V48SH1R050

FEATURES


High efficiency: 84% @ 1.0V/50A
Size:
33.0x22.8x9.5mm (1.30”x0.90”x0.37”)
( W/O heat-spreader )
33.0x22.8x12.7mm (1.30”x0.90”x0.50”)
( With heat-spreader )

Industry standard footprint and pinout

Fixed frequency operation

SMD and through-hole versions

Input UVLO

OTP and output OCP, OVP

Output voltage trim: -20%, +10%

Monotonic startup into normal and
pre-biased loads

1500V isolation and basic insulation

No minimum load required

No negative current during power or
enable on/off

ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS18001 certified manufacturing
facility

UL/cUL 60950-1 (US & Canada)
th
Delphi Series V48SH, 1/16 Brick 50W
DC/DC Power Modules: 48V in, 1.0V, 50Aout
The Delphi Series V48SH, 1/16
th
Brick, 48V input, single output,
OPTIONS
isolated DC/DC converter, is the latest offering from a world leader in

SMD pins
power systems technology and manufacturing ― Delta Electronics,

Short pin lengths available
Inc. This product family provides up to 100 watts of power in an

Positive/Negative remote On/Off

Open Frame/Heat spreader
industry standard 1/16
th
brick form factor (1.30” x 0.90”). The 1.0V
output offers one of the highest output currents available and provides
up to 84% efficiency at full load. With creative design technology and
optimization of component placement, these converters possess
outstanding electrical and thermal performance, as well as extremely
high reliability under highly stressful operating conditions.For lower
power needs, but in a similar small form factor, please check out Delta,
V36SE (50W or 15A), S48SP (36W or 10A) and S36SE (17W or 5A)
series standard DC/DC modules.
DS_V48SH1R050_10282013
APPLICATIONS

