200189C.pdf

data sheet
AS200-313LF: PHEMT GaAs IC 2 W
High-Linearity 5–6 GHz T/R Switch
Applications
l
Simplified Block Diagram
T/R switch in WLAN 802.11a systems
J2
CBL
Features
Operating frequency 5–6 GHz
l High linearity 50 dBm IIP3
l High power P
-1 dB > 33 dBm
l Low positive control voltage 3 V
l Low-cost, ultrasmall QFN package
l
A vailable lead (Pb)-free and RoHS-compliant MSL-1 @ 260 °C
per JEDEC J-STD-020
1
6 V1
2
l
J3
CBL
5
3
CBL
J1
4 V2
Description
The AS200-313LF is a 5–6 GHz PHEMT GaAs switch. Designed
for transmit-receive applications, this device is capable of
switching 2 W microwave signals with 3 V control while
maintaining high-linearity performance. The switch covers the
entire 802.11a frequency ranges of 5.15–5.825 GHz. The lowloss, high-isolation, high-linearity and low-cost features make it
ideal for wireless LAN systems in the 802.11a frequency band.
NEW
Skyworks offers lead (Pb)-free, RoHS (Restriction of
Hazardous Substances)-compliant packaging.
Electrical Specifications at 25 °C (0, 3 V)
Parameter(1)
loss(2)
Frequency
Min.Typ.
Max.
Unit
1.5
1.5
1.5
dB
dB
dB
Insertion
5.0–6.0 GHz
5.0–5.4 GHz
5.5–6.0 GHz
1.3
1.3
1.3
Isolation
5.0–6.0 GHz
5.0–5.4 GHz
5.5–6.0 GHz
26
26
26
30
30
30
dB
dB
dB
Return loss(3)
5.0–5.4 GHz
5.5–6.0 GHz
10
10
15
15
dB
dB
1. All measurements made in a 50 W system, unless otherwise specified.
2. Insertion loss changes by 0.003 dB/°C.
3. Insertion loss state.
BUY
NOW
Innovation to GoTM
Now available for purchase online.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200189 Rev. C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • December 4, 2008
1
Data Sheet • AS200-313LF
Operating Characteristics at 25 °C (0, 3 V)
Parameter
Condition
Frequency
Min.Typ.
Max.
Unit
Switching characteristics
Rise, fall On, off Video feedthru
10/90% or 90/10% RF
50% CTL to 90/10% RF
TRISE = 1 ns, BW = 500 MHz
20
50
50
ns
ns
mV
Input power for -0.1 dB compression
VCTL = 0/3 V
5.2 GHz
33
dBm
Harmonics H2, H3
Pin = 30 dBm
5.2 GHz
-65
dBc
Thermal resistance
25
°C/W
Control voltages
Vlow = 0 to 0.2 V @ 20 µA max.
Vhigh = 2.5 V @ 100 µA max. to 5 V @ 200 µA max.
0
-20
-0.2
-22
-0.4
-24
-0.6
-26
Isolation (dB)
Insertion Loss (dB)
Typical Performance Data (0, 3 V)
-0.8
-1.0
-1.2
-28
-30
-32
-1.4
-34
-1.6
-36
-1.8
-38
-40
-2.0
5.0 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6.0
5.0 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6.0
Frequency (GHz)
Frequency (GHz)
Insertion Loss vs. Frequency
Isolation vs. Frequency
-10
-11
Return Loss (dB)
-12
-13
-14
-15
-16
-17
-18
-19
-20
5.0 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 6.0
Frequency (GHz)
Return Loss vs. Frequency
2
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
December 4, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200189 Rev. C
Data Sheet • AS200-313LF
Absolute Maximum Ratings
Truth Table
Value
V1
V2
J1–J2
J1–J3
RF input power
6 W max. > 900 MHz
0/7 V control
0
Vhigh
Isolation
Insertion loss
Vhigh
0
Insertion loss
Isolation
Control voltage
-0.2 V, +7 V
Operating temperature
-40 °C to +85 °C
Storage temperature -65 °C to +150 °C
Characteristic
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: A lthough this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all
times from ESD. Static charges may easily produce
potentials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
All other conditions not recommended.
Vhigh = 2.5 to 5 V.
QFN-6
Pin 1
Indicator
2
0.7 ± 0.05
3
0.20 ± 0.05
4X 10° + 2°
4X 10° - 10°
0.125 Max.
0.125 Max.
0.17/0.30
0.025 ± 0.025
0.9 ± 0.1
10X (R0.127)
1.219 ± 0.1
Recommended Solder Reflow Profiles
Refer to the “Recommended Solder Reflow Profile”
Application Note.
Tape and Reel Information
Refer to the “Discrete Devices and IC Switch/Attenuators
Tape and Reel Package Orientation” Application Note.
(1.9)
0.61 ± 0.1
4X (R0.127)
0.95
6X 0.35 + 0.08
6X 0.35 - 0.02
Exposed Heat
Sink Plug
0.61 ± 0.1
0.84 ± 0.1
0.29 + 0.16
0.29 - 0.09
6X 0.20 Min.
Pin Out (Top View)
J2
CBL
GND
J3
CBL
1
6
2
5
3
4
V1
CBL
J1
V2
DC blocking capacitors (Cbl) must be supplied externally.
Cbl = 15 pF.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
200189 Rev. C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • December 4, 2008
3
Data Sheet • AS200-313LF
Copyright © 2002, 2003, 2004, 2005, 2006, 2007, 2008, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and
Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, “Breakthrough Simplicity” and “Innovation to Go” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Thirdparty brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.
com, are incorporated by reference.
4
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
December 4, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200189 Rev. C