IDT IDT82V2051EPP

SINGLE CHANNEL E1 SHORT
HAUL LINE INTERFACE UNIT
IDT82V2051E
FEATURES
•
•
•
•
•
Single channel E1 short haul line interfaces
Supports HPS (Hitless Protection Switching) for 1+1 protection
without external relays
Single 3.3 V power supply with 5 V tolerance on digital interfaces
Meets or exceeds specifications in
- ANSI T1.102
- ITU I.431, G.703, G.736, G.775 and G.823
- ETSI 300-166, 300-233 and TBR12/13
Software programmable or hardware selectable on:
- Wave-shaping templates
- Line terminating impedance (75 Ω/120 Ω)
- Adjustment of arbitrary pulse shape
- JA (Jitter Attenuator) position (receive path or transmit path)
- Single rail/dual rail system interfaces
- HDB3/AMI line encoding/decoding
- Active edge of transmit clock (TCLK) and receive clock (RCLK)
- Active level of transmit data (TDATA) and receive data (RDATA)
- Receiver or transmitter power down
•
•
•
•
•
- High impedance setting for line drivers
- PRBS (Pseudo Random Bit Sequence) generation and detection
with 215-1 PRBS polynomials
- 16-bit BPV (Bipolar Pulse Violation) /Excess Zero/PRBS error
counter
- Analog loopback, Digital loopback, Remote loopback
Short circuit protection and internal protection diode for line
drivers
AIS (Alarm Indication Signal) detection
Supports serial control interface, Motorola and Intel Multiplexed
interfaces and hardware control mode
Pin compatibe to 82V2081 T1/E1/J1 Long Haul/Short Haul LIU
and 82V2041E T1/E1/J1 Short Haul LIU
Package:
Available in 44-pin TQFP packages
Green package options available
DESCRIPTION
circuit is integrated in the chip, and different types of loopbacks can be set
according to the applications. Two different kinds of line terminating impedance, 75 Ω and 120 Ω are selectable. The chip also provides driver shortcircuit protection and internal protection diode. The chip can be controlled
by either software or hardware.
The IDT82V2051E is a single channel E1 Line Interface Unit. The
IDT82V2051E performs clock/data recovery, AMI/HDB3 line decoding and
detects and reports the LOS conditions. An integrated Adaptive Equalizer
is available to increase the receive sensitivity and enable programming of
LOS levels. In transmit path, there is an AMI/HDB3 encoder and Waveform
Shaper. There is one Jitter Attenuator, which can be placed in either the
receive path or the transmit path. The Jitter Attenuator can also be disabled.
The IDT82V2051E supports both Single Rail and Dual Rail system interfaces. To facilitate the network maintenance, a PRBS generation/detection
The IDT82V2051E can be used in LAN, WAN, Routers, Wireless Base
Stations, IADs, IMAs, IMAPs, Gateways, Frame Relay Access Devices,
CSU/DSU equipment, etc.
IDT and the IDT logo are trademarks of Integrated Device Technology, Inc.
1
 2005 Integrated Device Technology, Inc.
December 9, 2005
DSC-6528/2
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
FUNCTIONAL BLOCK DIAGRAM
LOS/AIS
Detector
LOS
RCLK
RD/RDP
CV/RDN
PRBS Detector
TCLK
TD/TDP
TDN
Data and
Clock
Recovery
Jitter
Attenuator
HDB3/AMI
Decoder
Remote
Loopback
Receiver
Internal
Termination
RTIP
RRING
Analog
Loopback
Digital
Loopback
Jitter
Attenuator
HDB3/AMI
Decoder
Adaptive
Equalizer
Data
Slicer
TTIP
Transmitter
Internal
Termination
Line
Driver
Waveform
Shaper
TRING
PRBS Generator
TAOS
Register
Files
Pin Control
MODE[1:0]
TERM
RXTXM[1:0]
PULS
PATT[1:0]
JA[1:0]
MONT
LP[1:0]
THZ
RCLKE
RPD
RST
AD[7:0]
SDI/ WR /R/W
RD / DS / SCLKE
SCLK/ALE/AS
CS
SDO / ACK / RDY
Software Control Interface
INT
MCLK
Clock
Generator
VDDIO
VDDD
VDDA
VDDT
Figure-1 Block Diagram
Functional Block Diagram
2
December 9, 2005
Table of Contents
1
IDT82V2051E Pin Configurations ............................................................................................... 8
2
Pin Description ............................................................................................................................ 9
3
Functional Description .............................................................................................................. 15
3.1
Control Mode Selection .................................................................................................... 15
3.2
Transmit Path ................................................................................................................... 15
3.2.1 Transmit Path System Interface.............................................................................. 15
3.2.2 Encoder.................................................................................................................. 15
3.2.3 Pulse Shaper .......................................................................................................... 15
3.2.3.1 Preset Pulse Templates .......................................................................... 15
3.2.3.2 User-Programmable Arbitrary Waveform ................................................ 16
3.2.4 Transmit Path Line Interface................................................................................... 17
3.2.5 Transmit Path Power Down .................................................................................... 17
3.3
Receive Path .................................................................................................................... 18
3.3.1 Receive Internal Termination .................................................................................. 18
3.3.2 Line Monitor ............................................................................................................ 19
3.3.3 Adaptive Equalizer .................................................................................................. 20
3.3.4 Receive Sensitivity.................................................................................................. 20
3.3.5 Data Slicer .............................................................................................................. 20
3.3.6 CDR (Clock & Data Recovery)................................................................................ 20
3.3.7 Decoder .................................................................................................................. 20
3.3.8 Receive Path System Interface............................................................................... 21
3.3.9 Receive Path Power Down ..................................................................................... 21
3.4
Jitter Attenuator ................................................................................................................ 21
3.4.1 Jitter Attenuation Function Descripton .................................................................... 21
3.4.2 Jitter Attenuator Performance ................................................................................. 22
3.5
Los And AIS Detection ...................................................................................................... 22
3.5.1 LOS Detection......................................................................................................... 22
3.5.2 AIS Detection .......................................................................................................... 23
3.6
Transmit And Detect Internal Patterns .............................................................................. 24
3.6.1 Transmit All Ones ................................................................................................... 24
3.6.2 Transmit All Zeros................................................................................................... 24
3.6.3 PRBS Generation And Detection............................................................................ 24
3.7
Loopback .......................................................................................................................... 24
3.7.1 Analog Loopback .................................................................................................... 24
3.7.2 Digital Loopback ..................................................................................................... 24
3.7.3 Remote Loopback................................................................................................... 24
3.8
Error Detection/Counting And Insertion ............................................................................ 27
Table of Contents
3
December 9, 2005
IDT82V2051E
3.9
3.10
3.11
3.12
3.13
3.14
3.15
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
3.8.1 Definition Of Line Coding Error ............................................................................... 27
3.8.2 Error Detection And Counting ................................................................................. 27
3.8.3 Bipolar Violation And PRBS Error Insertion ............................................................ 28
Line Driver Failure Monitoring ........................................................................................... 28
MCLK And TCLK .............................................................................................................. 29
3.10.1 Master Clock (MCLK).............................................................................................. 29
3.10.2 Transmit Clock (TCLK) ........................................................................................... 29
Microcontroller Interfaces ................................................................................................. 30
3.11.1 Parallel Microcontroller Interface ............................................................................ 30
3.11.2 Serial Microcontroller Interface ............................................................................... 30
Interrupt Handling ............................................................................................................. 30
5V Tolerant I/O Pins ......................................................................................................... 31
Reset Operation ................................................................................................................ 31
Power Supply .................................................................................................................... 31
4
Programming Information ........................................................................................................ 32
4.1
Register List And Map ...................................................................................................... 32
4.2
Reserved Registers .......................................................................................................... 32
4.3
Register Description ......................................................................................................... 33
4.3.1 Control Registers .................................................................................................... 33
4.3.2 Transmit Path Control Registers............................................................................. 35
4.3.3 Receive Path Control Registers.............................................................................. 37
4.3.4 Network Diagnostics Control Registers .................................................................. 39
4.3.5 Interrupt Control Registers...................................................................................... 41
4.3.6 Line Status Registers.............................................................................................. 43
4.3.7 Interrupt Status Registers ....................................................................................... 45
4.3.8 Counter Registers ................................................................................................... 46
5
Hardware Control Pin Summary .............................................................................................. 47
6
Test Specifications .................................................................................................................... 49
7
Microcontroller Interface Timing Characteristics ................................................................... 56
7.1
Serial Interface Timing ...................................................................................................... 56
7.2
Parallel Interface Timing ................................................................................................... 57
Table of Contents
4
December 9, 2005
List of Tables
Table-1
Table-2
Table-3
Table-4
Table-5
Table-6
Table-7
Table-8
Table-9
Table-10
Table-11
Table-12
Table-13
Table-14
Table-15
Table-16
Table-17
Table-18
Table-19
Table-20
Table-21
Table-22
Table-23
Table-24
Table-25
Table-26
Table-27
Table-28
Table-29
Table-30
Table-31
Table-32
Table-33
Table-34
Table-35
Table-36
Table-37
Table-38
Table-39
Table-40
Table-41
List of Tables
Pin Description ................................................................................................................ 9
Transmit Waveform Value For E1 75 ohm.................................................................... 16
Transmit Waveform Value For E1 120 ohm.................................................................. 16
Impedance Matching for Transmitter ............................................................................ 17
Impedance Matching for Receiver ................................................................................ 18
Criteria of Starting Speed Adjustment........................................................................... 22
LOS Declare and Clear Criteria, Adaptive Equalizer Disabled ..................................... 22
LOS Declare and Clear Criteria, Adaptive Equalizer Enabled ...................................... 23
AIS Condition ................................................................................................................ 23
Criteria for Setting/Clearing the PRBS_S Bit ................................................................ 24
EXZ Definition ............................................................................................................... 27
Interrupt Event............................................................................................................... 31
Register List and Map ................................................................................................... 32
ID: Device Revision Register ........................................................................................ 33
RST: Reset Register ..................................................................................................... 33
GCF: Global Configuration Register ............................................................................. 33
TERM: Transmit and Receive Termination Configuration Register .............................. 33
JACF: Jitter Attenuation Configuration Register ........................................................... 34
TCF0: Transmitter Configuration Register 0 ................................................................. 35
TCF1: Transmitter Configuration Register 1 ................................................................. 35
TCF2: Transmitter Configuration Register 2 ................................................................. 35
TCF3: Transmitter Configuration Register 3 ................................................................. 36
TCF4: Transmitter Configuration Register 4 ................................................................. 36
RCF0: Receiver Configuration Register 0..................................................................... 37
RCF1: Receiver Configuration Register 1..................................................................... 37
RCF2: Receiver Configuration Register 2..................................................................... 38
MAINT0: Maintenance Function Control Register 0...................................................... 39
MAINT1: Maintenance Function Control Register 1...................................................... 39
MAINT6: Maintenance Function Control Register 6...................................................... 39
INTM0: Interrupt Mask Register 0 ................................................................................. 41
INTM1: Interrupt Masked Register 1 ............................................................................. 41
INTES: Interrupt Trigger Edge Select Register ............................................................. 42
STAT0: Line Status Register 0 (real time status monitor)............................................. 43
STAT1: Line Status Register 1 (real time status monitor)............................................. 44
INTS0: Interrupt Status Register 0 ................................................................................ 45
INTS1: Interrupt Status Register 1 ................................................................................ 45
CNT0: Error Counter L-byte Register 0......................................................................... 46
CNT1: Error Counter H-byte Register 1 ........................................................................ 46
Hardware Control Pin Summary ................................................................................... 47
Absolute Maximum Rating ............................................................................................ 49
Recommended Operation Conditions ........................................................................... 49
5
December 9, 2005
IDT82V2051E
Table-42
Table-43
Table-44
Table-45
Table-46
Table-47
Table-48
Table-49
Table-50
Table-51
Table-52
Table-53
List of Tables
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Power Consumption......................................................................................................
DC Characteristics ........................................................................................................
Receiver Electrical Characteristics................................................................................
Transmitter Electrical Characteristics............................................................................
Transmitter and Receiver Timing Characteristics .........................................................
Jitter Tolerance .............................................................................................................
Jitter Attenuator Characteristics ....................................................................................
Serial Interface Timing Characteristics .........................................................................
Multiplexed Motorola Read Timing Characteristics.......................................................
Multiplexed Motorola Write Timing Characteristics .......................................................
Multiplexed Intel Read Timing Characteristics ..............................................................
Multiplexed Intel Write Timing Characteristics ..............................................................
6
50
50
50
51
52
53
54
56
57
58
59
60
December 9, 2005
List of Figures
Figure-1
Figure-2
Figure-3
Figure-4
Figure-5
Figure-6
Figure-7
Figure-8
Figure-9
Figure-10
Figure-11
Figure-12
Figure-13
Figure-14
Figure-15
Figure-16
Figure-17
Figure-18
Figure-19
Figure-20
Figure-21
Figure-22
Figure-23
Figure-24
Figure-25
Figure-26
Figure-27
Figure-28
List of Figures
Block Diagram ................................................................................................................. 2
IDT82V2051E TQFP44 Package Pin Assignment .......................................................... 8
E1 Waveform Template Diagram .................................................................................. 15
E1 Pulse Template Test Circuit ..................................................................................... 15
Receive Monitor Gain Adaptive Equalizer ..................................................................... 18
Transmit/Receive Line Circuit ....................................................................................... 18
Monitoring Receive Line in Another Chip ...................................................................... 19
Monitor Transmit Line in Another Chip .......................................................................... 19
Jitter Attenuator ............................................................................................................. 21
LOS Declare and Clear ................................................................................................. 22
Analog Loopback .......................................................................................................... 25
Digital Loopback ............................................................................................................ 25
Remote Loopback ......................................................................................................... 26
Auto Report Mode ......................................................................................................... 27
Manual Report Mode ..................................................................................................... 28
TCLK Operation Flowchart ............................................................................................ 29
Serial Microcontroller Interface Function Timing ........................................................... 30
Transmit System Interface Timing ................................................................................ 52
Receive System Interface Timing ................................................................................. 53
E1 Jitter Tolerance Performance .................................................................................. 54
E1 Jitter Transfer Performance ..................................................................................... 55
Serial Interface Write Timing ......................................................................................... 56
Serial Interface Read Timing with SCLKE=1 ................................................................ 56
Serial Interface Read Timing with SCLKE=0 ................................................................ 56
Multiplexed Motorola Read Timing ................................................................................ 57
Multiplexed Motorola Write Timing ................................................................................ 58
Multiplexed Intel Read Timing ....................................................................................... 59
Multiplexed Intel Write Timing ....................................................................................... 60
7
December 9, 2005
IDT82V2051E
AD7
AD6
AD5
AD4 / PULS
AD3
AD2 / RPD
AD1 / PATT1
AD0 / PATT0
ALE / AS / SCLK/ LP1
WR / R/W / SDI / LP0
RDY / ACK / SDO / TERM
33
32
31
30
29
28
27
26
25
24
23
IDT82V2051E PIN CONFIGURATIONS
IC
34
22
RD / DS / SCLKE / MONT
VDDT
35
21
CS / RXTXM1
TRING
36
20
INT / RXTXM0
TTIP
37
19
VDDIO
18
GNDIO
17
MODE1
GNDT
38
GNDA
39
RRING
40
16
MODE0
RTIP
41
15
JA1
VDDA
42
14
JA0
REF
43
13
THZ
IC
44
12
RST
9
10
11
GNDD
RCLKE
6
RDN / CV
MCLK
5
RDP / RD
8
4
RCLK
7
3
TDN
LOS
2
TDP / TD
VDDD
1
IDT82V2051E
TCLK
1
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Figure-2 IDT82V2051E TQFP44 Package Pin Assignment
IDT82V2051E Pin Configurations
8
December 9, 2005
IDT82V2051E
2
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
PIN DESCRIPTION
Table-1 Pin Description
Name
Type
Pin No.