Optical Transport

Data Networking

Communications

Servers
TECHNICAL SPECIFICATIONS
(TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.)
PARAMETER
NOTES and CONDITIONS
V48SH1R050 (Standard)
Min.
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Transient (100ms)
Operating Ambient Temperature
Storage Temperature
Input/Output Isolation Voltage
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current
No-Load Input Current
Off Converter Input Current
2
Inrush Current (I t)
Input Reflected-Ripple Current
Input Voltage Ripple Rejection
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Load
Over Line
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Operating Output Current Range
Output Over Current Protection
DYNAMIC CHARACTERISTICS
Output Voltage Current Transient
Positive Step Change in Output Current
Negative Step Change in Output Current
Settling Time (within 1% Vout nominal)
Turn-On Transient
Start-Up Time, From On/Off Control
Start-Up Time, From Input
Maximum Output Capacitance
EFFICIENCY
100% Load
60% Load
ISOLATION CHARACTERISTICS
Input to Output
Isolation Resistance
Isolation Capacitance
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control, Negative Remote On/Off logic
Logic Low (Module On)
Logic High (Module Off)
ON/OFF Control, Positive Remote On/Off logic
Logic Low (Module Off)
Logic High (Module On)
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
GENERAL SPECIFICATIONS
0
100ms
-40
-55
36
32.5
30.5
1
DS_V48SH1R050_10282013
34
32
2
100% Load, 36Vin
30
10
With 100uF external input capacitor
P-P thru 12µH inductor, 5Hz to 20MHz
120 Hz
Vin=48V, Io=Io.max, Tc=25°C
Io=Io, min to Io, max
Vin=36V to 75V
Tc=-40°C to 125°C
Over sample load, line and temperature
5Hz to 20MHz bandwidth
Full Load, 1µF ceramic, 10µF tantalum
Full Load, 1µF ceramic, 10µF tantalum
Output Voltage 10% Low
Max.
Units
80
100
85
125
1500
Vdc
Vdc
°C
°C
Vdc
75
Vdc
35.5
33.5
3
2.2
50
12
1
Vdc
Vdc
Vdc
A
mA
mA
2
As
20
mA
dB
1.015
Vdc
1.03
mV
mV
mV
V
120
50
50
140
mV
mV
A
%
-60
0.985
1.0
±5
±5
±10
0.97
80
20
0
110
48V, 10µF Tan & 1µF Ceramic load cap, 0.1A/µs
50% Io.max to 75% Io.max
75% Io.max to 50% Io.max
Cap ESR>=3mohm;
Full load; 5% overshoot of Vout at startup;
50
50
100
mV
mV
us
15
15
25
25
ms
ms
0
10000
µF
Vin=48V
Vin=48V
84
85
%
%
1500
1000
Vdc
MΩ
pF
250
kHz
10
Von/off
Von/off
0
2.4
0.8
5
V
V
Von/off
Von/off
Max rated current guaranteed at full trim range
Max rated current guaranteed at full remote
sense range
Over full temp range; % of nominal Vout
0
2.4
-20
0.8
5
10
V
V
%
10
%
Per Telecordia SR-332 Issue 2, 80% load, 25°C,
48Vin, 300LFM
Weight
Without heat spreader
Weight
With heat spreader
Refer to Figure 19 for Hot spot 1 location
Over-Temperature Shutdown ( Without heat spreader)
(48Vin,80% Io, 200LFM,Airflow from Vin+ to Vo+)
Refer to Figure 21 for Hot spot 2 location
Over-Temperature Shutdown
(With heat spreader)
(48Vin,80% Io, 200LFM,Airflow from Vin+ to Vo+)
Over-Temperature Shutdown ( NTC resistor )
Refer to Figure 19 for NTC resistor location
Note: Please attach thermocouple on NTC resistor to test OTP function, the hot spots’ temperature is just for reference.
MTBF
Typ.
150
%
4.3
M hours
13.3
21.5
grams
grams
129
°C
122
°C
125
°C
2
ELECTRICAL CHARACTERISTICS CURVES
7
48Vin
EFFICIENCY(%)
82
36Vin
75Vin
79
76
73
1
1
85
6
POWER DISSIPATION(W)
88
5
4
36Vin
3
2
75Vin
1
70
48Vin
0
5
10
15
20
25
30
35
40
45
50
5
OUTPUT CURRENT(A)
10
15
20
25
30
35
40
45
50
OUTPUT CURRENT(A)
Figure 1: Efficiency vs. load current for minimum, nominal, and
maximum input voltage at 25°C
Figure 2: Power dissipation vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
1
2.1
INPUT CURRENT (A)
1.8
1.5
1.2
0.9
0.6
0.3
0
25
30
35
40
45
50
55
60
65
70
75
INPUT VOLTAGE (V)
Figure 3: Typical full load input characteristics at room
temperature
DS_V48SH1R050_10282013
3
ELECTRICAL CHARACTERISTICS CURVES
For Negative Remote On/Off Start up
0
0
0
0
Figure 4: Turn-on transient at full rated load current (10
