View Electronic Protection Fuse Selection Guide

FUSE SELECTION GUIDE
A quick reference guide to selecting fuses for electronic applications
Max.
Voltage
< 250VAC/VDC
Mounting
Surface Mount Fuses
Fuse Type
NANO 2® Fuse
Through-Hole
Thin Film Fuse
Ceramic Chip Fuse
–55°C to 90°C
PICO® SMF Fuse
PICO® Fuse
TE
MICRO™
Fuse
Hazardous Area
Fuse
–55°C to
150°C
Footprint
1206
2410
Fuse/FH Assy. (2410)
4012
0402
0603
1206
1206
0603
1206
1206
7.24 × 4.32 × 3.05 mm
Body
Material
Ceramic
Ceramic
Ceramic/
Thermoplastic/Metal
Ceramic
FR4
FR4
FR4
FR4
Ceramic
Ceramic
Ceramic
Thermoplastic
Current
Rating
1A to 10A
62 mA to 20A
depending on series
62 mA to 10A
20A to 40A
250 mA
to 5A
250 mA
to 5A
7A
10A to 20A
62 mA to 5A
depending on series
62 mA to 30A
depending on
series
50 mA to 6.3A
2 mA to 5A
0.062A to 5A
50A @
125VAC/VDC
300A @ 32VDC
100A @ 125VAC
180A @ 72VDC
up to 500A @ 72VDC
depending on rating
35A @
32VDC
35A @
32VAC/
VDC
35A @
24VAC/
VDC
150A @
32VDC
50A @ 125VAC
50A @ 125VDC up
to 300A @ 125VDC
depending on rating
50A @ 32VAC
up to 50A @
125VAC
300A @ 32VDC
100A @
125VAC
10 kA @
125VAC/VDC
50A @ 125VAC
300A @ 63VDC
up to 300A @ 125VDC
depending on rating
Interrupt
Rating
50A @ 65VAC
50A @ 32VAC
up to 50A @ 125VAC
up to 50A @ 48VAC
50A @ 65VDC
up to 50A @ 1245VDC
50A @ 63VDC
300A @ 24VDC
up to 50A @ 75VDC
up to 100A @ 75 VDC
250 mA to 6A 250 mA to 8A
125 mA to 10A
depending on depending on
depending on series
series
series
50A @ 24VDC
35A @ 24VAC/VDC
up to 50A
up to 50A
@ 32VDC
@ 63VAC/VDC
depending on
depending on rating
rating
50A @
24VAC/VDC
up to 50A @
63VAC/VDC
depending on
rating
13 × 8mm
Ceramic body
Metal/
Thermoplastic
coated in epoxy
Thermoplastic
Polyamide
Characteristics / Agency Approvals
451/453
(125VAC/VDC)
Fast
Acting UL
395
(125VAC)
456
(125 VAC/72 VDC)
Only 20 to 30A
Fast
Acting IEC
Fast
Acting UR
458
(48 VAC/
75 VDC)
448
(125VAC/VDC)
451/453
(125VAC/VDC)
154
(125VAC/VDC)
157
(125VAC/VDC)
456
(125 VAC/72 VDC)
467
429007.L
435
(32VAC/ (24VAC/
(32VDC)
VDC)
VDC)
466
(63VAC/VDC)
438
(32VDC)
441
(32VDC)
437
(63VAC/VDC)
440
(32VAC/VDC)
501
(32VDC)
459
(125VAC/VDC)
251
(125VAC/VDC)
275
(32VAC/VDC)
272
(125VAC/VDC)
273
(125VAC/VDC)
396
(125VAC)
SLO-BLO®
Fuse UL
Time Lag IEC
SLO-BLO®
Fuse UR
Hazardous
Area
Protection
littelfuse.com
452/454
(125VAC/VDC)
449
(125VAC/VDC)
154T
(125VAC/VDC)
157T
(125VAC/VDC)
468
(63VAC/VDC)
469
(63VAC)
460
(125VAC/VDC)
471
(125VAC/VDC)
472
(125VAC/VDC)
473
(125VAC/VDC)
259
(125VAC/VDC)
259 UL 913
(125VAC/VDC)
≥ 250VAC
Max. Voltage
Mounting
Through-Hole /Fuseholder
Surface Mount Fuses
PICO
Fuse
®
Fuse Type
TR/TE
Barrier
Cartridge
Footprint
Body Material
Thermoplastic
Ceramic
3.6mm × 10mm
4.5mm × 15mm (2 AG)
Ceramic
Glass
5 × 20mm
EBF
EBF
6 × 32mm (3 AG/3 AB)
Ceramic
Glass
Ceramic
Glass
FLATPAK®
Fuse
NANO 2® Fuse
6.35 × 10.16mm 10.1 × 3.12mm
Cermic body
coated in epoxy
Thermoplastic
12.1 × 4.5mm
Ceramic
Ceramic
Ceramic
Thermoplastic
500 mA to 2 A
500mA to 5 A
60 A @ 600VAC
150 A @ 250VAC/
VDC up to 100 A
@ 350VAC/VDC
depending on
rating
Thermoplastic
Thermoplastic
500 mA to 5A
15A to 30A
250mA to 6.3 A
depending on
series
50 A @ 250VAC
100 A @ 250VAC
50 A @ 100VDC
100 A @ 250VAC
Current Rating
40 mA and up to 10 A
depending on series
50mA to 750mA
depending on series
50mA to 10 A depending
on series
100mA to 10 A depending
on series
50mA to 20 A
depending on series
32mA to 16 A depending
on series
125mA to 40 A
depending on the series
10mA to 30 A depending
on series
62mA to 5 A
2 A to 10 A
2 A to 10 A
62mA to 5 A
depending on
series
Interrupt Rating
35A @ 250VAC
up 100A @ 300VAC
depending on rating
1500A
@ 277VAC/VDC
up to 4000 A @ 250VAC/
VDC depending on rating