Description
TTIP
TRING
Analog
output
37
36
TTIP/TRING: Transmit Bipolar Tip/Ring
These pins are the differential line driver outputs. They will be in high impedance state under the following conditions:
•
THZ pin is high;
•
THZ bit is set to 1;
•
Loss of MCLK;
•
Loss of TCLK (exceptions: Remote Loopback; transmit internal pattern by MCLK);
•
Transmit path power down;
•
After software reset; pin reset and power on.
RTIP
RRING
Analog
input
41
40
RTIP/RRING: Receive Bipolar Tip/Ring
These signals are the differential receiver inputs.
TD/TDP
TDN
I
2
3
TD: Transmit Data
When the device is in single rail mode, the NRZ data to be transmitted is input on this pin. Data on TD pin is sampled into the
device on the active edge of TCLK and is encoded by AMI or HDB3 line code rules before being transmitted. In this mode, TDN
should be connected to ground.
TDP/TDN: Positive/Negative Transmit Data
When the device is in dual rail mode, the NRZ data to be transmitted for positive/negative pulse is input on these pins. Data
on TDP/TDN pin is sampled into the device on the active edge of TCLK. The line code in dual rail mode is as follows:
TDP
TDN
Output Pulse
0
0
Space
0
1
Positive Pulse
1
0
Negative Pulse
1
1
Space
TCLK
I
1
TCLK: Transmit Clock input
This pin inputs a 2.048 MHz transmit clock. The transmit data at TD/TDP or TDN is sampled into the device on the active edge
of TCLK. If TCLK is missing1 and the TCLK missing interrupt is not masked, an interrupt will be generated.
RD/RDP
CV/RDN
O
5
6
RD: Receive Data output
In single rail mode, this pin outputs NRZ data. The data is decoded according to AMI or HDB3 line code rules.
CV: Code Violation indication
In single rail mode, the BPV/CV code violation will be reported by driving the CV pin to high level for a full clock cycle. HDB3
line code violation can be indicated if the HDB3 decoder is enabled. When AMI decoder is selected, bipolar violation will be indicated.
In hardware control mode, the EXZ, BPV/CV errors in received data stream are always monitored by the CV pin if single rail
mode is chosen.
RDP/RDN: Positive/Negative Receive Data output
In dual rail mode, this pin outputs the re-timed NRZ data when CDR is enabled, or directly outputs the raw RZ slicer data if CDR
is bypassed.
Active edge and level select:
Data on RDP/RDN or RD is clocked with either the rising or the falling edge of RCLK. The active polarity is also selectable.
RCLK
O
4
RCLK: Receive Clock output
This pin outputs a 2.048 MHz receive clock. Under LOS condition with AIS enabled (bit AISE=1), RCLK is derived from MCLK.
In clock recovery mode, this signal provides the clock recovered from the RTIP/RRING signal. The receive data (RD in single
rail mode or RDP and RDN in dual rail mode) is clocked out of the device on the active edge of RCLK. If clock recovery is
bypassed, RCLK is the exclusive OR (XOR) output of the dual rail slicer data RDP and RDN. This signal can be used in applications with external clock recovery circuitry.
Notes:
1. TCLK missing: the state of TCLK continues to be high level or low level over 70 MCLK cycles.
Pin Description
9
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-1 Pin Description (Continued)
Name
Type
Pin No.
Description
MCLK
I
9
MCLK: Master Clock input
A built-in clock system that accepts a 2.048MHz reference clock. This reference clock is used to generate several internal reference signals:
•
Timing reference for the integrated clock recovery unit.
•
Timing reference for the integrated digital jitter attenuator.
•
Timing reference for microcontroller interface.
•
Generation of RCLK signal during a loss of signal condition.
•
Reference clock to transmit All Ones, all zeros and PRBS pattern. Note that for ATAO and AIS, MCLK is always used as
the reference clock.
•
Reference clock during the Transmit All Ones (TAO) condition or sending PRBS in hardware control mode.
The loss of MCLK will turn TTIP/TRING into high impedance status.
LOS
O
7
LOS: Loss of Signal Output
This is an active high signal used to indicate the loss of received signal. When LOS pin becomes high, it indicates the loss of
received signal. The LOS pin will become low automatically when valid received signal is detected again. The criteria of loss
of signal are described in 3.5 Los And AIS Detection.
REF
I
43
REF: reference resister
An external resistor (3 KΩ, 1%) is used to connect this pin to ground to provide a standard reference current for internal circuit.
MODE1
MODE0
I
17
16
MODE[1:0]: operation mode of Control interface select
The level on this pin determines which control mode is used to control the device as follows:
MODE[1:0]
•
•
•
Control Interface mode
00
Hardware interface
01
Serial Microcontroller Interface
10
Parallel –Multiplexed -Motorola Interface
11
Parallel –Multiplexed -Intel Interface
The serial microcontroller Interface consists of CS, SCLK, SCLKE, SDI, SDO and INT pins. SCLKE is used for the
selection of the active edge of SCLK.
The parallel multiplexed microcontroller interface consists of CS, AD[7:0], DS/RD, R/W/WR, ALE/AS, ACK/RDY and
INT pins. (refer to 3.11 Microcontroller Interfaces for details)
Hardware interface consists of PULS, THZ, RCLKE, LP[1:0], PATT[1:0], JA[1:0], MONT, TERM, RPD, MODE[1:0] and
RXTXM[1:0]
RCLKE
I
11
RCLKE: the active edge of RCLK select
In hardware control mode, this pin selects the active edge of RCLK
•
L= select the rising edge as the active edge of RCLK
•
H= select the falling edge as the active edge of RCLK
In software control mode, this pin should be connected to GNDIO.
CS
I
21
CS: Chip Select
In serial or parallel microcontroller interface mode, this is the active low enable signal. A low level on this pin enables serial or
parallel microcontroller interface.
RXTXM1
Pin Description
RXTXM[1:0]: Receive and transmit path operation mode select
In hardware control mode, these pins are used to select the single rail or dual rail operation modes as well as AMI or HDB3 line
coding:
•
00= single rail with HDB3 coding
•
01= single rail with AMI coding
•
10= dual rail interface with CDR enabled
•
11= slicer mode (dual rail interface with CDR disabled)
10
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-1 Pin Description (Continued)
Name
Type
Pin No.
Description
INT
O
20
INT: Interrupt Request
In software control mode, this pin outputs the general interrupt request for all interrupt sources. These interrupt sources can be
masked individually via registers (INTM0, 14H) and (INTM1, 15H). The interrupt status is reported via the registers (INTS0,
19H) and (INTS1, 1AH).
Output characteristics of this pin can be defined to be push-pull (active high or active low) or open-drain (active low) by setting
INT_PIN[1:0] (GCF, 02H).
RXTXM0
I
SCLK
I
RXTXM0
See RXTXM1 above.
25
SCLK: Shift Clock
In serial microcontroller interface mode, this signal is the shift clock for the serial interface. Configuration data on SDI pin is sampled on the rising edge of SCLK. Configuration and status data on SDO pin is clocked out of the device on the falling edge of
SCLK if SCLKE pin is high, or on the rising edge of SCLK if SCLKE pin is low.
ALE
ALE: Address Latch Enable
In parallel microcontroller interface mode with multiplexed Intel interface, the address on AD[7:0] is sampled into the device on
the falling edge of ALE.
AS
AS: Address Strobe
In parallel microcontroller interface mode with multiplexed Motorola interface, the address on AD[7:0] is latched into the device
on the falling edge of AS.
LP1
LP[1:0]: Loopback mode select
When the chip is configured by hardware, this pin is used to select loopback operation modes:
•
00= no loopback
•
01= analog loopback
•
10= digital loopback
•
11= remote loopback
SDI
I
24
SDI: Serial Data Input
In serial microcontroller interface mode, this signal is the input data to the serial interface. Configuration data at SDI pin is sampled by the device on the rising edge of SCLK.
WR
WR: Write Strobe
In Intel parallel multiplexed interface mode, this pin is asserted low by the microcontroller to initiate a write cycle. The data on
AD[7:0] is sampled into the device in a write operation.
R/W
R/W: Read/Write Select
In Motorola parallel multiplexed interface mode, this pin is low for write operation and high for read operation.
LP0
LP0
See LP1 above.
Pin Description
11
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-1 Pin Description (Continued)
Name
Type
Pin No.
Description
SDO
O
23
SDO: Serial Data Output
In serial microcontroller interface mode, this signal is the output data of the serial interface. Configuration or Status data at SDO
pin is clocked out of the device on the falling edge of SCLK if SCLKE pin is high, or on the rising edge of SCLK if SCLKE pin
is low.
ACK
ACK: Acknowledge Output
In Motorola parallel mode interface, the low level on this pin means:
•
The valid information is on the data bus during a read operation.
•
The write data has been accepted during a write cycle.
RDY
RDY: Ready signal output
In Intel parallel mode interface, the low level on this pin means a read or write operation is in progress; a high acknowledges
a read or write operation has been completed.
TERM
I
SCLKE
I
TERM: Internal or external termination select in hardware mode
This pin selects internal or external impedance matching for both receiver and transmitter.
•
0 = ternary interface with external impedance matching network
•
1 = ternary interface with internal impedance matching network
22
SCLKE: Serial Clock Edge Select
In serial microcontroller interface mode, this signal selects the active edge of SCLK for outputting SDO. The output data is valid
after some delay from the active clock edge. It can be sampled on the opposite edge of the clock. The active clock edge which
clocks the data out of the device is selected as shown below:
SCLKE
SCLK
Low
Rising edge is the active edge.
High
Falling edge is the active edge.
RD
RD: Read Strobe
In Intel parallel multiplexed interface mode, the data is driven to AD[7:0] by the device during low level of RD in a read operation.
DS
DS: Data Strobe
In Motorola parallel multiplexed interface mode, this signal is the data strobe of the parallel interface. In a write operation (R/
W = 0), the data on AD[7:0] is sampled into the device. In a read operation (R/W = 1), the data is driven to AD[7:0] by the device.
MONT: Receive Monitor gain select
In hardware control mode with ternary interface, this pin selects the receive monitor gain of receiver:
0= 0 dB
1= 26 dB
MONT
AD7
I/O
33
AD6
I/O
32
AD7: Address/Data Bus bit7
In Intel/Motorola multiplexed interface mode, this signal is the multiplexed bi-directional address/data bus of the microcontroller
interface.
In serial microcontroller interface mode, this pin should be connected to ground through a 10 kΩ resistor.
In Hardware mode, this pin has to be tied to GND.
AD6: Address/Data Bus bit6
In Intel/Motorola multiplexed interface mode, this signal is the multiplexed bi-directional address/data bus of the microcontroller
interface.
In serial microcontroller interface mode, this pin should be connected to ground through a 10 kΩ resistor.
In Hardware mode, this pin has to be tied to GND.
Pin Description
12
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-1 Pin Description (Continued)
Name
Type
Pin No.
Description
AD5
I/O
31
AD5: Address/Data Bus bit5
In Intel/Motorola multiplexed interface mode, this signal is the multiplexed bi-directional address/data bus of the microcontroller
interface.
In serial microcontroller interface mode, this pin should be connected to ground through a 10 kΩ resistor.
In Hardware mode, this pin has to be tied to GND.
AD4
I/O
30
AD4: Address/Data Bus bit4
In Intel/Motorola multiplexed interface mode, this signal is the multiplexed bi-directional address/data bus of the microcontroller
interface.
In serial microcontroller interface mode, this pin should be connected to ground through a 10 kΩ resistor.
PULS: this pin is used to select the following functions in hardware control mode:
•
Transmit pulse template
•
Internal termination impedance (75 Ω / 120 Ω)
Refer to 5 Hardware Control Pin Summary for details.
AD3
I/O
29
AD3: Address/Data Bus bit3
In Intel/Motorola multiplexed interface mode, this signal is the multiplexed bi-directional address/data bus of the microcontroller
interface.
In serial microcontroller interface mode, this pin should be connected to ground through a 10 kΩ resistor.
AD2
I/O
28
AD2: Address/Data Bus bit2
In Intel/Motorola multiplexed interface mode, this signal is the multiplexed bi-directional address/data bus of the microcontroller
interface.
In serial microcontroller interface mode, this pin should be connected to ground through a 10 kΩ resistor.
RPD
I
AD1
I/O
PATT1
I
AD0
I/O
PATT0
I
JA1
I
15
JA[1:0]: Jitter attenuation position, bandwidth and the depth of FIFO select (only used for hardware control mode)
•
00 = JA is disabled
•
01 = JA in receiver, broad bandwidth, FIFO=64 bits
•
10 = JA in receiver, narrow bandwidth, FIFO=128 bits
•
11 = JA in transmitter, narrow bandwidth, FIFO=128 bits
In software control mode, this pin should be connected to ground.
JA0
I
14
See above.
Pin Description
RPD: Receiver power down control in hardware control mode
•
0= normal operation
•
1= receiver power down
27
AD1: Address/Data Bus bit1
In Intel/Motorola multiplexed interface mode, this signal is the multiplexed bi-directional address/data bus of the microcontroller
interface.
In serial microcontroller interface mode, this pin should be connected to ground through a 10 kΩ resistor.
PATT[1:0]: Transmit pattern select
In hardware control mode, this pin selects the transmit pattern
•
00 = normal
•
01= All Ones
•
10= PRBS
•
11= transmitter power down
26
AD0: Address/Data Bus bit0
In Intel/Motorola multiplexed interface mode, this signal is the multiplexed bi-directional address/data bus of the microcontroller
interface.
In serial microcontroller interface mode, this pin should be connected to ground through a 10 kΩ resistor.
See above.
13
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-1 Pin Description (Continued)
Name
Type
Pin No.
RST
I
12
RST: Hardware reset
The chip is forced to reset state if a low signal is input on this pin for more than 100 ns. MCLK must be active during reset.
Description
THZ
I
13
THZ: Transmitter Driver High Impedance Enable
This signal enables or disables transmitter driver. A low level on this pin enables the driver while a high level on this pin places
driver in high impedance state. Note that the functionality of the internal circuits is not affected by this signal.
VDDIO
-
19
3.3 V I/O power supply
Power Supplies and Grounds
GNDIO
-
18
I/O ground
VDDT
-
35
3.3 V power supply for transmitter driver
GNDT
-
38
Analog ground for transmitter driver
VDDA
-
42
3.3 V analog core power supply
GNDA
-
39
Analog core ground
VDDD
-
8
Digital core power supply
GNDD
-
10
Digital core ground
Others
IC
-
34
IC: Internal connection
Internal Use. This pin should be left open when in normal operation.
IC
-
44
IC: Internal connection
Internal Use. This pin should be connected to ground when in normal operation.
Pin Description
14
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
3
FUNCTIONAL DESCRIPTION
3.1
CONTROL MODE SELECTION
in a positive pulse on the TTIP/TRING. If both TDP and TDN are high or low,
the TTIP/TRING outputs a space (Refer to TD/TDP, TDN Pin Description).
In hardware control mode, the operation mode of receive and transmit
path can be selected by setting RXTXM1 and RXTXM0 pins. Refer to 5
Hardware Control Pin Summary for details.
