FEATURES High efficiency: 90.5% @ 12V/ 5A Size: 58.4mmx22.8mmx10.0mm (2.30”x0.90”x0.39”) SMD and Through-hole versions Industry standard pin out 2:1 input range Fixed frequency operation Input UVLO, Output OTP, OCP, OVP Basic insulation 2250V isolation Monotonic startup into normal and pre-biased loads Output voltage trim:±10% No minimum load required ISO 9001, TL 9000, ISO 14001, QS 9000, OHSAS 18001 certified manufacturing facility UL/cUL 60950-1 (US & Canada) recognized Delphi Series E24SR, 66W Eighth Brick Family DC/DC Power Modules: 24V in, 12V/5A out The Delphi Series E24SR Eighth Brick, 24V input, single output, isolated DC/DC converters are the latest offering from a world leader in power systems technology and manufacturing ― Delta Electronics, Inc. This product family is available in either a through-hole or surface-mounted OPTIONS Positive On/Off logic SMD pin Short pin lengths available package and provides up to 66 watts of power or 20A of output current (3.3V and below) in an industry standard footprint and pinout. The E24SR converter operates from an input voltage of 18V to 36V and is available in output voltages from 3.3V to 12V. Efficiency for the 12V output is 90.5% at 5A full load. With creative design technology and optimization of component placement, these converters possess outstanding electrical and thermal performance, as well as extremely APPLICATIONS high reliability under highly stressful operating conditions. All models are Telecom / DataCom fully protected from abnormal input/output voltage, current, and Wireless Networks temperature conditions. The Delphi Series converters meet all safety Optical Network Equipment requirements with basic insulation. Server and Data Storage Industrial / Test Equipment DATASHEET DS_E24SR12005_10282013 TECHNICAL SPECIFICATIONS (TA=25°C, airflow rate=300 LFM, Vin=24 Vdc, nominal Vout unless otherwise noted.) PARAMETER NOTES and CONDITIONS E24SR12005 (Standard) Min. ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous Transient (100ms) Operating Temperature Storage Temperature Input/Output Isolation Voltage INPUT CHARACTERISTICS Operating Input Voltage Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Hysteresis Voltage Maximum Input Current No-Load Input Current Off Converter Input Current 2 Inrush Current (I t) Input Reflected-Ripple Current Input Voltage Ripple Rejection OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Load Over Line Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output Over Current Protection DYNAMIC CHARACTERISTICS Output Voltage Current Transient Positive Step Change in Output Current Negative Step Change in Output Current Settling Time (within 1% Vout nominal) Turn-On Transient Start-Up Time, From On/Off Control Start-Up Time, From Input Back bias start-up Back drive current limit while pin on-off is enabled Back drive current limit while pin on-off is disabled Maximum Output Capacitance EFFICIENCY 100% Load 60% Load ISOLATION CHARACTERISTICS Input to Output Isolation Resistance Isolation Capacitance FEATURE CHARACTERISTICS Switching Frequency ON/OFF Control, Negative Remote On/Off logic Logic Low (Module On) Logic High (Module Off) ON/OFF Control, Positive Remote On/Off logic Logic Low (Module Off) Logic High (Module On) On/off pin open circuit voltage On/off pin pull down resistance Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection GENERAL SPECIFICATIONS MTBF Weight Over-Temperature Shutdown DS_E24SR12005_10282013 Typ. Max. Units 36 50 117 125 2250 Vdc Vdc °C °C Vdc 36 Vdc 17.8 17 1.5 3.8 180 10 0.1 Vdc Vdc Vdc A mA mA 2 As mA dB 12 12.18 Vdc ±3 ±3 ±100 ±10 ±10 12.24 mV mV mV V 50 15 100 30 5 140 mV mV A % 180 180 150 250 250 mV mV us 100ms Refer to figure 21 for measuring point -55 18 16 15 0.7 17 16 1 100% Load, 18Vin 150 3 P-P thru 12µH inductor, 5Hz to 20MHz 120 Hz Vin=24V, Io=Io.max, Tc=25°C Io=Io, min to Io, max Vin=18V to36V Tc=-40°C to100°C Over sample load, line and temperature 5Hz to 20MHz bandwidth Full Load, 1µF ceramic, 10µF tantalum Full Load, 1µF ceramic, 10µF tantalum Output Voltage 10% Low 10 55 11.82 11.76 0 110 10µF Tan & 1µF Ceramic load cap, 0.1A/µs 50% Io.max to 75% Io.max 75% Io.max to 50% Io.max 5 5 90% of nominal output voltage Io=0A Io=0A Full load; 5% overshoot of Vout at startup ms ms 0.1 50 2000 90.5 90 % % 2250 1500 Vdc MΩ pF 350 kHz 10 Pout ≦ max rated power Pout ≦ max rated power Over full temp range; Io=80% of Io, max; Ta=25°C, 300LFM airflow Refer to figure 21 for measuring point A mA µF -0.7 3 0.5 18 V V -0.7 3 0.5 18 9.6 V V V Kohm % % V 12 -10 +10 +10 16.8 13.8 2.81 22.0 130 M hours grams °C 2 ELECTRICAL CHARACTERISTICS CURVES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum input voltage