ROHM BP5063-5_10

Data Sheet
100VAC Input/5VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5063-5
Absolute Maximum Ratings
Unit
Vi
Iomax
Vsurge
Topr
Tstg
Tcmax
170
200
2
−25 to +80
−25 to +105
105
V
mApk
kV
°C
°C
°C
Electrical Characteristics
220V −
C1
22µF/200V
7
5
3
1
FUSE
1A
C2
0.1µF
L1
820µH
+
Function
Output terminal Vo(5V)
N.C.
Choke coil connect
Not used
Choke coil connect
Not used
COMMON
Not used
Not used
Input terminal Vi(141VDC)
C3
− 330µF/25V
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
External Component Specifications
Use a quick-acting fuse 1A
C1: Input smoothing
capacitor
Capacitance : 22 to 100µF Rated voltage : 200V or higher
Ripple current is 0.13Arms above.
C2: Noise reduction
capacitor
Capacitance : 0.1 to 0.22µF Rated voltage : 200V or higher
Use a film or ceramic capacitor to reduce voltage noise.
Evaluate under actual conditions before use.
C3: Output smoothing
capacitor
Capacitance : 100 to 470µF Rated voltage : 16V or higher,
ESR is 0.25Ω max. Ripple current is 0.25Arms or above.
Evaluate performance in actual set.
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current 20A or higher.
(Full-wave rectification can be used.)
Coil for switching regulator. The inductance should be 820µH,
the rated direct current should be 0.42A or above in order to
prevent abnormal heating or oscillation.
10 to 22Ω 1/4W
Optional for voltage noise reduction. Determine the ideal value through
actual evaluation.
A varistor must be used to protect the part from lightning surges and
static electricity.
L1: Choke coil
R1: Noise reduction
resistor
ZNR: Varistor
1
0.25±0.05
4.85MAX.
4.25MAX.
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
Derating Curve
Output Current Io(mA)
200
160
120
Operation Range
80
40
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Switching Frequency
40
35
30
25
20
15
10
5
0
0
Switching Frequency
50
100
150
Output Current(mA)
200
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency
(Ta=25°C, Vi=141V)
50
100
150
Output Current Io(mA)
200
Load Regulation
FUSE: Fuse
D1: Rectifier diode
2
2.54
240
Switching Frequency tsw(kHz)
Please note that pin No.10
side is input.
ZNR +
3
2.54�9=22.86
Conversion Efficiency (%)
Conditions
DC(80 to 120VAC)
Vi=141V, Io=100mA
Vi=141V
∗1
Vi=113 to 170V, Io=100mA
Vi=141V, Io=0 to 100mA
Vi=141V, Io=100mA
∗2
Vi=141V, Io=200mA
Unit
V
V
mA
V
V
Vp-p
%
Pin No.
1
2
3
4
5
6
7
8
9
10
BP5063-5
Input
AC100V
50Hz/60Hz
5
0.5
3.3MAX.
1/1
5.3
Output Voltage Vo(V)
141
5.0
−
0.05
0.07
0.05
62
Max.
170
5.3
200
0.15
0.20
0.15
−
Application Circuit
10
7
1.4
Load Regulation
(Ta=25°C, Vi=141V)
5.2
5.1
5.0
4.9
4.8
4.7
0
50
100
150
Output Current Io(mA)
200
Surface Temperature Increase
Temperature Rising ∆T(°C)
Typ.
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Spike noise is not included in output ripple voltage.
R1
10Ω1/4W
10
Derating Curve
Symbol Min.
Parameter
Input voltage range
113
Vi
Output voltage
4.7
Vo
Output current
0
Io
Line regulation
−
Vr
Load regulation
−
Vl
Output ripple voltage
−
Vp
Power conversion efficiency
50
η
D1
9.1MAX.
28.2MAX.
Mark Side
Limits
17.9MAX.
Symbol
4±1.0
Parameter
Input voltage
Maximum Output current
ESD endurance
Operating temperature range
Storage temperature range
Maximum surface temperature
Dimensions (Unit : mm)
40
35
30
25
20
15
10
5
0
Surface Temperature Increase
(Ta=25°C, Vi=141V)
0 20 40 60 80 100 120 140 160 180 200
Output Current Io(mA)
2010.01 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010A