The IDT82V2051E can be configured by software or by hardware. The
software control mode supports Serial Control Interface, Motorola Multiplexed Control Interface and Intel Multiplexed Control Interface. The Control mode is selected by MODE1 and MODE0 pins as follows:
3.2.3
The IDT82V2051E provides two ways of manipulating the pulse shape
before sending it. One is to use preset pulse templates, the other is to use
user-programmable arbitrary waveform template.
Control Interface mode
•
00
Hardware interface
01
Serial Microcontroller Interface.
10
Parallel –Multiplexed -Motorola Interface
11
Parallel –Multiplexed -Intel Interface
In software control mode, the pulse shape can be selected by setting
the related registers.
In hardware control mode, the pulse shape can be selected by setting
PULS pin. Refer to 5 Hardware Control Pin Summary for details.
The serial microcontroller Interface consists of CS, SCLK, SCLKE,
SDI, SDO and INT pins. SCLKE is used for the selection of active
edge of SCLK.
The parallel Multiplexed microcontroller Interface consists of CS,
AD[7:0], DS/RD, R/W/WR, ALE/AS, ACK/RDY and INT pins.
Hardware interface consists of PULS, THZ, RCLKE, LP[1:0],
PATT[1:0], JA[1:0], MONT, TERM, RPD, MODE[1:0] and
RXTXM[1:0]. Refer to 5 Hardware Control Pin Summary for details
about hardware control.
•
•
3.2
PULSE SHAPER
3.2.3.1 PRESET PULSE TEMPLATES
The pulse shape is shown in Figure-3 according to the G.703 and the
measuring diagram is shown in Figure-4. In internal impedance matching
mode, if the cable impedance is 75 Ω, the PULS[3:0] bits (TCF1, 06H)
should be set to ‘0000’; if the cable impedance is 120 Ω, the PULS[3:0] bits
(TCF1, 06H) should be set to ‘0001’. In external impedance matching mode,
for both E1/75 Ω and E1/120 Ω cable impedance, PULS[3:0] should be set
to ‘0001’.
TRANSMIT PATH
1 .2 0
The transmit path of IDT82V2051E consists of an Encoder, an optional
Jitter Attenuator, a Waveform Shaper, a Line Driver and a Programmable
Transmit Termination.
1 .0 0
0 .8 0
TRANSMIT PATH SYSTEM INTERFACE
Normalized Amplitude
3.2.1
The transmit path system interface consists of TCLK pin, TD/TDP pin
and TDN pin. TCLK is a 2.048 MHz clock. If TCLK is missing for more than
70 MCLK cycles, an interrupt will be generated if it is not masked.
0 .0 0
-0 .2 0
- 0 .6
-0 .4
-0 .2
0
0 .2
0 .6
0 .4
T im e in U n it In te rv a ls
Figure-3 E1 Waveform Template Diagram
The transmit data from the system side can be provided in two different
ways: Single Rail and Dual Rail. In Single Rail mode, only TD pin is used
for transmitting data and the T_MD[1] bit (TCF0, 05H) should be set to ‘0’.
In Dual Rail Mode, both TDP pin and TDN pin are used for transmitting data,
the T_MD[1] bit (TCF0, 05H) should be set to ‘1’.
TTIP
IDT82V2051E
ENCODER
RLOAD
VOUT
TRING
In Single Rail mode, the Encoder can be configured to be a HDB3
encoder or an AMI encoder by setting T_MD[0] bit (TCF0, 05H).
Note: 1. For RLOAD = 75 Ω (nom), Vout (Peak) = 2.37 V (nom)
2. For RLOAD = 120 Ω (nom), Vout (Peak) = 3.00 V (nom)
In Dual Rail mode, the Encoder is by-passed. In Dual Rail mode, a logic
‘1’ on the TDP pin and a logic ‘0’ on the TDN pin results in a negative pulse
on the TTIP/TRING; a logic ‘0’ on TDP pin and a logic ‘1’ on TDN pin results
Functional Description
0 .4 0
0 .2 0
Transmit data is sampled on the TD/TDP and TDN pins by the active
edge of TCLK. The active edge of TCLK can be selected by the TCLK_SEL
bit (TCF0, 05H). And the active level of the data on TD/TDP and TDN can
be selected by the TD_INV bit (TCF0, 05H). In hardware control mode, the
falling edge of TCLK and the active high of transmit data are always used.
3.2.2
0 .6 0
Figure-4 E1 Pulse Template Test Circuit
15
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
The following tables give all the sample data based on the preset pulse
templates in detail for reference. For preset pulse templates, scaling up/
down against the pulse amplitude is not supported.
1.Table-2 Transmit Waveform Value For E1 75 Ω
2.Table-3 Transmit Waveform Value For E1 120 Ω
3.2.3.2 USER-PROGRAMMABLE ARBITRARY WAVEFORM
When the PULS[3:0] bits are set to ‘11xx’, user-programmable arbitrary
waveform generator mode can be used. This allows the transmitter performance to be tuned for a wide variety of line condition or special application.
Each pulse shape can extend up to 4 UIs (Unit Interval), addressed by
UI[1:0] bits (TCF3, 08H) and each UI is divided into 16 sub-phases,
addressed by the SAMP[3:0] bits (TCF3, 08H). The pulse amplitude of each
phase is represented by a binary byte, within the range from +63 to -63,
stored in WDAT[6:0] bits (TCF4, 09H) in signed magnitude form. The most
positive number +63 (D) represents the positive maximum amplitude of the
transmit pulse while the most negative number -63 (D) represents the maximum negative amplitude of the transmit pulse. Therefore, up to 64 bytes
are used.
There are two standard templates which are stored in an on-chip ROM.
User can select one of them as reference and make some changes to get
the desired waveform.
Table-2 Transmit Waveform Value For E1 75 ohm
User can change the wave shape and the amplitude to get the desired
pulse shape. In order to do this, firstly, users can choose a set of waveform
value from the following two tables, which is the most similar to the desired
pulse shape. Table-2 and Table-3 list the sample data and scaling data of
each of the two templates. Then modify the corresponding sample data to
get the desired transmit pulse shape.
Secondly, through the value of SCAL[5:0] bits increased or decreased
by 1, the pulse amplitude can be scaled up or down at the percentage ratio
against the standard pulse amplitude if needed. For different pulse shapes,
the value of SCAL[5:0] bits and the scaling percentage ratio are different.
The following two tables list these values.
Sample
UI 1
UI 2
UI 3
UI 4
1
0000000
0000000
0000000
0000000
2
0000000
0000000
0000000
0000000
3
0000000
0000000
0000000
0000000
4
0001100
0000000
0000000
0000000
5
0110000
0000000
0000000
0000000
6
0110000
0000000
0000000
0000000
7
0110000
0000000
0000000
0000000
8
0110000
0000000
0000000
0000000
9
0110000
0000000
0000000
0000000
10
0110000
0000000
0000000
0000000
11
0110000
0000000
0000000
0000000
12
0110000
0000000
0000000
0000000
13
0000000
0000000
0000000
0000000
14
0000000
0000000
0000000
0000000
15
0000000
0000000
0000000
0000000
16
0000000
0000000
0000000
0000000
SCAL[5:0] = 100001 (default), One step change of this value of SCAL[5:0]
results in 3% scaling up/down against the pulse amplitude.
Do the followings step by step, the desired waveform can be programmed, based on the selected waveform template:
(1).Select the UI by UI[1:0] bits (TCF3, 08H)
(2).Specify the sample address in the selected UI by SAMP [3:0] bits
(TCF3, 08H)
(3).Write sample data to WDAT[6:0] bits (TCF4, 09H). It contains the
data to be stored in the RAM, addressed by the selected UI and the
corresponding sample address.
(4).Set the RW bit (TCF3, 08H) to ‘0’ to implement writing data to RAM,
or to ‘1’ to implement read data from RAM
(5).Implement the Read from RAM/Write to RAM by setting the DONE
bit (TCF3, 08H)
Table-3 Transmit Waveform Value For E1 120 ohm
Repeat the above steps until all the sample data are written to or read
from the internal RAM.
(6).Write the scaling data to SCAL[5:0] bits (TCF2, 07H) to scale the
amplitude of the waveform based on the selected standard pulse
amplitude
When more than one UI is used to compose the pulse template, the overlap of two consecutive pulses could make the pulse amplitude overflow
(exceed the maximum limitation) if the pulse amplitude is not set properly.
This overflow is captured by DAC_OV_IS bit (INTS1, 1AH), and, if enabled
by the DAC_OV_IM bit (INTM1, 15H), an interrupt will be generated.
Sample
UI 1
UI 2
UI 3
UI 4
1
0000000
0000000
0000000
0000000
2
0000000
0000000
0000000
0000000
3
0000000
0000000
0000000
0000000
4
0001111
0000000
0000000
0000000
5
0111100
0000000
0000000
0000000
6
0111100
0000000
0000000
0000000
7
0111100
0000000
0000000
0000000
8
0111100
0000000
0000000
0000000
9
0111100
0000000
0000000
0000000
10
0111100
0000000
0000000
0000000
11
0111100
0000000
0000000
0000000
12
0111100
0000000
0000000
0000000
13
0000000
0000000
0000000
0000000
14
0000000
0000000
0000000
0000000
15
0000000
0000000
0000000
0000000
16
0000000
0000000
0000000
0000000
SCAL[5:0] = 100001 (default), One step change of this value of SCAL[5:0]
results in 3% scaling up/down against the pulse amplitude.
Functional Description
16
December 9, 2005
IDT82V2051E
3.2.4
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
pin will be set to select the specific internal impedance. Refer to 5 Hardware
Control Pin Summary for details.
TRANSMIT PATH LINE INTERFACE
The transmit line interface consists of TTIP pin and TRING pin. The
impedance matching can be realized by the internal impedance matching
circuit or the external impedance matching circuit. If T_TERM[2] is set to
‘0’, the internal impedance matching circuit will be selected. In this case,
the T_TERM[1:0] bits (TERM, 03H) can be set to choose 75 Ω or 120 Ω
internal impedance of TTIP/TRING. If T_TERM[2] is set to ‘1’, the internal
impedance matching circuit will be disabled. In this case, the external
impedance matching circuit will be used to realize the impedance matching.
Figure-6 shows the appropriate external components to connect with the
cable. Table-4 is the list of the recommended impedance matching for
transmitter.
The TTIP/TRING pins can also be turned into high impedance by setting
the THZ bit (TCF1, 06H) to ‘1’. In this state, the internal transmit circuits are
still active.
In hardware control mode, TTIP/TRING can be turned into high impedance by pulling THZ pin to high. Refer to 5 Hardware Control Pin Summary
for details.
Besides, in the following cases, both TTIP/TRING pins will also become
high impedance:
•
Loss of MCLK;
•
Loss of TCLK (exceptions: Remote Loopback; Transmit internal
pattern by MCLK);
•
Transmit path power down;
•
After software reset; pin reset and power on.
In hardware control mode, TERM pin can be used to select impedance
matching for both receiver and transmitter. If TERM pin is low, external
impedance network will be used for impedance matching. If TERM pin is
high, internal impedance will be used for impedance matching and PULS
Table-4 Impedance Matching for Transmitter
Cable Configuration
Internal Termination
External Termination
T_TERM[2:0]
PULS[3:0]
RT
T_TERM[2:0]
PULS[3:0]
RT
E1 / 75 Ω
000
0000
0Ω
1XX
0001
9.4 Ω
E1 / 120 Ω
001
0001
Note: The precision of the resistors should be better than ± 1%
3.2.5
In hardware control mode, the transmit path can be powered down by
pulling both PATT1 and PATT0 pins to high. Refer to 5 Hardware Control
Pin Summary for details.
TRANSMIT PATH POWER DOWN
The transmit path can be powered down by setting the T_OFF bit (TCF0,
05H) to ‘1’. In this case, the TTIP/TRING pins are turned into high impedance.
Functional Description
17
December 9, 2005
IDT82V2051E
3.3
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
RECEIVE PATH
is set to ‘0’, the internal impedance matching circuit will be selected. In this
case, the R_TERM[1:0] bits (TERM, 03H) can be set to choose 75 Ω or 120
Ω internal impedance of RTIP/RRING. If R_TERM[2] is set to ‘1’, the internal impedance matching circuit will be disabled. In this case, the external
impedance matching circuit will be used to realize the impedance matching.
Figure-6 shows the appropriate external components to connect with the
cable. Table-5 is the list of the recommended impedance matching for
receiver.
The receive path consists of Receive Internal Termination, Monitor
Gain, Amplitude/Wave Shape Detector, Digital Tuning Controller, Adaptive
Equalizer, Data Slicer, CDR (Clock & Data Recovery), Optional Jitter
Attenuator, Decoder and LOS/AIS Detector. Refer to Figure-5.
3.3.1
RECEIVE INTERNAL TERMINATION
The impedance matching can be realized by the internal impedance
matching circuit or the external impedance matching circuit. If R_TERM[2]
LOS/AIS
Detector
RTIP
Receive
Internal
termination
RRING
Adaptive Equalizer/
Monitor Gain
Data Slicer
LOS
RCLK
Clock
and Data
Recovery
Jitter
Attenuator
Decoder
RDP
RDN
Figure-5 Receive Monitor Gain Adaptive Equalizer
Table-5 Impedance Matching for Receiver
Cable Configuration
Internal Termination
External Termination
R_TERM[2:0]
RR
R_TERM[2:0]
E1/75 Ω
000
120 Ω
1XX
E1/120 Ω
001
•
RX Line
RR
4
2:1
• •
RTIP
D6
D5
R T4
•·
VDDT
D4
RRING
VDDT
D2
RT
68µF 1
•·
TTIP
D1
•
GNDA
3.3 V
VDDT
Cp
4
3.3 V
VDDA
0.1µF
D3
TX Line
•·
VDDA
•
B
D7
IDT82V2051E
A
75 Ω
120 Ω
VDDA
D8
1:1
• •
RR
68µF 1
0.1µF
•·
TRING
GNDT
•
Note: 1. Common decoupling capacitor, one per chip
2. Cp 0-560 (pF)
3. D1 - D8, Motorola - MBR0540T1; International Rectifier - 11DQ04 or 10BQ060
4. RT/ RR: refer toTable-4 and Table-5 respecivley for RT and RR values
Figure-6 Transmit/Receive Line Circuit
Functional Description
18
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
In hardware control mode, TERM and PULS pins can be used to select
impedance matching for both receiver and transmitter. If TERM pin is low,
external impedance network will be used for impedance matching. If TERM
pin is high, internal impedance will be used for impedance matching and
PULS pins can be set to select the specific internal impedance. Refer to 5
Hardware Control Pin Summary for details.
3.3.2
DSX cross connect
point
RTIP
monitor
gain=0dB
RRING
R
LINE MONITOR
normal receive mode
The non-intrusive monitoring on channels located in other chips can be
performed by tapping the monitored channel through a high impedance
bridging circuit. Refer to Figure-7 and Figure-9.
RTIP
monitor gain
=22/26/32dB
After a high resistance bridging circuit, the signal arriving at the RTIP/
RRING is dramatically attenuated. To compensate this attenuation, the
Monitor Gain can be used to boost the signal by 22 dB, 26 dB and 32 dB,
selected by MG[1:0] bits (RCF2, 0CH). For normal operation, the Monitor
Gain should be set to 0 dB.
RRING
monitor mode
Figure-7 Monitoring Receive Line in Another Chip
In hardware control mode, MONT pin can be used to set the Monitor
Gain. When MONT pin is low, the Monitor Gain is 0 dB. When MONT pin
is high, the Monitor Gain is 26 dB. Refer to 5 Hardware Control Pin Summary
for details.
