EW 502

Hybrid Hall Effect ICs EW-series
EW-502
Shipped in bulk(500pcs/Bag)
EW-502 is composed of a Ultra-high sensitive InSb Hall element and a signal processing IC chip in a package.
Bipolar Hall
Supply Voltage
Effect Latch
4.5∼18V
Hall Element
Continuous
Excitation
Low Sensitivity
Bop:10mT
Output
With pull-up
Resistor
SIP
Notice:It is requested to read and accept "IMPORTANT NOTICE" written on the back of the front cover of this catalogue.
●Operational Characteristics
Vout
S
Vcc
H
Vd
Marking
1
2
1:Vcc
2:GND
3:OUT
3
Bh
Vsat
Brp
N-pole
N
L
0
Bop
S-pole
Magnetic flux density
●Absolute Maximum Ratings(Ta=25℃)
Item
Symbol
Limit
●Functional Block Diagram
1:Vcc
Unit
RL
Supply Voltage Vcc
18
V
Output H Voltage Vo(off)
Vcc
V
Output L Current Isink
15
mA
Operating Temperature Range Topr
−20 ∼ 115
℃
Storage Temperature Range Tstg
−40 ∼ 125
℃
(*)
Reg.
2:GND
Voltage Regulator
Hall Element
●Magnetic and Electrical Characteristics(Ta=25℃)
Symbol
Conditions
Supply Voltage VCC
3:OUT
Amp.
(*)Please refer to Supply Voltage Derating Curve.
Item
Internal Pullup
Resistor
Min.
4.5
Typ. Max. Unit
12
18
V
Operating Point BOP
Vcc=12V
5
20
mT
Release Point
Brp
Vcc=12V
-20
-5
mT
Hysteresis
Bh
Vcc=12V
10
Output Down Voltage
Vd
Vcc=12V,OUT''H''
20
mV
Output Saturation Voltage Vsat
Vcc=12V,OUT''L''
0.4
V
Supply Current
Icc
Vcc=12V,OUT''H''
8
mA
Internal Load Resistance
RL
13
KΩ
7
mT
1[mT]=10[Gauss]
Amplifer
Output Stage
Schmitt Trigger
EW-502
•Please be aware that our products are not intended for use in life support equipment, devices, or systems. Use of our products in such applications requires the
advance written approval of our sales staff.
Certain applications using semiconductor devices may involve potential risks of personal injury, property damage, or loss of life. In order to minimize these risks,
adequate design and operating safeguards should be provided by the customer to minimize inherent or procedural hazards. Inclusion of our products in such
applications is understood to be fully at the risk of the customer using our devices or systems.
●Package(Unit:mm)
●Supply Voltage
16
Supply Voltage[V]
0.1
1.0
1.6
0.45
18
φ2.0
0.60
+0.2
4.0 −0.1
0.7
20
S-pole
0.7
5°
Sensor Center
2.25
0.45
1.0
0.6
Max. 12.5
0.6
1.0
c
1.5±0.2
4.5±0.1
14
d
12
10
8
6
4
2
0
–40
–20
0
1 2 3
0.4
1.27
5°
1.27
Marking
20
40
60
80
Ambient Temperature[℃]
100
120
0.3
1:Vcc
1
2 3
2°
2:GND
3:OUT
Note) The sensor center is located
within the φ0.3mm circle.
●Temparature Dependence of Bop. Brp
●Supply Voltage Dependence of Bop. Brp
15
Bop
10
5
Vcc=12V
0
−5
−10
−15
−40
Operating Point[mT]
Operating Point[mT]
15
Ta = 25℃
0
−5
−15
0
20
40
60
l
5
−10
Brp
−20
Bop
10
80
Ambient Temperature[℃]
100
120
140
Brp
0
5
10
Vcc[V]
15
20
p
q
IMPORTANT NOTICE
 These products and their specifications are subject to change without notice.
When you consider any use or application of these products, please make
inquiries the sales office of Asahi Kasei Microdevices Corporation (AKM) or
authorized distributors as to current status of the products.
 Descriptions of external circuits, application circuits, software and other related
information contained in this document are provided only to illustrate the
operation and application examples of the semiconductor products. You are
fully responsible for the incorporation of these external circuits, application
circuits, software and other related information in the design of your
equipments. AKM assumes no responsibility for any losses incurred by you or
third parties arising from the use of these information herein. AKM assumes no
liability for infringement of any patent, intellectual property, or other rights in
the application or use of such information contained herein.
 Any export of these products, or devices or systems containing them, may
require an export license or other official approval under the law and
regulations of the country of export pertaining to customs and tariffs, currency
exchange, or strategic materials.
 AKM products are neither intended nor authorized for use as critical
componentsNote1) in any safety, life support, or other hazard related device or
systemNote2), and AKM assumes no responsibility for such use, except for the
use approved with the express written consent by Representative Director of
AKM. As used here:
Note1) A critical component is one whose failure to function or perform
may reasonably be expected to result, whether directly or indirectly, in the
loss of the safety or effectiveness of the device or system containing it,
and which must therefore meet very high standards of performance and
reliability.
Note2) A hazard related device or system is one designed or intended for
life support or maintenance of safety or for applications in medicine,
aerospace, nuclear energy, or other fields, in which its failure to function
or perform may reasonably be expected to result in loss of life or in
significant injury or damage to person or property.
 It is the responsibility of the buyer or distributor of AKM products, who
distributes, disposes of, or otherwise places the product with a third party, to
notify such third party in advance of the above content and conditions, and
the buyer or distributor agrees to assume any and all responsibility and
liability for and hold AKM harmless from any and all claims arising from the
use of said product in the absence of such notification.
June 2, 2010