Datasheet

POWR-GARD® Fuse Datasheet
TRADITIONAL HIGH-SPEED FUSES
150/250/500/600/700 Vac • Very Fast-Acting • 1-1200 A
Ordering Information
AMPERE
RATINGS
1
2
3
4
5
6
7
8
9
10
12
15
17 1⁄ 2
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225
250
275
300
350
400
450
500
550
600
700
800
900
1000
1200
Specifications
Voltage Ratings
L15S:
L25S:
L50S:
L60S:
KLC:
L70S:
150 Vac/dc (1 – 60 A)
150 Vac (70 – 1000 A)
100 Vdc (70 – 1000 A)
250 Vac/dc (1 – 200 A)
250 Vac (225 – 800 A)
200 Vdc (225 – 800 A)
500 Vac/450 Vdc
600 Vac
600 Vac
700 Vac/650 Vdc
L25S series fuses are Littelfuse Certified for DC ratings
shown in Rating Table.
Interrupting Rating
AC:
200 kA rms
(L15S series 100 kA)
DC:
20 kA
Ampere Range
Approvals 1 – 1200 A See Rating Table for
ratings available in each series.
UL Recognized (File: E71611)
CSA Recognized (File: LR29862)
Recommended Fuse Holders
1LFS101/1LFS102....................................121
LSCR001/LSCR002..................................120
Web Resources
For additional information, visit:
littelfuse.com/high-speed
‡
SERIES ORDERING NUMBER
L15S
L15S001
L15S002
L15S003
L15S004
L15S005
L15S006
L15S007
L15S008
L15S009
L15S010
L15S012
L15S015
–
L15S020
L15S025
L15S030
L15S035
L15S040
L15S045
L15S050
L15S060
L15S070
L15S080
L15S090
L15S100
–
L15S125
L15S150
–
L15S200
–
L15S250
–
L15S300
L15S350
L15S400
L15S450
L15S500
–
L15S600
–
L15S800
–
L15S1000
–
L25S
L25S001
L25S002
L25S003
L25S004
L25S005
L25S006
–
L25S008
–
L25S010
L25S012
L25S015
–
L25S020
L25S025
L25S030
L25S035
L25S040
L25S045
L25S050
L25S060
L25S070
L25S080
L25S090
L25S100
–
L25S125
L25S150
L25S175
L25S200
L25S225
L25S250
L25S275
L25S300
L25S350
L25S400
L25S450
L25S500
–
L25S600
L25S700
L25S800
–
–
–
L50S
–
–
–
–
–
–
–
–
–
L50S010
L50S012
L50S015
–
L50S020
L50S025
L50S030
L50S035
L50S040
–
L50S050
L50S060
L50S070
L50S080
L50S090
L50S100
–
L50S125
L50S150
L50S175
L50S200
L50S225
L50S250
L50S275
L50S300
L50S350
L50S400
L50S450
L50S500
L50S550
L50S600
L50S700
L50S800
–
–
–
L60S
L60S001
L60S002
L60S003
L60S004
L60S005
L60S006
–
L60S008
–
L60S010
L60S012
L60S015
L60S17.5
L60S020
L60S025
L60S030
L60S035
L60S040
L60S045
L60S050
L60S060
L60S070
L60S080
L60S090
L60S100
–
L60S125
L60S150
L60S175
L60S200
L60S225
L60S250
–
L60S300
L60S350
L60S400
L60S450
L60S500
–
L60S600
L60S700
L60S800
–
–
–
KLC ‡
KLC001
KLC002
KLC003
KLC004
KLC005
KLC006
KLC007
KLC008
–
KLC010
KLC012
KLC015
KLC17.5
KLC020
KLC025
KLC030
KLC035
KLC040
KLC045
KLC050
KLC060
KLC070
KLC080
KLC090
KLC100
KLC110
KLC125
KLC150
KLC175
KLC200
KLC225
KLC250
–
KLC300
KLC350
KLC400
KLC450
KLC500
–
KLC600
KLC700
KLC800
–
–
–
L70S
–
–
–
–
–
–
–
–
–
L70S010
–
L70S015
–
L70S020
L70S025
L70S030
L70S035
L70S040
–
L70S050
L70S060
L70S070
L70S080
L70S090
L70S100
–
L70S125
L70S150
L70S175
L70S200
L70S225
L70S250
–
L70S300
L70S350
L70S400
L70S450
L70S500
–
L70S600
L70S700
L70S800
–
–
–
KLC series fuses are recommended for replacement use only.
