AOZ8851-03 Ultra Low Capacitance One-line Bidirectional TVS Diode General Description Features The AOZ8851-03 is an ultra low capacitance one-line bidirectional transient voltage suppressor diode designed to protect high speed data lines and voltage sensitive electronics from high transient conditions and ESD. ESD protection for high-speed data lines: This device incorporates one bidirectional TVS diode in an ultra-small 0201 footprint package. It may be used to meet the ESD immunity requirements of IEC 61000-4-2, Level 4 (±15 kV air, ±15 kV contact discharge). Small package saves board space The AOZ8851-03 comes in an RoHS compliant package and is rated over a -40 °C to +85 °C ambient temperature range. Pb-free device The ultra-small 0.62 mm x 0.32 mm x 0.3 mm 0201 footprint package makes the AOZ8851-03 ideal for applications where PCB space is a premium. The small size and high ESD protection makes it ideal for protecting voltage sensitive electronics from high transient conditions and ESD. Portable handheld devices – Exceeds: IEC 61000-4-2 (ESD) ±20 kV (air), ±20 kV (contact) – Human Body Model (HBM) ±25 kV Ultra low capacitance: 0.22 pF Low clamping voltage Low operating voltage: 3.3 V Applications Keypads, data lines, buttons Notebook computers Digital Cameras Portable GPS MP3 players Typical Application Pin Configuration Signal Line 1 2 Bidirection Protection of Single Line Rev. 2.1 July 2015 www.aosmd.com Page 1 of 7 AOZ8851-03 Ordering Information Part Number Ambient Temperature Range Package Environmental AOZ8851DI-03 -40 °C to +85 °C DFN 0.62 x 0.32 Green Product RoHS Compliant AOS Green Products use reduced levels of Halogens, and are also RoHS compliant. Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information. Absolute Maximum Ratings Exceeding the Absolute Maximum Ratings may damage the device. Parameter Rating VP – VN 3.6 V Peak Pulse Current (IPP), tP = 8/20µs 4A Storage Temperature (TS) -65 °C to +150 °C ESD Rating per IEC61000-4-2, Contact(1) ±20 kV ESD Rating per IEC61000-4-2, Air(1) ±20 kV Model(2) ±15 kV ESD Rating per Human Body Notes: 1. IEC 61000-4-2 discharge with CDischarge = 150 pF, RDischarge = 330 Ω. 2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100 pF, RDischarge = 1.5 kΩ. Maximum Operating Conditions The device is not guaranteed to operate beyond the Maximum Operating Conditions. Parameter Rating Junction Temperature (TJ) Rev. 2.1 July 2015 -40 °C to +125 °C www.aosmd.com Page 2 of 7 AOZ8851-03 Electrical Characteristics TA = 25°C unless otherwise specified. Symbol IPP Parameter Diagram Maximum Reverse Peak Pulse Current (100ns Transmission Line Pulse (TLP)) (IEC61000-4-5 8/20 µs pulse current) VCL Clamping Voltage @ IPP VRWM Working Peak Reverse Voltage IR Maximum Reverse Leakage Current VBR Breakdown Voltage PPK Peak Power Dissipation (IEC61000-4-5 8/20 µs pulse current) CJ Capacitance @ VR = 0 and f = 1 MHz Device AOZ8851DI-03 Rev. 2.1 July 2015 Device VRWM (V) Max. Marking E 3.6 I IPP VCL VBR VRWM IR IT VBR (V) Min. Max. 4.5 12 VRWM VBR VCL V IPP VCL Max. IR (µA) Max. IPP = 1 A IPP = 2 A IPP = 4 A 