RF AMPLIFIER MODEL TM6189 Available as: Features Typical Intermodulation Performance at 25 ºC High Gain: 22 dB Typical Operating Temp. -55 ºC to +85 ºC Environmental Screening Available Second Order Harmonic Intercept Point........+42 dBm (Typ.) Second Order Two Tone Intercept Point.........+35 dBm (Typ.) Third Order Two Tone Intercept Point.............+30 dBm (Typ.) Specifications CHARACTERISTIC Frequency Gain (dB) Gain Flatness (dB) Gain Variation (dB) IP3 (dBm)* Absolute Maximum (No Damage) Ratings TYPICAL Ta= 25 ºC 50 - 800 MHz 22 ±0.5 1.3 +30 MIN/MAX Ta = -55 ºC to +85 ºC 100 - 800 MHz 20.5 Min. ±1.0 Max. +25 Min. IP2 (dBm)* +35 +30 Min. IP2H (dBm) +42 +37 Min Power @ 1 dB Comp. (dBm) +17.5 +16 Min. Reverse Isolation (dB) -29 -25 Max. 1.4:1 1.4:1 2.2:1 Max. 2.2:1 Max. 4.5 +15 45 6.0 Max. +15 50 Max. VSWR In Out Noise Figure (dB) Power Vdc mA TM6189, 4 Pin TO-8 (T4) TN6189, 4 Pin Surface Mount (SM3) FP6489, 4 Pin Flatpack (FP4) BX6189, Connectorized Housing (H1) Ambient Operating Temperature ................ -55ºC to +100 ºC Storage Temperature .................................-62ºC to +125 ºC Case Temperature .................................................. +125 ºC DC Voltage .......................................................... +17 Volts Continuous RF Input Power .................................. +13 dBm Short Term RF Input Power...... 50 Milliwatts (1 Minute Max.) Maximum Peak Power.................... 0.5 Watt (3 µsec Max.) Note: Care should always be taken to effectively ground the case of each unit. * IP3 and IP2 are in band output intercept points. Typical Performance Data Legend +25 ºC +85 ºC - - - - - - -55 ºC Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, Florida 32905 · PH (888) 553-7531 · Fax (888) 553-7532 Rev. 12/3/10 www.SpectrumMicrowave.com Spectrum Microwave · 2707 Black Lake Place · Philadelphia, Pennsylvania 19154 · PH (215) 464-4000 · Fax (215) 464-4001