Note: High-Speed fuses are designed for fixed installations. They are not intended for use in moving vehicle applications.
littelfuse.com
1 of 8
© 2015 Littelfuse POWR-GARD® Products
Rev: 052215
POWR-GARD® Fuse Datasheet
TRADITIONAL HIGH-SPEED FUSES
Dimensions
AMPERE
RATING
FIG.
NO.
A
B
C
DIMENSIONS INCHES (mm)
D
E
F
G
H
L15S Series, 150 Vac
1 – 30
1
11⁄2 (38.1)
—
31 – 60
1
2 (50.8)
—
61 – 450
3
1 5 ⁄32 (29.4)
1 7⁄8 (47.6)
451 – 1000
3
11⁄4 (31.8)
3 8
⁄ (9.5)
13 32
⁄ (15.9)
13 16
5 8
⁄ (10.3)
—
—
—
—
⁄ (20.6)
—
—
—
—
2 3 ⁄16 (55.6) 2 21 ⁄32 (67.5)
115 ⁄16 (49.2) 2 9 ⁄16 (65.1)
3 1⁄2 (88.9)
1 (25.4)
⁄ (17.1)
43 64
11⁄2 (38.1)
1 (25.4)
⁄ (7.9)
3 16
⁄ (10.3)
14
5 16
13 32
D
C
⁄ (4.8)
A
⁄ (6.4)
Fig. 1
L25S Series, 250 Vac
1 – 30
1
2 (50.8)
—
31 – 60
2
15 ⁄8 (41.3)
2 1⁄4 (57.2)
2 1⁄2 (63.5)
3 3 ⁄ 16 (81.0)
13 16
61 – 200
3
15 ⁄8 (41.3)
2 5 ⁄16 (58.7)
2 7⁄16 (61.9)
3 1⁄8 (79.4)
1 7⁄32 (31.0)
1 (25.4)
5 16
201 – 700
3
119 ⁄32 (40.5) 2 9 ⁄32 (57.9) 2 29 ⁄32 (73.8) 3 27⁄32 (97.6)
11⁄ 2 (38.1)
1 (25.4)
13 32
701 – 800
3
1 ⁄ (40.5) 2 ⁄ (57.9) 2 ⁄ (73.8) 3 ⁄ (97.6)
2 (50.8)
1 ⁄ (38.1)
13 32
19 32
9 32
⁄ (12.7)
12
29 32
⁄ (14.3)
—
9 16
27 32
—
⁄ (20.6)
⁄ (18.3)
23 32
12
—
—
⁄ (8.7)
18
⁄ (7.9)
3 16
⁄ (10.3)
14
⁄ (10.3)
14
11 32
⁄ (3.2)
⁄ (4.8)
⁄ (6.4)
⁄ (6.4)
L50S Series, 500 Vac / 450 Vdc
10 – 30
1
2 (50.8)
—
31 – 60
2
1 ⁄ (41.3)
2 ⁄ (57.2)
61 – 100
3
2 1 ⁄8 (54.0)
2 11 ⁄16 (68.3)
2 ⁄ (71.4) 2 ⁄ (74.6)
5 8
14
⁄ (12.7)
12
⁄ (14.3)
—
9 16
12
2 ⁄ (63.5)
3 3 ⁄16 (81.0)
3 (76.2)
—
—
⁄ (20.6)
23 32
⁄ (18.3)
11 32
3 5 ⁄8 (92.1)
1 (25.4)
.670 (17.0)
11 32
3 ⁄ (92.1)
5 16
13 16
⁄ (8.7)
