB-150-5-13
20
0
0.1
0.2
0.5
1
2
50Ω
5
Frequency (MHz)
20
50
R2
R1
S1 Filter S2
T1
T2
50Ω
Level
Meter
62-PMB-200-5-13
62-PMF-050-5-11
60
50
40
62-PMF-150-5-13
30
10
10
50Ω
Level
Meter
50Ω
70
20
62-PMB-200-5-13
10
Dimensions in inches (mm)
50Ω
50Ω
50Ω
50Ω
Level
Meter
90
40
0
(0)
1
3
Filter
2
4
80
60
C
62-PMF/PMB-050-080
62-PMB-050-6
R2
R1
S1 Filter S2
T1
T2
Oscillator
50Ω
B
1.490 .944 .433
(38) (24) (11)
50Ω
Level
Meter
50Ω
62-PMB-050-6
A
62-PMF/PMB-100-200
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
.315
(8)
A
50Ω
20
50Ω
0
70
.649
(16.5)
2.497 (63.5)
50Ω
Current (%)
100
1.998
(50.8)
0
0.1
62-PMF-080-5-11
62-PMF-100-5-12
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF63
Power Line Filters
Single Stage
12-PMF Series
Features
■
■
■
■
■
■
■
■
Space-saving, compact designs
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Operating temperature: -25°C to +85°C
Circuit Diagram
Circuit 1
Circuit 2
Circuit 3
Circuit 4
Circuit 5
Circuit 6
Applications
■
■
■
■
■
■
■
■
■
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
Circuit
Diagram
Figure
12-PMF-001-5-A
1A
1
A
12-PMF-002-5-B
2A
2
B
4
A
2
B
12-PMF-003-5-A
3A
12-PMF-003-5-B
12-PMF-006-5-A
6A
12-PMF-006-5-C
12-PMF-006-5-D
12-PMF-010-5-A
12-PMF-010-5-C
12-PMF-015-5-C
12-PMF-015-5-E
120/250VAC
10A
A
1
C
6
D
2
A
3
15A
20A
12-PMF-020-5-E
30°C
C
E
5
12-PMF-020-5-C
12-PMF-020-5-D
0.5mA
4
Temperature Rise
(Max.)
C
D
E
Note: Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF64
Power Line Filters
Single Stage
12-PMF Series
Figure A
Figure B
.14 (3.8)
2 .34 (8.8)
1.2
(30)
2.4 1.8
(62) (46)
2.1
(54)
1.7 (44)
2.2 (56)
.78 (20)
3.2 (81)
1.25 (32)
2.4 (62)
.86 (22)
Figure D
Figure C
Figure E
.41 (10.5)
2 .17 (8.8)
2-
1.7 (4.5) (2X)
.18 (4.8)
2.0
(52)
2.0 (52)
2.4 (63)
1.9 2.3 2.8
(50) (60) (10.5)
1.4 (37)
2.5 3.3
(64) (85)
2.9
(74)
3.2 (82)
1.7 (44)
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
12-PMF-001;-002;-003;-006
80
12-PMF-002-5-B
12-PMF-003-5-B
12-PMF-006-5-A
40
12-PMF-003-5-A
30
20
12-PMF-006-5-C
12-PMF-006-5-D
10
12-PMF-006-5-C
12-PMF-006-5-A
60
12-PMF-006-5-D
50
40
30
12-PMF-003-5-B
20
12-PMF-003-5-A
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
12-PMF-002-5-B
0.2
0.5
1
Frequency (MHz)
12-PMF-001;-002;-003;-006
50
12-PMF-002-5-B
12-PMF-003-5-B
12-PMF-006-5-A
12-PMF-003-5-A
30
20
0
0.1
12-PMF-006-5-C
12-PMF-006-5-D
10
0.2
0.5
1
2
5
20
50
60
50
12-PMF-010-5-C
12-PMF-020-5-C
40
12-PMF-010-5-A
30
20
12-PMF-020-5-D
12-PMF-020-5-E
10
Frequency (MHz)
10
12-PMF-015-5-E
70
12-PMF-001-5-A
40
5
12-PMF-010;-015;-020
80
Insertion Loss (dB)
Insertion Loss (dB)
60
2
Frequency (MHz)
80
70
50Ω
Level
Meter
50Ω
12-PMF-001-5-A
70
12-PMF-001-5-A
Insertion Loss (dB)
Insertion Loss (dB)
50
50Ω
12-PMF-001;-002;-003;-006
80
60
1.4 (36)
3.1 (80)
Common Mode
70
2.0 (51)
1.1 (28)
2.9 (74)
10
20
50
0
0.1
1
12-PMF-015-5-C
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF65
Power Line Filters
Single Stage - Higher Current
62-PMB Series
Features
■
■
■
■
■
■
■
■
■
■
Space-saving, compact designs
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Safety agency approvals pending
Designed to be in accordance with VDE 0565 Part 3
Operating temperature: -25°C to +85°C
(including temperature rise)
Circuit Diagram
3
1
L1
CX
CY
CX
R
E
CY
L1
4
2
Applications
■
■
■
■
■
■
■
■
■
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model
Rated Voltage
(@ 50/60Hz)
62-PMB-300-5-14
Rated
Current
CY
Capacitance
0.50mA
3300pF
CX
40A
Inductance
(L1)
Temperature
Rise (Max.)
1.6mH
30A
250VAC
62-PMB-400-5-14
Leakage Current
(Max.)
.47uF
45°C
0.8mH
Note: Test voltage: 1500VAC one minute, line to earth
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 8.82 ounces (250 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF66
Power Line Filters
Single Stage - Higher Current
62-PMB Series
62-PMB-300-5-14 and 62-PMB-400-5-14
4.13 (105)
3.74 (95±.08)
3.15 (80)
3.03 (77±0.5)
0.511
(13.0)
3.70 (94)
3.85 (98)
1.022
(26.0)
5.591 (142.00)
2.049 (52.0)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
FILTER
2
1
4
2
50 ohm
50 ohm
LEVEL
METER
50 ohm
90
90
80
80
70
70
60
50
62-PMB-400-5-14
40
30
20
10
0
0.1
4
50 ohm
LEVEL
METER
50 ohm
60
50
62-PMB-300-5-14
40
30
20
62-PMB-300-5-14
3
FILTER
OSCILLATOR
50 ohm
Insertion Loss (dB)
Insertion Loss (dB)
OSCILLATOR
50 ohm
3
62-PMB-400-5-14
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF67
Power Line Filters
Single Stage - Higher Current
12-PMB Series
Features
■
■
■
■
■
■
■
■
■
Space-saving, compact designs
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Designed to be in accordance with VDE 0565 Part 3
Operating temperature: -25°C to +85°C
Circuit Diagram
Applications
■
■
■
■
■
■
■
■
■
3
1
L1
CX
CY
CX
R
L1
E
CY
4
2
Digital equipment
Computers and peripherals
Measuring instruments
Medical equipment
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters
and converters
Telecommunications equipment
Office automation equipment, such as copy
and fax machines
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
12-PMB-025-5-A
25A
12-PMB-030-5-A
30A
12-PMB-035-5-B
12-PMB-050-5-B
120/250VAC
35A
Leakage Current
(Max.)
100A
12-PMB-120-8-C
120A
1
1.0mA
Figure
Temperature Rise
(Max.)
A
0.5mA
50A
12-PMB-100-8-C
Circuit
Diagram
B
30°C
C
Note: Test voltage: 1500VAC one minute, line to earth
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 8.82 ounces (250 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF68
Power Line Filters
Single Stage - Higher Current
12-PMB Series
Figure A
1M4 STUD
(4X)
Figure B
Figure C
.17 (4.5) ±.007
(2X)
4.5±0.2 x 6.5±0.2 (4X)
M6x1 (4X)
M8 THREAD (4X)
M6 THREAD (2X)
4.5 x 6.5 SLOT (4X)
M4x0.7
2.0
(24) ±.03
2.0
(52)
0.2 (6) ±.03
84.0±2.0
44±1.0
2.5 (64) MAX
0.8 (22)
±.03
1.4 (37) MAX
19±1.0
2.9 (75) ±.01
105±2.0
100
65
115±0.5
130
50.8±0.5
98.5±2.0
38.5±2.0
3.9 (101) MAX
95.3±0.5
28
158.5±3.0
80±0.5
120
180
50
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
1
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
70
70
Insertion Loss (dB)
Insertion Loss (dB)
80
12-PMB-025-5-A
50
40
30
12-PMB-035-5-B
20
12-PMB-030-5-A
10
0
0.1
0.2
0.5
1
2
60
50
12-PMB-025-5-A
40
12-PMB-030-5-A
30
20
10
10
5
12-PMB-035-5-B
20
0
0.1
50
0.2
0.5
1
70
70
12-PMB-100-8-C
50
40
30
12-PMB-050-5-B
12-PMB-120-8-C
10
0
0.1
0.2
0.5
1
2
10
5
20
50
12-PMB-050;-100;-120
80
Insertion Loss (dB)
Insertion Loss (dB)
12-PMB-050;-100;-120
80
20
2
Frequency (MHz)
Frequency (MHz)
60
50Ω
Level
Meter
50Ω
12-PMB-025;-030;-035
12-PMB-025;-030;-035
80
60
50Ω
5
Frequency (MHz)
10
20
12-PMB-050-5-B
60
50
1
12-PMB-120-8-C
40
12-PMB-100-8-C
30
20
10
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF69
Power Line Filters
DC - Higher Current
12-PMF & 12 PMB DC Series
Features
■
■
■
■
■
■
■
■
■
Space-saving, compact designs
Suitable for products that must conform to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective shielding
Excellent filtering characteristics for both normal mode
and common mode
Epoxy molded for internal component reliability
Structure provides effective shielding for noise
generated externally and internally
Designed to be in accordance with VDE 0565 Part 3
Operating temperature: -40°C to +85°C
Circuit Diagram
Circuit 1
Circuit 2
Applications
■
■
■
■
■
■
■
Digital equipment
Computers and peripherals
Measuring instruments
Equipment requiring very high impulse attenuation
Factory automation equipment
Industrial equipment such as UPS, inverters and converters
Telecommunications equipment
Circuit 3
Specifications
Model
12-PMF-006-DC-C
12-PMF-010-DC-C
12-PMF-015-DC-C
12-PMF-020-DC-C
12-PMF-025-DC-D
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
12-PMB-080-DC-G
12-PMB-080-DC-C
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
Rated Voltage
(@ 50/60Hz)
Rated
Current
Circuit
Diagram
6A
10A
15A
20A
B
1
C
40A
48/250
VDC
50A
60A
80A
100A
120A
140A
180A
200A
260A
Note: Test voltage: 1500VAC one minute, line to earth
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Temperature Rise
(Max.)
