Technical Data

Hygienic diaphragm pressure gauge, NG 100
Application
For gaseous and liquid, non-aggressive and aggressive media and aggressive environments. The male clamp connection is especially suitable for use in processes meeting hygienic requirements.
The pressure gauge is constructed such that, in case of diaphragm breakage, contamination of the medium is not possible (no transmitting liquid) due to the dry measuring cell (for DP version).
Pressure ranges
6 bar and 10 bar
Range of application
For static pressure 100%, for dynamic pressure 90% of full scale
Overpressure safety
1.3 x full scale value
Accuracy
Cl. 1.6 acc. EN 837-3
Execution
EN 837-3
Dial
White, black scale acc. EN 837-3
Pointer
Aluminium, black, EN 837-3
Window
Multilaminated safety glass
Case
Bayonet lock version, stainless steel, 1.4301 with pressure blow out
Temperarute ranges
Temperature of media max +150°C
Ambient temperature min - 20°C/max +60°C
Temperature behaviour
For a deviation from the reference temperature of +20°C
Measuring system: max ±0.8%/10k of measuring range
Protection
IP 54 acc. EN 60529 / IEC 529
Selection Chart
Ordering code
DPx 100 / xxx.xxx
/ xxx
Indication range
System design
Standard
DP
Nominal size
NG 100
100
Case
Stainless steel 1.4301, bright drawn
2
Structural shape
Direct mounting
1
3 1
(E) 3
Process connection (material)
Stainless steel 1.4435 (316L)
Scale
Standard
Measuring element
Stainless steel 1.4435 (316L)
Process connection (structural shape)
Clamp connection ISO 2852
Clamp connection ISO 2852
Clamp connection ISO 2852
Varivent connection ® Type N,
Varivent connection ® Type F,
Paper connection with tubes DN 2» DN 1 1/2»
DN 3» DN 40/125
DN 25/32
ø48 Special versions and auxiliary units (on request)
Wetted area polished
other connections
www.baumer.com
Design and specification subject to change without notice.
Order DN
number bar
065
0 … 6 075
0 … 10 535
545
- 1 … 5
- 1 … 9
Measuring
element
E
E
E
E
A
B
C
D
E
P
spez
on request
Data sheet A 23 D1.307
Page 1
Dimensions
shown: Clamp connection
Paper connection with tubes Varivent connection ®
49
101
1.4435
101
1.4435
1.4435
h
h
h
ca.16
101
øDM
øD
UK/2009-10-01 This data sheet may only be reproduced in full.
øDM
17
øD
øD1
øD
Size table
NG
process connection
D
DM
D1
h
100 Clamp DN 2»
64
48
-
86
100 Clamp DN 1 1/2» 50,5 35 -
86
100 Clamp DN 3»
91 35/48 -
86
100 Varivent DN 40/125 84 48/35 64
135±2 100 Varivent DN 25/32 66 35 46
135±2 100 Paper con. Tubes 48 35 -
106±2 www.baumer.com
Design and specification subject to change without notice.
Weight, approx. kg
for
System design DP
approx. 2,0
approx. 1,9
approx. 2,0
approx. 2,2
approx. 2,1
approx. 2,1
Data sheet A 23 D1.307
Page 2