⁄ (8.7)
1 8
⁄ (7.9)
3 16
101 – 200
3
2 ⁄ (54.0)
1 ⁄ (31.0)
.895 (22.7)
201 – 400
3
2 3 ⁄ 32 (53.2) 2 25 ⁄ 32 (70.6) 3 13 ⁄ 32 (86.5) 4 11 ⁄ 32 (110.3)
11⁄2 (38.1)
1 (25.4)
13 32
401 – 600
3
2 ⁄ (56.4) 2 ⁄ (73.8) 3 ⁄ (89.7) 4 ⁄ (113.5)
2 (50.8)
12
1 ⁄ (38.1)
13 32
601 – 800
3
2 7⁄ 32 (56.4) 4 9 ⁄ 32 (108.7) 4 5 ⁄8 (117.5) 6 15 ⁄ 32 (164.3) 2 1⁄ 2 (63.5)
2 (50.8)
17 32
1 8
7 32
13 16
29 32
15 16
17 32
5 8
15 32
7 32
—
⁄ (3.2)
1 8
F
⁄ (3.2)
A
B
C
D
G
⁄ (4.75)
⁄ (10.3)
14
⁄ (10.3)
14
⁄ (6.4)
⁄ (13.5)
3 8
H
E
Fig, 2
⁄ (6.4)
⁄ (9.5)
L60S Series, 600 Vac
1 – 30
1
5 (127.0)
31 – 60
2
2 25 ⁄32 (70.6) 3 7⁄16 (87.3) 3 11 ⁄16 (93.7) 4 3 ⁄8 (111.1)
⁄ (20.6)
23 32
61 – 100
2
2 29 ⁄32 (73.8) 3 17⁄32 (89.7) 3 25 ⁄32 (96.0) 4 15 ⁄32 (113.5) 11 ⁄16 (27.0)
23 32
101 – 200
2
2 ⁄ (73.8) 3 ⁄ (90.5)
3 ⁄ (95.3) 4 ⁄ (111.9) 1 ⁄ (33.3)
1 (25.4)
5 16
201 – 400
2
2 29 ⁄32 (73.8) 3 31 ⁄32 (100.8) 4 5 ⁄32 (105.6) 5 1⁄8 (130.2) 137⁄64 (40.1)
1 (25.4)
13 32
401 – 600
2
2 7⁄8 (73.0) 3 31 ⁄32 (100.8) 4 9 ⁄64 (105.2) 5 1⁄8 (130.2)
2 1 ⁄16 (52.8)
11⁄2 (38.1)
13 32
601 – 800
2
3 1 ⁄32 (77.0) 5 5 ⁄32 (133.4) 5 11 ⁄ 32 (135.7) 7 1⁄4 (184.2)
2 1⁄2 (63.5)
2 (50.8)
17 32
—
—
29 32
—
9 16
⁄ (15.9)
5 8
3 4
⁄ (20.6)
—
13 16
13 32
—
13 16
5 16
—
⁄ (18.3)
11 32
⁄ (8.7)
⁄ (18.3)
11 32
—
⁄ (3.2)
18
⁄ (8.7)
18
⁄ (7.9)
3 16
⁄ (3.2)
⁄ (10.3)
14
⁄ (10.3)
14
⁄ (13.5)
3 8
⁄ (4.8)
⁄ (6.4)
F
⁄ (6.4)
G
⁄ (9.5)
L70S Series, 700 Vac / 650 Vdc
10 – 30
1
2 (50.8)
—
31 – 60
2
2 7⁄8 (73.0)
3 7⁄16 (87.3)
61 – 100
2
2 ⁄ (73.0)
101 – 200
⁄ (12.7)
12
43 64
3 ⁄ (90.5) 3 ⁄ (93.7) 4 ⁄ (111.1)
1 ⁄ (31.0)
29 32
2