A
25A
30A
35A
Figure
D
2
3
2
30°C
E
F
G
Discharge time: 0.4 sec. max.
Weight: 8.82 ounces (250 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF70
Figure A
Power Line Filters
DC - Higher Current
12-PMF & 12-PMB DC Series
Figure B
Figure C
Figure D
Figure F
Figure G
4.8 (2X)
20.0±1.0
4.0±1.0
10.5±0.5
44.0±1.0
50.0±1.0
8.0±1.0
10.0±1.0
60.0±0.5
28.5±1.0
70.5±1.0
Figure E
1.9 (50)
±.003
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
1
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
1
12-PMF-006;-010;-015;-020;-025
Insertion Loss (dB)
70
12-PMF-006;-010;-015;-020;-025
50
12-PMF-025-DC-D
40
30
12-PMF-015-DC-C
20
12-PMF-020-DC-C
10
0
0.1
0.2
0.5
1
12-PMF-025-DC-D
70
12-PMF-010-DC-C
60
2
5
10
60
12-PMF-020-DC-C
50
12-PMF-010-DC-C
40
12-PMF-015-DC-C
30
12-PMF-006-DC-C
20
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
12-PMB-080-DC-G
12-PMB-080-DC-C
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
50
40
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
30
20
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
10
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
5
10
20
50
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
10
20
12-PMB-025; thru -260
70
Insertion Loss (dB)
60
80
60
50
12-PMB-025-DC-F
12-PMB-030-DC-F
12-PMB-035-DC-F
12-PMB-040-DC-F
50
40
30
20
10
I
Insertion Loss (dB)
70
2
Frequency (MHz)
12-PMB-025; thru -260
80
50Ω
Level
Meter
50Ω
80
12-PMF-006-DC-C
Insertion Loss (dB)
80
50Ω
0
0.1
12-PMB-180-DC-E
12-PMB-200-DC-E
12-PMB-260-DC-E
0.2
0.5
12-PMB-080-DC-G
12-PMB-080-DC-C
12-PMB-040-DC-B
12-PMB-050-DC-B
12-PMB-060-DC-B
1
2
12-PMB-100-DC-C
12-PMB-120-DC-C
12-PMB-140-DC-C
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF71
Power Line Filters
Dual Stage
62-MMF Series
Features
■
■
■
■
■
■
■
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Two stages for excellent filtering characteristics
Epoxy molded for reliability
Structure provides effective shielding for noise
generated both externally and internally
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF73)
Circuit Diagram
62-MMF-XXX-7-11
1
L1
CX
R
Applications
■
■
■
■
■
CX
CY
L1
CY
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
CX
CY
CY
2
3
E
4
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
CY1
Capacitance
CY2
CX
Inductance
(L1) (2X)
Temperature
Rise (Max.)
62-MMF-030-7-11
250VAC
3A
.7mA
3300pF
1000pF
0.1uF
3.7mH
30°C
62-MMF-050-7-11
250VAC
5A
.7mA
3300pF
1000pF
0.1uF
2.9mH
30°C
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF72
Power Line Filters
Dual Stage
62-MMF Series
Temperature Characteristics
3.291 (83.7)
120
.786 (20)
.315
(8)
Fast-on tab
#250
2.937 (74.7)
Current (%)
100
80
.315
(8)
1.258
(32)
2 – .197 (5)
1.998
(50.8)
60
40
.610
(15.5)
.610
(15.5)
2.497 (63.5)
1.258 (32)
20
Dimensions in inches (mm)
0
20
30
40
50
60
70
80
90
Ambient Temperature (°C)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
50Ω
Oscillator
50Ω
62-MMF
90
80
80
70
70
60
Insertion Loss (dB)
Insertion Loss (dB)
90
1
3
Filter
2
4
50Ω
Level
Meter
62-MMF-050-7-11
50
62-MMF-030-7-11
40
30
20
50Ω
Level
Meter
50Ω
62-MMF
60
62-MMF-050-7-11
50
62-MMF-030-7-11
40
30
20
10
0
0.1
50Ω
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF73
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Features
■
■
■
■
■
■
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Two stages for excellent filtering characteristics
Structure provides effective shielding for noise
generated both externally and internally
Operating temperature: -40°C to +85°C
■
High performance
■
Low leakage current
Applications
■
■
■
■
■
■
Digital equipment
Switching power supplies
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Circuit Diagram
Circuit 1
Circuit 2
Circuit 3
Specifications
Model
12-MMF-002-5-F
12-MMF-003-5-F
12-MMF-003-5-A
12-MMF-006-5-F
12-MMF-006-5-G
12-MMF-008-5-B
12-MMF-010-5-F
12-MMF-010-5-G
12-MMF-010-5-B
12-MMF-012-5-B
12-MMB-015-5-E
12-MMB-020-5-F
12-MMB-030-5-D
12-MMB-050-5-C
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage
Current (Max.)
2A
Circuit
Diagram
1
3A
3
6A
10A
Temperature Rise
(Max.)
A
A
B
A
C
8A
120/250VAC
Figure
A
A1
0.25mA@120VAC/
0.5mA@250VAC
2
12A
15A
20A
30A
50A
30°C
C
D
G
E
F
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF74
Figure A
Power Line Filters
Dual Stage
Figure A1
1.42 (36)
12-MMF & 12-MMB Series
Figure B
Figure C
Ø .15 (3.8) (2X)
M4 STUD (7X)
2.24
(57)
2.12
(54)
1.81 2.44
(46) (62)
.21 (5.4) X .37 (9.4) HOLE (4X)
3.38 1.65
(86) (42)
2.40 .007
(60 .2)
2.90 (73)
2.42 (87)
4.01 (102)
1.77 (45)
1.26 (32)
.87 (22)
Figure D
Ø .25 (6.4) (2X)
2.44 (62)
.71 (18)
1.50 (38)
6.30 (160)
7.24 (184)
7.95 (202)
2.30 (58)
Figure E
M4 THREAD (5X)
Figure F
.117 (4.5) X .25 (6.3) SLOT (4X)
Figure G
M4 THREAD
M4 THREAD (5X)
M6 THREAD (4X)
4.5 x 6.5 (2X)
57
3.30 3.74 4.13
(84) (95) (105)
3.93 4.52 5.12
(100) (115) (130)
1.97 (50)
3.15 (80)
4.72 (120)
7.09 (180)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
70
70
60
12-MMF-002-5-F
50
12-MMF-003-5-F
40
12-MMF-006-5-F
12-MMF-006-5-G
30
50Ω
0
12-MMF-008-5-B
10
12-MMF-006-5-G
60
12-MMF-002-5-F
50
12-MMF-003-5-A
0.05
0.15 0.45 1
2
5
10
20
40
12-MMF-008-5-B
30
20
12-MMF-003-5-A
0
0.01
50
0.05
0.15 0.45 1
Frequency (MHz)
80
70
70
1
12-MMB-030-5-D
12-MMB-050-5-C
40
12-MMB-015-5-E
12-MMF-010-5-F
12-MMF-010-5-G 12-MMB-020-5-F
12-MMF-010-5-B
12-MMF-012-5-B
30
20
10
0
0.01
0.05
0.15 0.45 1
2
5
Frequency (MHz)
10
20
50
Insertion Loss (dB)
Insertion Loss (dB)
12-MMF-010;-012;-015;-020;-030;-050
50
2
5
10
20
50
Frequency (MHz)
80
60
12-MMF-006-5-F
12-MMF-003-5-F
10
0
0.01
50Ω
Level
Meter
50Ω
12-MMF-002;-003;-006;-008
80
Insertion Loss (dB)
Insertion Loss (dB)
12-MMF-002;-003;-006;-008
80
20
73
87
109 MAX
45
2.01 (51)
3.88 (98.5)
5.31 (135)
1.51 (38.5)
12-MMF-010;-012;015;-020;-030;-050
12-MMB-050-5-C
60
50
40
12-MMB-030-5-D
30
12-MMF-010-5-F
12-MMF-010-5-G
12-MMF-010-5-B
12-MMF-012-5-B
12-MMB-015-5-E
12-MMB-020-5-F
20
10
0
0.01
0.05
0.15 0.45 1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF75
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Features
■
■
■
■
■
■
■
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Two stages for excellent filtering characteristics
Structure provides effective shielding for noise
generated both externally and internally
Operating temperature: -40°C to +85°C
Circuit Diagram
Circuit 1
High performance
Applications
■
■
■
■
■
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Circuit 2
Specifications
Model
12-MMF-003-11-F
12-MMF-006-11-F
12-MMF-010-11-F
12-MMB-015-11-G
12-MMB-020-11-D
12-MMB-030-11-D
12-MMB-040-11-B
12-MMB-040-11-E
12-MMB-050-11-H
Rated Voltage
(@ 50/60Hz)
120/250VAC
Rated
Current
3A
6A
10A
15A
20A
30A
Leakage
Current (Max.)