ms/div). Vin=48V. Top Trace: Vout, 0.5V/div; Bottom Trace:
ON/OFF input, 5V/div
Figure 5: Turn-on transient at zero load current (10 ms/div).
Vin=48V. Top Trace: Vout: 0.5V/div, Bottom Trace: ON/OFF
input, 5V/div
For Input Voltage Start up
0
0
0
0
Figure 6: Turn-on transient at full rated load current (10
ms/div). Vin=48V. Top Trace: Vout, 0.5V/div; Bottom Trace: Vin,
20V/div
Figure 7: Turn-on transient at zero load current (10 ms/div).
Vin=48V. Top Trace: Vout, 0.5V/div; Bottom Trace: Vin, 20V/div
0
0
Figure 8: Output voltage response to step-change in load
current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap:
10µF tantalum capacitor and 1µF ceramic capacitor. Top Trace:
Vout (50mV/div, 500us/div), Bottom Trace: Iout (10A/div).
Scope measurement should be made using a BNC cable
(length shorter than 20 inches). Position the load between 51
mm to 76 mm (2 inches to 3 inches) from the module
DS_V48SH1R050_10282013
4
ELECTRICAL CHARACTERISTICS CURVES
is
ic
Vin+
+
0
+
Vin-
Cs: 220uF
100uF,
ESR=0.2 ohm @
25oC 100KHz
Figure 9: Test set-up diagram showing measurement points for
Input Terminal Ripple Current and Input Reflected Ripple
Current.
Note: Measured input reflected-ripple current with a simulated
source Inductance (LTEST) of 12 μH. Capacitor Cs offset
possible battery impedance. Measure current as shown above
Figure 10: Input Terminal Ripple Current, ic, at full rated output
current and nominal input voltage with 12µH source impedance
and 33µF electrolytic capacitor (200 mA/div, 1us/div)
Copper
Strip
Vo(+)
0
10u
1u
SCOPE
RESISTIVE
LOAD
Vo(-)
Figure 11: Input reflected ripple current, is, through a 12µH
source inductor at nominal input voltage and rated load current
(20 mA/div, 1us/div)
Figure 12: Output voltage noise and ripple measurement test
setup
0
Figure 13: Output voltage ripple at nominal input voltage and
rated load current (50 mV/div, 1us/div)
Load capacitance: 1µF ceramic capacitor and 10µF tantalum
capacitor. Bandwidth: 20 MHz. Scope measurements should be
made using a BNC cable (length shorter than 20 inches).
Position the load between 51 mm to 76 mm (2 inches to 3
inches) from the module.
DS_V48SH1R050_10282013
5
Safety Considerations
DESIGN CONSIDERATIONS
Input Source Impedance
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules and
affect the stability. A low ac-impedance input source is
recommended. If the source inductance is more than a
few μH, we advise adding a 100 μF electrolytic capacitor
(ESR < 0.7 Ω at 100 kHz) mounted close to the input of
the module to improve the stability.
Layout and EMC Considerations
Delta’s DC/DC power modules are designed to operate in
a wide variety of systems and applications. For design
assistance with EMC compliance and related PWB layout
issues, please contact Delta’s technical support team. An
external input filter module is available for easier EMC
compliance design. Below is the reference design for an
input filter tested with V48SH1R050 series to meet class
B in CISSPR 22.
Schematic and Components List:
The power module must be installed in compliance with
the spacing and separation requirements of the
end-user’s safety agency standard, i.e., UL60950-1,
CSA C22.2 NO. 60950-1 2nd and IEC 60950-1 2nd :
2005 and EN 60950-1 2nd: 2006+A11+A1: 2010, if the
system in which the power module is to be used must
meet safety agency requirements.
Basic insulation based on 75 Vdc input is provided
between the input and output of the module for the
purpose of applying insulation requirements when the
input to this DC-to-DC converter is identified as TNV-2
or SELV. An additional evaluation is needed if the
source is other than TNV-2 or SELV.
When the input source is SELV circuit, the power module
meets SELV (safety extra-low voltage) requirements. If
the input source is a hazardous voltage which is greater
than 60 Vdc and less than or equal to 75 Vdc, for the
module’s output to meet SELV requirements, all of the
following must be met:

