Single Thru Hole IDC Contact 12-18 AWG: WTB INTERCONNECT 9177-600 AVX developed the initial SMT discrete wire IDC connector 5 years ago for 26-28AWG AVX wires. Since then, we have seen this Wire-to-Board (WTB) contact technology spread to multiple wire gauges and multiple configurations; standard connectors, capped connectors and single contacts. All of which addresses specific application or cost parameters set forth by our customer in demanding industrial, transportation or commercial applications. The heart of the IDC connector is the true “gas tight” WTB termination that is achieved once the wire is inserted between the dual phosphor bronze contact tines. These opposing tines provide enough spring characteristics to allow the termination to remain stable over extreme levels of temperature, shock and vibration. The new 9177-600 family of contacts incorporates all of the above mentioned capabilities. From low cost single contacts to fully integrated capped contacts. The unique feature of the 600 series is the fact that it was developed for Plated Through Hole (PTH) termination to the PCB. This addresses the rugged power type boards that have to handle larger wire gauges up to 12AWG and 15 Amps per contact of current. The PTH option provides robust PCB attachment and high current capabilities to replace older technology connectors or in most cases soldering stripped wires directly to the PCB. APPLICATIONS • • • • FEATURES AND BENEFITS Industrial pumps, motors and driver boards Solar and alternative energy products Commercial electrical equipment Reference Product Specification & application notes 201-01-141/142 • IDC contact provides a “gas tight” wire termination to the PCB to meet harsh industrial environments • Simple, robust design offers a high performance solution to hand soldering large gauge wires to a PCB • A single contact an handle up to 15A for high current applications with wire replacement up to 3 times • The versatile family of IDC contact can accept 12-18AWG of stranded wires and can be tested for compliance with solid wires ELECTRICAL ENVIRONMENTAL MECHANICAL • Current Rating: 15A • Voltage Rating: 600 VAC • Operating Temperature: -40ºC to +125ºC • • • • Insulator Material: Nylon 46, UL94VO Contact Material: Phosphor Bronze Plating: Tin over Nickel Durability: Wires can be replaced up to 3 time HOW TO ORDER – CONTACT OPTIONS 70 9177 001 Prefix 70 = Contact Series Number of Ways No of Code Ways Details 001 1 Page 2 Code 691 601 612 622 6XX 006 Wire Gauge Size Plating Option 006 = Pure Tin all over Accepted Wire Gauge 12 AWG Solid or Stranded 14 AWG Solid or Stranded 16 AWG Solid or Stranded 18 AWG Solid or Stranded HOW TO ORDER – CAP OPTIONS 60 9177 001 Prefix 60 = Cap Series Number of Ways X 6XX Code No of Ways Details 001 1 Pages 4-5 Wire Insulation Diameter Code Wire Insulation (AWG) Diameter “A” 627 635 642 Ø 2.10 - 2.75 Ø 2.75 - 3.50 Ø 3.50 - 4.25 2.75 3.50 4.25 XX Color Options Assembly Options Code Color Application 0 Black Special Order 1 White Standard Code Description 00 Through Wire 99 With Stop 1 Single Thru Hole IDC Contact 12-18 AWG: WTB INTERCONNECT 9177-600 70-9177-001-6XX-006 CONTACT DETAILS PCB LAYOUT FOR CONTACT Code 691 601 612 622 Accepted Wire Gauge 12 AWG Solid or Stranded 14 AWG Solid or Stranded 16 AWG Solid or Stranded 18 AWG Solid or Stranded A 1.50 1.10 0.82 0.72 NOTES: 1. IDC CONTACT OT ACCEPT WIRES FROM 12 AWG TO 18 AWG. 2. MATERIAL: PHOSPHOR BRONZE. 3. PLATING PURE TIN OVER NICKEL. 4. ALL DIMENSIONS ±0.20 UNLESS SPECIFIED. 5. PACKING IN BAGS, 800 PIECES PER BAG. 6. PRODUCT SPECIFICATION REFER TO 201-01-141. 7. OUTLINE OF CONTACT SEE PAGE 5 FOR ADDITIONAL CLEARANCE REQUIRED FOR WIRE INSERTION TOOL. 8. FOR ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-142. 2 Single Thru Hole IDC Contact 12-18 AWG: WTB INTERCONNECT 9177-600 ASSEMBLY TOOLING Part Number 06-9177-7021-01-000 06-9177-7021-01-000 06-9177-7021-01-000 Wire Insulation Ø 3.50- - 4.25 Ø 3.50- - 4.25 Ø 3.50- - 4.25 A 4.25 4.25 4.25 NOTES: 1. WIRE INSERTION TOOL 06-9177-7021-0X-000, FULL PART NUMBER REFER TO TABLE. 2. TOOL PART NUMBER DEPENDENT ON WIRE INSULATION DIAMETER NOT WIRE GAUGE OR CONTACT NUMBER. 3. ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-142 4. MATERIAL: TOOL STEEL. 5. APACE REQUIRED ON PCB FOR TOO. NO COMPONENTS IN THIS AREA. PCB CLEARANCE AREA FOR TOOL 3 Single Thru Hole IDC Contact 12-18 AWG: WTB INTERCONNECT 9177-600 60-9177-001-6XX-X00 1 WAY WIRE THROUGH CAP DETAILS Code Diameter A 627 2.75 635 3.50 642 4.25 page 56 NOTES: 1. CAP FOR IDC WIRE TO BOARD CONNECTION, 1 WAY WITH THROUGH WIRE. 2. WIRE THROUGH CAP FOR ASSEMBLY AT ANY POSITION ON A WIRE. 3. CAP MATERIAL: GLASS FILLED NYLON 46, UL94 V-0. COLOR SEE PAGE 56. 4. CAP DESIGNED TO ACCOMMODATE WIRE INSULTATION. DIAMETERS 2.10MM TO 2.75MM, 2.75MM TO 3.50MM AND 3.50MM TO 4.25MM. 5. ALL DIMENSIONS ±0.20 UNLESS STATED. 6. PACKED IN BAGS, QUANTITY 800 PIECES PER BAG. 7. PRODUCT SPECIFICATION REFER TO 201-01-141. 8. FOR ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-142. 4 Text Note 4 1.50 1.10 0.82 Single Thru Hole IDC Contact 12-18 AWG: WTB INTERCONNECT 9177-600 60-9177-001-6XX-X99 1 WAY WIRE STOP CAP DETAILS Code Diameter A 627 2.75 635 3.50 642 4.25 page 50 Text Note 5 2.75 3.50 4.25 NOTES: 1. CAP FOR IDC WIRE TO BOARD CONNECTION, 1 WAY WITH WIRE STOP. 2. WIRE STOP FOR USE AT END OF WIRE. 3. SLOT TO CHECK WIRE POSITION BEFORE ASSEMBLY. 4. CAP MATERIAL: GLASS FILLED NYLON 46, UL94 V-0. COLOR SEE PAGE 56. 5. CAP DESIGNED TO ACCOMMODATE WIRE INSULTATION. DIAMETERS 2.10MM TO 2.75MM, 2.75MM TO 3.50MM AND 3.50MM TO 4.25MM. 6. ALL DIMENSIONS ±0.20 UNLESS STATED. 7. PACKED IN BAGS, QUANTITY 800 PIECES PER BAG. 8. PRODUCT SPECIFICATION REFER TO 201-01-141. 9. FOR ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-142. 5