Circuit
Diagram
Figure
1
A
Temperature Rise
(Max.)
C
1.5mA
40A
50A
1
2
1
B
30°C
D
E
F
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF76
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Figure A
Figure C
Figure B
04.5 ±0.2 x
7.0 ±0.2,
4 PLCS.
M4 THREAD,
2 PLCS.
3.74
1.73 3.33
± .02
± .04 MAX
(44 ± 1) (84.5) (95 ± 0.5)
.75 ± .04 (19 ± 1)
1.53 MAX (39)
Figure D
.25 (6.4) x .37(9.4) SLOT (4X)
2.28
(58)
M4 THREAD
M6 THREAD,
4 PLCS.
58 (2.283)
±0.5
103 (4.055) ±2
144 (5.669) ±0.5
160 (6.299) ±2
190 (7.480) ±3
60 (2.362)
±2
Figure F
M6 THREAD (4X)
4.5±0.2 x 6.5±0.2 SLOT (4X)
.165 (4.2) X .25 (6.4) (4X)
M8 THREAD (4X)
84.0±2.0
3.54 5.90
(90) (150)
1.77 (45)
70 (2.756)
±2
40 (1.575)
±1
30 (1.181) ±1
2.01 ± .02
(51 ± 0.5)
3.90 MAX (99)
6.20 MAX (157)
Figure E
M6 THREAD (5X)
3.54
(90)
4.13
MAX
(105)
44±1.0
8.66 (220)
9.57 (243)
10.27 (261)
95.3±0.5
19±1.0
3.93 4.53 5.12
(100) (115) (130)
105±2.0
50.8±0.5
38.5±2.0
1.97
(50)
98.5±2.0
158.5
3.14 (80)
4.72 (120)
7.08 (180)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
12-MMF/MMB-003;-006;-010;-012;-015
Insertion Loss (dB)
105
90
120
12-MMF-003-11-F
1
75
60
12-MMF-006-11-F
45
30
15
0
0.1
12-MMF-010-11-F
12-MMB-015-11-G
0.2
0.5
1
12-MMF-012-11-A
12-MMF-003-11-F
90
75
60
45
12-MMB-015-11-G
30
12-MMF-006-11-F
15
2
5
10
20
0
50
12-MMF-010-11-F
0.1
0.2
0.5
1
Frequency (MHz)
120
105
90
75
60
45
30
12-MMB-040-11-E
15
0
12-MMB-030-11-D
0.1
0.2
0.5
1
5
Frequency (MHz)
10
20
50
10
12-MMB-040-11-B
90
75
60
45
12-MMB-050-11-H
30
12-MMB-040-11-E
15
12-MMB-050-11-H
2
5
12-MMB-020;-030;-040;-050
120
12-MMB-020-11-D
Insertion Loss (dB)
Insertion Loss (dB)
105
2
Frequency (MHz)
12-MMB-020;-030;-040;-050
12-MMB-040-11-B
50Ω
Level
Meter
50Ω
12-MMF/MMB-003;-006;-010;-012;-015
105
12-MMF-012-11-A
Insertion Loss (dB)
120
50Ω
20
50
0
12-MMB-030-11-D
12-MMB-020-11-D
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF77
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Features
■
■
■
■
■
■
■
Suitable for products that must conform
to FCC regulations
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Two stages for excellent filtering characteristics
Epoxy molded for reliability
Structure provides effective shielding for noise
generated both externally and internally
Operating temperature: -25°C to +85°C
Circuit Diagram
Circuit 1
Applications
■
■
■
■
■
Digital equipment
Personal computers and peripherals
Measuring instruments and medical equipment
Telecommunications equipment
Equipment requiring very high noise attenuation
Circuit 2
Circuit 3
Specifications
Model
12-MMF-001-5-F
12-MMF-003-5-G
12-MMF-003-2-G
12-MMF-006-5-G
12-MMB-010-5-D
12-MMB-015-5-E
12-MMB-020-5-E
12-MMB-030-5-E
Rated Voltage
(@ 50/60Hz)
Rated
Current
1A
3A
120/250VAC
6A
10A
15A
20A
30A
Leakage
Current (Max.)
Circuit
Diagram
0.5mA
3
5uA
1
Figure
A
B
C
0.5mA
Temperature Rise
(Max.)
30°C
2
D
Note: All types are designed to meet the requirement of UL 1283, CSA 22.2. VDE 0565-3
Test voltage: 1500VAC one minute, line to ground
Insulation resistance: 300 Mohm min. at 500VDC
Leakage current: 0.7 mA max.
Voltage drop: 1V max.
Discharge time: 0.4 sec. max.
Weight: 6.0 ounces (170 grams)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF78
Power Line Filters
Dual Stage
12-MMF & 12-MMB Series
Figure B
Figure A
2.01
(51)
2.52 (64)
2.95 (75)
3.70 (94)
1.06 (27)
Figure C
M4 THREAD (5X)
Figure D
.25 (6.4) .37 (9.4) HOLE (4X)
M4 STUD (7X)
3.33
1.73 ± .03 (84.5)
(44 ± 1)
MAX
3.74 ± .02
(95 ± 0.5)
4.13 MAX.
(64)
0.75 ± .03 (19 ± 1)
2.36 ± .007
(60 ± .2)
3.38 1.65
(86) (42)
2.01 ± .02
(51 ± .05)
1.52 (39)
MAX
2.28 (58)
3.15 (99) MAX
5.31 (135) MAX
Common Mode
1
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
12-MMF-001;-003;-006
120
Insertion Loss (dB)
Insertion Loss (dB)
90
75
60
45
30
12-MMF-003-2-G
15
0
0.1
0.2
0.5
12-MMF-001-5-F
1
2
12-MMF-003-2-G
90
75
60
12-MMF-003-5-G
45
30
12-MMF-001-5-F
15
10
5
20
0
50
0.1
0.2
0.5
1
Frequency (MHz)
120
12-MMB-010-5-D
12-MMB-015-5-E
105
12-MMB-020-5-E
90
75
60
12-MMB-030-5-E
45
30
10
20
50
12-MMB-010-5-D
12-MMB-015-5-E
12-MMB-020-5-E
90
75
12-MMB-030-5-E
60
45
30
15
15
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
I
0
5
12-MMB-010;-015;-020;-030
120
Insertion Loss (dB)
Insertion Loss (dB)
105
2
Frequency (MHz)
12-MMB-010;-015;-020;-030
1
50Ω
Level
Meter
50Ω
12-MMF-006-5-G
105
12-MMF-003-5-G
50Ω
12-MMF-001;-003;-006
120
12-MMF-006-5-G
105
Dimensions in inches (mm)
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
7.09 (180)
7.24 (184)
7.95 (202)
.71 (18)
1.50 (38)
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF79
Power Line Filters
Three Phase
Low Current/High Performance
62-PMB/63-PMF Series
Features
■
■
■
■
■
■
■
■
■
Excellent attenuation for high voltage impulse
Effective for both balanced and unbalanced
three-phase loads
Metal case provides effective EMI shielding
Epoxy molded for internal component reliability
Compact and economical
Excellent filtering characteristics for both normal
and common mode
Various current ratings available: 3, 5, 8 and 16 Amps
Safety agency approvals pending
Operating temperature: -25°C to +85°C
(including temperature rise, see graph on page PF81)
■
■
■
62-PMB-050-6-12 (5 Amp Delta)
L
L
L
L
CX
CX
CY
CX
L
CY
L
CY
63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp Wye)
Applications
■
Circuit Diagram
CX
L
Digital equipment
Industrial equipment (UPS, inverters and converters)
Automation equipment
Computerized washing machines
L
CY
CX
L
CY
CX
CY
L
CY
63-PMF-160-9-21 (16 Amp Wye)
L
L
L
CX
CX
CX
L
CY
CX CX CX
CY
Specifications
Model
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage Current
(Max.)
