Littelfuse Broadband Optimized™ SL0902A Series offers
high surge ratings in a miniature package. Special design
features provide high levels of protection against fast
rising transients in the 100V/μs to 1kV/μs range usually
caused by lightning disturbances. Low insertion loss is
perfectly suited to broadband equipment applications.
The capacitance does not vary with voltage, and will
not cause operational problems with ADSL2+, where
capacitance variation across Tip and Ring is undesirable.
These devices are extremely robust and are able to
divert a 2500A pulse without destruction. For AC
Power Cross of long duration, overcurrent protection is
recommended.
Agency Approvals
AGENCY
AGENCY FILE NUMBER
E128662 (exception: CG550)
2 Electrode GDT Graphical Symbol
Littelfuse CG5 MS mini surge arresters are specifically
designed for protection of electrical and communication
equipment against over voltage transients in surface
mount assembly applications. This series offers the most
cutting edge protection using non-radioactive elements.
Features
Additional Information
Datasheet
CG5 Series
Resources
CG5 Series
Samples
CG5 Series
Datasheet
SL0902A
Resources
SL0902A
Samples
SL0902A
•RoHS compliant and
Lead-free
•GHz working frequency
•Excellent stability on
multiple pulse duty cycle
•Excellent response to
fast rising transients.
•Ultra Low Insertion Loss
•5KA surge capability
tested with 8/20μS
pulse as defined by IEC
61000-4-5
•Ultra small devices
offered in a variety of
mounting lead forms
•Non-Radioactive
•Low capacitance (<1pF)
•Voltage Ranges 90V to
600V
•UL recognized
•Conforms to ITU-T K12,
IEC 1000-4-5
Applications
•Communication
equipment
•CATV equipment
•Test equipment
•Data lines
•Power supplies
•Telecom SLIC
protection
•Broadband equipment
•ADSL equipment,
including ADSL2+
•XDSL equipment
•Satellite and CATV
equipment
•General telecom
equipment
© 2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/06/15
Gas Discharge Tubes
CG5 and SL0902A Series
Electrical Characteristics
Device Specifications (at 25°C)
DC Breakdown
in Volts
(@100V/s)
(@100V/µs)
Part Number
SL0902A090
CG590
MIN
TYP
Life Ratings
Impulse
Impulse Insulation CapaciBreakdown Breakdown Resistance tance
in Volts
In Volts
(@1MHz)
MAX
(@1 Kv/µsec)
MAX
MIN
108
550
700
10 Ω
(at 50V)
650
72
90
CG5145
116
145
174
550
CG5150
120
150
180
550
SL0902A230
CG5230
184
230
276
550
CG5250
200
250
300
600
CG5270
216
270
324
650
SL0902A350
CG5350
280
350
420
800
CG5400
320
400
480
900
SL0902A420
336
420
504
900
1000
CG5470
376
470
564
1000
1200
SL0902A600
CG5600
480
600
720
1350
1500
Surge
Life
(10/1000µs)
Nominal Nominal
AC
Max
Impulse
AC
Dischage Impulse
Discharge Discharge Current Discharge
Current
Current (9 cycle @50Hz) Current
(8/20µs)
(10x1sec
@50-60Hz)
10 shots
(@5kA)
5A
(1 Application
@ 10/350µs)
MAX
10
650
900
1010 Ω
(at 100V)
1.5 pf
300 shots
(@100A)
10 A
Product Characteristics
CG5xxxLS (Outline 500), CG5xxxxLTR
& CG5350L-03TR (Outline 502), and
CG5xxxL-02 (Outline 503): Device
Nickel Plated 2–5 Microns Wire Tin Plated
17.5±12.5 Microns Construction Ceramic
Insulator.
CG5xxx (Outline 501), and CG5xxxMS
& SL0902AxxxSM (Outline 505):
Device Tin Plated 17.5±12.5 Microns
Construction Ceramic Insulator.
Materials
Product Marking
LF Logo, Voltage and date code
Glow to arc
transition current
< 0.5Amps
Glow Voltage
140 Volts
Storage and
Operational
Temperature
-40 to +90
Typical Insertion Loss
Voltage vs. Time Characteristic
@ 1.0 GHz = 0.01 dB
Max dynamic breakover
voltage
@ 1.4GHz = 0.1 dB
@ 1.8 GHz = 0.53 dB
Voltage
(V)
@ 2.1 GHz = 0.81 dB
@ 2.45 GHz= 1 dB
@ 2.8 GHz = 1.2 dB
Hold-over voltage
@ 3.1 GHz = 1.5 dB
@ 3.5 GHz = 2.1 dB
On-State voltage
0
200
400
600
Time (ns)
© 2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/06/15
800
1000
1200
0.5kA
Gas Discharge Tubes
CG5 and SL0902A Series
Device Dimensions
Outline 500 - CG5xxxLS
Outline 503 - CG5xxxL-02 (except CG5600L-02, see Outline 502)
PROFILE VIEW
TOP VIEW
5.00 ± 0.20
[0.197 ± 0.008]
5.00 ± 0.20
[0.197 ± 0.008]
TOP VIEW
PROFILE VIEW
5.0 ± 0.2
5.30 ± 0.30
[0.209 ± 0.012]
40° ± 3°
[0.197 ± 0.008]
3.0 ± 0.3
[0.118 ± 0.008]
5.30 ± 0.30
0.40 ± 0.03 [0.209 ± 0.012]
[0.016 ± 0.0012]
0.004
2 Surfaces
5.0 ± 0.2
[0.197 ± 0.008]
0.80
[0.031]
0.80DIA. TYP.
