all converter caty11414741705

®
MSCW01 SERIES
DC/DC CONVERTER 1W, SMD Package
FEATURES
►Ultra compact SMD Package
►Wide 2:1 lnput Range
►Fully regulated Outputs
►Low Ripple and Noise
►Operating Temp. Range -40°C to +85°C
►I/O-isolation Voltage 1500VDC
►Continuous Short-circuit Protection
►Remote On/Off Control
►Qualified for Lead-free Reflow Process
►UL/cUL/IEC/EN 60950-1 Safety Approval
► 3 Years Product Warranty
PRODUCT OVERVIEW
The MSCW01 series is a family of compact 1W dc/dc-converters with wide 2:1 input voltage ranges and tightly regulated output voltages.
They work with high efficiency over the full load range and come with a remote On/Off control input.
High efficiency to 82% allows operating temperatures up to +75°C without power derating. The very small footprint of these converters make them an ideal
solution for many space critical applications in communication equipment, instrumentation and many other battery operated applications.
Model Selection Guide
Model
Input
Output
Number
Voltage
Voltage
Output Current
(Range)
VDC
MSCW01-05S05
MSCW01-05S12
MSCW01-05S15
MSCW01-05D12
MSCW01-05D15
MSCW01-12S05
MSCW01-12S12
MSCW01-12S15
MSCW01-12D12
MSCW01-12D15
MSCW01-24S05
MSCW01-24S12
MSCW01-24S15
MSCW01-24D12
MSCW01-24D15
MSCW01-48S05
MSCW01-48S12
MSCW01-48S15
MSCW01-48D12
MSCW01-48D15
VDC
5
12
15
±12
±15
5
12
15
±12
±15
5
12
15
±12
±15
5
12
15
±12
±15
5
(4.5 ~ 9)
12
(9 ~ 18)
24
(18 ~ 36)
48
(36 ~ 75)
Input Current
Max.
@Max. Load
@No Load
mA
200
83
67
±42
±33
200
83
67
±42
±33
200
83
67
±42
±33
200
83
67
±42
±33
mA(typ.)
256
252
248
255
248
105
105
102
104
103
53
51
51
51
50
26
26
26
26
25
mA(typ.)
40
20
10
7
Max. capacitive
Reflected
Load
Ripple
(typ.)
current
@Max. Load
mA (typ.)
%
78
79
81
79
80
79
79
82
81
80
79
82
82
82
82
79
80
80
81
81
μF
1680
820
680
470#
330#
1680
820
680
470#
330#
1680
820
680
470#
330#
1680
820
680
470#
330#
# For each output
E-mail:[email protected]
2014/10/22 REV:2
Tel:886-6-2923150
Page 1 of 4
80
40
30
20
Efficiency
®
MSCW01 SERIES
DC/DC CONVERTER 1W, SMD Package
Input Specifications
Parameter
Input Surge Voltage (1 sec. max.)
Start-Up Threshold Voltage
Internal Filter Type
Model
Min.
Typ.
Max.
5V Input Models
-0.7
---
15
12V Input Models
-0.7
---
25
24V Input Models
-0.7
---
50
48V Input Models
-0.7
---
100
5V Input Models
---
---
4.5
12V Input Models
---
---
9
24V Input Models
---
---
18
48V Input Models
---
---
All Models
Unit
VDC
36
Capacitor
Output Specifications
Parameter
Output Voltage Setting Accuracy
Conditions
Output Voltage Balance
Line Regulation
Load Regulation
Minimum Load
Ripple & Noise
Transient Recovery Time
Transient Response Deviation
Temperature Coefficient
Short Circuit Protection
Min.
---
Typ.
---
Max.
±1.0
Unit
%Vnom.
Dual Output, Balanced Loads
--------Vin=Min. to Max. @Full Load
----Single Output
Min. Load to Full Load
----Dual Output
----Single Output
Io=10% to 90%
----Dual Output
No minimum Load Requirement
0-20 MHz Bandwidth
------250
25% Load Step Change
--±3
----Continuous
±1.0
±0.2
±1.0
±1.0
±0.5
±0.8
%
%
%
%
%
%
75
---
mV P-P
μsec
±5
±0.02
%
%/℃
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
60 Seconds
1500
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100KHz, 1V
---
---
50
pF
---
220
---
KHz
2,800,000
---
---
Hours
I/O Isolation Voltage
Switching Frequency
MTBF(calculated)
MIL-HDBK-217F@25℃, Ground Benign
Moisture Sensitivity Level (MSL)
Safety Approvals
IPC/JEDEC J-STD-020D.1
Level 2
UL/cUL 60950-1 recognition (CSA certificate), IEC/EN 60950-1(CB-report)
Remote On/Off Control
Parameter
Conditions
Min.
Converter On
Typ.
Max.
