TM3041PM

Available as:
RF AMPLIFIER
MODEL TM3041PM
Features
TM3041PM, 4 Pin TO-8 (T4)
TN3041PM, 4 Pin Surface Mount (SM3)
FP3041PM, 4 Pin Flatpack (FP4)
BX3041PM, Connectorized Housing (H1)
Typical Intermodulation Performance at 25 ºC
 Superior Phase Noise Performance
 High Output Power: +24 dBm Typical
 Operating Temp. -55 ºC to +85 ºC
 Environmental Screening Available
Second Order Harmonic Intercept Point ...... +55 dBm (Typ.)
Second Order Two Tone Intercept Point ....... +50 dBm (Typ.)
Third Order Two Tone Intercept Point ........... +38 dBm (Typ.)
Maximum (No Damage) Ratings
Specifications
CHARACTERISTIC
Frequency (MHz)
TYPICAL
Ta= 25 ºC
MIN/MAX
Ta = -55 ºC to +85 ºC
10 - 300 MHz
10 - 300 MHz
Gain (dB)
16.5
15.5 Min.
Power @ 1 dB
Comp. (dBm)
+24.0
+23.0 Min.
Reverse Isolation (dB)
VSWR
In
Out
Noise Figure (dB)
Power
Vdc
mA
- 20
1.80:1
1.80:1
2.8
+15
80
-19 Max.
2.0:1 Max.
2.0:1 Max.
4.0 Max.
+15
85 Max.
Guaranteed Phase Noise Performance (dBc/Hz)
Note: Care should always be taken to effectively ground the case of each unit.
Revision 4/25/2012
Ambient Operating Temperature ................ -55ºC to +100 ºC
Storage Temperature ................................. -62ºC to +125 ºC
Case Temperature .................................................. +125 ºC
DC Voltage .......................................................... +18 Volts
Continuous RF Input Power .................................. +13 dBm
Short Term RF Input Power ............. 50 mW (1 Minute Max.)
Maximum Peak Power .................... 0.5 Watt (3 μsec Max.)
Frequency
100 Hz
1 kHz
10 kHz
100 kHz
1 MHz
Typical
Guarantee
-155
-170
-170
-170
-170
-160
-175
-175
-175
-175
*
*Phase Noise Performance is Measured and Guaranteed at 300 MHz at 25C.
Typical Performance Data
Gain (dB)
18
17
-10
16
-20
15
-30
14 Start 10 MHz
Stop 300 MHz
1 dB Comp. (dBm)
+25
+23
3
2.5
+22
2.0
Input VSWR
Stop 300 MHz
-150
2
Stop 300 MHz
Noise Figure (dB)
4
3.5
-170
-190
100
Start 10 MHz
Stop 300 MHz
Output VSWR
Legend
Stop 300 MHz
+25 ºC
1.0Start 10
1k
10k
100k
 Agilent ES5500 System
MHz
1M
_________Guarantee __ __ __ __Typical
Residual Phase Noise Test Conditions:
 Carrier Frequency: 300 MHz
 Power Output +21.0 dBm
 Temperature: 25 oC
1.5
1.2 Start 10 MHz
-160
-180
2.0
1.6
Phase Noise (dBc/Hz)
-130
-140
-40 Start 10 MHz
+24
+21Start 10 MHz
Reverse Isolation (dB)
-0
Stop 300 MHz
+85 ºC - - - - - - -55 ºC
Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, Florida 32905 · PH (888) 553-7531 · Fax (888) 553-7532
www.SpectrumMicrowave.com Spectrum Microwave · 2707 Black Lake Place · Philadelphia, Pennsylvania 19154 · PH (215) 464-4000 · Fax (215) 464-4001