The input source must be insulated from the ac
mains by reinforced or double insulation.

The input terminals of the module are not operator
accessible.

A SELV reliability test is conducted on the system
where the module is used, in combination with the
module, to ensure that under a single fault,
hazardous voltage does not appear at the module’s
output.
When installed into a Class II equipment (without
grounding), spacing consideration should be given to
the end-use installation, as the spacing between the
module and mounting surface have not been evaluated.
Cin is 100uF low ESR Aluminum cap:
CY is 1nF ceramic cap
CX is 3.3uF ceramic cap:
CY1 is 3.3nF ceramic cap:
CY2 is 3.3nF ceramic cap:
L1 is common-mode inductor ,L1=1mH:
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
Test Result:Vin=48V,Io=50A,
dBμV
80.0
Limits
55022MQP
55022MAV
70.0
This power module is not internally fused. To achieve
optimum safety and system protection, an input line fuse
is highly recommended. The safety agencies require a
Fast-acting fuse with 20A maximum rating to be
installed in the ungrounded lead. A lower rated fuse can
be used based on the maximum inrush transient energy
and maximum input current.
60.0
Soldering and Cleaning Considerations
50.0
40.0
Transducer
LISNPUL
Traces
PK+
AV
30.0
20.0
10.0
0.0
150 kHz
1 MHz
10 MHz
30 MHz
Post solder cleaning is usually the final board assembly
process before the board or system undergoes electrical
testing. Inadequate cleaning and/or drying may lower the
reliability of a power module and severely affect the
finished circuit board assembly test. Adequate cleaning
and/or drying is especially important for un-encapsulated
and/or open frame type power modules. For assistance
on appropriate soldering and cleaning procedures,
please contact Delta’s technical support team.
Blue Line is quasi peak mode;green line is average mode.
DS_V48SH1R050_10282013
6
FEATURES DESCRIPTIONS
Over-Current Protection
The modules include an internal output over-current
protection circuit, which will endure current limiting for an
unlimited duration during output overload. If the output
current exceeds the OCP set point, the modules will
automatically shut down, and enter hiccup mode or latch
mode, the default is hiccup mode.
Remote on/off can be controlled by an external switch
between the on/off terminal and the Vi(-) terminal. The
switch can be an open collector or open drain.
For negative logic if the remote on/off feature is not used,
please short the on/off pin to Vi(-). For positive logic if the
remote on/off feature is not used, please leave the on/off
pin floating.
For hiccup mode, the module will try to restart after
shutdown. If the over current condition still exists, the
module will shut down again. This restart trial will continue
until the over-current condition is corrected.
Vi(+)
Vo(+)
Sense(+)
ON/OFF
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Sense(-)
Vi(-)
Vo(-)
Over-Voltage Protection
The modules include an internal output over-voltage
protection circuit, which monitors the voltage on the
output terminals. If this voltage exceeds the over-voltage
set point, the module will shut down, and enter in hiccup
mode or latch mode, The default is hiccup mode.
For hiccup mode, the module will try to restart after
shutdown. If the over voltage condition still exists, the
module will shut down again. This restart trial will continue
until the over-voltage condition is corrected.
Figure 14: Remote on/off implementation
Remote Sense
Remote sense compensates for voltage drops on the
output by sensing the actual output voltage at the point
of load. The voltage between the remote sense pins and
the output terminals must not exceed the output voltage
sense range given here:
[Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] ≤ 10% × Vout
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Over-Temperature Protection
This limit includes any increase in voltage due to remote
sense compensation and output voltage set point
adjustment (trim).
The over-temperature protection consists of circuitry that
provides protection from thermal damage. If the
temperature exceeds the over-temperature threshold the
module will shut down, and enter in auto-restart mode or
latch mode, the default is auto-restart mode.
For auto-restart mode, the module will monitor the module
temperature after shutdown. Once the temperature is
dropped and within the specification, the module will be
auto-restart.
Vi(+)
Vo(+)
Sense(+)
Sense(-)
Vi(-)
Contact
Resistance
Vo(-)
Contact and Distribution
Losses
For latch mode, the module will latch off once it shutdown.
The latch is reset by either cycling the input power or by
toggling the on/off signal for one second.
Figure 15: Effective circuit configuration for remote sense
operation
Remote On/Off
If the remote sense feature is not used to regulate the
output at the point of load, please connect SENSE(+) to
Vo(+) and SENSE(–) to Vo(–) at the module.
The remote on/off feature on the module can be either
negative or positive logic. Negative logic turns the module
on during a logic low and off during a logic high. Positive
logic turns the modules on during a logic high and off
during a logic low.
DS_V48SH1R050_10282013
The output voltage can be increased by both the remote
sense and the trim; however, the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
7
FEATURES DESCRIPTIONS (CON.)
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Max rated current is guaranteed at full output voltage
remote sense range.
Output Voltage Adjustment (TRIM)
To increase or decrease the output voltage set point,
connect an external resistor between the TRIM pin and
either the SENSE(+) or SENSE(-). The TRIM pin
should be left open if this feature is not used.
Figure 17: Circuit configuration for trim-up (increase output
voltage)
If the external resistor is connected between the TRIM
and SENSE (+) the output voltage set point increases
(Fig. 19). The external resistor value required to obtain
a percentage output voltage change △% is defined
as:
Rtrim  up 
5.11Vo (100   ) 511

 10.22K 
0.6

Ex. When Trim-up +10% (1.0V×1.1=1.1V)
5.11 1.0  (100  10) 511

 10.22  32.36K 
0.6  10
10
Figure 16: Circuit configuration for trim-down (decrease
output voltage)
Rtrim  up 
If the external resistor is connected between the TRIM
and SENSE (-) pins, the output voltage set point
decreases (Fig. 18). The external resistor value
required to obtain a percentage of output voltage
change △% is defined as:
Trim resistor can also be connected to Vo+ or Vo- but it
would introduce a small error voltage than the desired
value.
 511