DSX cross connect
point
TTIP
Note that LOS indication is not supported if the device is operated in Line
Monitor Mode
TRING
R
normal transmit mode
RTIP
monitor gain
monitor gain
=22/26/32dB
RRING
monitor mode
Figure-8 Monitor Transmit Line in Another Chip
Functional Description
19
December 9, 2005
IDT82V2051E
3.3.3
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
3.3.4
ADAPTIVE EQUALIZER
RECEIVE SENSITIVITY
The Receive Sensitivity is -10 dB. With the Adaptive Equalizer enabled,
the receive sensitivity will be -20 dB.
The Adaptive Equalizer can be enabled to increase the receive sensitivity and to allow programming of the LOS level up to -24 dB. See3.5 Los
And AIS Detection. It can be enabled or disabled by setting EQ_ON bit to
‘1’ or ‘0’ (RCF1, 0BH).
In Hardware mode, the Adaptive Equalizer can not be enabled and the
receive sensitivity is fixed at -10 dB. Refer to 5 Hardware Control Pin Summary for details.
3.3.5
DATA SLICER
The Data Slicer is used to generate a standard amplitude mark or a
space according to the amplitude of the input signals. The threshold can
be 40%, 50%, 60% or 70%, as selected by the SLICE[1:0] bits (RCF2, 0CH).
The output of the Data Slicer is forwarded to the CDR (Clock & Data Recovery) unit or to the RDP/RDN pins directly if the CDR is disabled.
3.3.6
CDR (CLOCK & DATA RECOVERY)
The CDR is used to recover the clock and data from the received signal.
The recovered clock tracks the jitter in the data output from the Data Slicer
and keeps the phase relationship between data and clock during the
absence of the incoming pulse. The CDR can also be by-passed in the Dual
Rail mode. When CDR is by-passed, the data from the Data Slicer is output
to the RDP/RDN pins directly.
3.3.7
DECODER
The R_MD[1:0] bits (RCF0, 0AH) are used to select the AMI decoder
or HDB3 decoder.
When the chip is configured by hardware, the operation mode of receive
and transmit path can be selected by setting RXTXM1 and RXTXM0 pins.
Refer to 5 Hardware Control Pin Summary for details.
Functional Description
20
December 9, 2005
IDT82V2051E
3.3.8
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
3.4
RECEIVE PATH SYSTEM INTERFACE
The receive path system interface consists of RCLK pin, RD/RDP pin
and RDN pin. The RCLK outputs a recovered 2.048 MHz clock. The
received data is updated on the RD/RDP and RDN pins on the active edge
of RCLK. The active edge of RCLK can be selected by the RCLK_SEL bit
(RCF0, 0AH). And the active level of the data on RD/RDP and RDN can be
selected by the RD_INV bit (RCF0, 0AH).
There is one Jitter Attenuator in the IDT82V2051E. The Jitter Attenuator
can be deployed in the transmit path or the receive path, and can also be
disabled. This is selected by the JACF[1:0] bits (JACF, 04H).
In hardware control mode, Jitter Attenuator position, bandwidth and the
depth of FIFO can be selected by JA[1:0] pins. Refer to 5 Hardware Control
Pin Summary for details.
In hardware control mode, only the active edge of RCLK can be
selected. If RCLKE is set to high, the falling edge will be chosen as the active
edge of RCLK. If RCLKE is set to low, the rising edge will be chosen as the
active edge of RCLK. The active level of the data on RD/RDP and RDN is
the same as that in software control mode.
3.4.1
JITTER ATTENUATION FUNCTION DESCRIPTON
The Jitter Attenuator is composed of a FIFO and a DPLL, as shown in
Figure-9. The FIFO is used as a pool to buffer the jittered input data, then
the data is clocked out of the FIFO by a de-jittered clock. The depth of the
FIFO can be 32 bits, 64 bits or 128 bits, as selected by the JADP[1:0] bits
(JACF, 04H). In hardware control mode, the depth of FIFO can be selected
by JA[1:0] pins. Refer to 5 Hardware Control Pin Summary for details. Consequently, the constant delay of the Jitter Attenuator will be 16 bits, 32 bits
or 64 bits. Deeper FIFO can tolerate larger jitter, but at the cost of increasing
data latency time.
The received data can be output to the system side in two different ways:
Single Rail or Dual Rail, as selected by R_MD bit [1] (RCF0, 0AH). In Single
Rail mode, only RD pin is used to output data and the RDN/CV pin is used
to report the received errors. In Dual Rail Mode, both RDP pin and RDN pin
are used for outputting data.
In the receive Dual Rail mode, the CDR unit can be by-passed by setting
R_MD[1:0] to ‘11’ (binary). In this situation, the output data from the Data
Slicer will be output to the RDP/RDN pins directly, and the RCLK outputs
the exclusive OR (XOR) of the RDP and RDN. This is called receiver slicer
mode. In this case, the transmit path is still operating in Dual Rail mode.
3.3.9
JITTER ATTENUATOR
Jittered Data
RECEIVE PATH POWER DOWN
The receive path can be powered down by setting R_OFF bit (RCF0,
0AH) to ‘1’. In this case, the RCLK, RD/RDP, RDN and LOS will be logic low.
In hardware control mode, receiver power down can be selected by pulling RPD pin to high. Refer to 5 Hardware Control Pin Summary for more
details.
Jittered Clock
RD/RDP
FIFO
32/64/128
W
De-jittered Data
RDN
R
DPLL
De-jittered Clock
RCLK
MCLK
Figure-9 Jitter Attenuator
The Corner Frequency of the DPLL can be 0.9 Hz or 6.8 Hz, as selected
by the JABW bit (JACF, 04H). The lower the Corner Frequency is, the longer
time is needed to achieve synchronization.
When the incoming data moves faster than the outgoing data, the FIFO
will overflow. This overflow is captured by the JAOV_IS bit (INTS1, 1AH).
If the incoming data moves slower than the outgoing data, the FIFO will
underflow. This underflow is captured by the JAUD_IS bit (INTS1, 1AH). For
some applications that are sensitive to data corruption, the JA limit mode
can be enabled by setting JA_LIMIT bit (JACF, 04H) to ‘1’. In the JA limit
mode, the speed of the outgoing data will be adjusted automatically when
the FIFO is close to its full or emptiness. The criteria of starting speed adjustment are shown in Table-6. The JA limit mode can reduce the possibility of
FIFO overflow and underflow, but the quality of jitter attenuation is deteriorated.
Functional Description
21
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-6 Criteria of Starting Speed Adjustment
FIFO Depth
Criteria for Adjusting Data Outgoing Speed
32 Bits
2 bits close to its full or emptiness
3.4.2
64 Bits
3 bits close to its full or emptiness
128 Bits
4 bits close to its full or emptiness
LOS=1
The performance of the Jitter Attenuator in the IDT82V2051E meets the
ITU-T I.431, G.703, G.736-739, G.823, G.824, ETSI 300011 and ETSI
TBR12/13 specifications. Details of the Jitter Attenuator performance is
shown in Table-47 Jitter Tolerance and Table-48 Jitter Attenuator Characteristics.
3.5
LOS AND AIS DETECTION
3.5.1
LOS DETECTION
signal level<Q
signal level>P
density=OK
JITTER ATTENUATOR PERFORMANCE
(observing windows= M)
(observing windows= N)
LOS=0
Figure-10 LOS Declare and Clear
• LOS detect level threshold
With the Adaptive Equalizer off, the amplitude threshold Q is fixed on
800 mVpp, while P=Q+200 mVpp (200 mVpp is the LOS level detect hysteresis).
The Loss of Signal Detector monitors the amplitude of the incoming signal level and pulse density of the received signal on RTIP and RRING.
• LOS declare (LOS=1)
A LOS is detected when the incoming signal has “no transitions”, i.e.,
when the signal level is less than Q dB below nominal for N consecutive
pulse intervals. Here N is defined by LAC bit (MAINT0, 0DH). LOS will be
declared by pulling LOS pin to high (LOS=1) and LOS interrupt will be generated if it is not masked.
With the Adaptive Equalizer on, the value of Q can be selected by
LOS[4:0] bit (RCF1, 0BH), while P=Q+4 dB (4 dB is the LOS level detect
hysteresis). Refer to Table-20 TCF1: Transmitter Configuration Register 1
for LOS[4:0] bit values available.
When the chip is configured by hardware, the Adaptive Equalizer can
not be enabled and Programmable LOS levels are not available (pin 29 has
to be set to ‘0’).
Note that LOS indication is not supported if the device is operated in Line
Monitor Mode. Refer to 3.3.2 Line Monitor.
• Criteria for declare and clear of a LOS detect
The detection supports G.775 and ETSI 300233/I.431. The criteria can
be selected by LAC bit (MAINT0, 0DH).
• LOS clear (LOS=0)
The LOS is cleared when the incoming signal has “transitions”, i.e.,
when the signal level is greater than P dB below nominal and has an average pulse density of at least 12.5% for M consecutive pulse intervals, starting with the receipt of a pulse. Here M is defined by LAC bit (MAINT0, 0DH).
LOS status is cleared by pulling LOS pin to low.
Table-7 and Table-8 summarize LOS declare and clear criteria for both
with and without the Adaptive Equalizer enabled.
• All Ones output during LOS
On the system side, the RDP/RDN will reflect the input pulse “transition”
at the RTIP/RRING side and output recovered clock (but the quality of the
output clock can not be guaranteed when the input level is lower than the
maximum receive sensitivity) when AISE bit (MAINT0, 0DH) is 0; or output
All Ones as AIS when AISE bit (MAINT0, 0DH) is 1. In this case, RCLK output is replaced by MCLK.
On the line side, the TTIP/TRING will output All Ones as AIS when ATAO
bit (MAINT0, 0DH) is 1. The All Ones pattern uses MCLK as the reference
clock.
LOS indicator is always active for all kinds of loopback modes.
Table-7 LOS Declare and Clear Criteria, Adaptive Equalizer Disabled
Control bit (LAC)
LOS declare threshold
LOS clear threshold
0 = G.775
Level < 800 mVpp; N=32 bits
Level > 1 Vpp; M=32 bits; 12.5% mark density; <16 consecutive zeroes
1 = I.431/ETSI
Level < 800 mVpp; N=2048 bits
Level > 1 Vpp; M=32 bits; 12.5% mark density; <16 consecutive zeroes
Functional Description
22
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-8 LOS Declare and Clear Criteria, Adaptive Equalizer Enabled
Control bit
LAC
0
G.775
1
3.5.2
LOS declare threshold
LOS[4:0]
I.431/ETSI
LOS clear threshold
Note
Q (dB)
00000
…
00010
-4
…
-8
00011
…
01010
01011 - 11111
-10
…
-24
Reserved
00000
-4
00001
…
01010
01011 - 11111
-6
…
-24
Reserved
Level < Q
N=32 bits
Level > Q+ 4 dB
M=32 bits
12.5% mark density
<16 consecutive zeroes
G.775 Level detect range is -9 to -35 dB.
Level < Q
N=2048 bits
Level > Q+ 4 dB
M=32 bits
12.5% mark density
<16 consecutive zeroes
I.431 Level detect range is -6 to -20 dB.
AIS detection comply with the ITU G.775 or the ETSI 300233, as selected
by the LAC bit (MAINT0, 0DH). Table-9 summarizes different criteria for AIS
detection Declaring/Clearing.
AIS DETECTION
The Alarm Indication Signal can be detected by the IDT82V2051E when
the Clock & Data Recovery unit is enabled. The status of AIS detection is
reflected in the AIS_S bit (STAT0, 17H). The criteria for declaring/clearing
Table-9 AIS Condition
ITU G.775 (LAC bit is set to ‘0’ by default)
ETSI 300233 (LAC bit is set to ‘1’)
AIS detected Less than 3 zeros contained in each of two consecutive 512-bit streams are received Less than 3 zeros contained in a 512-bit stream are received
AIS cleared 3 or more zeros contained in each of two consecutive 512-bit streams are received
Functional Description
23
3 or more zeros contained in a 512-bit stream are received
December 9, 2005
IDT82V2051E
3.6
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
TRANSMIT AND DETECT INTERNAL PATTERNS
PRBS data can be inverted through setting the PRBS_INV bit (MAINT0,
0DH).
The internal patterns (All Ones, All Zeros and PRBS pattern) will be generated and detected by IDT82V2051E. TCLK is used as the reference clock
by default. MCLK can also be used as the reference clock by setting the
PATT_CLK bit (MAINT0, 0DH) to ‘1’.
Any change of PRBS_S bit will be captured by PRBS_IS bit (INTS0,
19H). The PRBS_IES bit (INTES, 16H) can be used to determine whether
the ‘0’ to ‘1’ change of PRBS_S bit will be captured by the PRBS_IS bit or
any changes of PRBS_S bit will be captured by the PRBS_IS bit. When the
PRBS_IS bit is ‘1’, an interrupt will be generated if the PRBS_IM bit (INTM0,
14H) is set to ‘1’.
If the PATT_CLK bit (MAINT0, 0DH) is set to ‘0’ and the PATT[1:0] bits
(MAINT0, 0DH) are set to ‘00’, the transmit path will operate in normal mode.
When the chip is configured by hardware, the transmit path will operate
in normal mode by setting PATT[1:0] pins to ‘00’. Refer to 5 Hardware Control Pin Summary for details.
3.6.1
The received PRBS logic errors can be counted in a 16-bit counter if the
ERR_SEL [1:0] bits (MAINT6, 13H) are set to ‘00’. Refer to 3.8 Error Detection/Counting And Insertion for the operation of the error counter.
TRANSMIT ALL ONES
3.7
In transmit direction, the All Ones data can be inserted into the data
stream when the PATT[1:0] bits (MAINT0, 0DH) are set to ‘01’. The transmit
data stream is output from TTIP/TRING. In this case, either TCLK or MCLK
can be used as the transmit clock, as selected by the PATT_CLK bit
(MAINT0, 0DH).
To facilitate testing and diagnosis, the IDT82V2051E provides three different loopback configurations: Analog Loopback, Digital Loopback and
Remote Loopback.
3.7.1
In hardware control mode, the All Ones data can be inserted into the data
stream in transmit direction by setting PATT[1:0] pins to ‘01’. Refer to 5
Hardware Control Pin Summary for details.
3.6.2
TRANSMIT ALL ZEROS
3.7.2
DIGITAL LOOPBACK
When the DLP bit (MAINT1, 0EH) is set to ‘1’, the chip is configured in
Digital Loopback mode. In this mode, the transmit signals are looped back
to the jitter attenuator (if enabled) and decoder in receive path, then output
from RCLK, RD, RDP/RDN. At the same time, the transmit signals are still
output to TTIP/TRING in transmit direction. Figure-12 shows the process.
PRBS GENERATION AND DETECTION
A PRBS will be generated in the transmit direction and detected in the
receive direction by IDT82V2051E. The PRBS is 215-1, with maximum zero
restrictions according to ITU-T O.151.
When the PATT[1:0] bits (MAINT0, 0DH) are set to ‘10’, the PRBS pattern will be inserted into the transmit data stream with the MSB first. The
PRBS pattern will be transmitted directly or invertedly.
Both Analog Loopback mode and Digital Loopback mode allow the
sending of the internal patterns (All Ones, All Zeros, PRBS, etc.) which will
overwrite the transmit signals. In this case, either TCLK or MCLK can be
used as the reference clock for internal patterns transmission.