35 A @ 250VAC
up to 63 A @ 250VAC
depending on rating
400 A @ 125VAC
up to 100 A @ 350VAC
depending on rating
400 A @ 250VAC
up to 1500A @ 250VAC
or 200 A @ 420VAC
or 100 A @ 500VAC
depending on rating
35 A @ 250VAC
up to 200 A @ 250VAC,
10kA @ 125VAC
depending on rating
35 A @ 250VAC
up to 1000 A @250VAC
or 1000A @ 500VAC
up to 20ka @ 450VAC
or 10ka @ 1000VAC
depending on rating
300 A @ 32VAC
up to 200 A @ 250VAC
depending on rating
50 A @ 250VAC
100 A @ 350VAC
100 A @ 350VAC
50 A @ 250VAC
Ceramic
10.1 × 3.12mm
10.1 x 3.12 mm
(Telecom Nano)
10.5 × 4.5mm
Characteristics / Agency Approvals
Very Fast Acting
231 (500VAC)
Fast Acting UL
373 (250VAC)
874 (250VAC)
Fast Acting IEC
370 (250VAC)
876 (250VAC)
Fast Acting UR
808 (250VAC)
242
(250VAC/VDC)
224 (250VAC)
225 (250VAC)
235 (250VAC)
216 (250VAC)
216SP (250VAC)
Time Lag IEC
SLO-BLO® Fuse UR
312/318 (250 VAC)
217 (250VAC)
464 (250VAC)
208 (350VAC)
220 (300VAC)
263
(250VAC)
Medium Acting UL
SLO-BLO® Fuse UL
324/314 (250VAC)
202
(250VAC)
463
(250VAC/100VDC)
485 (250VAC)
201 (250VAC)
374 (250VAC)
875 (250VAC)
372 (250VAC)
382 (250VAC)
392 (250VAC)
400 (250VAC)
804 (250VAC)
369 (300VAC)
383 (300VAC)
807 (300VAC)
229 (250VAC)
230 (250VAC)
233 (125VAC)
234 (250VAC)
215 (250VAC)
215SP (250VAC)
835 (250VAC)
477 (500VAC)
877 (250VAC)
326/325 (250VAC)
313/315 (250 VAC)
218 (250VAC)
219XA high i2t
(250VAC)
203
(250VAC)
209 (350VAC)
Electronic Ballast
420VAC/VDC
447 (350VAC)
443
(250VAC)
446 (350VAC)
328
(300VAC/100VDC)
300VAC
477 (500VAC)
977 (500VAC)
505 (500VAC)
600VAC
461 (600VAC)
1000VAC
508 (1000VAC)
Audio
285 (250VAC)
242
(250VAC/VDC)
305
(277VAC/277VDC)
Hazardous Area
Protection
Max. Voltage
Mounting
DC Protection ≥ 250 VDC
Through-Hole
Fuse Type
Interrupt Rating
Surface Mount Fuses
Cartridge
5 × 20mm
Ceramic
500mA to 20A depending on series
400A @ 400VDC up to 1500A @ 400VDC or
300A @ 420VDC or 200A @ 450VDC
depending on rating
6x25mm
Ceramic
5A to 40A
5 to 40A 2500A @ 70VDC
40A 1500A @ 250VAC
TE
6 × 32mm
Ceramic
315mA to 30A depending on series
1000A @ 250VDC
up to 10kA @ 1000VDC
depending on rating
NANO 2® Fuse
Thermoplastic
1A to 5A
10.5 × 4.5mm
Thermoplastic
500mA to 5A
12.1 × 4.5mm
Ceramic
500mA To 3.15A
10ka @ 250VDC
up to 10kA @ 450VDC
150A@250 VDC
100 A@350 VDC
100A@600 VDC
littelfuse.com
688 (70 VDC)
808 (250 VDC to 450 VDC)
487 (420VDC)
NOTE:
This tool should ONLY be used as a quick reference guide to suggest a starting point in the overcurrent
selection process. After the initial parts have been selected, the designer should reference the below link titled
Fuseology. The Fuseology document includes a Step-by-Step selection process to select the correct fuse for the
application. Once a part has been selected, the designer should retrieve the actual datasheet from Littelfuse.
com. Littelfuse always recommends that application testing be conducted to verify the correct part selection.
In order to use this quick reference guide, the designer just has to know a few of the key parameters such
as Max Voltage, Rated Current, Interrupting Rating, Mounting Type, Footprint, Fast Acting or Time Lag, and
Safety Certifications.
Fuseology-Fuse Characteristics, Terms and Consideration Factors:
http://www.littelfuse.com/data/en/Product_Selection_Guides/Fuseology.pdf
Characteristics/Agency Approvals
70VDC
250VDC
420VDC
450VDC
400VDC Time Lag IEC
450VDC Time Lag IEC
500VDC
600VDC
1000VDC
462
(350VAC/VDC)
487 (420VAC/VDC)
500VAC
Footprint
Body Material
Current Rating
462
(250VAC/VDC)
465 (250VAC)
462 (250 VDC)
504 (420VDC)
808 (250 VDC to 450 VDC)
477 (400 VDC)
977 (450 VDC)
505 (500 VDC)
506 (600 VDC)
508 (1000 VDC)
485 (600 VDC)
EC118Nv0116