DELTA P/N : HMU1356L eries Mechanical dimensions Dimensions (Unit : mm) A 12.6 ± 0.4 B 12.7 ± 0.3 C 5.6 MAX D 2.65 ± 0.2 E 4.3 ± 0.3 F 2.5 ± 0.2 G 1.8 ± 0.2 H 9.25 ± 0.2 1.4 ± 0.2 3.0 4.0 2.55 2.75 8.2 3.0 I J K L M N 0 Electrical Characteristics: @25℃, 100KHz, 1V Delta P/N HMU1356L-0R6 HMU1356L-1R5 HMU1356L-2R5 HMU1356L-4R0 HMU1356L-6R0 HMU1356L-8R2 HMU1356L-100 L1 (uH) 0.6 1.5 2.5 4.0 6.0 8.2 10 DCR (mΩ) MAX 1.5 2.2 3.4 5.4 8.0 11.4 13.5 Isat 2 (A) 23 14 10 8.3 6.7 5.8 5 Ir 3 (A) 19.5 18 15.5 12.5 9.9 8.2 7.6 1. 2. Tolerance of inductance : ± 20% Isat is the DC current which cause the inductance drop 20% typical of its nominal inductance without current. 3. 4. Ir is the DC current which cause the surface temperature of the part increase less than 45 ℃. Operating temperature: -40℃ to 125℃ (Self-temperature rise included).