CY
62-PMB-050-6-12
250VAC
5A
0.6mA
3A
63-PMF-030-8-14
63-PMF-080-8-14
63-PMF-160-9-21
480VAC
8A
16A
Capacitance
CX
Inductance
(L1)
Temperature
Rise (Max.)
2200pF
0.22uF
115mH
45°C
1.0mA
4700pF (4X)
470uF (3X)
3.0mA
0.015uF (2X)
1.0uF (6X)
1.0mH (4X)
30°C
0.74mH (4X)
40°C
1.2mH (4X)
45°C
Note: Test Voltage 1500VAC one minute, line to ground.
Insulation Resistance: 300 MΩ min. at 500VDC.
Voltage Drop: 1V max. at rated current.
Weight: 8.82 ounces (250 grams) for 63-PMF-030-8-14 and 63-PMF-080-8-14
19.4 ounces (550 grams) for 62-PMB-050-6-12
51.5 ounces (1450 grams) for 63-PMF-160-9-21
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF80
Temperature Characteristics
Power Line Filters
Three Phase
Low Current/High Performance
62-PMB/63-PMF Series
62-PMB-050-6-12 (5 Amp)
5 — .157
(M4)
.865 (22)
2.753
(70)
3.460 3.539
(88) (90)
.865 (22)
.039 (1)
* General .944 (24)
tolerance
±.020 (0.5)
1.376
(35)
63-PMF-030-8-14 and 63-PMF-080-8-14 (3 and 8 Amp)
4.444 (113)
4.050 (103)
Fast-on
tab #250
2 - .197
(ø5) Hole
.547
(13.9)
.547
(13.9)
3.585 (91.2)
.629
(16)
.708
(18)
BL
BK
BL
1.809
(46)
Dimensions in inches (mm)
BK
.208
(5.3)
.350 (8.9)
.362
(9.2)
4.404
(112) .350 (8.9)
.350 (8.9)
4.286
(109)
Fast on
tab #250
(Ground
tab)
3.146
(80.0±0.5)
5.112 (130.0)
5.702 (145 ± 0.5)
6.292 (160)
Common Mode
4 - .216
(ø5.5) Hole
Fast on
tab #250
2.045
(52)
.983
(25)
63-PMF-160-9-21 (16 Amp)
* General
tolerance
±..059 (1.5)
1.494 (38)
2.359 (60)
.708
(18)
Normal Mode
62-PMB-050-6-12 (5 Amp)
62-PMB-050-6-12 (5 Amp)
63-PMF (3, 8 and 16 Amp)
63-PMF (3, 8 and 16 Amp)
63-PMF-160-9-21
63-PMF-160-9-21
63-PMF-080-8-14
63-PMF-030-8-14
63-PMF-030-8-14
63-PMB-050-8-12
63-PMF-080-8-14
63-PMB-050-8-12
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF81
Power Line Filters
Three Phase
13-PWF/PWL/PWB Series
Features
■
■
■
■
■
■
■
■
Excellent attenuation for high voltage impulse
Effective for both balanced and unbalanced
three-phase loads
Metal case provides effective EMI shielding
Epoxy molded for internal component reliability
Suitable for both Wye and Delta connection
Excellent filtering characteristics for both normal
and common mode
Operating temperature: -40°C to +85°C
Circuit Diagram
Circuit 1
■
■
■
A'
B
B'
C
C'
N
G
N'
Designed for 3-phase 4-line power supply systems
Applications
■
A
Digital equipment
Industrial equipment (UPS, inverters and converters)
Automation equipment
Computerized washing machines
Circuit 2
A
A'
B
B'
C
C'
N
G
N'
Specifications
Model
13-PWF-005-12-H
13-PWL-005-12-C
13-PWF-010-12-H
13-PWL-010-12-C
13-PWB-010-12-D
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
13-PWB-030-12-D
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage
Current (Max.)
Circuit
Diagram
Figure
1
A
B
A
B
5A
10A
1.5mA
440/250VAC
15A
20A
25A
30A
Temperature Rise
(Max.)
30°C
2
C
Note: Test Voltage 1500VAC one minute, line to ground.
Insulation Resistance: 300 MΩ min. at 500VDC.
Voltage Drop: 1V max. at rated current.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF82
Figure B
Power Line Filters
Three Phase
13-PWF/PWL/PWB Series
Figure A
Figure C
2.0 (51)
3.9 (98.5)
5.3 (135)
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
13-PWF-005;-010;-PWL-005;-010;-PWB-010
80
Insertion Loss (dB)
Insertion Loss (dB)
50
40
30
13-PWF-010-12-H
13-PWL-010-12-C
13-PWB-010-12-D
20
10
0
0.1
13-PWB-010-12-D
70
60
60
50
40
13-PWF-005-12-H
13-PWL-005-12-C
30
20
13-PWF-010-12-H
13-PWL-010-12-C
10
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
13-PWB-015;-020;-025:-030
40
30
13-PWB-030-12-D
20
10
0
0.1
10
20
50
10
20
50
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
70
Insertion Loss (dB)
Insertion Loss (dB)
50
5
13-PWB-015;-020;-025:-030
80
13-PWB-015-12-D
13-PWB-020-12-D
13-PWB-025-12-D
60
2
Frequency (MHz)
80
70
50Ω
Level
Meter
50Ω
13-PWF-005;-010;-PWL-005;-010;-PWB-010
80
13-PWF-005-12-H
13-PWL-005-12-C
70
50Ω
1
60
50
40
13-PWB-030-12-D
30
20
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF83
Power Line Filters
Three Phase
High Performance
13-PDF/PDL/PDB Series
Features
■
■
■
■
■
■
■
■
Excellent attenuation for high voltage impulse
Effective for both balanced and unbalanced
three-phase loads
Metal case provides effective EMI shielding
Epoxy molded for internal component reliability
Compact and economical
Excellent filtering characteristics for both normal
and common mode
Operating temperature: -40°C to +85°C
Circuit Diagram
Circuit 1
■
■
■
A'
B
B'
C
C'
Designed for 3-phase, 3-Delta connection system
Applications
■
A
Digital equipment
Industrial equipment (UPS, inverters and converters)
Automation equipment
Switching power supplies
G
Circuit 2
A
A'
B
B'
C
C'
G
Specifications
Model
13-PDF-005-11-J
13-PDL-005-11-D
13-PDF-010-11-J
13-PDL-010-11-D
13-PDB-010-11-D
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
13-PDB-030-11-D
Rated Voltage
(@ 50/60Hz)
Rated
Current
Leakage
Current (Max.)
Circuit
Diagram
Figure
1
A
B
A
B
5A
10A
1.5mA
440/250VAC
15A
20A
25A
30A
Temperature Rise
(Max.)
30°C
2
C
Note: Test Voltage 1500VAC one minute, line to ground.
Insulation Resistance: 300 MΩ min. at 500VDC.
Voltage Drop: 1V max. at rated current.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF84
Figure B
Ø .177 (4.5) (2X)
Power Line Filters
Three Phase
2.00
(51)
High Performance
13-PDF/PDL/PDB Series
2.52 (64)
1.06
(27)
2.95 (75)
3.35 (85)
Figure A
Figure C
Ø .177 (4.5) (2X)
95.3±0.5
2.52 2.91 3.35
(64) (74) (85)
1.42
(36)
6.5±0.2 (4X)
4.5±0.2 (4X)
M4 THREAD (8X)
50.0±1.0
12.5±1.0
2.00
(51)
84.0±2.0 105.0±2.0
11.5±1.0
26.5±1.0
50.8±0.5
98.5±2.0
38.5±2.0
3.15 (80)
134.5±3.0
Dimensions in inches (mm)
Common Mode
Normal Mode
1
3
Filter
2
4
Oscillator
50Ω
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
Oscillator
50Ω
13-PDF-005;-010; PDL-005;-010 PDB-010
80
Insertion Loss (dB)
Insertion Loss (dB)
13-PDB-010-11-D
70
60
50
40
13-PDB-010-11-D
30
13-PDF-010-11-J
13-PDL-010-11-D
20
10
60
50
13-PDF-010-11-J
13-PDL-010-11-D
40
30
13-PDF-005-11-J
13-PDL-005-11-D
20
10
0
0.1
0.2
0.5
1
2
5
10
20
0
0.1
50
0.2
0.5
1
Frequency (MHz)
13-PDB-015;-020;-025:-030
70
40
30
13-PDB-030-11-D
20
10
0
0.1
10
20
50
10
20
50
13-PDB-015;-020;-025:-030
Insertion Loss (dB)
Insertion Loss (dB)
50
5
80
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
60
2
Frequency (MHz)
80
70
50Ω
Level
Meter
50Ω
13-PDF-005;-010; PDL-005;-010 PDB-010
80
13-PDF-005-11-J
13-PDL-005-11-D
70
50Ω
13-PDB-030-11-D
60
50
40
13-PDB-015-11-D
13-PDB-020-11-D
13-PDB-025-11-D
30
20
10
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF85
Power Line Filters
Three Phase
High Performance
13-PWB Series
Features
■
■
■
■
■
■
■
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Circuit
Epoxy molded for internal component reliability
Excellent filtering characteristics for both normal
and common mode
Circuit 1
Various current ratings available: from 5 to 150 Amps
A
Operating temperature: -40°C to +85°C
Designed for 3-phase, 4-line power systems
Applications
■
■
■
■
Power supplies for data systems
Industrial equipment (UPS, inverters and converters)
Automation equipment
Telecommunications systems and equipment
Diagram
A'
B
B'
C
C'
N
G
N'
Circuit 2
A
A'
B
B'
C
C'
N
G
N'
Specifications
Model
13-PWB-005-12-A
13-PWB-010-12-B
13-PWB-020-12-B
13-PWB-035-12-C
13-PWB-050-13-C
13-PWB-080-14-D
13-PWB-100-14-D
13-PWB-150-14-E
Rated Voltage
(@ 50/60Hz)
Rated
Current
480/277VAC
5A
10A
20A
35A
50A
80A
100A
150A
Leakage
Current (Max.)
