Data Sheet

VDE - QUICK-CONNECT TERMINALS, INTERNATIONAL POWER TRANSFORMER
1.
Electrical Specifications
A. Maximum Power: 130VA
B. Input Voltage and Frequency: 115/230V, 115V, 230V
@ 50/60Hz
C. Voltage Regulation: __% TYP @ Full Load to No Load
D.
E.
F.
2.
3.
Temperature Rise: __CTYP
Insulation Resistance: > __ MEG ohm
Hi-Pot: 4000 Vrms 1 minute @ Pri to Sec
____ Vrms 1 minute @ Pri to Core
____ Vrms 1 minute @ Sec to Core
Marking: Wabash Transformer, part number (see table), date
code, terminal numbers
Safety:
UL/cUL 5085-2 Recognized (File E182486)
VDE Licensed (File 40001595)
Insulation File No. E182094
Part No.
Single Primary
Dual Primary
115/230V
115V
230V
Series Connection
VDE1-130T-10
VDE2-130T-10
10VCT @ 13.0A
5V @ 26.0A
VDE-130T-126
VDE1-130T-126
VDE2-130T-126
12.6VCT @ 10.31A
6.3V @ 20.62A
VDE-130T-16
VDE1-130T-16
VDE2-130T-16
16VCT @ 8.125A
8V @ 16.25A
VDE-130T-18
VDE1-130T-18
VDE2-130T-18
18VCT @ 7.22A
9V @ 14.44A
VDE-130T-20
VDE1-130T-20
VDE2-130T-20
20VCT @ 6.50A
10V @ 13.00A
VDE-130T-24
VDE1-130T-24
VDE2-130T-24
24VCT @ 5.41A
12V @ 10.83A
VDE-130T-28
VDE1-130T-28
VDE2-130T-28
28VCT @ 4.64A
14V @ 9.28A
VDE-130T-36
VDE1-130T-36
VDE2-130T-36
36VCT @ 3.61A
18V @ 7.22A
VDE-130T-230
VDE1-130T-230
VDE2-130T-230
230VCT @ 0.565A
115V @ 1.13 A
INTERNATIONAL POWER TRANSFORMER
CONTENTS OF THIS DRAWING ARE SUBJECT TO
CHANGE WITHOUT PRIOR NOTICE
● Indicates Like Polarity
Parallel Connection
VDE-130T-10
Wabash Transformer
VDE-130T-XXX
VDE1-130T-XXX
VDE2-130T-XXX
Dim: Inches
Sheet 1 of 1
101 Industrial Park Drive, Clarence, IA 52216
PROPRIETARY NOTICE: THIS DRAWING PRINT OR DOCUMENT AND SUBJECT MATTER DISCLOSED HEREIN ARE PROPRIETARY ITEMS TO WHICH
WABASH TRANSFORMER RETAINS THE EXCLUSIVE RIGHT OF DISSEMINATION, MANUFACTURE AND SALE. THIS DRAWING, PRINT OR DOCUMENT IS SUBMITTED IN
CONFIDENCE FOR CONSIDERATION BY THE RECIPIENT ALONE UNLESS PERMISSION FOR FURTHER DISCLOSURE IS EXPRESSLY GRANTED IN WRITING