SE2442L_202415C.pdf

DATA SHEET
SE2442L: 902 to 928 MHz High-Power RF Front-End Module
CTX
 In-home appliances
CSD
PA _OUT
 Smart meters
TX_IN
Applications
 Smart thermostats
Logic
control
Features
PA _IN
PA
 Integrated PA with +30 dBm output power
 Receive pass-through
 Integrated antenna switching
 Single-ended 50 Ω Tx and Rx RF interface
ANT
RX_OUT
 Fast turn-on / turn-off time < 1 μsec
Y0906
 2.0 V to 4.8 V supply operation
Figure 1. SE2442L Block Diagram
 Sleep mode current < 1 μA
 4 x 4 x 0.9 mm 24-pin QFN
 Small QFN (24-pin, 4 mm x 4 mm x 0.9 mm) package
(MSL1, 260°C per JEDEC J-STD-020)
TM
Skyworks Green products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of GreenTM, document number
SQ04–0074.
Description
The SE2442L is a high-performance, integrated RF front-end
module designed for high-power ISM band applications operating
in the 902 to 928 MHz frequency band.
The SE2442L is designed for ease of use and maximum flexibility,
with fully matched 50 Ω input and output, and digital controls
compatible with 1.6 to 3.6 V CMOS levels.
The RF blocks operate over a wide supply voltage range from
2.0 to 4.8 V, allowing the SE2442L to be used in battery powered
applications over a wide spectrum of the battery discharge curve.
A functional block diagram is shown in Figure 1. The pin
configuration and package are shown in Figure 2. Signal pin
assignments and functional pin descriptions are provided in
Table 1.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202415C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 18, 2015
1
19 DNC
20 PA_OUT
21 VCC2
22 DNC
23 VCC0
24 VCC1
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
2
17 GND
GND
3
16 TX_IN
CTX
4
15 GND
DNC
5
14 DNC
RX_OUT
6
13 GND
DNC 10
DNC
8
GND
DNC
ANT 12
PA_IN
DNC 11
18 GND
9
1
7
CSD
Y2592
Figure 2. SE2442L Pinout
(Top View)
Table 1. SE2442L Signal Descriptions
Pin
Name
Description
Pin
Name
Description
1
CSD
Shutdown control input
13
GND
Ground
2
PA_IN
PA input
14
DNC
Do not connect
3
GND
Ground
15
GND
Ground
4
CTX
Transmit enable control input
16
TX_IN
Tx signal to antenna switch (from OMN)
5
DNC
Do not connect
17
GND
Ground
6
RX_OUT
Receive signal to transceiver or SoC
18
GND
Ground
7
DNC
Do not connect
19
DNC
Do not connect
8
GND
Ground
20
PA_OUT
PA output (to OMN)
9
DNC
Do not connect
21
VCC2
Positive power supply, transmit section
10
DNC
Do not connect
22
DNC
Do not connect
11
DNC
Do not connect
23
VCC0
Positive power supply, receive section
12
ANT
Antenna port
24
VCC1
Positive power supply, transmit section
Paddle
GND
Exposed die paddle; electrical and thermal ground (connect to
PCB ground)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
2
November 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202415C
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
Electrical and Mechanical Specifications
The absolute maximum ratings of the SE2442L are provided in
Table 2. The recommended operating conditions are specified in
Table 3, and electrical specifications are provided in Tables 4
through 6.
The state of the SE2442L is determined by the logic provided in
Table 7.
Table 2. SE2442L Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
5.5
V
Supply voltage receive
VCC0
–0.3
Supply voltage transmit – no RF
VCC1, VCC2
–0.3
5.5
V
–0.3
VCC0
V
Control pin voltages
Operating temperature
TOP
–40
+85
°C
Storage temperature
TSTG
–40
+125
°C
Tx input power at PA_IN port
PIN_Tx_MAX
+10
dBm
Rx input power at ANT port
PIN_Rx_MAX
+10
dBm
Electrostatic discharge:
ESD
1000
V
Human Body Model (HBM)
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. Recommended Operating Conditions
Minimum
Typical
Maximum
Units
Ambient temperature
Parameter
TA
Symbol
–40
+25
+85
C
Supply voltage on VCC0, VCC1, and VCC2
VCC
2.0
3.6
4.8
V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202415C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 18, 2015
3
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
Table 4. SE2442L Electrical Specifications: DC (Note 1)
(VCC = 3.6 V, TA = +25 C, as Measured on the Evaluation Board [De-Embedded to the Device], Unless Otherwise Noted)
Parameter
Symbol
ICC_TX30
TX supply current
ICC_TX27
TX supply current
ICQ_TX
Quiescent current
ICC_RXBYPASS
RX supply current
Sleep supply current
ICC_OFF
Test Condition
Min
Typical
Max
Units
Tx mode POUT = +30 dBm
CSD = CTX = high, VCC = 4.8 V
420
mA
Tx mode POUT = 27 dBm
CSD = CTX = high, VCC = 3.6 V
280
mA
No RF
CSD = CTX = high
50
mA
Rx bypass mode
CSD = HIGH, CTX = 0 V
No RF, CTX = CSD = 0 V
0.05
280
μA
1
μA
Max
Units
V
Note 1: Performance is guaranteed only under the conditions listed in the above table.