In hardware control mode, the PRBS data will be generated in the transmit direction and inserted into the transmit data stream by setting PATT[1:0]
pins to ‘10’. Refer to 5 Hardware Control Pin Summary for details.
In hardware control mode, Digital Loopback can be selected by setting
LP[1:0] pins to ‘10’.
The PRBS in the received data stream will be monitored. If the PRBS
has reached synchronization status, the PRBS_S bit (STAT0, 17H) will be
set to ‘1’, even in the presence of a logic error rate less than or equal to 101. The criteria for setting/clearing the PRBS_S bit are shown in Table-10.
3.7.3
REMOTE LOOPBACK
When the RLP bit (MAINT1, 0EH) is set to ‘1’, the chip is configured in
Remote Loopback mode. In this mode, the recovered clock and data output
from Clock and Data Recovery on the receive path is looped back to the
jitter attenuator (if enabled) and Waveform Shaper in transmit path. Figure13 shows the process.
Table-10 Criteria for Setting/Clearing the PRBS_S Bit
PRBS Detection 6 or less than 6 bit errors detected in a 64 bits hopping win-
In hardware control mode, Remote Loopback can be selected by setting
LP[1:0] pins to ‘11’.
dow.
PRBS Missing
ANALOG LOOPBACK
When the ALP bit (MAINT1, 0EH) is set to ‘1’, the chip is configured in
Analog Loopback mode. In this mode, the transmit signals are looped back
to the Receiver Internal Termination in the receive path then output from
RCLK, RD, RDP/RDN. At the same time, the transmit signals are still output
to TTIP/TRING in transmit direction. The all-ones pattern can be generated
during analog loopback. Figure-11 shows the process.
If the PATT_CLK bit (MAINT0, 0DH) is set to ‘1’, the All Zeros will be
inserted into the transmit data stream when the PATT[1:0] bits (MAINT0,
0DH) are set to ‘00’.
3.6.3
LOOPBACK
More than 6 bit errors detected in a 64 bits hopping window.
Functional Description
24
December 9, 2005
IDT82V2051E
LOS
RCLK
RD/RDP
CV/RDN
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
LOS/AIS
Detection
HDB3/AMI
Decoder
Clock and
Data
Recovery
Jitter
Attenuator
Data
Slicer
Adaptive
Equalizer
Receiver
Internal
Termination
RTIP
RRING
Analog
Loopback
TCLK
TD/TDP
TDN
HDB3/AMI
Encoder
Jitter
Attenuator
Transmitter
Internal
Termination
Line
Driver
Waveform
Shaper
TTIP
TRING
Figure-11 Analog Loopback
LOS
RCLK
RD/RDP
CV/RDN
LOS/AIS
Detection
HDB3/AMI
Decoder
Clock and
Data
Recovery
Jitter
Attenuator
Data
Slicer
Adaptive
Equalizer
Receiver
Internal
Termination
RTIP
RRING
Digital
Loopback
TCLK
TD/TDP
TDN
HDB3/AMI
Encoder
Jitter
Attenuator
Waveform
Shaper
Line
Driver
Transmitter
Internal
Termination
TTIP
TRING
Figure-12 Digital Loopback
Functional Description
25
December 9, 2005
IDT82V2051E
LOS
RCLK
RD/RDP
CV/RDN
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
LOS/AIS
Detection
HDB3/AMI
Decoder
Jitter
Attenuator
Clock and
Data
Recovery
Data
Slicer
Adaptive
Equalizer
Receiver
Internal
Termination
RTIP
RRING
Remote
Loopback
TCLK
TD/TDP
TDN
HDB3/AMI
Encoder
Jitter
Attenuator
Waveform
Shaper
Line
Driver
Transmitter
Internal
Termination
TTIP
TRING
Figure-13 Remote Loopback
Functional Description
26
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
3.8
ERROR DETECTION/COUNTING AND INSERTION
3.8.1
DEFINITION OF LINE CODING ERROR
•
The following line encoding errors can be detected and counted by the
IDT82V2051E:
•
Received Bipolar Violation (BPV) Error: In AMI coding, when two
consecutive pulses of the same polarity are received, a BPV error
is declared.
•
HDB3 Code Violation (CV) Error: In HDB3 coding, a CV error is
declared when two consecutive BPV errors are detected, and the
pulses that have the same polarity as the previous pulse are not the
HDB3 zero substitution pulses.
Excess Zero (EXZ) Error: There are two standards defining the
EXZ errors: ANSI and FCC. The EXZ_DEF bit (MAINT6, 13H)
chooses which standard will be adopted by the chip to judge the
EXZ error. Table-11 shows definition of EXZ. In hardware control
mode, only ANSI standard is adopted.
Table-11 EXZ Definition
EXZ Definition
3.8.2
ANSI
FCC
AMI
More than 15 consecutive 0s are detected
More than 80 consecutive 0s are detected
HDB3
More than 3 consecutive 0s are detected
More than 3 consecutive 0s are detected
ERROR DETECTION AND COUNTING
Auto Report Mode
(CNT_MD=1)
Which type of the receiving errors (Received CV/BPV errors, excess
zero errors and PRBS logic errors) will be counted is determined by
ERR_SEL[1:0] bits (MAINT6, 13H). Only one type of receiving error can be
counted at a time except that when the ERR_SEL[1:0] bits are set to ‘11’,
both CV/BPV and EXZ errors will be detected and counted.
counting
The selected type of receiving errors is counted in an internal 16-bit Error
Counter. Once an error is detected, an error interrupt which is indicated by
corresponding bit in (INTS1, 1AH) will be generated if it is not masked. This
Error Counter can be operated in two modes: Auto Report Mode and Manual Report Mode, as selected by the CNT_MD bit (MAINT6, 13H). In Single
Rail mode, once BPV or CV errors are detected, the CV pin will be driven
to high for one RCLK period.
One-Second Timer expired?
CNT0, CNT1
counter
0
Y
data in counter
Bit TMOV_IS is set to '1'
• Auto Report Mode
In Auto Report Mode, the internal counter starts to count the received
errors when the CNT_MD bit (MAINT6, 13H) is set to ‘1’. A one-second timer
is used to set the counting period. The received errors are counted within
one second. If the one-second timer expires, the value in the internal
counter will be transferred to (CNT0, 1BH) and (CNT1, 1CH), then the internal counter will be reset and start to count received errors for the next second. The errors occurred during the transfer will be accumulated to the next
round. The expiration of the one-second timer will set TMOV_IS bit (INTS1,
1AH) to ‘1’, and will generate an interrupt if the TIMER_IM bit (INTM1, 15H)
is set to ‘0’. The TMOV_IS bit (INTS1, 1AH) will be cleared after the interrupt
register is read. The content in the (CNT0, 1BH) and (CNT1, 1CH) should
be read within the next second. If the counter overflows, a counter overflow
interrupt which is indicated by CNT_OV_IS bit (INTS1, 1AH) will be generated if it is not masked by CNT_IM bit (INTM1, 15H).
Functional Description
next second
repeats the
same process
N
read the data in CNT0, CNT1 within
the next second
Bit TMOV_IS is cleared after
the interrupt register is read
Figure-14 Auto Report Mode
27
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
• Manual Report Mode
In Manual Report Mode, the internal Error Counter starts to count the
received errors when the CNT_MD bit (MAINT6, 13H) is set to ‘0’. When
there is a ‘0’ to ‘1’ transition on the CNT_TRF bit (MAINT6, 13H), the data
in the counter will be transferred to (CNT0, 1BH) and (CNT1, 1CH), then
the counter will be reset. The errors occurred during the transfer will be
accumulated to the next round. If the counter overflows, a counter overflow
interrupt indicated by CNT_OV_IS bit (INTS1, 1AH) will be generated if it
is not masked by CNT_IM bit (INTM1, 15H).
3.8.3
Only when three consecutive ‘1’s are detected in the transmit data
stream, will a ‘0’ to ‘1’ transition on the BPV_INS bit (MAINT6, 13H) generate
a bipolar violation pulse, and the polarity of the second ‘1’ in the series will
be inverted.
A ‘0’ to ‘1’ transition on the EER_INS bit (MAINT6, 13H) will generate a
logic error during the PRBS transmission.
3.9
counting
N
A '0' to '1' transition
on CNT_TRF?
CNT0, CNT1
counter
counter 0
data in
LINE DRIVER FAILURE MONITORING
The transmit driver failure monitor can be enabled or disabled by setting
DFM_OFF bit (TCF1, 06H). If the transmit driver failure monitor is enabled,
the transmit driver failure will be captured by DF_S bit (STAT0, 17H). The
transition of the DF_S bit is reflected by DF_IS bit (INTS0, 19H), and, if
enabled by DF_IM bit (INTM0, 14H), will generate an interrupt. When there
is a short circuit on the TTIP/TRING port, the output current will be limited
to 100 mA (typical), and an interrupt will be generated.
Manual Report mode
(CNT_MD=0)
Y
BIPOLAR VIOLATION AND PRBS ERROR INSERTION
In hardware control mode, the transmit driver failure monitor is always
enabled.
next round
repeat the
same process
Read the data in CNT0,
CNT1 within next round1
Reset CNT_TRF for the
next '0' to '1' transition
Figure-15 Manual Report Mode
Note: It is recommended that users should do the followings within next round of
error counting: Read the data in CNT0 and CNT1; Reset CNT_TRF bit for
the next ‘0’ to ‘1’ transition on this bit.
Functional Description
28
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
3.10 MCLK AND TCLK
3.10.2 TRANSMIT CLOCK (TCLK)
3.10.1 MASTER CLOCK (MCLK)
TCLK is used to sample the transmit data on TD/TDP and TDN. The
active edge of TCLK can be selected by the TCLK_SEL bit (TCF0, 05H).
During Transmit All Ones or PRBS patterns, either TCLK or MCLK can be
used as the reference clock. This is selected by the PATT_CLK bit
(MAINT0, 0DH).
MCLK is an independent, free-running reference clock. MCLK is 2.048
MHz. This reference clock is used to generate several internal reference
signals:
•
Timing reference for the integrated clock recovery unit.
•
Timing reference for the integrated digital jitter attenuator.
•
Timing reference for microcontroller interface.
•
Generation of RCLK signal during a loss of signal condition if AIS is
enabled.
•
Reference clock during Transmit All Ones, All Zeros and PRBS pattern if it is selected as the reference clock. For ATAO and AIS,
MCLK is always used as the reference clock.
•
Reference clock during Transmit All Ones (TAO) condition or sending PRBS in hardware control mode.
But for Automatic Transmit All Ones and AIS, only MCLK is used as the
reference clock and the PATT_CLK bit is ignored. In Automatic Transmit
All Ones condition, the ATAO bit (MAINT0, 0DH) is set to ‘1’. In AIS condition, the AISE bit (MAINT0, 0DH) is set to ‘1’.
If TCLK has been missing for more than 70 MCLK cycles, TCLK_LOS
bit (STAT0, 17H) will be set, and the TTIP/TRING will become high impedance if the chip is not used for remote loopback or is not using MCLK to transmit internal patterns (TAOS, All Zeros and PRBS). When TCLK is detected
again, TCLK_LOS bit (STAT0, 17H) will be cleared. The reference frequency to detect a TCLK loss is derived from MCLK.
Figure-16 shows the chip operation status in different conditions of
MCLK and TCLK. The missing of MCLK will set the TTIP/TRING to high
impedance state.
Clocked
MCLK=H/L?
yes
L/H
transmitter high impedance
TCLK status?
generate transmit clock loss
interrupt if not masked in
software control mode;
clocked
normal operation
transmitter high impedance
Figure-16 TCLK Operation Flowchart
Functional Description
29
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
3.11 MICROCONTROLLER INTERFACES
3.11.1 PARALLEL MICROCONTROLLER INTERFACE
The microcontroller interface provides access to read and write the registers in the device. The chip supports serial microcontroller interface and
two kinds of parallel microcontroller interface: Motorola multiplexed mode
and Intel multiplexed mode. Different microcontroller interfaces can be
selected by setting MODE[1:0] pins to different values. Refer to MODE1
and MODE0 in pin description and Microcontroller Interface Timing Characteristics for details.
The interface is compatible with Motorola or Intel microcontroller. When
MODE[1:0] pins are set to ‘10’, Parallel-Multiplexed-Motorola interface is
selected. When MODE[1:0] pins are set to ‘11’, Parallel-Multiplexed-Intel
Interface is selected.
3.11.2 SERIAL MICROCONTROLLER INTERFACE
When MODE[1:0] pins are set to ‘01’, Serial Interface is selected. In this
mode, the registers are programmed through a 16-bit word which contains
an 8-bit address/command byte (5 address bits A0~A4 and bit R/W) and
an 8-bit data byte (D0~D7). When bit R/W is ‘1’, data is read out from pin
SDO. When bit R/W is ‘0’, data is written into SDI pin. Refer to Figure-17.
CS
SCLK
SDI
A0
A1
A2
A3
A4 R/W
-
-
D0
address/command byte
D2
D3
D4
D5
D6
D7
D6
D7
input data byte (R/W=0)
D0
SDO
D1
D1
D2
D3
D4
D5
output data byte (R/W=1)
remains high impedance
Figure-17 Serial Microcontroller Interface Function Timing
3.12 INTERRUPT HANDLING
There are totally twelve kinds of events that could be the interrupt
source:
(1).LOS Detected
(2).AIS Detected
(3).Driver Failure Detected
(4).TCLK Loss
(5).Synchronization Status of PRBS
(6).PRBS Error Detected
(7).Code Violation Received
(8).Excessive Zeros Received
(9).JA FIFO Overflow/Underflow
(10).One-Second Timer Expired
(11).Error Counter Overflow
(12).Arbitrary Waveform Generator Overflow
All kinds of interrupt of the IDT82V2051E are indicated by the INT pin.
When the INT_PIN[0] bit (GCF, 02H) is ‘0’, the INT pin is open drain active
low, with a 10 KΩ external pull-up resistor. When the INT_PIN[1:0] bits
(GCF, 02H) are ‘01’, the INT pin is push-pull active low; when the
INT_PIN[1:0] bits are ‘10’, the INT pin is push-pull active high.
An active level on the INT pin represents an interrupt of the
IDT82V2051E.
The interrupt event is captured by the corresponding bit in the Interrupt
Status Register (INTS0, 19H) or (INTS1, 1AH). Every kind of interrupt can
be enabled/disabled individually by the corresponding bit in the register
(INTM0, 14H) or (INTM1, 15H). Some event is reflected by the corresponding bit in the Status Register (STAT0, 17H) or (STAT1, 18H), and the Interrupt Trigger Edge Selection Register can be used to determine how the
Status Register sets the Interrupt Status Register.
Table-12 is a summary of all kinds of interrupt and the associated Status
bit, Interrupt Status bit, Interrupt Trigger Edge Selection bit and Interrupt
Mask bit.
After the Interrupt Status Register (INTS0, 19H) or (INTS1, 1AH) is read,
the INT pin become inactive.