Circuit
Diagram
4.5mA
1
30°C
9.0mA
20mA
Temperature Rise
(Max.)
2
Note: Test Voltage 1500VAC one minute, line to ground.
Insulation Resistance: 300 MΩ min. at 500VDC.
Voltage Drop: 1V max. at rated current.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF86
H
Power Line Filters
Three Phase
P
M E
F D
High Performance
I
L
13-PWB Series
K
B
A
C
G
N
J
Dimensions
Dimensions in inches (mm)
A
Model
B
C
13-PWB-005-12-A 7.2 (184) 6.3 (160) 7.9 (202)
13-PWB-010-12-B
13-PWB-020-12-B
13-PWB-035-12-C
9.6
(243)
8.7
(220)
10.3
(261)
13-PWB-100-14-D
13-PWB-150-14-E
13.9
(354)
12.6
(320)
E
2.4
(60)
1.7
(44)
3.1
(81)
13-PWB-050-13-C
13-PWB-080-14-D
D
3.9
(99)
15.1
(384)
F
G
H
I
3.5 (86) .70 (18) 2.3 (58)
3.9
(100)
3.8
(96)
4.9
(125)
6.1
(155)
7.3
(185)
M4
.98
(25)
3.5
(90)
M6
1.2
(30)
M8
7.5 (190) 8.7 (220) 1.4 (35) 3.9 (100)
Oscillator
50Ω
50Ω
13-PWB-020-12-A
13-PWB-035-12-A
13-PWB-005-12-A
0.2
0.5
1
–
–
–
M4
2.9
(74)
1.9
(49)
.25 x .37 (6.4 x 9.4)
2.4
(62)
M4
2
5
10
20
.25 x .36 (6.4 x 9.11)
50Ω
50Ω
Level
Meter
50Ω
13-PWB-010-12-A
13-PWB-005-12-A
13-PWB-020-12-A
75
60
13-PWB-035-12-A
45
30
0.1
0.2
0.5
1
2
5
10
20
50
13-PWB-050;-080;-100;-150
120
75
13-PWB-150-14-E
13-PWB-050-13-C
45
30
15
13-PWB-080-14-D
13-PWB-100-14-D
105
Insertion Loss (dB)
Insertion Loss (dB)
.25 x .36 (6.4 x 9.10)
Frequency (MHz)
13-PWB-100-14-D
90
0
.25 x .39 (6.4 x 9.9)
M8
2.4 (61)
90
0
50
13-PWB-080-14-D
60
.25 x .38 (6.4 x 9.8)
15
13-PWB-050;-080;-100;-150
105
.25 x .38 (6.4 x 9.7)
M6
2.2
(56)
3.4
(86)
Frequency (MHz)
120 1
.25 x .37 (6.4 x 9.5)
.25 x .38 (6.4 x 9.6)
2.3
(58)
105
90
0
0.1
L
13-PWB-005;-010;-020;-035
120
13-PWB-010-12-A
15
P
Oscillator
50Ω
Insertion Loss (dB)
Insertion Loss (dB)
105
30
N
1
3
Filter
2
4
13-PWB-005;-010;-020;-035
45
1.8
(45)
50Ω
Level
Meter
120
60
M
Normal Mode
1
3
Filter
2
4
75
K
1.5 (38)
Common Mode
1
J
90
75
13-PWB-050-13-C
60
45
13-PWB-150-14-E
30
15
0.1
0.2
0.5
1
2
5
Frequency (MHz)
10
20
50
0
0.1
0.2
0.5
1
2
5
10
20
50
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF87
Power Line Filters
Three Phase
High Performance
13-PDB Series
Features
■
■
■
■
■
■
■
Excellent attenuation for high voltage impulse
Metal case provides effective EMI shielding
Epoxy molded for internal component reliability
Excellent filtering characteristics for both normal
and common mode
Various current ratings available: from 5 to 200 Amps
Operating temperature: -40°C to +85°C
Designed for 3-phase, 3-line connection systems
Applications
■
■
Digital equipment
Industrial equipment (UPS, inverters and converters)
Circuit Diagram
Circuit 1
A
A'
B
B'
C
C'
G
Circuit 2
A
A'
B
B'
C
C'
G
Specifications
Model
13-PDB-005-12-A
13-PDB-010-12-A
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-050-12-B
13-PDB-080-13-C
13-PDB-100-14-C
13-PDB-150-14-C
13-PDB-200-14-D
Rated Voltage
(@ 50/60Hz)
Rated
Current
480/277VAC
5A
10A
20A
35A
50A
80A
100A
150A
200A
Leakage
Current (Max.)
Circuit
Diagram
Temperature Rise
(Max.)
4.5mA
1
30°C
9.0mA
20mA
2
Note: Test Voltage 2250VDC one minute, line to ground.
Insulation Resistance: 500MΩ.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF88
Power Line Filters
Three Phase
F D
High Performance
I
L
P
H
M E
13-PDB Series
B
A
C
G
N
J
K
Dimensions
Model
A
B
C
D
E
F
G
H
I
J
K
M
N
Dimensions in inches (mm)
P
L
13-PDB-005-12-A
7.2
(184)
6.3
(160)
7.9
(202)
1.6
(42)
2.4
(60)
3.3
(86)
.70
(18)
2.3
(58)
M4
1.5
(38)
–
–
–
M4
9.6
(243)
8.7
(220)
10.3
(261)
2.3
(58)
2.7
(70)
3.9
(100)
.98
(25)
M6
2.3
(58)
1.9
(49)
M6
6.1
(155)
7.3
(185)
1.2
(30)
13-PDB-010-12-A
13-PDB-020-12-B
13-PDB-035-12-B
13-PDB-050-12-B
13-PDB-080-13-C
13-PDB-100-14-C
13.9
(354)
13-PDB-150-14-C
12.6
(320)
15.1
(384)
2.5
(66)
13-PDB-200-14-D
3.5
(90)
M8
Oscillator
50Ω
Oscillator
50Ω
13-PDB-005;-010;-020;-035
120
120
90
75
13-PDB-035-12-B
13-PDB-005-12-A
0.01
0.02
.1
1
10
13-PDB-005;-010;-020;-035
13-PDB-010-12-A
13-PDB-005-12-A
75
60
45
13-PDB-035-12-B
30
13-PDB-020-12-B
15
20
30
0
0
60
0.01
0.02
.1
Frequency (MHz)
13-PDB-050;-080;-100;-150;-200
90
1
120
105
13-PDB-100-14-C
13-PDB-050-12-B
13-PDB-080-13-C
75
60
45
13-PDB-150-14-C
30
13-PDB-200-14-D
15
0
0
Insertion Loss (dB)
Insertion Loss (dB)
105
0.01
0.02
.1
1
10
Frequency (MHz)
1
10
20
30
60
Frequency (MHz)
13-PDB-050;-080;-100;-150;-200
13-PDB-100-14-C
13-PDB-050-12-B
90
13-PDB-200-14-D
75
60
45
13-PDB-080-13-C
30
13-PDB-150-14-C
15
20
30
60
I
120
50Ω
Level
Meter
50Ω
90
13-PDB-010-12-A
0
0
50Ω
105
13-PDB-020-12-B
Insertion Loss (dB)
Insertion Loss (dB)
105
15
.25 x .36 (6.4 x 9.11)
.25 x .36 (6.4 x 9.12)
1
3
Filter
2
4
50Ω
Level
Meter
50Ω
30
M8
.25 x .36 (6.4 x 9.10)
Normal Mode
1
3
Filter
2
4
45
.25 x .38 (6.4 x 9.7)
.25 x .39 (6.4 x 9.9)
2.4 (61)
7.5 (190) 8.6 (220) 1.4 (35) 3.9 (100)
60
.25 x .38 (6.4 x 9.6)
2.2
(56)
3.3
(86)
2.4
(62)
.25 x .37 (6.4 x 9.5)
.25 x .38 (6.4 x 9.8)
M4
Common Mode
1
2.9
(74)
.25 x .37 (6.4 x 9.4)
0
0
0.01
0.02
.1
1
10
20
30
60
Frequency (MHz)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF89
Commercial-Off-The-Shelf
(COTS) Filters
API Technologies’ Spectrum Control brand now offers
COTS single line feed-through EMI filters that are the
commercial equivalent to M15733-PRF/72, M15733PRF/73 and M15733-PRF/74. These reliable AC and
DC high performance filters provide an excellent source
of filtering in a compact package and are well suited for
the military and aerospace industries. They filter up to
500 A with an attenuation of 40 to 90 dB from 1 MHZ
to 1 GHz and voltage rating of 130 VDC to 250 VAC.