at 25°C Figure 2: Power dissipation vs. load current for minimum, nominal, and maximum input voltage at 25°C. 4.0 3.5 Inputt Current(A) 3.0 2.5 2.0 1.5 1.0 0.5 0.0 18 20 22 24 26 28 30 32 34 36 INPUT VOLTAGE (V) Figure 3: Typical full load input characteristics at room temperature DS_E24SR12005_10282013 3 ELECTRICAL CHARACTERISTICS CURVES For Negative Remote On/Off Logic 0 0 0 0 Figure 4: Turn-on transient at full rated load current (resistive load) (2 ms/div). Vin=24V. Top Trace: Vout, 5.0V/div; Bottom Trace: ON/OFF input, 10V/div Figure 5: Turn-on transient at zero load current (2 ms/div). Vin=24V. Top Trace: Vout: 5.0V/div, Bottom Trace: ON/OFF input, 10V/div For Positive Remote On/Off Logic 0 0 0 0 Figure 6: Turn-on transient at full rated load current (resistive load) (2 ms/div). Vin=24V. Top Trace: Vout, 5.0V/div; Bottom Trace: ON/OFF input, 10V/div DS_E24SR12005_10282013 Figure 7: Turn-on transient at zero load current (2 ms/div). Vin=24V Top Trace: Vout, 5.0V/div; Bottom Trace: ON/OFF input, 10V/div 4 ELECTRICAL CHARACTERISTICS CURVES 0 0 Hot Hot spot spot 0 0 Figure 8: Output voltage response to step-change in load current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF tantalum capacitor and 1µF ceramic capacitor. Top Trace: Vout (100mV/div, 200us/div), Bottom Trace: Iout (2A/div). Scope measurement should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module Hot Figure 9: Output voltage response to step-change in load spot current (75%-50%-75% of Io, max; di/dt = 1A/µs). Load cap: 470µF, 35m ESR solid electrolytic capacitor and 1µF ceramic capacitor. Top Trace: Vout (100mV/div, 200us/div), Bottom Trace: Iout (2A/div). Scope measurement should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module 0 Figure 10: Test set-up diagram showing measurement points for Input Terminal Ripple Current and Input Reflected Ripple Current. Note: Measured input reflected-ripple current with a simulated source Inductance (LTEST) of 12 μH. Capacitor Cs offset possible battery impedance. Measure current as shown above DS_E24SR12005_10282013 Figure 11: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 12µH source impedance and 33µF electrolytic capacitor (200 mA/div, 2us/div) 5 ELECTRICAL CHARACTERISTICS CURVES Copper Strip Vo(+) 0 10u SCOPE 1u RESISTIVE LOAD Vo(-) Figure 12: Input reflected ripple current, is, through a 12µH source inductor at nominal input voltage and rated load current (20 mA/div, 2us/div) Figure 13: Output voltage noise and ripple measurement test setup 14.0 0 Output Voltage (V) 12.0 10.0 8.0 6.0 4.0 2.0 0.0 0 1 2 3 4 5 6 7 8 Load Current (A) Figure 14: Output voltage ripple at nominal input voltage and rated load current (Io=5A)(20 mV/div, 2us/div) Load capacitance: 1µF ceramic capacitor and 10µF tantalum capacitor. Bandwidth: 20 MHz. Scope measurements should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module DS_E24SR12005_10282013 Figure 15: Output voltage vs. load current showing typical current limit curves and converter shutdown points 6 DESIGN CONSIDERATIONS Safety Considerations Input Source Impedance The power module must be installed in compliance with the spacing and separation requirements of the end-user’s safety agency standard, i.e., UL60950, CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and IEC60950-1999, if the system in which the power module is to be used must meet safety agency requirements. Basic insulation based on 75 Vdc input is provided between the input and output of the module for the purpose of applying insulation requirements when the input to this DC-to-DC converter is identified as TNV-2 or SELV. An additional evaluation is needed if the source is other than TNV-2 or SELV. When the input source is SELV circuit, the power module meets SELV (safety extra-low voltage) requirements. If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 75 Vdc for the module’s output to meet SELV requirements, all of the following must be met: The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded, one Vi pin and one Vo pin shall also be grounded. A SELV reliability test is conducted on the system where the module is used, in combination with the module, to ensure that under a single fault, hazardous voltage does not appear at the module’s output. When installed into a Class II equipment (without grounding), spacing consideration should be given to the end-use installation, as the spacing between the module and mounting surface have not been evaluated. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. The impedance of the input source connecting to the DC/DC power modules will interact with the modules and affect the stability. A low ac-impedance input source is recommended. If the source inductance is more than a few μH, we advise adding a 10 to 100 μF electrolytic capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the input of the module to improve the stability. Layout and EMC Considerations Delta’s DC/DC power modules are designed to operate in a wide variety of systems and applications. For design assistance with EMC compliance and related PWB layout issues, please contact Delta’s technical support team. An external input filter module is available for easier EMC compliance design. Below is the reference design for an input filter tested with E24SR12005XXXX to meet class B in CISSPR 22. Schematic and Components List Cin is 100uF*2 low ESR Aluminum cap; CX is 2.2uF ceramic cap; CY1 are 10nF ceramic caps; CY2 are 10nF ceramic caps; CY is 1nF ceramic cap; L1 is common-mode inductor, L1=0.53mH; Test Result: Vin=24V, Io=5A, This power module is not internally fused. To achieve optimum safety and system protection, an input line fuse is highly recommended. The safety agencies require a normal-blow fuse with 15A maximum rating to be installed in the ungrounded lead. A lower rated fuse can be used based on the maximum inrush transient energy and maximum input current. Soldering and Cleaning Considerations Yellow line is quasi peak mode; Blue line is average mode DS_E24SR12005_10282013 Post solder cleaning is usually the final board assembly process before the board or system undergoes electrical testing. Inadequate cleaning and/or drying may lower the reliability of a power module and severely affect the finished circuit board assembly test. Adequate cleaning and/or drying is especially important for un-encapsulated and/or open frame type power modules. For assistance on appropriate soldering and cleaning procedures, please contact Delta’s technical support team. 7 FEATURES DESCRIPTIONS Vo(+) Vi(+) Over-Current Protection Sense(-) The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modules will automatically shut down, and enter hiccup mode. The modules will try to restart after shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is corrected. Over-Voltage Protection The modules include an internal output over-voltage protection circuit, which monitors the voltage on the output terminals. If this voltage exceeds the over-voltage set point, the module will shut down (Hiccup mode). The modules will try to restart after shutdown. If the fault condition still exists, the module will shut down again. This restart trial will continue until the fault condition is corrected. Sense(-) Vo(-) Vi(-) Figure 16: Remote on/off implementation Remote Sense Remote sense compensates for voltage drops on the output by sensing the actual output voltage at the point of load. The voltage between the remote sense pins and the output terminals must not exceed the output voltage sense range given here: [Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] ≤ 10% × Vout This limit includes any increase in voltage due to remote sense compensation and output voltage set point adjustment (trim). Over-Temperature Protection Vi(+) The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the over-temperature threshold the module will shut down. Trim ON/OFF Vo(+) Sense(-) ON/OFF R Trim Load Sense(-) The module will try to restart after shutdown. If the over-temperature condition still exists during restart, the module will shut down again. This restart trial will continue until the temperature is within specification. Remote On/Off The remote on/off feature on the module can be either negative or positive logic. Negative logic turns the module on during a logic low and off during a logic high. Positive logic turns the modules on during a logic high and off during a logic low. Remote on/off can be controlled by an external switch between the on/off terminal and the Vi(-) terminal. The switch can be an open collector or open drain. For negative logic if the remote on/off feature is not used, please short the on/off pin to Vi(-). For positive logic if the remote on/off feature is not used, please leave the on/off pin floating. Vi(-) Vo(-) Distribution resistance Figure 17: Effective circuit configuration for remote sense operation If the remote sense feature is not used to regulate the output at the point of load, please connect SENSE(+) to Vo(+) and SENSE(–) to Vo(–) at the module. The output voltage can be increased by both the remote sense and the trim; however, the maximum increase is the larger of either the remote sense or the trim, not the sum of both. When using remote sense and trim, the output voltage of the module is usually increased, which increases the power output of the module with the same output current. Care should