Functional Description
30
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-12 Interrupt Event
Interrupt Event
Status bit
(STAT0, STAT1)
Interrupt Status bit
(INTS0, INTS1)
Interrupt Edge Selection bit
(INTES)
Interrupt Mask bit
(INTM0, INTM1)
LOS Detected
LOS_S
LOS_IS
LOS_IES
LOS_IM
AIS Detected
AIS_S
AIS_IS
AIS_IES
AIS_IM
Driver Failure Detected
DF_S
DF_IS
DF_IES
DF_IM
TCLK Loss
TCLK_LOS
TCLK_LOS_IS
TCLK_IES
TCLK_IM
Synchronization Status of PRBS
PRBS_S
PRBS_IS
PRBS_IES
PRBS_IM
PRBS Error
ERR_IS
ERR_IM
Code Violation Received
CV_IS
CV_IM
Excessive Zeros Received
EXZ_IS
EXZ_IM
JA FIFO Overflow
JAOV_IS
JAOV_IM
JA FIFO Underflow
JAUD_IS
JAUD_IM
One-Second Timer Expired
TMOV_IS
TIMER_IM
Error Counter Overflow
CNT_OV_IS
CNT_IM
Arbitrary Waveform Generator Overflow
DAC_OV_IS
DAC_OV_IM
3.13 5V TOLERANT I/O PINS
•
All digital input pins will tolerate 5.0 ± 10% volts and are compatible with
TTL logic.
3.14 RESET OPERATION
•
After reset, all drivers output are in high impedance state, all the internal
flip-flops are reset, and all the registers are initialized to default values.
The chip can be reset in two ways:
Software Reset: Writing to the RST register (01H) will reset the chip
in 1 us.
Functional Description
Hardware Reset: Asserting the RST pin low for a minimum of 100
ns will reset the chip.
During Hardware Reset, the device requires an active clock on
MCLK.
3.15 POWER SUPPLY
This chip uses a single 3.3 V power supply.
31
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
4
PROGRAMMING INFORMATION
4.1
REGISTER LIST AND MAP
4.2
The registers banks include control registers, status registers and
counter registers.
RESERVED REGISTERS
When writing to registers with reserved bit locations, the default state
must be written to the reserved bits to ensure proper device operation.
Table-13 Register List and Map
Address (hex)
Register
R/W
Map
b7
b6
b5
b4
b3
b2
b1
b0
ID7
ID6
ID5
ID4
ID3
ID2
ID1
ID0
-
-
-
-
-
-
INT_PIN1
INT_PIN0
Control Registers
00
ID
R
01
RST
W
02
GCF
R/W
03
TERM
R/W
-
-
T_TERM2
T_TERM1
T_TERM0
R_TERM2
R_TERM1
R_TERM0
04
JACF
R/W
-
-
JA_LIMIT
JACF1
JACF0
JADP1
JADP0
JABW
R/W
-
-
-
T_OFF
TD_INV
TCLK_SEL
T_MD1
T_MD0
Transmit Path Control Registers
05
TCF0
06
TCF1
R/W
-
-
DFM_OFF
THZ
PULS3
PULS2
PULS1
PULS0
07
TCF2
R/W
-
-
SCAL5
SCAL4
SCAL3
SCAL2
SCAL1
SCAL0
08
TCF3
R/W
DONE
RW
UI1
UI0
SAMP3
SAMP2
SAMP1
SAMP0
09
TCF4
R/W
-
WDAT6
WDAT5
WDAT4
WDAT3
WDAT2
WDAT1
WDAT0
R/W
-
-
-
R_OFF
RD_INV
RCLK_SEL
R_MD1
R_MD0
Receive Path Control Registers
0A
RCF0
0B
RCF1
R/W
-
EQ_ON
-
LOS4
LOS3
LOS2
LOS1
LOS0
0C
RCF2
R/W
-
-
SLICE1
SLICE0
-
-
MG1
MG0
Network Diagnostics Control Registers
0D
MAINT0
R/W
-
PATT1
PATT0
PATT_CLK
PRBS_INV
LAC
AISE
ATAO
0E
MAINT1
R/W
-
-
-
-
-
RLP
ALP
DLP
1F-12
MAINT2MAINT5
R/W
-
-
-
-
-
-
-
-
13
MAINT6
R/W
-
BPV_INS
ERR_INS
EXZ_DEF
ERR_SEL1
ERR_SEL0
CNT_MD
CNT_TRF
Interrupt Control Registers
14
INTM0
R/W
-
-
-
PRBS_IM
TCLK_IM
DF_IM
AIS_IM
LOS_IM
15
INTM1
R/W
DAC_OV_IM
JAOV_IM
JAUD_IM
ERR_IM
EXZ_IM
CV_IM
TIMER_IM
CNT_IM
16
INTES
R/W
-
-
-
PRBS_IES
TCLK_IES
DF_IES
AIS_IES
LOS_IES
17
STAT0
R
-
-
-
PRBS_S
TCLK_LOS
DF_S
AIS_S
LOS_S
18
STAT1
R
-
-
RLP_S
-
-
-
-
-
Line Status Register
Interrupt Status Register
19
INTS0
R
-
-
-
PRBS_IS
TCLK_LOS_IS
DF_IS
AIS_IS
LOS_IS
1A
INTS1
R
DAC_OV_IS
JAOV_IS
JAUD_IS
ERR_IS
EXZ_IS
CV_IS
TMOV_IS
CNT_OV_IS
1B
CNT0
R
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
1C
CNT1
R
Bit15
Bit14
Bit13
Bit12
Bit11
Bit10
Bit9
Bit8
Counter Registers
Programming Information
32
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
4.3
REGISTER DESCRIPTION
4.3.1
CONTROL REGISTERS
Table-14 ID: Device Revision Register
(R, Address = 00H)
Symbol
Bit
Default
ID[7:0]
7-0
00H
Description
Current silicon chip ID.
Table-15 RST: Reset Register
(W, Address = 01H)
Symbol
Bit
Default
Description
RST[7:0]
7-0
00H
Software reset. A write operation on this register will reset all internal registers to their default values, and the status
of all ports are set to the default status. The content in this register can not be changed. After reset, all drivers output
are in high impedance state.
Table-16 GCF: Global Configuration Register
(R/W, Address = 02H)
Symbol
Bit
Default
-
7-2
000000
INT_PIN[1:0]
1-0
00
Description
Reserved.
Interrupt pin control
= x0: Open drain, active low (with an external pull-up resistor)
= 01: Push-pull, active low
= 11: Push-pull, active high
Table-17 TERM: Transmit and Receive Termination Configuration Register
(R/W, Address = 03H)
Symbol
Bit
Default
-
7-6
00
Reserved.
T_TERM[2:0]
5-3
000
These bits select the internal termination for transmit line impedance matching.
= 000: Internal 75 Ω impedance matching
= 001: Internal 120 Ω impedance matching
= 1xx: Selects external impedance matching resistors (see Table-4).
R_TERM[2:0]
2-0
000
These bits select the internal termination for receive line impedance matching.
= 000: Internal 75 Ω impedance matching
= 001: Internal 120 Ω impedance matching
= 1xx: Selects external impedance matching resistors (see Table-5).
Programming Information
Description
33
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-18 JACF: Jitter Attenuation Configuration Register
(R/W, Address = 04H)
Symbol
Bit
Default
-
7-6
00
Reserved.
JA_LIMIT
5
1
= 0: Normal mode
= 1: JA limit mode
JACF[1:0]
4-3
00
Jitter attenuation configuration
= 00/10: JA not used
= 01: JA in transmit path
= 11: JA in receive path
JADP[1:0]
2-1
00
Jitter attenuation depth select
= 00: 128 bits
= 01: 64 bits
= 1x: 32 bits
JABW
0
0
Jitter transfer function bandwidth select
= 0: 6.8 Hz
= 1: 0.9 Hz
Programming Information
Description
34
December 9, 2005
IDT82V2051E
4.3.2
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
TRANSMIT PATH CONTROL REGISTERS
Table-19 TCF0: Transmitter Configuration Register 0
(R/W, Address = 05H)
Symbol
Bit
Default
-
7-5
000
Description
T_OFF
4
0
Transmitter power down enable
= 0: Transmitter power up
= 1: Transmitter power down (line driver high impedance)
TD_INV
3
0
Transmit data invert
= 0: Data on TD or TDP/TDN is active high
= 1: Data on TD or TDP/TDN is active low
TCLK_SEL
2
0
Transmit clock edge select
= 0: Data on TDP/TDN is sampled on the falling edge of TCLK
= 1: Data on TDP/TDN is sampled on the rising edge of TCLK
T_MD[1:0]
0-1
00
Transmitter operation mode control
T_MD[1:0] select different stages of the transmit data path
= 00: Enable HDB3 encoder and waveform shaper blocks. Input on pin TD is single rail NRZ data
= 01: Enable AMI encoder and waveform shaper blocks. Input on pin TD is single rail NRZ data
= 1x: Encoder is bypassed, dual rail NRZ transmit data input on pin TDP/TDN
Reserved.
Table-20 TCF1: Transmitter Configuration Register 1
(R/W, Address = 06H)
Symbol
Bit
Default
Description
-
7-6
00
Reserved. This bit should be ‘0’ for normal operation.
DFM_OFF
5
0
Transmit driver failure monitor disable
= 0: DFM is enabled
= 1: DFM is disabled
THZ
4
1
Transmit line driver high impedance enable
= 0: Normal state
= 1: Transmit line driver high impedance enable (other transmit path still work normally)
PULS[3:0]
3-0
0000
These bits select the transmit template:
TCLK
Cable impedance
Allowable Cable loss
00001
2.048 MHz
75 Ω
0-24 dB
0001
2.048 MHz
120 Ω
0-24 dB
0010 - 1011
Reserved
11XX
User programmable waveform setting
1. In internal impedance matching mode, for E1/75 Ω cable impedance, the PULS[3:0] bits (TCF1, 06H) should be set to ‘0000’. In external impedance matching mode, for E1/75 Ω cable
impedance, the PULS[3:0] bits should be set to ‘0001’.
Table-21 TCF2: Transmitter Configuration Register 2
(R/W, Address = 07H)
Symbol
Bit
Default
-
7-6
00
SCAL[5:0]
5-0
100001
Description
Reserved.
SCAL specifies a scaling factor to be applied to the amplitude of the user-programmable arbitrary pulses which is
to be transmitted if needed. The default value of SCAL[5:0] is ‘100001’. Refer to 3.2.3.2 User-Programmable Arbitrary Waveform.
= 100001: Default value for 75 Ω and 120 Ω. One step change of this value results in 3% scaling up/down against
the pulse amplitude.
Programming Information
35
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-22 TCF3: Transmitter Configuration Register 3
(R/W, Address = 08H)
Symbol
Bit
Default
DONE
7
0
After ‘1’ is written to this bit, a read or write operation is implemented.
Description
RW
6
0
This bit selects read or write operation
= 0: Write to RAM
= 1: Read from RAM
UI[1:0]
5-4
00
These bits specify the unit interval address. There are totally 4 unit intervals.
= 00: UI address is 0 (The most left UI)
= 01: UI address is 1
= 10: UI address is 2
= 11: UI address is 3
SAMP[3:0]
3-0
0000
These bits specify the sample address. Each UI has totally 16 samples.
= 0000: Sample address is 0 (The most left sample)
= 0001: Sample address is 1
= 0010: Sample address is 2
……
= 1110: Sample address is 14
= 1111: Sample address is 15
Table-23 TCF4: Transmitter Configuration Register 4
(R/W, Address = 09H)
Symbol
Bit
Default
-
7
0
WDAT[6:0]
6-0
0000000
Programming Information
Description
Reserved
In Indirect Write operation, the WDAT[6:0] will be loaded to the pulse template RAM, specifying the amplitude of
the Sample.
After an Indirect Read operation, the amplitude data of the Sample in the pulse template RAM will be output to the
WDAT[6:0].
36
December 9, 2005
IDT82V2051E
4.3.3
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
RECEIVE PATH CONTROL REGISTERS
Table-24 RCF0: Receiver Configuration Register 0
(R/W, Address = 0AH)
Symbol
Bit
Default
-
7-5
000
Description
R_OFF
4
0
Receiver power down enable
= 0: Receiver power up
= 1: Receiver power down
RD_INV
3
0
Receive data invert
= 0: Data on RD or RDP/RDN is active high
= 1: Data on RD or RDP/RDN is active low
RCLK_SEL
2
0
Receive clock edge select (this bit is ignored in slicer mode)
= 0: Data on RD or RDP/RDN is updated on the rising edge of RCLK
= 1: Data on RD or RDP/RDN is updated on the falling edge of RCLK
R_MD[1:0]
1-0
00
Receive path decoding selection
= 00: Receive data is HDB3 decoded and output on RD pin with single rail NRZ format
= 01: Receive data is AMI decoded and output on RD pin with single rail NRZ format
= 10: Decoder is bypassed, re-timed dual rail data with NRZ format output on RDP/RDN (dual rail mode with clock
recovery)
= 11: CDR and decoder are bypassed, slicer data with RZ format output on RDP/RDN (slicer mode)
Reserved
Table-25 RCF1: Receiver Configuration Register 1
(R/W, Address= 0BH)
Symbol
Bit
Default
Description
-
7
0
Reserved
EQ_ON
6
0
= 0: Receive equalizer off
= 1: Receive equalizer on (LOS programming enabled)
Reserved.
-
5
0
LOS[4:0]
4:0
10101
LOS Clear Level (dB)
00000
0
<-4
00001
>-2
<-6
00010
>-4
<-8
00011
>-6
<-10
00100
>-8
<-12
00101
>-10
<-14
00110
>-12
<-16
00111
>-14
<-18
01000
>-16
<-20
01001
>-18
<-22
>-20
<-24
01010
01011 - 11111
Programming Information
LOS Declare Level (dB)
Reserved
37
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-26 RCF2: Receiver Configuration Register 2
(R/W, Address = 0CH)
Symbol
Bit
Default
-
7-6
00
Reserved.
SLICE[1:0]
5-4
01
Receive slicer threshold
= 00: The receive slicer generates a mark if the voltage on RTIP/RRING exceeds 40% of the peak amplitude.
= 01: The receive slicer generates a mark if the voltage on RTIP/RRING exceeds 50% of the peak amplitude.
= 10: The receive slicer generates a mark if the voltage on RTIP/RRING exceeds 60% of the peak amplitude.
= 11: The receive slicer generates a mark if the voltage on RTIP/RRING exceeds 70% of the peak amplitude.
-
3-2
10
Reserved
MG[1:0]
1-0
00
Monitor gain setting: these bits select the internal linear gain boost
= 00: 0 dB
= 01: 22 dB
= 10: 26 dB
= 11: 32 dB
Programming Information
Description
38
December 9, 2005
IDT82V2051E
4.3.4
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
NETWORK DIAGNOSTICS CONTROL REGISTERS
Table-27 MAINT0: Maintenance Function Control Register 0
(R/W, Address = 0DH)
Symbol
Bit
Default
-
7
00
Reserved.
Description
PATT[1:0]
6-5
00
These bits select the internal pattern and insert it into transmit data stream.
= 00: Normal operation (PATT_CLK = 0) / insert all zeros (PATT_CLK = 1)
= 01: Insert All Ones
= 10: Insert PRBS (E1: 215-1)
= 11: Reserved
PATT_CLK
4
0
Selects reference clock for transmitting internal pattern
= 0: Uses TCLK as the reference clock
= 1: Uses MCLK as the reference clock
PRBS_INV
3
0
Inverts PRBS
= 0: The PRBS data is not inverted
= 1: The PRBS data is inverted before transmission and detection
LAC
2
0
LOS/AIS criterion is selected as below:
= 0: G.775
= 1: ETSI 300233& I.431
AISE
1
0
AIS enable during LOS
= 0: AIS insertion on RDP/RDN/RCLK is disabled during LOS
= 1: AIS insertion on RDP/RDN/RCLK is enabled during LOS
ATAO
0
0
Automatically Transmit All Ones (enabled only when PATT[1:0] = 00)
= 0: Disabled
= 1: Automatically Transmit All Ones pattern at TTIP/TRING during LOS
Table-28 MAINT1: Maintenance Function Control Register 1
(R/W, Address= 0EH)
Symbol
Bit
Default
Description
-
7-3
00000
RLP
2
0
Remote loopback enable
= 0: Disables remote loopback (normal transmit and receive operation)
= 1: Enables remote loopback
Reserved
ALP
1
0
Analog loopback enable
= 0: Disables analog loopback (normal transmit and receive operation)
= 1: Enables analog loopback
DLP
0
0
Digital loopback enable
= 0: Disables digital loopback (normal transmit and receive operation)
= 1: Enables digital loopback
Table-29 MAINT6: Maintenance Function Control Register 6
(R/W, Address = 13H)
Symbol
Bit
Default
-
7
0
Reserved.