Table 5. SE2442L Electrical Specifications: Logic Characteristics (Note 1)
(TA = +25 C, as Measured on the Evaluation Board [De-Embedded to the Device], Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Logic input high voltage
VIH
1.6
VCC0
Logic input low voltage
VIL
0
0.3
V
Logic input high current
IIH
1
μA
Logic input low current
IIL
1
μA
Note 1: Performance is guaranteed only under the conditions listed in the above table.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
4
November 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202415C
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
Table 6. SE2442L Electrical Specifications: AC Characteristics (Note 1)
(VCC = 3.6 V, TA = +25 C, as Measured on Evaluation Board [De-Embedded to the Device], All Unused Ports Terminated with 50 Ω,
Unless Otherwise Noted)
Parameter
Symbol
Test Condition
Min
Typical
Max
Units
902
-
928
MHz
Transmit (Tx)
Frequency range
FIN
31.5
30.0
29.0
27.5
dBm
dBm
dBm
dBm
64
%
Output power at ANT port
Pout_FEM
VCC = 4.8 V
VCC = 4.0 V
VCC = 3.6 V
VCC = 3.0 V
PA power added efficiency
PAE
Pout = +28 dBm at PA_OUT port, 915 MHz
Small signal gain
S21
902 to 928 MHz
Small signal gain variation
∆S21
Gain variation across frequency range
Output return loss
S22ANT
Into 50 , ANT port
2 harmonic
HD2
3rd to 10th harmonics
HD3 to HD10
Turn on time
TON
Turn off time
TOFF
Stability
STAB
CW, PIN = +6 dBm
0.1 GHz – 20 GHz
Load VSWR = 6:1
All non-harmonically related outputs
<–42.0 dBm/MHz
Ruggedness
RU
CW, Pout = 27 dBm into 50 Ω, Load VSWR = 10:1
No permanent damage
nd
20
dB
1
dBp-p
–6
dB
POUT = +27 dBm, CW
–22
dBc
POUT = +27 dBm, CW
–72
dBc
From 50% of CTX edge to 90% of final RF output power
1
μs
From 50% of CTX edge to 10% of final RF output power
1
μs
-10
Receive (Rx) (Note 2)
Frequency range
fIN
902
932
MHz
Antenna port return loss
S11ANT
Into 50 , ANT port
–6
dB
Turn on time
TON
Turn off time
TOFF
From 50% of CTX edge
1
μs
From 50% of CTX edge
1
μs
Gain in bypass mode
G_bp
CTX = logic ‘0’ and CSD = logic ‘1’
Input 1-dB compression point in
bypass mode
IP1dB
CTX = logic ‘0’ and CSD = logic ‘1’
Insertion loss from TX_IN to ANT
Tx_ANT
902 to 928 MHz
-
0.7
-
dB
Insertion loss from ANT to RX_OUT
Rx_ANT
902 to 928 MHz
-
0.7
-
dB
–10
–0.7
dB
10
dB
Antenna Functions
Note 1: Performance is guaranteed only under the conditions listed in this table.
Note 2: Receive section can operate with VCC0 = 2.8 V and VCC1 = VCC2 = 0 V
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202415C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 18, 2015
5
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
Table 7. SE2442L Logic Controls
(TA = +25 C)
Mode
Description
CSD
CTX
0
All off (sleep mode) (Notes 1 and 3)
0
0
1
Rx or Tx bypass mode (Notes 1 and 2)
1
0
3
Tx mode (Notes 1 and 2)
1
1
Note 1: Logic ‘0’ level compliant to VIL as specified in Table 5.
Note 2: Logic ‘1’ level compliant to VIH as specified in Table 5.
Note 3: All controls must be at logic ‘0’ in order to achieve the specified sleep current.
Evaluation Board Description
Measure TX Performance
The SE2442L Evaluation Board is used to test the performance of
the SE2442L front-end module (FEM). An Evaluation Board
schematic diagram is provided in Figure 3. A photograph of the
Evaluation Board is shown in Figure 4. A Bill of Materials (BOM)
for the Evaluation Board is provided in Table 8.
