Wireline® 3dB Quadrature Hybrids
• Drop-in (consult for cut & trimmed and connectorized)
• Bendable / formable
• Low loss, low cost
• Aerospace and commercial heritage
• RoHS compliant (tin-plated and bare finishes only)
Electrical Specification
Bandwidth Optimization
Coupling, Coupled Path (dB)
Unbalanced, Max. (dB), Coupled Path to Main Line
Insertion Loss Max. (dB)
Isolation, Min. (dB)
VSWR, Max.
Power, Average (W)
Power, Peak (kW)
Phase Quadrature Error, Max. (°)
Dielectric Breakdown, Min. (V RMS)
BHC*1
HC*1
BJC*1
JC*1
BHC*2
HC*2
BJC*2
JC*2
Narrow
3.00 ± 0.25
0.5
0.3
20
1.2:1
100
2
±1
500
Narrow
3.00 ± 0.25
0.5
0.3
20
1.2:1
200
2
±1
500
Octave
2.65 ± 0.25
1.3
0.3
20
1.2:1
100
2
±1
500
Octave
3.65 ± 0.25
1.3
0.3
20
1.2:1
200
2
±1
500
* Shield finish code - see Part Number Key on Website Datasheet
Electrical specifications summarized in the table above are determined by measurements at 300 MHz in a matched 50 ohm system and are independent of physical length
and frequency with the exception of power. At jacket temperatures above 55°C, the power should be derated linearly to 50% at 105°C and to 0 at 155°C.
Mechanical Specification
Weight ounces (grams) per inch/mm
Bendable / Formable
Center Line Bend radius, Min.
Dimension “A” Inner Jacket Diameter
Dimension “B” Outer Shield Diameter
Dimension “D” Wire Diameter
0.19 (.55)
Yes
.15 (3,8)
.086 (2,2)
.105 (2,7)
.0124 (0,3)
0.40 (1.14)
Yes
.30 (7,6)
.125 (3,2)
.145 (3,7)
.0201 (0,5)
0.19 (.55)
Yes
.15 (3,8)
.086 (2,2)
.105 (2,7)
.0124 (0,3)
0.40 (1.14)
Yes
.30 (7,6)
.125 (3,2)
.145 (3,7)
.0201 (0,5)
All dimensions shown in decimal inches (mm). Specifications subject to change without notice. For mounting instructions, additional specifications or other products, visit us online or contact the factory.