Please reference API mechanical drawing.
Dimensions
F
B
E
WORKORDER NO.
C
D
DATE CODE
SINGLE "D"
MOUNTING FLAT
.025 (.64) SHOULDER
A
MIL part
M15733/
Part
Number
A
±0.100
B
±0.032
C
±0.010
D
±0.010
E
±0.100
F
Max
Mounting
Flat ±0.015
72-0034
72-0046
72-0043
72-0049
72-0053
73-0034
73-0043
73-0046
73-0049
73-0051
73-0053
74-0030
74-0036
74-0042
74-0045
5004-7053-100-A
5004-7053-100-A
5004-7053-100-A
5004-7059-100-A
5004-7065-100-A
5004-7058-125-A
5004-7058-125-A
5004-7052-125-A
5004-7058-125-A
5004-7059-250-A
5004-7064-125-A
5004-7041-250-A
5004-7047-250-A
5004-7053-250-A
5004-7059-250-A
6.750
6.750
6.750
7.250
8.781
7.250
7.250
6.750
7.250
7.250
8.781
4.750
6.500
6.750
7.250
0.375
0.375
0.375
0.375
0.531
0.375
0.375
0.375
0.375
0.375
0.531
0.310
0.310
0.375
0.375
0.930
0.930
0.930
0.930
1.625
0.930
0.930
0.930
0.930
0.930
1.625
0.616
0.616
0.930
0.930
1.500
1.500
1.500
2.000
2.250
2.000
2.000
1.500
2.000
2.000
2.250
1.000
1.000
1.500
2.000
0.750
0.750
0.750
0.750
1.000
0.750
0.750
0.750
0.750
0.750
1.000
0.600
0.750
0.750
0.750
4.875
4.875
4.875
5.375
6.250
5.375
5.375
4.875
5.375
5.375
6.250
3.400
4.750
4.875
5.375
0.656
0.656
0.656
0.656
1.046
0.656
0.656
0.656
0.656
0.656
1.046
0.437
0.473
0.656
0.656
Shielded Filters
API has developed a new MRI filter product line which provides MRI/RF shielding solutions for medical, commercial
and government applications. Offers 100 dB insertion loss per MIL-STD 220 from 14 KHz to 10 GHZ.
Shielded Room Filters
P/N Series
52-1490
Configuration*
Description
1x5
1 x 30
1 x 100
1 x 150
1 x 200
1 x 225
2 x 0.5
2 x 1 ALRM
2x5
2 x 20
2 x 30
2 x 50
2 x 60
1 x 5 A, 277 VAC
1 x 30 A, 277 VAC
1 x 100 A, 277 VAC
1 x 150 A, 277 VAC
1 x 200 A, 277 VAC
1 x 225 A, 277 VAC
Speaker Filter
Fire Alarm Filter
2 x 5 A, 277 VAC
2 x 20 A, 277 VAC
2 x 30 A, 277 VAC
2 x 50 A, 277 VAC
2 x 60 A, 277 VAC
* Add to P/N series (eg. 52-1490-1x5)
Options are available with or without discharge light “L” at the end of the
part (52-1490-1x5L). Custom configurations are available. Consult factory.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF90
Military/Aerospace
Multisection Filters
API Technologies’ Spectrum Control brand will
address virtually any requirement for a military/custom
power product. Our engineering expertise and vertical
integrations reduce your speed to market as well as saves
you money. Our electromagnetic compatibility expertise in
the tempest arena can help you meet MIL-F-15733 and
MIL-STD 461 standard requirements.
Features
Applications
■
Military
■
Commercial and military/aerospace
■
High common and differential mode attenuation
■
Standard designs up to 400 Amps
Secured communications
■
■
Excellent insertion loss characteristics up to 10 GHz
Switching power supplies
■
■
Voltage rating 115-250VAC and 400VDC up to 400 Hz
Data processing equipment
■
■
Available to meet TEMPEST and FCC requirements
Ruggedized computers
■
■
Custom designs for application-specific requirements
Radar
■
■
Electronic warfare
■
Ground/air weapon systems
■
Satellites
■
Ship board systems
■
Land based vehicles
■
Fixed and mobile control stations
Test Specifications
The high performance power line filters shown on pages
59 and 60 are designed to meet the following criteria.
The information shown can be used as a basis for
filter specifications. (Contact factory for additional details).
Test
Group
IIA
IIB
III
Order
of
Test
Examination
or Test
Test Method
(Per MIL-STD-202)
Post Test
Requirements
1
Voltage Drop
Paragraph 4.6.8 of MIL-F-15733
Three percent of rated voltage max.
2
Leakage Current
UL 1283
Per applicable specification
3
Temperature Rise
MIL-F-15733 Paragraph 4.6.4
25°C max.
4
Terminal Strength
Method 211, Condition A
No evidence of loosening or rupture.
5 lb. applied force. Line Cords: 35 Lbs.
1
Shock, Medium Impact
Method 213, Condition G
Must pass DWV and Insertion Loss
2
Vibration, High Frequency
Method 204, Condition A
Monitor for shorts or open
3
Thermal Shock
Method 107, Test Condition A
Pass 90% DWV IR to be 30% of initial
4
Humidity
Method 107, Condition B, except
temperature equals 25°C
Pass 90% DWV IR to be 30% of initial
1
Life
Method 108, Condition D 1.2 x Rated AC voltage
at max. operating temp. or 1.4 x DC voltage
Pass 90% DWV insulation resistance
to be 30% of initial.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF91
Military/Aerospace
Multisection Filters
Insertion Loss
52-600-001
Insertion Loss (dB)
80
differential
mode
60
Circuit Schematic
40
common mode
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
100
1000
LINE
LOAD
52-600-002
Insertion Loss (dB)
80
60
common mode
40
20
0
0.01
differential mode
0.1
1
10
Frequency (MHz)
Dimensions
1.250
(31.75)
.250 Fast-on tabs (3 PL.)
.240
(6.10)
SWITCH
52-600-001
52-600-002
.215
(5.46)
FUSE
CONNECTOR
.250
(6.35)
2.500
(63.50)
.625
(15.8)
1.68
(42.67)
2.98
(75.70)
#6-32 THREADED
INSERTS (4 PL.)
(3.50-32)
Model
Temperature
Rating
DCR.
max.
(ohms)
Leakage
Current
(max.)
Mode
(max.)
52-600-001
5A
120/240VAC
-40°C to +65°C
.20
1 mA
60 Hz
120/240VAC
60 Hz
2.120 ± .010
(53.85)
Dimensions in inches (mm)
Voltage
Rating
10A
.03 R.
4 PL
2.500
(63.50)
CHASSIS
MOUNTING
HOLE
3.88
(98.55)
Current
Rating
52-600-002
1.250
(31.75)
-40°C to +65°C
.10
1 mA
Minimum Insertion Loss
(db) Per MIL-STD-220
50K 150K 300K 1M
10M 100M 1G
COMM
33
65
80
80
80
80
60
DIFF
37
65
80
80
80
–
–
COMM
–
50
70
80
80
70
60
DIFF
25
50
75
80
80
–
–
Consult factory for UL/CSA approval availability.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF92
Military/Aerospace
Multisection Filters
Circuit Schematic
Insertion Loss
52-523-002
52-523-002
LINE
Insertion Loss (dB)
80
LOAD
60
40
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Dimensions
52-523-002
.750
(19.05)
.600
(15.24)
2.010
(51.05)
.250
(6.35)
.250
(6.35)
3.000
(76.2)
.375
(9.52)
FUSEHOLDER
1.75
.875 (44.4)
(22.2)
3.50
.875 (88.9)
(22.2)
PLUG
#6-32 THDED
INSERT 4 PLCS.
(3.50-32)
4.00
(101.6)
.625
(15.8)
1.25
(31.75)
Dimensions in inches (mm)
Model
Current
Rating
Voltage
Rating
Temperature
Rating
DCR
max.
(ohms)
Leakage
Current
(max.)
Mode
(max.)
52-523-002
5A
120/240VAC
-40°C to +65°C
.25
1 mA
COMM
–
55
60
80
80
70
60
DIFF
–
50
60
80
80
–
–
60 Hz
Minimum Insertion Loss
(db) Per MIL-STD-220
50K 150K 300K 1M
10M 100M 1G
Consult factory for UL/CSA approval availability.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF93
Military/Aerospace
Multisection Filters
Insertion Loss
1212-0502
Insertion Loss (dB)
80
Circuit Schematic
60
1212-0502
40
20
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Dimensions
.055 TYP.
(1.40)
1212-0502
.219 TYP.
