DELTA P/N : HMP1350 Series Mechanical dimensions Dimensions (Unit : mm) A 12.7±0.5 B 5.0 MAX C 13.0±0.5 D 2.5 E 2.5 F 2.4 G 7.8 H I J K L M N 3.2 8.0 7.0 14.0 4.4 11.2 3.7 Electrical Characteristics: @25℃, 100KHz, 1V Delta P/N HMP1350M-0R5 HMP1350-0R6 HMP1350-0R7 HMP1350M-1R2L HMP1350-1R0 HMP1350-1R2 HMP1350-1R5 HMP1350-2R0 HMP1350M-2R2 HMP1350-3R3L HMP1350M-4R7 HMP1350-150 1. 2. 3. 4. L1 (uH) 0.50 0.60 0.70 1.20 1.00 1.20 1.50 2.00 2.20 3.30 4.70 15.0 Li (uH)MIN. 0.40 0.48 0.56 0.80 0.80 0.96 1.20 1.60 1.76 2.30 3.76 12.0 DCR (mΩ) MAX 1.3 1.3 1.3 1.3 2.1 2.1 2.1 3.5 4.3 4.3 6.3 26.0 Isat 2 (A) 40 30 30 20 30 25 20 20 18 14 13.5 5.4 Tolerance of inductance : ± 20% Isat is the DC current which cause the inductance drop not less than Li Ir is the DC current which cause the surface temperature of the part increase less than 45 ℃. Operating temperature: -40℃ to 125℃ (Self-temperature rise included). Ir 3 (A) 30 30 30 30 26 26 26 17 15.8 15.8 12.5 7.5