2 27⁄ 32 (72.2) 3 17⁄ 32 (89.7) 4 5 ⁄ 32 (105.6) 5 3 ⁄ 32 (129.4)
1 1⁄ 2 (38.1)
1(25.4)
13 32
201 – 400
2
2 ⁄ (72.2) 3 ⁄ (89.7) 4 ⁄ (105.6) 5 ⁄ (129.4)
2 (50.8)
12
1 ⁄ (38.1)
13 32
401 – 600
2
2 27⁄ 32 (72.2) 4 29 ⁄ 32 (124.6) 5 1⁄4 (133.4) 7 3 ⁄ 32 (180.2) 2 1⁄ 2 (63.5)
2 (50.8)
17 32
601 – 800
4
27 32
9 16
17 32
11 16
5 32
4 3 ⁄8 (111.1)
—
1 (25.4)
78
3 3 ⁄4 (95.3)
⁄ (14.3)
9 16
3 8
3 32
3 5 ⁄16 (84.1) 5 5 ⁄16 (134.9) 6 13 ⁄16 (173.0)
—
7 32
2 7⁄8 (73.0)
⁄ (17.1)
11 32
⁄ (22.9)
5 16
2 (50.8)
18
⁄ (7.9)
3 16
⁄ (10.3)
14
⁄ (10.3)
14
⁄ (13.5)
3 8
⁄ (15.9)
5 8
⁄ (3.2)
⁄ (4.8)
⁄ (6.4)
⁄ (6.4)
⁄ (9.5)
H: 3 ⁄ 8 (9.5)
J: 5 ⁄16 (7.9)
KLC Series, 600 Vac
1 – 30
2
17⁄8 (47.6)
2 1⁄2 (63.5)
—
2 7⁄8 (73.0)
31 – 60
2
2 3 ⁄4 (69.9)
3 3 ⁄8 (85.7)
61 – 100
3
2 7⁄8 (73.0)
3 21 ⁄ 32 (92.9) 4 1 ⁄16 (103.2)
101 – 200
3
2 ⁄ (72.2) 3 ⁄ (89.7) 4 ⁄ (111.1) 5 ⁄ (129.4)
201 – 400
3
401 – 800
3
3 5 ⁄8 (92.1) 4 5 ⁄16 (109.5)
13 32
⁄ (20.6)
23 32
13 16
14
⁄ (6.4)
3 64
⁄ (18.3)
11 32
⁄ (8.7)
1 8
⁄ (10.3)
1 8
⁄ (10.3)
14
⁄ (19.1)
13 32
1 ⁄ (38.1)
1 (25.4)
13 32
2 27⁄ 32 (72.2) 4 21 ⁄ 32 (118.3) 4 27⁄ 32 (123.0) 6 1⁄4 (158.8)
2 (50.8)
1 5 ⁄8 (41.3)
9 16
2 ⁄ (72.2) 4 ⁄ (118.3) 5 ⁄ (135.7) 6 ⁄ (158.8)
2 ⁄ (63.5)
2 (50.8)
9 16
27 32
17 32
21 32
3 8
11 32
3 32
14
1 (25.4)
⁄ (10.3)
3 4
27 32
5 (127.0)
⁄ (14.3)
9 16
12
12
E
Fig. 3
—
⁄ (8.7)
H
A
B
C
D
⁄ (1.2)
⁄ (3.2)
⁄ (3.2)
⁄ (6.4)
⁄ (14.3)
14
⁄ (14.3)
3 8
F
G
A
B
C
J
E
Fig. 4
⁄ (6.4)
⁄ (9.5)
Note: High-Speed fuses are designed for fixed installations. They are not intended for use in moving vehicle applications.
littelfuse.com
2 of 8
© 2015 Littelfuse POWR-GARD® Products
Rev: 052215
H