(5.56)
.656
(16.41)
.418
(10.62)
1.000
(25.4)
.500
(12.7)
.209
(5.31)
.120 TYP.
(3.05)
.594
± .031
± (.78)
1.187 ± .015
(30.15 ± .38)
1.125
(28.58)
.125 6-PLCS.
(3.18 ± .00)
.875
(22.23)
1.250
(31.75)
.105 TYP.
(2.67)
.281 ± .031
(7.14 ± .78)
MOUNTING
SURFACE
.032
(.81)
.710
(18.03)
.187
(4.75)
1.437 ± .031
(36.50 ± .78)
Model
Current
Rating
1212-0502
10A
Voltage
Rating
350VDC
Dimensions in inches (mm)
Temperature
Rating
-55°C to +125°C
DCR
max.
(ohms)
Leakage
Current
(max.)
Cx
Value
.01
1 mA
5000pF
Minimum Insertion Loss
(db) Per MIL-STD-220
10M
100M
500M
1G
20
65
70
70
240VAC 60 Hz
Consult factory for UL/CSA approval availability.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF94
Military/Aerospace
Multisection Filters
Secure Communications
API's electromagnetic compatibility expertise in
the secure communication or “TEMPEST” arena is
represented by this group of high performance filters.
These units are especially well suited for use in MILSTD-461 applications to reduce conducted emissions.
The filters are manufactured with glass sealed
terminals and connectors.
Filter Schematic A
LINE
Features
■
■
■
■
Excellent insertion loss profile
Available for DC & AC applications up to 400 Hz
Available for 3-14 Amp applications
Custom systems can be designed
to your specific needs
LOAD
A
A
C
C
B
B
Filter Schematic B
LINE
LOAD
A
A
C
C
B
B
Dimensions
2.50
(63.50)
1.25
(31.75)
Insertion Loss
1.75
(44.45)
52-378-002, -004 MIL-STD-220
52-378-002
Insertion Loss (dB)
80
1.500
(38.10)
.750
2.50
(19.05)
(63.50)
#8-32 UNC THD. INSERTS
(4.17-32)
.350 DEEP, 2 PLACES
(8.89)
CONNECTOR #8001-14S-7P-A3
MATES WITH MS-3106-14S-7S
60
40
20
0
0.01
0.1
1
10
Frequency (MHz)
Dimensions in inches (mm)
100
1000
Minimum Insertion Loss (db)
Model
Current
Rating
Voltage
Rating
Temperature
Range
DCR
max.
(ohms)
Leakage
Current
(max.)
Schematic
52-378-001
3 Amps
240VAC 60 Hz
Line to Line
-55°C to 85°C
.3
50 mA
A
30
60
70
80
80
70
70
52-378-002
5 Amps
240VAC 60 Hz
Line to Line
-55°C to 85°C
.2
50 mA
B
24
64
70
80
80
70
70
52-378-004
5 Amps
240VAC 60 Hz
Line to Line
-55°C to 85°C
.2
50 mA
A
34
64
70
80
80
70
70
52-378-005
3 Amps
240VAC 60 Hz
Line to Line
-55°C to 85°C
.3
50 mA
B
40
70
80
80
80
70
60
50 150 300
1
10 100
1
KHz KHz KHz MHz MHZ MHZ GHz
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF95
Military/Aerospace
Multisection Filters
Filter Schematic C
Insertion Loss
LINE
52-387-010, -003 MIL-STD-220
52-409-001 MIL-STD-220
Insertion Loss (dB)
80
60
52-387-010,
-003 MIL-STD-220
40
0
0.01
0.1
1
10
Frequency (MHz)
A
A
C
C
B
B
Filter Schematic D
52-409-001
MIL-STD-220
20
LOAD
LINE
100
LOAD
A
A
C
C
B
B
1000
Filter Schematic E
LINE
3 Phase and 400 Hz models available.
Please consult the factory.
LOAD
A
A
C
C
B
B
Dimensions
Figure 1
2.50
(63.50)
1.25
(31.75)
2.50
(63.50)
1.25
(31.75)
1.25
(31.75)
1.500
(38.10)
.750
2.50
(19.05)
(63.50)
#8-32 UNC THD. INSERTS
(4.17-32)
.350 DEEP, 2 PLACES
(8.89)
Current
Rating
Figure 2
3.00
(76.20)
#8-32 UNC THD. INSERTS
(4.17-32)
.350 DEEP, 2 PLACES
(8.89)
Dimensions in inches (mm)
Voltage
Rating
Fig.
52-387-010
1
10 Amps 240VAC 60 Hz
Line to Line
52-387-012
1
5 Amps
52-409-001
2
14 Amps 240VAC 60 Hz
Line to Line
Temperature
Range
DCR Leakage
max. Current
(ohms) (max.)
CONNECTOR #8001-14S-7P-A3
MATES WITH MS-3106-14S-7S
Dimensions in inches (mm)
Minimum Insertion Loss (db)
50 150 300 1.0
10 100
1
KHz KHz KHz MHz MHz MHz GHz
Sch.
Mode
common
24
60
70
80
80
70
70
common
34
64
70
80
80
70
70
differential
30
30
70
80
80
–
–
common
14
30
45
80
80
70
60
-55°C to 85°C
.2
50 mA
C
240VAC 400 Hz
-55°C to 85°C
Line to Line
.2
5 mA
D
.04
50 mA
E
-55°C to 85°C
1.75
(44.45)
#8-32 UNC
(4.17-32)
STUD
1.500
(38.10)
.750
2.50
(19.05)
(63.50)
CONNECTOR #8001-10SL-3PN-FP-A3
MATES WITH MS-3106-10SL-3S
Model
.625
(15.87)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF96
Military/Aerospace
Multisection Filters
Secure Communications
Features
■
■
■
■
■
■
Meets applicable sections of MIL-F-15733
Excellent performance
Integral IEC connector
Available with integral fused IEC connector
and two pole switch
Current ratings to 15 Amps
Custom designs available
Part Numbering System:
760 - A
06
Q
Model
Current Rating:
3, 6, 10, 15 Amps
Electrical Specifications
Rated current ranges ..................
Rated voltage.............................
Operating frequency...................
Maximum leakage current
@115VAC 60 Hz............
@250VAC 50 Hz............
Test voltage
Line-to-Line ....................
Line-to-Ground...............
3, 6, 10, 15 Amps
115-250VAC
50-60 Hz
Terminal Style:
A=.25 Quick Connect
C=Wire Leads (4" min.)
1.2 mA
2.5 mA
Series: 760; 761 or 762
1450VDC
2250VDC
Insertion Loss
760, 761, 762 - 3, 6 Amps
760, 761, 762 - 10, 15 Amps
common mode
80
60
Insertion Loss (dB)
Insertion Loss (dB)
80
40
20
differential mode
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
common mode
60
40
20
differential mode
0
0.01
0.1
1
10
Frequency (MHz)
100
1000
Common Mode (CM) is tested in a 50 ohm system with all lines tied together on the line and load sides of the filter.
Differential Mode (DM) is tested in a 50 ohm system using a 180° phase splitter on both sides of the filter.
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF97
Military/Aerospace
Multisection Filters
Dimensions - 760 Series
.55 (13.97)
Current
Rating
(Amps)
Series
B
C
3, 6
2.25
(57.15)
3.00
(76.20)
1.88
(47.75)
10, 15
5.50
(139.70)
3.15
(88.01)
2.10
(53.34)
A
760
1.23
(31.24)
Filter Dimensions
A
.13 (3.30)
B
1.332
(33.83)
.67 (42.41)
1.312
(33.32)
.95 (24.13)
C
.66 (16.67)
TERMINATION
STYLE “A”
8-32 Inserts (4 Places)
TERMINATION
STYLE “C”
Dimensions in inches (mm)
Dimensions - 761, 762 Series
C
Series
Current
Rating
(Amps)
761, 762
Filter Dimensions
A
B
C
3, 6
2.55
(64.77)
2.97
(75.43)
1.88
(47.75)
761
10, 15
5.50
(139.70)
3.15
(88.01)
2.10
(53.34)
762
10, 15
5.75
(146.05)
3.15
(88.01)
2.10
(53.34)
3.00
(76.2)
0.20
(5.08)
1.30
(33.02)
1.30
(33.02)
0.20 (5.08)
A
0.80
(20.32)
1.875
(47.62)
6-32 UNC-2B
(6 Places)
0.80
(20.32)
B
3.67
(93.21)
.40 (10.16)
Switch Omitted
in Model 761
3, 6, 10, AMP
FRONT PANEL
Switch Omitted
in Model 761
15 AMP
FRONT PANEL
.55 (13.97)
Dimensions in inches (mm)
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF98
EMI Power
Filter Solutions
Military and Aerospace
API Technologies has a long history of partnering
with leading suppliers of the defense industry.
Our ability to find solutions to suppress or eliminate
electromagnetic interference (EMI) allows us to
provide the high reliability filters required for military
and aerospace applications. API’s Spectrum Control
brand can design your custom filter with a unique
mechanical package for those unusual or tight fitting
spaces, higher performance filtering and the voltage
rating you need to address all of your AC and DC
power issues.