be taken to ensure that the maximum output power does not exceed the maximum rated power. DS_E24SR12005_10282013 8 FEATURES DESCRIPTIONS (CON.) Output Voltage Adjustment (TRIM) To increase or decrease the output voltage set point, connect an external resistor between the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used. Figure 19: Circuit configuration for trim-up (increase output voltage) Figure 18: Circuit configuration for trim-down (decrease output voltage) If the external resistor is connected between the TRIM and SENSE (-) pins, the output voltage set point decreases (Fig. 18). The external resistor value required to obtain a percentage of output voltage change △% is defined as: 511 Rtrim down 10.2 K If the external resistor is connected between the TRIM and SENSE (+) the output voltage set point increases (Fig. 19). The external resistor value required to obtain a percentage output voltage change △% is defined as: Rtrim up Ex. When Trim-up +10% (12V×1.1=13.2V) Ex. When Trim-down -10% (12V×0.9=10.8V) 511 Rtrim down 10.2 K 40.9K 10 5.11Vo (100 ) 511 10.2K 1.225 Rtrim up 5.11 12 (100 10) 511 10.2 489.3K 1.225 10 10 The output voltage can be increased by both the remote sense and the trim, however the maximum increase is the larger of either the remote sense or the trim, not the sum of both. When using remote sense and trim, the output voltage of the module is usually increased, which increases the power output of the module with the same output current. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. DS_E24SR12005_10282013 9 THERMAL CONSIDERATIONS Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer. Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel. Thermal Derating Heat can be removed by increasing airflow over the module. To enhance system reliability, the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected. THERMAL CURVES Thermal Testing Setup Delta’s DC/DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted. The following figure shows the wind tunnel characterization setup. The power module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is constantly kept at 6.35mm (0.25’’). Figure 21: Hot spot temperature measured point The allowed maximum hot spot temperature is defined at 117℃ Output Current(A) E24SR12005(Standard) Output Current vs. Ambient Temperature and Air Velocity @Vin = 24V (Transverse Orientation) 5 Natural Convection PWB FACING PWB MODULE 4 100LFM 3 200LFM 2 AIR VELOCITY AND AMBIENT TEMPERATURE MEASURED BELOW THE MODULE 1 50.8 (2.0”) 0 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (℃) AIR FLOW Figure 22: Output current vs. ambient temperature and air velocity @Vin=24V (Transverse Orientation) 12.7 (0.5”) Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches) Figure 20: Wind tunnel test setup figure DS_E24SR12005_10282013 10 PICK AND PLACE LOCATION SURFACE-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD) DS_E24SR12005_10282013 11 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE Note: The temperature refers to the pin of E24SR, measured on the pin +Vout joint. LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE Temp. Peak Temp. 240 ~ 245 ℃ 217℃ Ramp down max. 4℃/sec. 200℃ Preheat time 100~140 sec. 150℃ Time Limited 90 sec. above 217℃ Ramp up max. 3℃/sec. 25℃ Time Note: The temperature refers to the pin of E24SR, measured on the pin +Vout joint. DS_E24SR12005_10282013 12 MECHANICAL DRAWING Surface-mount module Pin No. 1 2 3 4 5 6 7 8 Name -Vin ON/OFF +Vin +Vout +SENSE TRIM -SENSE -Vout DS_E24SR12005_10282013 Through-hole module Function Negative input voltage Remote ON/OFF Positive input voltage Positive output voltage Positive remote sense Output voltage trim Negative remote sense Negative output voltage 13 PART NUMBERING SYSTEM E 24 S R 120 05 N R Type of Product Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Length/Type S - Single R - Regular 120 - 12V 05 - 05A N - Negative P - Positive E - Eighth 24-18V~36V Brick R - 0.170” N - 0.145” K - 0.110” M - SMD F A Option Code F- RoHS 6/6 (Lead Free) A - Standard Functions MODEL LIST MODEL NAME E24SR06508NRFA E24SR12005NRFA INPUT 18V~36V 18V~36V OUTPUT 3.4A 4A 6.5V 12V EFF @ 100% LOAD 8A 5A 90.5% 90.5% Default remote on/off logic is negative and pin length is 0.170” For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office. CONTACT: www.deltaww.com/dcdc USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964 Email: [email protected] Europe: Phone: +31-20-655-0967 Fax: +31-20-655-0999 Email: [email protected] Asia & the rest of world: Telephone: +886 3 4526107 x 6220~6224 Fax: +886 3 4513485 Email: [email protected] WARRANTY Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. DS_E24SR12005_10282013 14