Single Thru Hole IDC Contact 12-18 AWG: 9177-600 Datasheet

Single Thru Hole IDC Contact
12-18 AWG: WTB
INTERCONNECT
9177-600
AVX developed the initial SMT discrete wire IDC connector 5 years ago for 26-28AWG
AVX wires. Since then, we have seen this Wire-to-Board (WTB) contact technology
spread to multiple wire gauges and multiple configurations; standard connectors,
capped connectors and single contacts. All of which addresses specific application or
cost parameters set forth by our customer in demanding industrial, transportation or
commercial applications. The heart of the IDC connector is the true “gas tight” WTB
termination that is achieved once the wire is inserted between the dual phosphor bronze
contact tines. These opposing tines provide enough spring characteristics to allow the
termination to remain stable over extreme levels of temperature, shock and vibration.
The new 9177-600 family of contacts incorporates all of the above mentioned
capabilities. From low cost single contacts to fully integrated capped contacts. The
unique feature of the 600 series is the fact that it was developed for Plated Through Hole
(PTH) termination to the PCB. This addresses the rugged power type boards that have
to handle larger wire gauges up to 12AWG and 15 Amps per contact of current. The PTH
option provides robust PCB attachment and high current capabilities to replace older
technology connectors or in most cases soldering stripped wires directly to the PCB.
APPLICATIONS
•
•
•
•
FEATURES AND BENEFITS
Industrial pumps, motors and driver boards
Solar and alternative energy products
Commercial electrical equipment
Reference Product Specification & application
notes 201-01-141/142
• IDC contact provides a “gas tight” wire termination to the PCB to meet
harsh industrial environments
• Simple, robust design offers a high performance solution to hand
soldering large gauge wires to a PCB
• A single contact an handle up to 15A for high current applications with
wire replacement up to 3 times
• The versatile family of IDC contact can accept 12-18AWG of stranded
wires and can be tested for compliance with solid wires
ELECTRICAL
ENVIRONMENTAL
MECHANICAL
• Current Rating: 15A
• Voltage Rating: 600 VAC
• Operating Temperature:
-40ºC to +125ºC
•
•
•
•
Insulator Material: Nylon 46, UL94VO
Contact Material: Phosphor Bronze
Plating: Tin over Nickel
Durability: Wires can be replaced up to 3 time
HOW TO ORDER – CONTACT OPTIONS
70
9177
001
Prefix
70 = Contact
Series
Number of Ways
No of
Code
Ways Details
001
1
Page 2
Code
691
601
612
622
6XX
006
Wire Gauge Size
Plating
Option
006 = Pure Tin
all over
Accepted
Wire Gauge
12 AWG Solid or Stranded
14 AWG Solid or Stranded
16 AWG Solid or Stranded
18 AWG Solid or Stranded
HOW TO ORDER – CAP OPTIONS
60
9177
001
Prefix
60 = Cap
Series
Number of Ways
X
6XX
Code
No of
Ways
Details
001
1
Pages
4-5
Wire Insulation Diameter
Code
Wire Insulation
(AWG)
Diameter
“A”
627
635
642
Ø 2.10 - 2.75
Ø 2.75 - 3.50
Ø 3.50 - 4.25
2.75
3.50
4.25
XX
Color Options
Assembly Options
Code Color Application
0
Black Special Order
1
White
Standard
Code Description
00
Through Wire
99
With Stop
1
Single Thru Hole IDC Contact
12-18 AWG: WTB
INTERCONNECT
9177-600
70-9177-001-6XX-006
CONTACT DETAILS
PCB LAYOUT FOR CONTACT
Code
691
601
612
622
Accepted
Wire Gauge
12 AWG Solid or Stranded
14 AWG Solid or Stranded
16 AWG Solid or Stranded
18 AWG Solid or Stranded
A
1.50
1.10
0.82
0.72
NOTES:
1. IDC CONTACT OT ACCEPT WIRES FROM 12 AWG TO 18 AWG.
2. MATERIAL: PHOSPHOR BRONZE.
3. PLATING PURE TIN OVER NICKEL.
4. ALL DIMENSIONS ±0.20 UNLESS SPECIFIED.
5. PACKING IN BAGS, 800 PIECES PER BAG.
6. PRODUCT SPECIFICATION REFER TO 201-01-141.
7. OUTLINE OF CONTACT SEE PAGE 5 FOR ADDITIONAL CLEARANCE REQUIRED FOR
WIRE INSERTION TOOL.
