HA1SV15007 100W DC/DC Power Modules FEATURES High efficiency : 88.5% @110Vin full load Size:61.0mm*57.9mm*12.7mm(2.4’’ *2.28’’ *0.5’’) Industry standard pin out and footprint Fixed frequency operation Input UVP/ OVP Hiccup output over current protection (OCP) Hiccup output over voltage protection (OVP) Output current limited protection(OCL) Auto recovery OTP Monotonic startup into normal 3000V isolation and reinforce insulation No minimum load required ISO 9001, TL 9000, ISO 14001, QS9000, OHSAS18001 certified manufacturing facility Delphi Series HA1SV15, half Brick Family DC/DC Power Modules: 53~154V in, 15V/6.7A out, 100W EN61373,EN50155 EN60950-1 APPLICATIONS Railway /Transportation system The Delphi Module HA1SV15007PRFA, half brick, 53~154V input, single output, isolated DC/DC converter is the latest offering from a world leader in power system and technology and manufacturing ― Delta Electronics, Inc. This product provides up to 100 watts power in an industry standard footprint and pin out. With creative design technology and optimization of component placement, these converters possess outstanding electrical and thermal performances, as well as extremely high reliability under highly stressful operating conditions. The HA1SV15007PRFA offers more than 86.5% high efficiency at 5A load in all input voltage range. DS_HA1SV15007_ 01282015 E-mail: [email protected] http://www.deltaww.com/dcdc P1 TECHNICAL SPECIFICATIONS PARAMETER 1.ABSOLUTE MAXIMUM RATINGS 1.1 Input Voltage 1.2 Input surge withstand 1.3 Operating Ambient Temperature 1.4 Storage Temperature 1.5 Input/Output Isolation Voltage 2. INPUT CHARACTERISTICS 2.1 Operating Input Voltage 2.2 Input Under-Voltage Lockout 2.2.1 Turn-On Voltage Threshold 2.2.2 Turn-Off Voltage Threshold 2.2.3 Input Over-Voltage Lockout 2.2.4 Turn-On Voltage Threshold 2.2.5 Turn-Off Voltage Threshold 2.3 Operating Input Current 2.3.1 Off Converter Input Current 2.3.2 no load input current 2.3.3 maximum input current 2.3.4 Input Reflected-Ripple Current(pk-pk) NOTES and CONDITIONS EN50155 HA1SV15007PRFA Min. Typ. Max. Units 53 110 154 250 100 125 3000 Vdc Vdc °C °C Vrms 53 110 154 Vdc 49 46 51 48 53 51 Vdc Vdc 154 159 158 162 161 166 Vdc Vdc 18.8 21.5 2.2 21 30 2.3 mA mA A <100ms -40 -55 reinforce Vin=110V Vin=110V, Io=0A Vin=53V, Io=6.7A Vin=110V, Io=full load Cin=150uF/400V 340 mA 3 OUTPUT CHARACTERISTICS 3.1 Output Voltage Set Point Vin=110V, Io=0, Tc=25°C 15 15.15 Vdc 3.1.1 Load regulation 3.1.2 Line regulation Vin=110V, Io=Io min to Io max Vin=53V to154V, Io=full load ±0.05 ±0.01 % % Vin=110V, Tc= min to max case temperatrue ±0.004 ±0.2 ±0.2 ± 0.007 5Hz to 20MHz bandwidth Full Load, Full Load, 50 10 3.1.3 Temperature regulation 3.2 Output Voltage Ripple and Noise 3.2.1 Peak-to-Peak 3.2.2 rms 3.3 Operating Output Current Range 3.4 Output DC Current-Limit Inception 4. DYNAMIC CHARACTERISTICS 4.1 Output Voltage Current Transient 4.2 Positive Step Change in Output Current 4.3 Negative Step Change in Output Current 4.4 Turn-On Transient 4.4.1 Start-Up Time, From On/Off Control 4.4.2 Start-Up Time, From Input 4.4.3 Rise time(Vout from 10% to 90%) 4.5 Maximum output capacitor 5. EFFICIENCY 5.1 100% Load 5.2 60% Load 6. ISOLATION CHARACTERISTICS 6.1 Input to Output 6.2 Input to base 6.3 Output to base 6.4 Isolation Resistance 7. FEATURE CHARACTERISTICS 7.1 Switching Frequency 7.2 ON/OFF Control, Negative Remote On/Off logic 7.2.1 Logic High (Module On) 7.2.2 Logic Low (Module Off) 7.2.3 Output Voltage Trim Range 7.3 Output Over-Voltage Protection 8. GENERAL SPECIFICATIONS 8.1 Weight 8.2 Over-Temperature Shutdown ( NTC resistor ) 8.3 MTBF 14.85 0 7.5 110V, 0.1A/µs 50% Io.max to 75% 75% Io.max to 50% Vin=110V Vin=110V 87 87 8 80 20 6.7 8.5 mV mV A A 200 200 600 600 mV mV 55 50 30 680 100 80 50 ms ms ms µF 88.5 88 % % 3000 1500 500 Over full temp range; % of nominal Vout 3 0 -10 17.5 With heat spreader Refer to Figure 18 for NTC resistor location 115 %/℃ 10 Vrms Vrms Vrms MΩ 300 kHz 80 120 1,302,169 5 1 10 18.5 V V % V 125 grams °C hours (TA=25°C, Natural convection, Vin=110Vdc, nominal Vout unless otherwise noted; DS_HA1SV15007_01282015 E-mail: [email protected] http://www.deltaww.com/dcdc P2 100. 