Gas Discharge Tubes CG5 and SL0902A Series CG5 and SL0902A Series RoHS Description Littelfuse Broadband Optimized™ SL0902A Series offers high surge ratings in a miniature package. Special design features provide high levels of protection against fast rising transients in the 100V/μs to 1kV/μs range usually caused by lightning disturbances. Low insertion loss is perfectly suited to broadband equipment applications. The capacitance does not vary with voltage, and will not cause operational problems with ADSL2+, where capacitance variation across Tip and Ring is undesirable. These devices are extremely robust and are able to divert a 2500A pulse without destruction. For AC Power Cross of long duration, overcurrent protection is recommended. Agency Approvals AGENCY AGENCY FILE NUMBER E128662 (exception: CG550) 2 Electrode GDT Graphical Symbol Littelfuse CG5 MS mini surge arresters are specifically designed for protection of electrical and communication equipment against over voltage transients in surface mount assembly applications. This series offers the most cutting edge protection using non-radioactive elements. Features Additional Information Datasheet CG5 Series Resources CG5 Series Samples CG5 Series Datasheet SL0902A Resources SL0902A Samples SL0902A •RoHS compliant and Lead-free •GHz working frequency •Excellent stability on multiple pulse duty cycle •Excellent response to fast rising transients. •Ultra Low Insertion Loss •5KA surge capability tested with 8/20μS pulse as defined by IEC 61000-4-5 •Ultra small devices offered in a variety of mounting lead forms •Non-Radioactive •Low capacitance (<1pF) •Voltage Ranges 90V to 600V •UL recognized •Conforms to ITU-T K12, IEC 1000-4-5 Applications •Communication equipment •CATV equipment •Test equipment •Data lines •Power supplies •Telecom SLIC protection •Broadband equipment •ADSL equipment, including ADSL2+ •XDSL equipment •Satellite and CATV equipment •General telecom equipment © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 11/06/15 Gas Discharge Tubes CG5 and SL0902A Series Electrical Characteristics Device Specifications (at 25°C) DC Breakdown in Volts (@100V/s) (@100V/µs) Part Number SL0902A090 CG590 MIN TYP Life Ratings Impulse Impulse Insulation CapaciBreakdown Breakdown Resistance tance in Volts In Volts (@1MHz) MAX (@1 Kv/µsec) MAX MIN 108 550 700 10 Ω (at 50V) 650 72 90 CG5145 116 145 174 550 CG5150 120 150 180 550 SL0902A230 CG5230 184 230 276 550 CG5250 200 250 300 600 CG5270 216 270 324 650 SL0902A350 CG5350 280 350 420 800 CG5400 320 400 480 900 SL0902A420 336 420 504 900 1000 CG5470 376 470 564 1000 1200 SL0902A600 CG5600 480 600 720 1350 1500 Surge Life (10/1000µs) Nominal Nominal AC Max Impulse AC Dischage Impulse Discharge Discharge Current Discharge Current Current (9 cycle @50Hz) Current (8/20µs) (10x1sec @50-60Hz) 10 shots (@5kA) 5A (1 Application @ 10/350µs) MAX 10 650 900 1010 Ω (at 100V) 1.5 pf 300 shots (@100A) 10 A Product Characteristics CG5xxxLS (Outline 500), CG5xxxxLTR & CG5350L-03TR (Outline 502), and CG5xxxL-02 (Outline 503): Device Nickel Plated 2–5 Microns Wire Tin Plated 17.5±12.5 Microns Construction Ceramic Insulator. CG5xxx (Outline 501), and CG5xxxMS & SL0902AxxxSM (Outline 505): Device Tin Plated 17.5±12.5 Microns Construction Ceramic Insulator. Materials Product Marking LF Logo, Voltage and date code Glow to arc transition current < 0.5Amps Glow Voltage 140 Volts Storage and Operational Temperature -40 to +90 Typical Insertion Loss Voltage vs. Time Characteristic @ 1.0 GHz = 0.01 dB Max dynamic breakover voltage @ 1.4GHz = 0.1 dB @ 1.8 GHz = 0.53 dB Voltage (V) @ 2.1 GHz = 0.81 dB @ 2.45 GHz= 1 dB @ 2.8 GHz = 1.2 dB Hold-over voltage @ 3.1 GHz = 1.5 dB @ 3.5 GHz = 2.1 dB On-State voltage 0 200 400 600 Time (ns) © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 11/06/15 800 1000 1200 0.5kA Gas Discharge Tubes CG5 and SL0902A Series Device Dimensions Outline 500 - CG5xxxLS Outline 503 - CG5xxxL-02 (except