BPV_INS
6
0
BPV error insertion
A ‘0’ to ‘1’ transition on this bit will cause a single bipolar violation error to be inserted into the transmit data stream.
This bit must be cleared and set again for a subsequent error to be inserted.
ERR_INS
5
0
PRBS logic error insertion
A ‘0’ to ‘1’ transition on this bit will cause a single PRBS logic error to be inserted into the transmit PRBS data stream.
This bit must be cleared and set again for a subsequent error to be inserted.
Programming Information
Description
39
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-29 MAINT6: Maintenance Function Control Register 6 (Continued)
(R/W, Address = 13H)
Symbol
Bit
Default
EXZ_DEF
5
0
EXZ definition select
= 0: ANSI
= 1: FCC
ERR_SEL
3-2
00
These bits choose which type of error will be counted
= 00: The PRBS logic error is counted by a 16-bit error counter.
= 01: The EXZ error is counted by a 16-bit error counter.
= 10: The Received CV (BPV) error is counted by a 16-bit error counter.
= 11: Both CV (BPV) and EXZ errors are counted by a 16-bit error counter.
CNT_MD
1
0
Counter operation mode select
= 0: Manual Report mode
= 1: Auto Report mode
CNT_TRF
0
0
= 0: Clear this bit for the next ‘0’ to ‘1’ transition on this bit.
= 1: Error counting result is transferred to CNT0 and CNT1 and the error counter is reset.
Programming Information
Description
40
December 9, 2005
IDT82V2051E
4.3.5
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
INTERRUPT CONTROL REGISTERS
Table-30 INTM0: Interrupt Mask Register 0
(R/W, Address = 14H)
Symbol
Bit
Default
-
7-5
111
Description
PRBS_IM
4
1
PRBS synchronic signal detect interrupt mask
= 0: PRBS synchronic signal detect interrupt enabled
= 1: PRBS synchronic signal detect interrupt masked
TCLK_IM
3
1
TCLK loss detect interrupt mask
= 0: TCLK loss detect interrupt enabled
= 1: TCLK loss detect interrupt masked
DF_IM
2
1
Driver Failure interrupt mask
= 0: Driver Failure interrupt enabled
= 1: Driver Failure interrupt masked
AIS_IM
1
1
Alarm Indication Signal interrupt mask
= 0: Alarm Indication Signal interrupt enabled
= 1: Alarm Indication Signal interrupt masked
LOS_IM
0
1
Loss Of Signal interrupt mask
= 0: Loss Of Signal interrupt enabled
= 1: Loss Of Signal interrupt masked
Reserved
Table-31 INTM1: Interrupt Masked Register 1
(R/W, Address = 15H)
Symbol
Bit
Default
DAC_OV_IM
7
1
DAC arithmetic overflow interrupt mask
= 0: DAC arithmetic overflow interrupt enabled
= 1: DAC arithmetic overflow interrupt masked
JAOV_IM
6
1
JA overflow interrupt mask
= 0: JA overflow interrupt enabled
= 1: JA overflow interrupt masked
JAUD_IM
5
1
JA underflow interrupt mask
= 0: JA underflow interrupt enabled
= 1: JA underflow interrupt masked
ERR_IM
4
1
PRBS logic error detect interrupt mask
= 0: PRBS logic error detect interrupt enabled
= 1: PRBS logic error detect interrupt masked
EXZ_IM
3
1
Receive excess zeros interrupt mask
= 0: Receive excess zeros interrupt enabled
= 1: Receive excess zeros interrupt masked
CV_IM
2
1
Receive error interrupt mask
= 0: Receive error interrupt enabled
= 1: Receive error interrupt masked
TIMER_IM
1
1
One-Second Timer expiration interrupt mask
= 0: One-Second Timer expiration interrupt enabled
= 1: One-Second Timer expiration interrupt masked
CNT_IM
0
1
Counter overflow interrupt mask
= 0: Counter overflow interrupt enabled
= 1: Counter overflow interrupt masked
Programming Information
Description
41
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-32 INTES: Interrupt Trigger Edge Select Register
(R/W, Address = 16H)
Symbol
Bit
Default
-
7-5
000
PRBS_IES
4
0
This bit determines the PRBS synchronization status interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the PRBS_S bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the PRBS_S bit in STAT0
status register
TCLK_IES
3
0
This bit determines the TCLK Loss interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the TCLK_LOS bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the TCLK_LOS bit in STAT0
status register
DF_IES
2
0
This bit determines the Driver Failure interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the DF_S bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the DF_S bit in STAT0 status
register
AIS_IES
1
0
This bit determines the AIS interrupt event.
= 0: Interrupt event is generated as a ‘0’ to ‘1’ transition of the AIS_S bit in STAT0 status register
= 1: Interrupt event is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the AIS_S bit in STAT0 status
register
LOS_IES
0
0
This bit determines the LOS interrupt event.
= 0: Interrupt is generated as a ‘0’ to ‘1’ transition of the LOS_S bit in STAT0 status register
= 1: Interrupt is generated as either a ‘0’ to ‘1’ transition or a ‘1’ to ‘0’ transition of the LOS_S bit in STAT0 status
register
Programming Information
Description
Reserved
42
December 9, 2005
IDT82V2051E
4.3.6
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
LINE STATUS REGISTERS
Table-33 STAT0: Line Status Register 0 (real time status monitor)
(R, Address = 17H)
Symbol
Bit
Default
-
7-5
000
PRBS_S
4
0
Description
Reserved
Synchronous status indication of PRBS (real time)
= 0: 215-1 PRBS is not detected
= 1: 215-1 PRBS is detected
Note:
If PRBS_IM=0:
A ‘0’ to ‘1’ transition on this bit causes a synchronous status detected interrupt if PRBS _IES bit is ‘0’.
Any changes of this bit causes an interrupt if PRBS_IES bit is set to ‘1’.
TCLK_LOS
3
0
TCLK loss indication
= 0: Normal
= 1: TCLK pin has not toggled for more than 70 MCLK cycles.
Note:
If TCLK_IM=0:
A ‘0’ to ‘1’ transition on this bit causes an interrupt if TCLK _IES bit is ‘0’.
Any changes of this bit causes an interrupt if TCLK_IES bit is set to ‘1’.
DF_S
2
0
Line driver status indication
= 0: Normal operation
= 1: Line driver short circuit is detected.
Note:
If DF_IM=0
A ‘0’ to ‘1’ transition on this bit causes an interrupt if DF _IES bit is ‘0’.
Any changes of this bit causes an interrupt if DF_IES bit is set to ‘1’.
AIS_S
1
0
Alarm Indication Signal status detection
= 0: No AIS signal is detected in the receive path
= 1: AIS signal is detected in the receive path
Note:
If AIS_IM=0
A ‘0’ to ‘1’ transition on this bit causes an interrupt if AIS _IES bit is ‘0’.
Any changes of this bit causes an interrupt if AIS_IES bit is set to ‘1’.
LOS_S
0
0
Loss Of Signal status detection
= 0: Loss of signal on RTIP/RRING is not detected.
= 1: Loss of signal on RTIP/RRING is detected.
Note:
If LOS_IM=0
A ‘0’ to ‘1’ transition on this bit causes an interrupt if LOS _IES bit is ‘0’.
Any changes of this bit causes an interrupt if LOS_IES bit is set to ‘1’.
Programming Information
43
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-34 STAT1: Line Status Register 1 (real time status monitor)
(R, Address = 18H)
Symbol
Bit
Default
-
7-6
00
Reserved.
RLP_S
5
0
Indicating the status of Remote Loopback
= 0: The remote loopback is inactive.
= 1: The remote loopback is active (closed).
-
4-0
00000
Programming Information
Description
Reserved
44
December 9, 2005
IDT82V2051E
4.3.7
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
INTERRUPT STATUS REGISTERS
Table-35 INTS0: Interrupt Status Register 0
(R, Address = 19H) (this register is reset and relevant interrupt request is cleared after a read)
Symbol
Bit
Default
-
7-5
000
Description
PRBS_IS
4
0
This bit indicates the occurrence of the interrupt event generated by the PRBS synchronization status.
= 0: No PRBS synchronization status interrupt event occurred
= 1: PRBS synchronization status interrupt event occurred
TCLK_LOS_IS
3
0
This bit indicates the occurrence of the interrupt event generated by the TCLK loss detection.
= 0: No TCLK loss interrupt event.
= 1: TCLK loss interrupt event occurred.
DF_IS
2
0
This bit indicates the occurrence of the interrupt event generated by the Driver Failure.
= 0: No Driver Failure interrupt event occurred
= 1: Driver Failure interrupt event occurred
AIS_IS
1
0
This bit indicates the occurrence of the AIS (Alarm Indication Signal) interrupt event.
= 0: No AIS interrupt event occurred
= 1: AIS interrupt event occurred
LOS_IS
0
0
This bit indicates the occurrence of the LOS (Loss of signal) interrupt event.
= 0: No LOS interrupt event occurred
= 1: LOS interrupt event occurred
Reserved
Table-36 INTS1: Interrupt Status Register 1
(R, Address = 1AH) (this register is reset and the relevant interrupt request is cleared after a read)
Symbol
Bit
Default
Description
DAC_OV_IS
7
0
This bit indicates the occurrence of the pulse amplitude overflow of Arbitrary Waveform Generator interrupt event.
= 0: No pulse amplitude overflow of Arbitrary Waveform Generator interrupt event occurred
= 1: The pulse amplitude overflow of Arbitrary Waveform Generator interrupt event occurred
JAOV_IS
6
0
This bit indicates the occurrence of the Jitter Attenuator Overflow interrupt event.
= 0: No JA Overflow interrupt event occurred
= 1: JA Overflow interrupt event occurred
JAUD_IS
5
0
This bit indicates the occurrence of the Jitter Attenuator Underflow interrupt event.
= 0: No JA Underflow interrupt event occurred
= 1: JA Underflow interrupt event occurred
ERR_IS
4
0
This bit indicates the occurrence of the interrupt event generated by the detected PRBS logic error.
= 0: No PRBS logic error interrupt event occurred
= 1: PRBS logic error interrupt event occurred
EXZ_IS
3
0
This bit indicates the occurrence of the Excessive Zeros interrupt event.
= 0: No Excessive Zeros interrupt event occurred
= 1: EXZ interrupt event occurred
CV_IS
2
0
This bit indicates the occurrence of the Code Violation interrupt event.
= 0: No Code Violation interrupt event occurred
= 1: Code Violation interrupt event occurred
TMOV_IS
1
0
This bit indicates the occurrence of the One-Second Timer Expiration interrupt event.
= 0: No One-Second Timer Expiration interrupt event occurred
= 1: One-Second Timer Expiration interrupt event occurred
CNT_OV_IS
0
0
This bit indicates the occurrence of the Counter Overflow interrupt event.
= 0: No Counter Overflow interrupt event occurred
= 1: Counter Overflow interrupt event occurred
Programming Information
45
December 9, 2005
IDT82V2051E
4.3.8
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
COUNTER REGISTERS
Table-37 CNT0: Error Counter L-byte Register 0
(R, Address = 1BH)
Symbol
Bit
Default
CNT_L[7:0]
7-0
00H
Description
This register contains the lower eight bits of the 16-bit error counter. CNT_L[0] is the LSB.
Table-38 CNT1: Error Counter H-byte Register 1
(R, Address = 1CH)
Symbol
Bit
Default
CNT_H[7:0]
7-0
00H
Programming Information
Description
This register contains the upper eight bits of the 16-bit error counter. CNT_H[7] is the MSB.
46
December 9, 2005
IDT82V2051E
5
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
HARDWARE CONTROL PIN SUMMARY
Table-39 Hardware Control Pin Summary
Pin No.
TQFP
Symbol
17
16
MODE1
MODE0
23
TERM
21
20
RXTXM1
RXTXM0
30
PULS
Description
MODE[1:0]: Operation mode of control interface select
00= Hardware interface
01= Serial interface
10= Parallel – multiplexed – Motorola Interface
11= Parallel – multiplexed – Intel Interface
TERM: Termination interface select
This pin selects internal or external impedance matching for both receiver and transmitter
0= ternary interface with external impedance matching network.
1= ternary interface with internal impedance matching network
RXTXM[1:0]: Receive and transmit path operation mode select
00= single rail with HDB3 coding
01= single rail with AMI coding
10= dual rail interface with CDR enable
11= slicer mode
PULS: This pin is used to select the following functions:
•
Transmit pulse template
•
Internal termination impedance (75 Ω / 120Ω)
PULS
TCLK
Cable impedance (internal matching impedance)
Cable loss
0
2.048 MHz
75Ω
0-24 dB
1
2.048 MHz
120Ω
0-24 dB
28
RPD
RPD: Receiver power down control
0= Normal operation
1= receiver power down
27
26
PATT1
PATT0
15
14
JA1
JA0
22
MONT
25
24
LP1
LP0
LP[1:0]: Loopback mode select
00= no loopback
01= analog loopback
10= digital loopback
11= remote loopback
13
THZ
THZ: Transmitter Driver High Impedance Enable
This signal enables or disables transmitter driver. A low level on this pin enables the driver while a high level on this pin places the
driver in high impedance state.
11
RCLKE
PATT[1:0]: Transmit test pattern select
In hardware control mode, these pins select the transmit pattern
00 = normal
01= All Ones
10= PRBS
11= transmitter power down
JA[1:0]: Jitter attenuation position, bandwidth and the depth of FIFO select
00= JA is disabled
01= JA in receiver, broad bandwidth, FIFO=64 bits
10= JA in receiver, narrow bandwidth, FIFO=128 bits
11= JA in transmitter, narrow bandwidth, FIFO=128 bits
MONT: Receive monitor n gain select
0= 0 dB
1= up to 26 dB
RCLKE: the active edge of RCLK select when hardware control mode is used
0= select the rising edge as active edge of RCLK
1= select the falling edge as active edge of RCLK
Hardware Control Pin Summary
47
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-39 Hardware Control Pin Summary (Continued)
Pin No.
TQFP
Symbol
29
31
32
33
-
Description
In Hardware mode, this pin has to be tied to GND.
Hardware Control Pin Summary
48
December 9, 2005
IDT82V2051E
6
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
TEST SPECIFICATIONS
Table-40 Absolute Maximum Rating
Symbol
Parameter
Min
Max
Unit
VDDA, VDDD
Core Power Supply
-0.5
4.6
V
VDDIO
I/O Power Supply
-0.5
4.6
V
VDDT
Transmit Power Supply
Vin
-0.5
4.6
V
Input Voltage, Any Digital Pin
GND-0.5
5.5
V
Input Voltage, Any RTIP and RRING pin1
GND-0.5
VDDA+0.5
V
ESD Voltage, any pin
2000 2
V
500 3
V
Transient latch-up current, any pin
Iin
Input current, any digital pin
-10
4
DC Input current, any analog pin
4
100
mA
10
mA
±100
mA
Pd
Maximum power dissipation in package
1.41
W
Tc
Case Temperature
120
°C
Ts
Storage Temperature
+150
°C
-65
CAUTION:
Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied. Exposure to absolute maximum rating conditions
for extended periods may affect device reliability.