Unit
---
mA
Open or high impedance
Converter Off
2~4mA current applied via 1Kohm resistor
Standby Input Current
Supply Off & Nominal Vin
---
2.5
Environmental Specifications
Parameter
Operating Ambient Temperature Range (See
Power Derating Curve)
Conditions
Min.
Max.
Unit
Natural Convection
-40
+85
℃
℃
Case Temperature
---
+95
Storage Temperature
-55
+125
℃
Humidity (non condensing)
---
95
% rel. H
Lead Temperature (1.5mm from case for 10Sec.)
---
260
℃
E-mail:[email protected]
2014/10/22 REV:2
Tel:886-6-2923150
Page 2 of 4
®
MSCW01 SERIES
DC/DC CONVERTER 1W, SMD Package
Power Derating Curve
Notes
1
Specifications typical at Ta=+25℃, resistive load, nominal input voltage, rated output current unless otherwise noted.
2
We recommend to protect the converter by a slow blow fuse in the input supply line.
3
Other input and output voltage may be available, please contact factory.
4
That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
5
Specifications are subject to change without notice.
Package Specifications
Mechanical Dimensions
Connecting Pin Patterns
18.9 [0.74]
15.24 [0.60]
6
7
Top View
1
2
18.6 [0.73]
8
13.7 [0.54]
9
17.2 [0.68]
14
16.15 [0.64]
2.54
[0.1]
12.7 [0.5]
13.7 [0.54]
1.8 [0.1]
1.6 [0.06]
8.7 [0.34]
8.45 [0.33]
2.54 [0.10]
S SEATING
PLANE
1.1 [0.04]
15.0 [0.6]
0~
4
0.25 [0.01]
►All
dimensions in mm (inches)
►Tolerance: X.X±0.5
0.15 S
Pin Connections
Pin
Single Output
Dual Output
1
-Vin
-Vin
2
Remote On/Off
Remote On/Off
6
NC
Common
7
NC
-Vout
8
+Vout
+Vout
9
-Vout
Common
14
+Vin
+Vin
NC: No Connection
2014/10/22 REV:2
Tel:886-6-2923150
Page 3 of 4
(X.XX±0.02)
X.XX±0.25 ( X.XXX±0.01)
►Pins
E-mail:[email protected]
2.4
5
[0.10]
1.00 [0.04]
±0.05(±0.002)
Physical Characteristics
Case Size
:
18.9x13.7x8.45mm (0.74x0.54x0.33 inches)
Case Material
:
Non-Conductive Black Plastic (flammability to UL 94V-0 rated)
Pin Material
:
Phosphor bronze
Weight
:
4.5g
®
MSCW01 SERIES
DC/DC CONVERTER 1W, SMD Package
Test Setup
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100 KHz) to simulate source impedance.
Capacitor Cin, offsets possible battery impedance. Current ripple is measured at the input terminals of the module, measurement bandwidth is 0-500 KHz.
To Oscilloscope
+
+
Battery
+Vin
Lin
Current
Probe
Cin
+Out
DC / DC
Converter
-Vin
Load
-Out
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between
50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Copper Strip
Single Output
DC / DC
Converter
-Vin
Cout
-Out
Scope
Resistive
Load
Copper Strip
+Vin
+Out
Copper Strip
Dual Output
DC / DC
Converter
Com.
Copper Strip
-Vin
-Out
Scope
Cout
Cout
Resistive
Load
Scope
Copper Strip
Technical Notes
Remote On/Off
Negative logic remote on/off turns the module off during a logic high voltage on the remote on/off pin, and on during a logic low. To turn the power module on and off,
the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent.
A logic high is 2~4mA current applied via 1Kohm resistor. A logic low is open circuit or high impedance.
Maximum Capacitive Load
The MSCW01 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up,
affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet.
Input Source Impedance
The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In
applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup.
Capacitor mounted close to the power module helps ensure stability of the unit, it is commended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω
at 100 KHz) capacitor of a 8.2μF for the 5V input device, a 3.3μF for the 12V input devices and a 1.5μF for the 24V and 48V devices.
+
DC Power
Source
+Vin
+
+Out
DC / DC
Converter
Load
Cin
-
-Vin
-Out
Output Ripple Reduction
A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is
recommended to use 3.3μF capacitors at the output.
+
+Vin
DC Power
Source
-
+Out
Single Output
DC / DC
Converter
-Vin
+
Cout
Load
-Out
+Vin
DC Power
Source
-
+Out
Dual Output
DC / DC Com.
Converter
-Vin
-Out
Cout
Load
Load
Cout
Thermal Considerations
Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the
maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined from
measurements obtained in a test setup.
Position of air velocity
probe and thermocouple
15mm / 0.6in
50mm / 2in
Air Flow
DUT
18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan
Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected]
Minmax Technology Co., Ltd.
2014/10/22 REV:2