0.1 www.aosmd.com 5 9 16 PPK (W) CJ (pF) Typ. 65 0.22 Page 3 of 7 AOZ8851-03 Typical Performance Characteristics Clamping Voltage vs. Peak Pulse Current 25 (f = 1MHz, T = 25ºC) 1.2 1.0 20 Normalized Capacitance Clamping Voltage, VCL (V) Typical Variations of CIN vs. VR (tperiod = 100ns, tr = 1ns) 15 10 5 0.8 0.6 0.4 0.2 0 0 2 4 Rev. 2.1 July 2015 6 8 10 12 Peak Pulse Current, IPP (A) 14 16 www.aosmd.com 0 0.5 1.0 1.5 2.0 Input Voltage (V) 2.5 3.0 3.5 Page 4 of 7 AOZ8851-03 Package Dimensions, DFN 0.62x0.32, 2L EP2 S D D1 D2 D1 E1 E TOP VIEW D3 BOTTTOM VIEW A SIDE VIEW Dimensions in millimeters RECOMMENDED LAND PATTERN 0.195 0.210 0.320 Symbols A Min. 0.27 D D1 0.57 0.11 0.145 0.305 0.27 0.17 D2 D3 E E1 Nom. Max. 0.30 0.62 0.16 0.195 0.355 0.32 0.22 0.33 0.67 0.21 0.245 0.405 0.37 0.27 Dimensions in inches Symbols Min. Nom. Max. A 0.0106 0.0118 0.0130 D 0.0224 0.0244 0.0264 D1 0.0043 0.0063 0.0083 0.0057 0.0077 0.0097 D2 0.0120 0.0140 0.0167 D3 0.0106 0.0126 0.0146 E 0.0067 0.0087 0.0107 E1 0.405 0.615 Unit: mm Notes: 1. All dimensions are in millimeters. 2. Dimensions are inclusive of plating. 3. Package body sizes exclude mold flash and gate burrs. Mold flash at the non-lead sides should be less than 6mil each. 4. Controlling dimension is millimeter. Converted inch dimensions are not necessarily exact. 5. Paddle exposed on bottom. Rev. 2.1 July 2015 www.aosmd.com Page 5 of 7 AOZ8851-03 Tape and Reel Dimensions, DFN 0.62x0.32 P1 Carrier Tape D1 P2 T E1 E2 E B0 D0 K0 P0 A0 Feeding Direction UNIT: MM Package A0 B0 K0 D0 D1 E E1 E2 P0 P1 P2 T DFN 0.62x0.32 0.45 0.74 0.34 0.20 1.50 8.00 1.75 3.50 2.00 4.00 2.00 0.20 +0.02/-0.03 ±0.03 +0.03/-0.01 ±0.05 +0.1/-0.0 ±0.10 ±0.10 ±0.05 ±0.05 ±0.05 ±0.05 ±0.05 (8mm) W1 Reel S G K N M V H R W UNIT: MM Tape Size Reel Size M N W W1 H K S G R V 8 mm ø178 ø178.0 ø55.0 MAX. 2.0 N/A N/A N/A ±1.0 MAX. 14.4 ø13.0 ±0.5 8.4 +1.5/-0 ±0.5 10.1 ±0.5 Leader/Trailer and Orientation Trailer Tape 300mm min. Components Tape Orientation in Pocket Leader Tape 500mm min. Detail: Unit Direction in Pocket Rev. 2.1 July 2015 www.aosmd.com Page 6 of 7 AOZ8851-03 Part Marking AOZ8851DI-03 (DFN0.62x0.32) Date Code Pin 2 (1st to 15th) Date Code Pin 2 (16th to end of month) Y E E M Pin 1 Product Number Code Y M Pin 1 Product Number Code LEGAL DISCLAIMER Alpha and Omega Semiconductor makes no representations or warranties with respect to the accuracy or completeness of the information provided herein and takes no liabilities for the consequences of use of such information or any product described herein. Alpha and Omega Semiconductor reserves the right to make changes to such information at any time without further notice. This document does not constitute the grant of any intellectual property rights or representation of non-infringement of any third party’s intellectual property rights. LIFE SUPPORT POLICY ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury of the user. Rev. 2.1 July 2015 2. A critical component in any component of a life support, device, or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. www.aosmd.com Page 7 of 7