[0.031]
6.3 ± 0.2
[2.480 ± 0.079]
8.00 ± 0.30
[0.315 ± 0.012]
9.30 ± 0.30
[0.366 ± 0.012]
Outline 505 - CG5xxxMS and SL0902AxxxSM
SOLDER PAD LAYOUT
PROFILE VIEW
TOP VIEW
8.00
[0.315]
6.6 ± 0.2
[0.260 ± 0.008]
5.50
[0.216]
5.4 ± 0.15
[0.212 ± 0.006]
1.80
[0.071]
0.5 ± 0.1
9.80
[0.386]
[0.02 ± 0.004 ]
5.0 ± 0.2
[0.197 ± 0.008]
Outline 501 - CG5xxx
3.8
[0.15]
5.4 ± 0.15
[0.212 ± 0.006]
SOLDER PAD LAYOUT
4.50
[0.18]
TOP VIEW
PROFILE VIEW
5.10
5.0 ± 0.15
[0.2]
[0.197 ± 0.006]
0.70
[0.028]
5.0 ± 0.2
[0.197 ± 0.008]
Outline 502 - CG5xxxLTR (also CG5350L-03TR, CG5600L-02)
PROFILE VIEW
0.80 DIA. TYP.
[0.024]
TOP VIEW
5.0 ± 0.2
[0.197 ± 0.008]
5.0 ± 0.2
[0.197 ± 0.008]
62 ± 2
[2.441 ± 0.079]
© 2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/06/15
Gas Discharge Tubes
CG5 and SL0902A Series
Soldering Parameters - Reflow Soldering (Surface Mount Devices)
Pb – Free assembly
Pre Heat
- Temperature Min (Ts(min))
150°C
- Temperature Max (Ts(max))
200°C
- Time (Min to Max) (ts)
60 – 180 secs
3°C/second max
TS(max) to TL - Ramp-up Rate
5°C/second max
- Temperature (TL) (Liquidus)
217°C
- Temperature (tL)
60 – 150 seconds
260+0/-5 °C
Time within 5°C of actual peak
Temperature (tp)
10 – 30 seconds
Ramp-down Rate
6°C/second max
Time 25°C to peak Temperature (TP)
8 minutes Max.
Do not exceed
260°C
tL
Ramp-down
Preheat
TS(min)
25
Peak Temperature (TP)
Critical Zone
TL to TP
Ramp-up
TL
TS(max)
Average ramp up rate (Liquidus Temp
(TL) to peak
Reflow
tP
TP
Temperature
Reflow Condition
tS
time to peak temperature
(t 25ºC to peak)
Time
Soldering Parameters - Hand Soldering
Solder Iron Temperature: 350° C +/- 5°C
Heating Time: 5 seconds max.
Soldering Parameters - Wave Soldering (Thru-Hole Devices)
Recommended Process Parameters:
280
Wave Parameter
260
Lead-Free Recommendation
Preheat:
240
220
(Depends on Flux Activation Temperature)
200
180
160
140
120
100
80
60
40
Time (Seconds)
Cooling Time
Preheat Time
Dwell Time
© 2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/06/15
230
240
220
210
200
190
180
170
160
150
140
130
120
110
90
100
80
70
60
50
40
20
0
0
30
20
10
Temperature (°C) - Measured on bottom side of board
300
(Typical Industry Recommendation)
Temperature Minimum:
100° C
Temperature Maximum:
Preheat Time:
150° C
60-180 seconds
Solder Pot Temperature:
280° C Maximum
Solder Dwell Time:
2-5 seconds
Note: These devices are not recommended for IR
or Convection Reflow process.
Gas Discharge Tubes
CG5 and SL0902A Series
Part Numbering System and Ordering Information
CG5 xxx L TR
SL0902A xxx SM
Series
Series
SL0902A
CG5
Breakdown Voltage
90 = 90V
230 = 230V
350 = 350V
600 = 600V
Lead Option Code
(Blank) = Core Device (No Leads)
L = Straight Leads
LS = Shaped Leads
MS = Surface Mount
Breakdown Voltage
090 = 90V
230 = 230V
350 = 350V
420 = 420V
Lead Option Code
SM = Surface Mount
(Packaging Option Code is not applicable for SL0902A)
Packaging Option Code
(Blank) = Bulk (Applies to Core Devices Only)
TR = Tape & Reel
Packaging
Part Number and Device Type
Device Dimensions
Reference
Quantity and Packaging
Description
CG5xxx
Core
Outline 501
1000pcs/bag in bulk packaging
CG5xxxLS
Shaped Leads
Outline 500
900pcs/reel in carrier and tape*
CG5xxxLTR
CG5xxxL-03TR**
Straight Axial Leads
Outline 502
1000pcs/reel in tape and reel*
CG5xxxL-02**
Bent Radial Leads
Outline 503
50pcs/tray in tray and cover
CG5xxxMS
SL0902AxxxSM
Surface mount
Outline 505
900pcs/reel in carrier and tape*
* For tape specifications and dimensions, please contact factory.
** Special order items not available for general sale. Please contact Littelfuse for details.
© 2015 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 11/06/15