1.Reference to ground
2.Human body model
3.Charge device model
4.Constant input current
Table-41 Recommended Operation Conditions
Min
Typ
Max
VDDA, VDDD
Symbol
Core Power Supply
Parameter
3.13
3.3
3.47
Unit
V
VDDIO
I/O Power Supply
3.13
3.3
3.47
V
VDDT
Transmitter Power Supply
3.13
3.3
3.47
V
TA
Ambient operating temperature
-40
25
85
°C
50% ones density data
100% ones density data
-
52
64
58
70
mA
50% ones density data
100% ones density data
-
58
70
64
76
mA
75 Ω load
Total current dissipation1,2,3
120 Ω Load
1.Power consumption includes power consumption on device and load. Digital levels are 10% of the supply rails and digital outputs driving a 50 pF capacitive load.
2.Maximum power consumption over the full operating temperature and power supply voltage range.
3.In short haul mode, if internal impedance matching is chosen, 75 Ω power dissipation values are measured with template PULS[3:0] = 0000; 120 Ω power dissipation values are measured
with template PULS[3:0] = 0001.
Test Specifications
49
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-42 Power Consumption
Symbol
Parameter
Min
Typ
Max1,2
Unit
50% ones density data:
100% ones density data:
-
172
212
243
mW
50% ones density data:
100% ones density data:
-
192
243
264
mW
3.3 V, 75 Ω Load
3.3 V, 120 Ω Load
1.Maximum power and current consumption over the full operating temperature and power supply voltage range.
2.Power consumption includes power absorbed by line load and external transmitter components.
Table-43 DC Characteristics
Symbol
Parameter
Min
Typ
Max
Unit
-
-
0.8
V
2.0
-
-
V
VIL
Input Low Level Voltage
VIH
Input High Voltage
VOL
Output Low level Voltage (Iout=1.6mA)
-
-
0.4
V
VOH
Output High level Voltage (Iout=400µA)
2.4
-
VDDIO
V
VMA
Analog Input Quiescent Voltage (RTIP, RRING
pin while floating)
IZL
High Impedance Leakage Current
1.5
V
-10
10
µA
Ci
Input capacitance
15
pF
Co
Output load capacitance
50
pF
Co
Output load capacitance (bus pins)
100
pF
Table-44 Receiver Electrical Characteristics
Symbol
Parameter
Min
Typ
Receiver sensitivity
Adaptive Equalizer Disabled:
Adaptive Equalizer Enabled:
Analog LOS level
Adaptive Equalizer Disabled:
Adaptive Equalizer Enabled:
Test Specifications
Max
Unit
-10
-20
dB
800
-4
-24
50
mVp-p
dB
Test conditions
A LOS level is programmable with Adaptive
Equalizer enabled. Not available in Hardware
mode.
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-44 Receiver Electrical Characteristics (Continued)
Symbol
Parameter
Min
Allowable consecutive zeros before LOS
G.775:
I.431/ETSI300233:
LOS reset
Typ
12.5
RPD
Test conditions
% ones
0.05
Input Jitter Tolerance
1 Hz – 20 Hz
20 Hz – 2.4 KHz
18 KHz – 100 KHz
37
5
2
Receiver Differential Input Impedance
20
Input termination resistor tolerance
RRX
Unit
32
2048
Receive Intrinsic Jitter
20 Hz - 100 kHz
ZDM
Max
G.775, ETSI 300 233
U.I.
JA enabled
U.I.
U.I.
U.I.
G.823, with 6 dB cable attenuation
KΩ
Internal mode
dB
dB
dB
G.703 Internal termination
U.I.
U.I.
JA disabled
±1%
Receive Return Loss
51 KHz – 102 KHz
102 KHz – 2.048 MHz
2.048 MHz – 3.072 MHz
20
20
20
Receive path delay
Single rail
Dual rail
7
2
Table-45 Transmitter Electrical Characteristics
Symbol
Vo-p
Vo-s
Parameter
Output pulse amplitudes
75 Ω load
120 Ω load
Zero (space) level
75 Ω load
120 Ω load
Min
Typ
Max
Unit
2.14
2.7
2.37
3.0
2.60
3.3
V
V
0.237
0.3
V
V
-0.237
-0.3
Transmit amplitude variation with supply
-1
Difference between pulse sequences for 17 consecutive pulses (T1.102)
Tpw
RTX
244
%
mV
256
ns
Output Pulse Width at 50% of nominal amplitude
232
Ratio of the amplitudes of Positive and Negative Pulses at the center of the pulse interval
(G.703)
0.95
1.05
Ratio of the width of Positive and Negative Pulses at the center of the pulse interval (G.703)
0.95
1.05
Transmit Return Loss (G.703)
20
15
12
51 KHz – 102 KHz
102 KHz - 2.048 MHz
2.048 MHz – 3.072 MHz
JTXp-p
Intrinsic Transmit Jitter (TCLK is jitter free)
Td
Transmit path delay (JA is disabled)
20 Hz – 100 KHz
Isc
+1
200
dB
dB
dB
0.050
U.I.
Single rail
Dual rail
8.5
4.5
U.I.
U.I.
Line short circuit current (measured on the TTIP/TRING pins)
100
mAp
Test Specifications
51
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-46 Transmitter and Receiver Timing Characteristics
Symbol
Parameter
Min
MCLK frequency
Typ
Max
2.048
Unit
MHz
MCLK tolerance
-100
100
ppm
MCLK duty cycle
30
70
%
Transmit path
TCLK frequency
2.048
MHz
TCLK tolerance
-50
+50
ppm
TCLK Duty Cycle
10
90
%
t1
Transmit Data Setup Time
40
ns
t2
Transmit Data Hold Time
40
ns
Delay time of THZ low to driver high impedance
10
Delay time of TCLK low to driver high impedance
us
75
U.I.
± 80
ppm
Receive path
Clock recovery capture range 1
t4
RCLK duty cycle 2
40
50
60
%
RCLK pulse width 2
457
488
519
ns
t5
RCLK pulse width low time
203
244
285
ns
t6
RCLK pulse width high time
203
244
285
ns
20
ns
Rise/fall time 3
t7
Receive Data Setup Time
200
244
ns
t8
Receive Data Hold Time
200
244
ns
1.Relative to nominal frequency, MCLK= ± 100 ppm
2.RCLK duty cycle widths will vary depending on extent of received pulse jitter displacement. Maximum and minimum RCLK duty cycles are for worst case jitter conditions (0.2 UI displacement
for E1 per ITU G.823).
3.For all digital outputs. C load = 15 pF
TCLK
t1
t2
TD/TDP
TDN
Figure-18 Transmit System Interface Timing
Test Specifications
52
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
t4
RCLK
t6
t5
t7
t8
RDP/RD
(RCLK_SEL = 0 software mode)
(RCLKE = 0 hardware mode)
RDN/CV
t7
t8
RDP/RD
(RCLK_SEL = 1 software mode)
(RCLKE = 1 hardware mode)
RDN/CV
Figure-19 Receive System Interface Timing
Table-47 Jitter Tolerance
Jitter Tolerance
1 Hz
20 Hz – 2.4 KHz
18 KHz – 100 KHz
Test Specifications
Min
Typ
37
1.5
0.2
Max
Unit
U.I.
U.I.
U.I.
53
Standard
G.823
Cable attenuation is 6 dB
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Figure-20 E1 Jitter Tolerance Performance
Table-48 Jitter Attenuator Characteristics
Parameter
Min
Typ
Max
Unit
Jitter Transfer Function Corner (-3 dB) Frequency
32/64/128 bits FIFO
JABW = 0:
JABW = 1:
6.8
0.9
Hz
Hz
Jitter Attenuator
(G.736)
-0.5
-0.5
+19.5
+19.5
@ 3 Hz
@ 40 Hz
@ 400 Hz
@ 100 kHz
dB
Jitter Attenuator Latency Delay
32 bits FIFO:
64 bits FIFO:
128 bits FIFO:
16
32
64
U.I.
U.I.
U.I.
Input jitter tolerance before FIFO overflow or underflow
32 bits FIFO:
64 bits FIFO:
128 bits FIFO:
28
58
120
U.I.
U.I.
U.I.
Test Specifications
54
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Figure-21 E1 Jitter Transfer Performance
Test Specifications
55
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
7
MICROCONTROLLER INTERFACE TIMING CHARACTERISTICS
7.1
SERIAL INTERFACE TIMING
Table-49 Serial Interface Timing Characteristics
Symbol
Parameter
Min
Typ
Max
Unit
t1
SCLK High Time
100
ns
t2
SCLK Low Time
100
ns
t3
Active CS to SCLK Setup Time
5
ns
t4
Last SCLK Hold Time to Inactive CS Time
41
ns
t5
CS Idle Time
41
ns
t6
SDI to SCLK Setup Time
0
ns
82
t7
SCLK to SDI Hold Time
t10
SCLK to SDO Valid Delay Time
95
ns
t11
Inactive CS to SDO High Impedance Hold Time
90
ns
Comments
ns
CS
t3
t1
t4
t2
t5
SCLK
t6
SDI
t7
t7
LSB
MSB
LSB
Figure-22 Serial Interface Write Timing
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
SCLK
t4
t10
CS
SDO
0
1
2
3
4
5
6
13
14
15
t11
7
Figure-23 Serial Interface Read Timing with SCLKE=1
1
2
3
4
5
6
7
8
9
10
11
12
16
SCLK
t4
t10
CS
SDO
0
1
2
3
4
5
6
t11
7
Figure-24 Serial Interface Read Timing with SCLKE=0
Microcontroller Interface Timing Characteristics
56
December 9, 2005
IDT82V2051E
7.2
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
PARALLEL INTERFACE TIMING
Table-50 Multiplexed Motorola Read Timing Characteristics
Symbol
Parameter
Min
tRC
Read Cycle Time
190
tDW
Valid DS Width
180
tRWV
Delay from DS to Valid Read
Max
Unit
ns
ns
15
ns
tRWH
R/W to DS Hold Time
65
ns
tASW
Valid AS Width
10
ns
tADD
Delay from AS active to DS active
0
ns
ns
tADS
Address to AS Setup Time
5
tADH
Address to AS Hold Time
5
tPRD
DS to Valid Read Data Propagation Delay
tDAZ
Delay from DS inactive to data bus High Impedance
tAKD
Acknowledgement Delay
tAKH
Acknowledgement Hold Time
tAKZ
Acknowledgement Release Time
tRecovery
Recovery Time from Read Cycle
ns
5
5
175
ns
20
ns
190
ns
15
ns
5
ns
5
ns
tRecovery
tRC
tDW
DS+CS
tRWH
tRWV
R/W
tASW
tADD
AS
tDAZ
tPRD
READ AD[7:0]
Valid address
Valid Data
tADS tADH
tAKD
tAKH
tAKZ
ACK
Figure-25 Multiplexed Motorola Read Timing
Microcontroller Interface Timing Characteristics
57
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-51 Multiplexed Motorola Write Timing Characteristics
Symbol
Parameter
Min
tWC
Write Cycle Time
120
100
Max
Unit
ns
tDW
Valid DS Width
tRWV
Delay from DS to Valid Write
tRWH
R/W to DS Hold Time
65
ns
tASW
Valid AS Width
10
ns
tADD
Delay from AS active to DS active
0
ns
tADS
Address to AS Setup Time
5
ns
tADH
Address to AS Hold Time
5
tDV
Write Data to DS Hold Time
tAKD
Acknowledgement Delay
tAKH
Acknowledgement Hold Time
tAKZ
Acknowledgement Release Time
tRecovery
Recovery Time from Write Cycle
ns
ns
Delay from DS to Valid Write Data
tDHW
ns
15
15
65
ns
150
5
ns
ns
15
ns
5
ns
5
tRecovery
tWC
tDW
DS+CS
tRWH
tRWV
R/W
tASW
tADD
AS
tDHW
tDV
Write AD[7:0]
Valid address
Valid Data
tADS tADH
tAKD
tAKH
tAKZ
ACK
Figure-26 Multiplexed Motorola Write Timing
Microcontroller Interface Timing Characteristics
58
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-52 Multiplexed Intel Read Timing Characteristics
Symbol
tRC
Parameter
Min
Max
Unit
Read Cycle Time
190
tRDW
Valid RD Width
180
ns
tARD
Delay from ALE to Valid Read
0
ns
Valid ALE Width
10
ns
ns
tALEW
tADS
Address to ALE Setup Time
5
tADH
Address to ALE Hold Time
5
tPRD
RD to Valid Read Data Propagation Delay
tDAZ
Delay from RD inactive to data bus High Impedance
tAKD
Acknowledgement Delay
tAKH
Acknowledgement Hold Time
tAKZ
Acknowledgement Release Time
tRecovery
Recovery Time from Read Cycle
ns
ns
5
5
175
ns
20
ns
190
ns
15
ns
5
ns
5
tRecovery
tRC
tRDW
RD+CS
tALEW
tARD
ALE
tDAZ
tPRD
READ AD[7:0]
Valid address
Valid Data
tADS tADH
tAKD
tAKH
tAKZ
RDY
Figure-27 Multiplexed Intel Read Timing
Microcontroller Interface Timing Characteristics
59
December 9, 2005
IDT82V2051E
SINGLE CHANNEL E1 SHORT HAUL LINE INTERFACE UNIT
Table-53 Multiplexed Intel Write Timing Characteristics
Symbol
Parameter
Min
tWC
Write Cycle Time
120
Max
Unit
ns
tWRW
Valid WR Width
100
ns
tALEW
Valid ALE Width
10
ns
tAWD
Delay from ALE to Valid Write
0
ns
tADS
Address to ALE Setup Time
5
ns
tADH
Address to ALE Hold Time
5
ns
tDV
Delay from WR to Valid Write Data
tDHW
Write Data to WR Hold Time
tAKD
Acknowledgement Delay
tAKH
Acknowledgement Hold Time
tAKZ
Acknowledgement Release Time
tRecovery
Recovery Time from Write Cycle
15
65
ns
ns
5
150
ns
15
ns
5
ns
5
tRecovery
tWC
tWRW
WR+CS
tALEW
tAWD
ALE
tDHW
tDV
Write AD[7:0]
Valid address
Valid Data
tADS tADH
tAKD
tAKH
tAKZ
RDY
Figure-28 Multiplexed Intel Write Timing
Microcontroller Interface Timing Characteristics
60
December 9, 2005
IDT82V2051E
IDT82P2816
SINGLE CHANNEL
E1 SHORT
HAUL LINE INTERFACE UNIT
HIGH-DENSITY
T1/E1/J1
ORDERING INFORMATION
IDT
XXXXXXX
Device Type
XX
X
Process/
Temperature
Range
Blank
Industrial (-40 °C to +85 °C)
PP
Thin Quad Flatpack (TQFP, PP44)
PPG
Green Thin Quad Flatpack
(TQFP, PPG44)
82V2051E
Short Haul LIU
DATASHEET DOCUMENT HISTORY
12/09/2005 pgs. 1, 14, 18, 24, 31, 32, 39, 51, 52, 61
CORPORATE HEADQUARTERS
6024 Silver Creek Valley Road
San Jose, CA 95138
for SALES:
1-800-345-7015 or 408-284-8200
fax: 408-284-2775
www.idt.com
61
for Tech Support:
408-360-1552
email:[email protected]