Apply an RF signal to connector J10 (PA_IN) to monitor the 900 to
930 MHz amplifier performance. Monitor the output power on
connector J9 (ANT).
Evaluation Board Setup Procedure
Measure RX Performance
Apply an RF signal to connector J9 (ANT) to monitor the 900 to
930 MHz RX path performance. Monitor the output signal on
connector J11 (RX_OUT).
Connect Supply
1. Connect J9, J10, and J11 to 50 Ω instruments. Terminate all
unused ports (if applicable) with 50 Ω.
2. Connect the supply ground to Pin 1 of the J4 header.
CAUTION: Care should be taken not to overdrive the amplifier by
applying too much RF on the input to the device. A
suitable starting input power for the device is
–20 dBm.
3. Connect the DC power supply (2.0 to 4.8 V) to pin 2 of the J4
header.
4. Refer to Table 7 for information about selecting the required RF
path.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
6
November 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202415C
DATA SHEET • SE2431L: 2.4 GHz FRONT-END MODULE
J4
VCC
C3
4.7 uF
CTX
CSD
VCC
C1
10 nF
C12
1 nF
C2
100 pF
C4
33 pF
2
4
6
8
10
12
1
3
5
7
9
11
C6
DNI
L5
6.8 nH
C5
120 pF
CSD
CTX
CSD
PA_IN
GND
CTX
DNC
RX_OUT
24
23
22
21
20
19
SE2442L
U1
C9
4.7 pF
GND
GND
TX_IN
GND
DNC
GND
18
17
16
15
14
13
L2
8.2 nH
C11
2.7 pF
7
8
9
10
11
12
DNC
GND
DNC
DNC
DNC
ANT
J11
SMA
1
2
3
4
5
6
C8
4 pF
VCC1
VCC0
DNC
VCC2
PA_OUT
DNC
25
PAD
J10
SMA
L1
2.7 nH
R1
DNI
J9
SMA
L4
6.8 nH
L3
6.8 nH
C10
2.7 pF
C7
DNI
Y2593
Figure 3. SE2442L Evaluation Board Schematic
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202415C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 18, 2015
7
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
Figure 4. SE2442L Evaluation Board
Table 8. SE2442L Bill of Materials (BOM)
Component
Value
Manufacturer
Mfr Part Number
Package Size
Description
C1
10 nF
Murata
GRM155R71E103KA01
0402
Multilayer ceramic
C2
100 pF
Murata
GRM1555C1H101JZ01
0402
Multilayer ceramic
C3
4.7 uF
Murata
GRM188R60J475KE19
0402
Multilayer ceramic
C4
33 pF
Murata
GRM1555C1H330JZ01
0402
Multilayer ceramic
C5
120 pF
Murata
GRM1555C1H121JA01
0402
Multilayer ceramic
C6, C7
DNI
0402
Multilayer ceramic
C8
4 pF
Taiyo-Yuden
UMK105CG040CW
0402
Standard multilayer ceramic capacitor
C9
4.7 pF
Murata
GRM1555C1H4R7CZ01
0402
Multilayer ceramic
C10, C11
2.7 pF
Murata
GRM1555C1H2R7CZ01
0402
Multilayer ceramic
C12
1 nF
Murata
GRM155R71H102KA01
0402
Multilayer ceramic
J1, J2, J3
SMA
Johnson Components
142-0701-851
J4
6x2
Samtex
TSW-106-07-G-D
100 mil
L1
2.7 nH
Murata
LQG15HN2N7S02D
0402
Inductor
L2
8.2 nH
Murata
LQG15HN8N2J02D
0402
High frequency multilayer
L3, L4, L5
6.8 nH
Murata
LQG18HN6N8S00D
0603
High frequency multilayer
Skyworks
Z387-B
PCB1
R1
U1
DNI
End launch
SE2442L
100 mil header
PCB
0402
Skyworks
SMA end launch straight jack receptacle - tab
contact
QFN400x400
Do not install
900-930 MHz High Power RF FEM
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
8
November 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202415C
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
Package Dimensions
Package and Handling Information
The PCB layout footprint for the SE2442L is provided in Figure 5.
A typical part marking diagram is shown in Figure 6. Package
dimensions are shown in Figure 7, and tape and reel dimensions
are provided in Figure 8.
Instructions on the shipping container label regarding exposure to
moisture after the container seal is broken must be followed.
Otherwise, problems related to moisture absorption may occur
when the part is subjected to high temperatures during solder
assembly.