8. FOR ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-142.
2
Single Thru Hole IDC Contact
12-18 AWG: WTB
INTERCONNECT
9177-600
ASSEMBLY TOOLING
Part Number
06-9177-7021-01-000
06-9177-7021-01-000
06-9177-7021-01-000
Wire Insulation
Ø 3.50- - 4.25
Ø 3.50- - 4.25
Ø 3.50- - 4.25
A
4.25
4.25
4.25
NOTES:
1. WIRE INSERTION TOOL 06-9177-7021-0X-000, FULL PART NUMBER REFER TO TABLE.
2. TOOL PART NUMBER DEPENDENT ON WIRE INSULATION DIAMETER NOT WIRE
GAUGE OR CONTACT NUMBER.
3. ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-142
4. MATERIAL: TOOL STEEL.
5. APACE REQUIRED ON PCB FOR TOO. NO COMPONENTS IN THIS AREA.
PCB CLEARANCE AREA FOR TOOL
3
Single Thru Hole IDC Contact
12-18 AWG: WTB
INTERCONNECT
9177-600
60-9177-001-6XX-X00 1 WAY WIRE THROUGH
CAP DETAILS
Code Diameter
A
627
2.75
635
3.50
642
4.25
page 56
NOTES:
1. CAP FOR IDC WIRE TO BOARD CONNECTION, 1 WAY WITH THROUGH WIRE.
2. WIRE THROUGH CAP FOR ASSEMBLY AT ANY POSITION ON A WIRE.
3. CAP MATERIAL: GLASS FILLED NYLON 46, UL94 V-0. COLOR SEE PAGE 56.
4. CAP DESIGNED TO ACCOMMODATE WIRE INSULTATION.
DIAMETERS 2.10MM TO 2.75MM, 2.75MM TO 3.50MM AND 3.50MM TO 4.25MM.
5. ALL DIMENSIONS ±0.20 UNLESS STATED.
6. PACKED IN BAGS, QUANTITY 800 PIECES PER BAG.
7. PRODUCT SPECIFICATION REFER TO 201-01-141.
8. FOR ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-142.
4
Text
Note 4
1.50
1.10
0.82
Single Thru Hole IDC Contact
12-18 AWG: WTB
INTERCONNECT
9177-600
60-9177-001-6XX-X99 1 WAY WIRE STOP
CAP DETAILS
Code Diameter
A
627
2.75
635
3.50
642
4.25
page 50
Text
Note 5
2.75
3.50
4.25
NOTES:
1. CAP FOR IDC WIRE TO BOARD CONNECTION, 1 WAY WITH WIRE STOP.
2. WIRE STOP FOR USE AT END OF WIRE.
3. SLOT TO CHECK WIRE POSITION BEFORE ASSEMBLY.
4. CAP MATERIAL: GLASS FILLED NYLON 46, UL94 V-0. COLOR SEE PAGE 56.
5. CAP DESIGNED TO ACCOMMODATE WIRE INSULTATION.
DIAMETERS 2.10MM TO 2.75MM, 2.75MM TO 3.50MM AND 3.50MM TO 4.25MM.
6. ALL DIMENSIONS ±0.20 UNLESS STATED.
7. PACKED IN BAGS, QUANTITY 800 PIECES PER BAG.
8. PRODUCT SPECIFICATION REFER TO 201-01-141.
9. FOR ASSEMBLY DETAILS REFER TO APPLICATION NOTES 201-01-142.
5