CG5600L-02, see Outline 502) PROFILE VIEW TOP VIEW 5.00 ± 0.20 [0.197 ± 0.008] 5.00 ± 0.20 [0.197 ± 0.008] TOP VIEW PROFILE VIEW 5.0 ± 0.2 5.30 ± 0.30 [0.209 ± 0.012] 40° ± 3° [0.197 ± 0.008] 3.0 ± 0.3 [0.118 ± 0.008] 5.30 ± 0.30 0.40 ± 0.03 [0.209 ± 0.012] [0.016 ± 0.0012] 0.004 2 Surfaces 5.0 ± 0.2 [0.197 ± 0.008] 0.80 [0.031] 0.80DIA. TYP. [0.031] 6.3 ± 0.2 [2.480 ± 0.079] 8.00 ± 0.30 [0.315 ± 0.012] 9.30 ± 0.30 [0.366 ± 0.012] Outline 505 - CG5xxxMS and SL0902AxxxSM SOLDER PAD LAYOUT PROFILE VIEW TOP VIEW 8.00 [0.315] 6.6 ± 0.2 [0.260 ± 0.008] 5.50 [0.216] 5.4 ± 0.15 [0.212 ± 0.006] 1.80 [0.071] 0.5 ± 0.1 9.80 [0.386] [0.02 ± 0.004 ] 5.0 ± 0.2 [0.197 ± 0.008] Outline 501 - CG5xxx 3.8 [0.15] 5.4 ± 0.15 [0.212 ± 0.006] SOLDER PAD LAYOUT 4.50 [0.18] TOP VIEW PROFILE VIEW 5.10 5.0 ± 0.15 [0.2] [0.197 ± 0.006] 0.70 [0.028] 5.0 ± 0.2 [0.197 ± 0.008] Outline 502 - CG5xxxLTR (also CG5350L-03TR, CG5600L-02) PROFILE VIEW 0.80 DIA. TYP. [0.024] TOP VIEW 5.0 ± 0.2 [0.197 ± 0.008] 5.0 ± 0.2 [0.197 ± 0.008] 62 ± 2 [2.441 ± 0.079] © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 11/06/15 Gas Discharge Tubes CG5 and SL0902A Series Soldering Parameters - Reflow Soldering (Surface Mount Devices) Pb – Free assembly Pre Heat - Temperature Min (Ts(min)) 150°C - Temperature Max (Ts(max)) 200°C - Time (Min to Max) (ts) 60 – 180 secs 3°C/second max TS(max) to TL - Ramp-up Rate 5°C/second max - Temperature (TL) (Liquidus) 217°C - Temperature (tL) 60 – 150 seconds 260+0/-5 °C Time within 5°C of actual peak Temperature (tp) 10 – 30 seconds Ramp-down Rate 6°C/second max Time 25°C to peak Temperature (TP) 8 minutes Max. Do not exceed 260°C tL Ramp-down Preheat TS(min) 25 Peak Temperature (TP) Critical Zone TL to TP Ramp-up TL TS(max) Average ramp up rate (Liquidus Temp (TL) to peak Reflow tP TP Temperature Reflow Condition tS time to peak temperature (t 25ºC to peak) Time Soldering Parameters - Hand Soldering Solder Iron Temperature: 350° C +/- 5°C Heating Time: 5 seconds max. Soldering Parameters - Wave Soldering (Thru-Hole Devices) Recommended Process Parameters: 280 Wave Parameter 260 Lead-Free Recommendation Preheat: 240 220 (Depends on Flux Activation Temperature) 200 180 160 140 120 100 80 60 40 Time (Seconds) Cooling Time Preheat Time Dwell Time © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 11/06/15 230 240 220 210 200 190 180 170 160 150 140 130 120 110 90 100 80 70 60 50 40 20 0 0 30 20 10 Temperature (°C) - Measured on bottom side of board 300 (Typical Industry Recommendation) Temperature Minimum: 100° C Temperature Maximum: Preheat Time: 150° C 60-180 seconds Solder Pot Temperature: 280° C Maximum Solder Dwell Time: 2-5 seconds Note: These devices are not recommended for IR or Convection Reflow process. Gas Discharge Tubes CG5 and SL0902A Series Part Numbering System and Ordering Information CG5 xxx L TR SL0902A xxx SM Series Series SL0902A CG5 Breakdown Voltage 90 = 90V 230 = 230V 350 = 350V 600 = 600V Lead Option Code (Blank) = Core Device (No Leads) L = Straight Leads LS = Shaped Leads MS = Surface Mount Breakdown Voltage 090 = 90V 230 = 230V 350 = 350V 420 = 420V Lead Option Code SM = Surface Mount (Packaging Option Code is not applicable for SL0902A) Packaging Option Code (Blank) = Bulk (Applies to Core Devices Only) TR = Tape & Reel Packaging Part Number and Device Type Device Dimensions Reference Quantity and Packaging Description CG5xxx Core Outline 501 1000pcs/bag in bulk packaging CG5xxxLS Shaped Leads Outline 500 900pcs/reel in carrier and tape* CG5xxxLTR CG5xxxL-03TR** Straight Axial Leads Outline 502 1000pcs/reel in tape and reel* CG5xxxL-02** Bent Radial Leads Outline 503 50pcs/tray in tray and cover CG5xxxMS SL0902AxxxSM Surface mount Outline 505 900pcs/reel in carrier and tape* * For tape specifications and dimensions, please contact factory. ** Special order items not available for general sale. Please contact Littelfuse for details. © 2015 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 11/06/15