The SE2442L is rated to Moisture Sensitivity Level 1 (MSL1) at
260 °C, and can be used for lead or lead-free soldering. For
additional information, refer to the Skyworks Application Note,
Solder Reflow Information, document number 200164.
Care must be taken when attaching this product, whether it is
done manually or in a production solder reflow environment.
Production quantities of this product are shipped in a standard
tape and reel format.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202415C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 18, 2015
9
5X 1.02
5X 0.51
5X 0.0
4.40
2.70
5X 0.51
5X 1.02
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
5X 1.02
5X 0.51
2.70
0
4.40
5X 0.0
5X 0.51
5X 1.02
0
0.60
Typ
0.25 Typ
25X Ø0.254
0.500 Typ
Via Pattern
(Note 4)
Board Metal
4.50
2.50
4.40
0.20 Typ
1.00 Typ
1.00 Typ
2.50
4.50
4.40
0.20 Typ
0.60
Typ
0.70
Typ
0.35 Typ
0.500 Typ
Package
Outline
0.25 Typ
0.500 Typ
Stencil Pattern (Note 5)
64% Solder Coverage
on Center Pad
Solder Mask Pattern
(Note 6)
Notes:
1.
2.
3.
4.
All dimensions are in millimeters.
Interpret dimensions and tolerances per ASME Y14.5M-1994.
Unless specified, dimensions are symmetrical about center lines.
Via hole recommendations:
0.025 mm Cu via wall plating (minimum), via hole to be filled with conductive paste and plated over.
5. Stencil recommendations: 0.125 mm stencil thickness, laser cut apertures, trapezoidal walls and rounded
corners offer the best paste release.
6. Solder mask recommendations: Contact board fabricator for recommended solder mask offset and tolerance.
Y2596
Figure 5. PCB Layout Footprint
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
10
November 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202415C
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
Pin 1
Indicator
Material
Finish Symbol
Skyworks
Part Number
Lot Code
Y2597
Figure 6. SE2442L Typical Part Marking
4.00 ±0.05
A
0.85 ±0.05
0.05 C
2.70 ±0.05
0.203 Ref
0.30 X 45°
B
0.000-0.005
Pin 1
Indicator
Pin 1
Indicator
Exposed
Pad
4.00 ±0.05
2.70 ±0.05
0.500
R0.075
Typ
24X 0.20 Min
0.05 C
25X
2X
0.08 C
Top View
See Detail B
See Detail A
4
C
0.05 C
Seating
Plane
2X
Bottom View
Side View
Notes:
0.093 ±0.05
1. All measurements are in millimeters.
2. Dimensions and tolerances according to ASME Y14.5M-2009.
3. Unless otherwise specified, the following values apply:
Decimal Tolerance:
Angular Tolerance:
X.X (1 place) ± 0.1 mm
±1/2°
X.XX (2 places) ± 0.05 mm
X.XXX (3 places) ± 0.025 mm
4. Coplanarity applies to the exposed center ground pad as well as
the terminals.
5. Dimension applies to the metallized terminal. If the terminal has a
radius, the dimension should not be measured in that radius area.
6. Plating requirements per Source Control Drawing (SCD) 2504.
7. Unless specified, dimensions are symmetrical about center lines.
2X R0.075
R0.075
0.40 ±0.05
0.40 ±0.05
0.307 ±0.05
0.25 ±0.05
0.10
0.05
5
C A B
C
Detail A
Scale 2X
(16 Places)
0.25 ±0.05
5
0.10
0.05
C A B
C
Detail B
Scale 2X
(8 Places)
Y2598
Figure 7. SE2442L Package Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202415C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 18, 2015
11
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
8.0 ±0.1
D 1.50 +0.10
4.0 Note 1
1.75 ±0.1
2.0 ±0.05
1.22 ±0.1
0.254 ±0.013
5.5 ±0.05
12.0 ±0.3
4.35 ±0.1
4.35 ±0.1
Pin 1 Indicator
Notes:
1. 10-Sprocket hole pitch cumulative tolerance ±0.2.
2. Camber in compliance with EIA-481.
Y0086
Figure 8. SE2442L-R Tape and Reel Dimensions
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
12
November 18, 2015 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202415C
DATA SHEET • SE2442L: 902 TO 928 MHz HIGH-POWER RF FRONT-END MODULE
Ordering Information
Model Name
SE2442L: 902 to 928 MHz Front-End Module
Manufacturing Part Number
SE2442L
Evaluation Board Part Number
SE2442L-EK1
Copyright © 2012-2015 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by
reference.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202415C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • November 18, 2015
13