00% 15. 0 90. 00% 13. 5 80. 00% 12. 0 70. 00% 10. 5 60. 00% 50. 00% 110V 40. 00% 53V 30. 00% 154V power l oss ef f i ci ency ELECTRICAL CHARACTERISTICS CURVES 9. 0 7. 5 53V 6. 0 110V 4. 5 154V 20. 00% 3. 0 10. 00% 1. 5 0. 00% 0 1 2 3 4 5 6 7 Out put cur r ent ( A) 0. 0 0 1 2 3 4 5 6 7 Out put cur r ent ( A) Figure 1: Efficiency vs. load current for 53,110and 154 input voltage at 25°C. Figure 2: Power dissipation vs. load current for 66V, 110V, and 160V input voltage at 25°C. Figure 3: Turn-on transient at zero load current) (10ms/div). Top Trace: Vout; 5V/div; Bottom Trace: ON/OFF input: 2V/div. Figure 4: Turn-on transient at full load current (10ms/div). Top Trace: Vout: 5V/div; Bottom Trace: ON/OFF input: 2V/div. Figure 5: Turn-on transient at zero load current (20ms/div). Top Trace: Vout; 5V/div; Bottom Trace: input voltage: 50V/div. Figure 6: Turn-on transient at full load current (20ms/div). Top Trace: Vout; 5V/div; Bottom Trace: input voltage: 50V/div. DS_HA1SV15007_01282015 E-mail: [email protected] http://www.deltaww.com/dcdc P3 ELECTRICAL CHARACTERISTICS CURVES Figure 7: Output voltage response to step-change in load current (50%-75%-50% of full load; di/dt = 0.1A/µs). Bottom Trace: Vout;100mV/div; Time: 1ms/div Figure 8: Output voltage response to step-change in load current (50%-75%-50% of full load; di/dt = 2.5A/µs). Bottom Trace: Vout; 100mV/div; Time: 2ms/div Vo(+) scope r Resistor load Vo(-) Figure 9: Output voltage noise and ripple measurement test setu out put vol t age( V) 16 14 12 10 8 OCL 6 4 2 0 0 1 2 3 4 5 6 7 8 9 Out put cur r ent ( A) Figure 10: Output voltage ripple at nominal input voltage and max load current (10 mV/div, 2us/div) Bandwidth: 200 MHz. DS_HA1SV15007_01282015 Figure 11: Output voltage vs. load current showing typical current limit curves and converter shutdown points. E-mail: [email protected] http://www.deltaww.com/dcdc P4 DESIGN CONSIDERATIONS Input Source Impedance Test Result: At T = +25C , Vin = 110V and full load black line is QP value; The impedance of the input source connecting to the DC/DC power modules will interact with the modules and affect the stability. A low ac-impedance input source is recommended. If the source inductance is more than a few μH, we advise 150μF electrolytic capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the input of the module to improve the stability. Layout and EMC Considerations Delta’s DC/DC power modules are designed to operate in a wide variety of systems and applications. For design assistance with EMC compliance and related PWB layout issues, please contact Delta’s technical support team. Below is the reference design for an input filter tested with HA1SV15007PRFA to meet class A in CISSPR 22. Schematic and Components List Figure 13 EMI test positive line Safety Considerations Figure12 EMI test schematic The power module must be installed in compliance with the spacing and separation requirements of the end-user’s safety agency standard, i.e., UL60950-1, CSA C22.2 NO. 60950-1 2nd and IEC 60950-1 2nd : 2005 and EN 60950-1 2nd: 2006+A11+A1: 2010, if the system in which the power module is to be used must meet safety agency requirements. C121=120Uf/400V C123,C124,C127,C132 =220pF/275VAC C128,C129,C130,C131=2200pF/300VAC C122,C125,C126=0.47uF/250V T1=3.4mH, common choke R110,R111,R112,E113,R114=300kohm/1206 DS_HA1SV15007_01282015 E-mail: [email protected] http://www.deltaww.com/dcdc P5 Basic insulation based on 110 Vdc input is provided between the