Rtrim  down  
 10.22 K 


Ex. When Trim-down -10% (1.0V×0.9=0.9V)
 511

Rtrim  down  
 10.22 K   40.88K 
 10

The output voltage can be increased by both the remote
sense and the trim, however the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Max rated current is guaranteed at full output voltage
trim range.
DS_V48SH1R050_10282013
8
THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
PWB
FANCING PWB
MODULE
50.8(2.00")
AIR VELOCITY
AND AMBIENT
TEMPERATURE
SURED BELOW
THE MODULE
AIR FLOW
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 18: Wind tunnel test setup
Thermal Derating
Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power module
should always be operated below the maximum
operating temperature. If the temperature exceeds the
maximum module temperature, reliability of the unit may
be affected.
DS_V48SH1R050_10282013
9
THERMAL CURVES
(WITHOUT HEAT SPREADER)
THERMAL CURVES
(WITH HEAT SPREADER)
HOT SPOT1
HOT SPOT2
AIRFLOW
AIRFLOW
NTC RESISTOR
Figure 19: * Hot spot 1& NTC resistor temperature measured
points
Output Current (A)
Figure 21: * Hot spot 2 temperature measured point
V48SH1R050(Standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 48V (Either Orientation)
50
Output Current (A)
V48SH1R050(Standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 48V (Either Orientation; With Heatspreader)
50
45
45
Natural
Convection
40
Natural
Convection
40
100LFM
35
30
100LFM
35
200LFM
200LFM
30
300LFM
400LFM
25
400LFM
500LFM
500LFM
20
300LFM
25
20
600LFM
600LFM
15
15
10
10
5
5
0
0
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (℃)
Figure 20: Output current vs. ambient temperature and air
velocity @Vin=48V(Either Orientation, airflow from Vin+ to
Vout+, without heat spreader)
DS_V48SH1R050_10282013
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (℃)
Figure 22: Output current vs. ambient temperature and air velocity
@Vin=48V(Either Orientation, airflow from Vin+ to Vout+, with heat
spreader)
10
PICK AND PLACE LOCATION
RECOMMENDED PAD LAYOUT (SMD)
SURFACE-MOUNT TAPE & REEL
DS_V48SH1R050_10282013
11
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE(for SMD models)
Note: The temperature refers to the pin of V48SH, measured on the pin +Vout joint.
LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE(for SMD models)
Temp.
Peak Temp. 240 ~ 245 ℃
217℃
Ramp down
max. 4℃/sec.
200℃
Preheat time
100~140 sec.
150℃
Time Limited 90 sec.
above 217℃
Ramp up
max. 3℃/sec.
25℃
Time
Note: The temperature refers to the pin of V48SH, measured on the pin +Vout joint.
DS_V48SH1R050_10282013
12
MECHANICAL DRAWING(WITH HEAT-SPREADER)
* For modules with through-hole pins and the optional heatspreader, they are intended for wave soldering assembly
onto system boards; please do not subject such modules through reflow temperature profile.
DS_V48SH1R050_10282013
13
MECHANICAL DRAWING (WITHOUT HEAT-SPREADER)
Surface-mount module
Pin No.
1
2
3
4
5
6
7
8
Name
+Vin
ON/OFF
-Vin
-Vout
-Sense
Trim
+Sense
+Vout
Through-hole module
Function
Positive input voltage
Remote ON/OFF
Negative input voltage
Negative output voltage
Negative remote sense
Output voltage trim
Positive remote sense
Positive output voltage
Pin Specification:
Pins 1-3,5-7
Pins 4 & 8
1.00mm (0.040”) diameter
2. 1.50mm (0.060”) diameter
All pins are copper alloy with matte-tin(Pb free) plated over Nickel under-plating.
DS_V48SH1R050_10282013
14
RECOMMENDED PAD LAYOUT (FOR THROUGH-HOLE MODULE)
DS_V48SH1R050_10282013
15
PART NUMBERING SYSTEM
V
48
Type of
Product
V - 1/16
Brick
S
H
1R0
50
N
R
Input Number of
Voltage Outputs
Product
Series
Output
Voltage
Output
Current
ON/OFF
Logic
Pin
Length/Type
4836V~75V
H - High
Power
1R0 - 1.0V
50 - 50A
N- Negative
P- Positive
R - 0.170”
N - 0.145”
K - 0.110”
M-SMD
S - Single
F
A
Option Code
F- RoHS 6/6 A - Standard Functions
(Lead Free) H - with Heatspreader
MODEL LIST
MODEL NAME
V48SH1R050NNFA
INPUT
36V~75V
OUTPUT
2.2A
1.0V
EFF @ 100% LOAD
50A
84%
Default remote on/off logic is negative and pin length is 0.170”
For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office.
For modules with through-hole pins and the optional heatspreader, they are intended for wave soldering assembly onto system boards;
please do not subject such modules through reflow temperature profile.
CONTACT: www.deltaww.com/dcdc
USA:
Telephone:
East Coast: 978-656-3993
West Coast: 510-668-5100
Fax: (978) 656 3964
Email: [email protected]
Europe:
Phone: +31-20-655-0967
Fax: +31-20-655-0999
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107
Ext 6220~6224
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its
use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications
at any time, without notice.
DS_V48SH1R050_10282013