Communications
API’s Spectrum line of power filter solutions can
create an agency-approved product that will filter
and condition the power to your communications
infrastructure equipment, as well as eliminate emissions
that can contaminate your distributed AC and DC
power. Our custom power filters will incorporate all
the components and the filtering in one complete
package to save you space, time and money. And as
a vertically integrated supplier, API offers global low
cost manufacturing which allows us to produce fast
prototypes and a quicker time to market.
Medical
Our many years of experience in providing EMI/RFI
solutions has given us the know-how to design products
to meet the specific constraints and requirements of the
medical industry. Much of the medical equipment used
today requires complete suppression of any and all
EMI, as well as low-leakage, nonmagnetic properties
to prevent negatively affecting surrounding equipment.
We will design and build a high reliability, high
performance custom power filter to meet your
system and all EN requirements.
Industrial
At API, we do everything from package design
and metalworking to EMI filtering to EMC testing,
which means a lower cost for you. Our engineers
will design and build a custom power filter that will
satisfy global EMC regulations, improve speedto-market times, overcome space constraints and
withstand harsh environmental conditions. Our
plug-and-play designs cover a range of industrial
and instrumentation applications that will address
any of your power filtering needs with current ratings
as high as 500 Amps.
■ Unique mechanical
packages addressing
specific size and
space constraints
■ Customized and fully
integrated assemblies
incorporating filters,
circuit components
and connectors
■ Custom applicationspecific filters that
meet MIL standard
environmental conditions
■ Complex, multifunctional
designs that incorporate
the filtering and custom
circuitry into one easy
to install package
■ Designs with selective
line filtering, high voltages
and agency approvals
■ High reliability filters
with low-leakage and
nonmagnetic options
meet EN testing requirements
■ Vertically integrated
solutions include
packaging, circular
connectors and
filter plates
■ Compact, space-saving
assembly optimized for
the welding industry
■ Ruggedized construction
and design flexibility
allow our filters to meet
demanding environmental
and performance
requirements
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF99
55DC Link Series
Power Film Capacitors
API’s Spectrum Control line of high reliability DC link
capacitors are ideal for power inverter applications which
require superior life under harsh operating conditions,
such as electric vehicle power conversions, battery
chargers, aircraft power conversion systems and radar
systems. Featuring a compact and cost-effective design,
DC link capacitors are manufactured from segmented,
self-healing metallized polypropylene, resulting in longer
life expectancy (+100,000 hrs). With high capacitance density
and ripple current capabilities, API’s DC link capacitors
are the ideal replacement for electrolytic capacitors.
Dimensions
M Configuration
ø20.8 MM
(2 PLCS)
Specifications
■
Capacitance tolerance: +/- 10% standard
■
Rated voltage: 900 to 1300 VDC
■
Test voltage between terminals and housing: 5kVDC for 10 sec
Series
–
M6 x 1.0 THREAD
10 MM DEEP MIN.
(2 PLCS)
ø20.8 MM
(2 PLCS)
32 or 45 MM
–
Voltage
901 = 900 VDC
321
H
–
Capacitance
– = Segmented
321 = 320 µF
112 = 1100 VDC S = Standard
441 = 440 µF
(non-segmented)
132 = 1300 VDC
±2.00MM
XX
Terminal Code
– = M12 stud
M = M8 External Thread,
N = No M12 stud 45mm center-center
F = M5 Internal Thread,
45mm center-center
S = M6 Internal Thread,
45mm center-center
55DC-901-321-XX
55DC-901-441-XX
55DC-901-561-XX
55DC-901-681-XX
55DC-112-221-XX
55DC-112-281-XX
55DC-112-361-XX
55DC-112-421-XX
55DC-132-161-XX
55DC-132-211-XX
55DC-132-251-XX
55DC-132-321-XX
MM
90 +2
-0 MM
6 ±1 MM
(2 PLCS)
901
Part
Number
16 ±1MM
S Configuration
55DC Link Series Part Numbering System
55DC
±2.00MM
16 ±1MM
Enclosure/construction: aluminum housing,
brass terminals with dry resin, UL 94V-0 encapsulant
RoHS compliant
6 ±1 MM
(2 PLCS)
M12 x 1.75 THREAD
M12 x 1.75 THREAD
■
Low ESR and ESL
32 or 45 MM
6 ±1 MM
(2 PLCS)
H
Test voltage between terminals: 150% rated voltage for 10 sec
■
ø20.8 MM
(2 PLCS)
H ±2.00 MM
Operating temperature range: -55°C to +85°C standard
(+105°C upon special request)
■
MM
90 +2
-0 MM
20 ±1 MM
■
■
M5 x 0.8 THREAD
5 MM DEEP MIN.
(2 PLCS)
32 or 45 MM
M8 x 1.25 THREAD
(2 PLCS)
Capacitance range: 160 µF to 680 µF standard
(others available upon request)
■
F Configuration
MM
90 +2
-0 MM
M12 x 1.75 THREAD
16 ±1MM
MA = M8 External Thread,
32mm center-center
FA = M5 Internal Thread,
32mm center-center
SA = M6 Internal Thread,
32 mm center-center
Rated Voltage
(VDC)
Capacitance
(µF)
D Diameter
(mm)
Height H
(mm)
Typ ESR
(mOhms)
Typ ESL
(nH)
Irms Max.
(A) M
Weight
(kg)
900
900
900
900
1100
1100
1100
1100
1300
1300
1300
1300
320
440
560
680
220
280
360
420
160
210
250
320
90
90
90
90
90
90
90
90
90
90
90
90
97
120
145
170
97
120
145
170
97
120
145
170
2.1
1.8
2.1
2.5
2.5
2.1
1.9
2.3
2.1
1.9
2.5
2.8
50
60
60
80
50
50
60
80
50
50
60
80
60
60
60
60
60
60
60
60
60
60
50
53
0.80
1.00
1.10
1.30
0.90
1.20
1.30
1.30
0.80
1.00
1.20
1.30
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF101
Audio
Film Capacitors
Features
■
Multiple dielectric options
■
Metalized film and film/foil construction
■
Wrap and fill, encapsulated and hermetic options
■
Multiple lead configurations, tape and epoxy colors
■
Ability to wind 2-10 layers in a single pass
■
Ability to provide 4-12 micron film
■
Wide range of sized up to 2.000" D x 4.250" L
■
Custom designs available
Benefits
■
■
Application matching for best performance and cost
Consistent and repeatable, producing high quality
components in smaller package size
■
Improved productivity and increased voltage capability
■
Excellent performance especially for audio applications
■
■
Tighter tolerance to help meet critical application
requirement for capacitance and voltage
Hermetic option provides enhanced protection for
use in harsh environments
Capacitor
Type
Operating
Temperature
WVD
C
WVAC
Capacitance
Range
DF
Metallized Film
Polyester
-55 to +85°C
50 - 600
N/A
0.001 - 15 µF
1.0%
Film - Foil
Polyester
-55 to +85°C
100 - 600
N/A
0.001 - 5 µF
0.5%
Metallized
Polypropylene
-55 to +85°C
200 - 600
504 @ 60 Hz
115 @ 1 kHz 0.001 - 8 µF
0.2%
Film-Foil
Polypropylene
-55 to +85°C
100 - 600
AC Capable
TC
DA
Key
Features
-6 to +15%
0.6%
Low cost
-6 to +15%
0.6%
Low cost
-4 to +2%
0.1%
Low DF
0.1%
-4 to +2%
0.1%
Low DF
Metallized
Polyphenylene
Sulfide
-55 to +125°C
50 - 600
25 - 50 kMΩ • µF
240 @ 60 Hz 0.001 - 10 µF 0.3 - 0.5% or 50 - 100 kMΩ,
160 @ 1 kHz
w/e less
±2%
0.2%
Metallized
Polycarbonate*
-55 to +125°C
50 - 600
25 - 50 kMΩ • µF
240 @ 60 Hz 0.001 - 10 µF 0.3 - 0.5% or 50 - 100 kMΩ,
160 @ 1 kHz
w/e less
±2%
0.2%
Metallized
Teflon
-55 to +170°C
50 - 5000
AC Capable
-6 to +15%
0.06%
0.001 - 1 µF
0.0047 10 µF
0.1%
Insulation
Resistance
10 - 25 kMΩ • µF
or 40 - 60 kMΩ,
w/e less
50 kMΩ • µF
or 100 kMΩ,
w/e less
200 kMΩ • µF
or 400 kMΩ,
w/e less
250 kMΩ • µF
or 500 kMΩ,
w/e less
100 kMΩ • µF
or 200 kMΩ,
w/e less
High temp
capability
No voltage
derating
High temp
capability
No voltage
derating
High temp
capability
Electrical
characteristics
* Metalized Polycarbonate is being phased out and replace by Metalized Polyphenylene Sulfide
API TECHNOLOGIES • 8061 Avonia Rd. • Fairview, PA 16415 • Ph: 814-474-1571 • Fax: 814-474-3110 • eis.apitech.com
API TECHNOLOGIES’ SPECTRUM CONTROL GmbH • Hansastrasse 6 • 91126 Schwabach, Germany • Phone: (49)-9122-795-0 • Fax: (49)-9122-795-58
PF102