input and output of the module for the purpose of applying insulation requirements when the input to this DC-to-DC converter is identified as TNV-2 or SELV. An additional evaluation is needed if the source is other than TNV-2 or SELV. When the input source is SELV circuit, the power module meets SELV (safety extra-low voltage) requirements. If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 110 Vdc, for the module’s output to meet SELV requirements, all of the following must be met: The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. A SELV reliability test is conducted on the system where the module is used, in combination with the module, to ensure that under a single fault, hazardous voltage does not appear at the module’s output. When installed into a Class II equipment (without grounding), spacing consideration should be given to the end-use installation, as the spacing between the module and mounting surface have not been evaluated. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. This power module is not internally fused. To achieve optimum safety and system protection, an input line fuse is highly recommended. The safety agencies require a normal-blow fuse with 10A maximum rating to be installed in the ungrounded lead. A lower rated fuse can be used based on the maximum inrush transient energy and maximum input current. Soldering and Cleaning Considerations FEATURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modules will shut down, and will try to restart after shutdown(hiccup mode). If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is corrected. Over-Voltage Protection The modules include an internal output over-voltage protection circuit, which monitors the voltage on the output terminals. If this voltage exceeds the over-voltage set point, the protection circuit will constrain the max duty cycle to limit the output voltage, if the output voltage continuously increases the modules will shut down, and then restart after a hiccup-time (hiccup mode). Over-Temperature Protection The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the over-temperature threshold the module will shut down.The module will restart after the temperature is within specification. Remote On/Off The remote on/off feature on the module can be either negative or positive logic. Negative logic turns the module on during a logic low and off during a logic high. Positive logic turns the modules on during a logic high and off during a logic low. Remote on/off can be controlled by an external switch between the on/off terminal and the Vi (-) terminal. The switch can be an open collector or open drain. For negative logic if the remote on/off feature is not used, please short the on/off pin to Vi (-). For positive logic if the remote on/off feature is not used, please leave the on/off pin to floating. Post solder cleaning is usually the final board assembly process before the board or system undergoes electrical testing. Inadequate cleaning and/or drying may lower the reliability of a power module and severely affect the finished circuit board assembly test. Adequate cleaning and/or drying is especially important for un-encapsulated and/or open frame type power modules. For assistance on appropriate soldering and cleaning procedures, please contact Delta’s technical support team. Figure 14: Remote on/off implementation DS_HA1SV15007_01282015 E-mail: [email protected] http://www.deltaww.com/dcdc P6 Output Voltage Adjustment (TRIM) To increase or decrease the output voltage set point, connect an external resistor between the TRIM pin and SENSE(+) pin or SENSE(-) pin. The TRIM pin should be left open if this feature is not used. For trim down, the external resistor value required to obtain a percentage of output voltage change △% is defined as: 10 *Vnom * (1 ) Rtrim down K 15 15 * (1 ) Ex. When Trim-down -10% (15V×0.9=13.5V) 10 *15 * 0.9 Rtrim down K 90K 15 15 * 0.9 For trim up, the external resistor value required to obtain a percentage output voltage change △% is defined as: Vnom * (1 ) 2.5 60 Rtrim up 10 K Vnom * Ex. When Trim-up +10% (15V×1.1=16.5V) Rtrim up 15 (1 0.1) 2.5 60 10 560K 15 * 0.1 The output voltage can be increased by both the remote sense and the trim, however the maximum increase is the larger of either the remote sense or the trim, not the sum of both. THERMAL CONSIDERATIONS Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer. Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel. Thermal Testing Setup Delta’s DC/DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted. The following figure shows the wind tunnel characterization setup. The power module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is constantly kept at 6.35mm (0.25’’). PWB FANCING PWB MODULE When using remote sense and trim, the output voltage of the module is usually increased, which increases the power output of the module with the same output current. AIR VELOCITY AND AMBIENT TEMPERATURE SURED BELOW THE MODULE 50.8(2.00") Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. AIR FLOW Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches) Figure 15: Wind tunnel test setup Thermal Derating Heat can be removed by increasing airflow over the module. To enhance system reliability, the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected. DS_HA1SV15007_01282015 E-mail: [email protected] http://www.deltaww.com/dcdc P7 THERMAL CURVES THERMAL CURVES HA1SV15007PRFA(Standard) Output Current vs. Ambient Temperature and Air Velocity @Vin = 110V (Transverse Orientation) Output Current (A) 7.5 6.7 5.9 Natural Convection 5.1 100LFM 4.3 200LFM 3.5 300LFM 2.7 400LFM 500LFM 1.9 600LFM 1.1 0.3 25 Figure 16: * temperature measured point DS_HA1SV15007_01282015 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (℃) Figure 17: Output current vs. ambient temperature and air velocity @Vin=110V(Either Orientation, airflow from Vin- to Vin+,with heat spreader) E-mail: [email protected] http://www.deltaww.com/dcdc P8 LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFIL Figure 20 recommended temperature profile for lead-free wave soldering MECHANICAL DRAWING(BASEPLATE) DS_HA1SV15007_01282015 E-mail: [email protected] http://www.deltaww.com/dcdc P9 MECHANICAL DRAWING(WITHOUT MOUNTING HOLE) DIMENSIONAL TOLERANCE X ±0.3mm x.x ±0.2mm x.xx ±0.1mm DS_HA1SV15007_01282015 E-mail: [email protected] http://www.deltaww.com/dcdc P10 PART NUMBERING SYSTEM H A1 Form Input Factor Voltage V- 110- half Brick 53V~154V S V Number of Product Outputs S– Single Series 15 007 N N F Output Output ON/OFF Pin Voltage Current Logic Length A Option Code V- 15- 007- N– N - 0.145” F- A – Baseplate Series Number 15V 6.7A Negative R - 0.170” RoHS 6/6 H-without mounting hole P– M - SMD pin (Lead Free) Positive Space - RoHS5/6 MODEL LIST MODEL NAME INPUT OUTPUT EFF @ 100% LOAD HA1SV15007PRFA 53V~154V 2.2A 15V 6.7A 88.5% HA1SV15007PRFH 53V~154V 2.2A 15V 6.7A 88.5% Default remote on/off logic is negative and pin length is 0.170” For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office. For modules with through-hole pins and the optional heatspreader, they are intended for wave soldering assembly onto system boards; please do not subject such modules through reflow temperature profile. CONTACT: www.deltaww.com/dcdc Email: [email protected] USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964 Europe: Phone: +31-20-655-0967 Fax: +31-20-655-0999 Asia & the rest of world: Telephone: +886 3 4526107 ext 6220~6224 Fax: +886 3 4513485 WARRANTY Delta offers a five (5) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications. DS_HA1SV15007_01282015 E-mail: [email protected] http://www.deltaww.com/dcdc P11