RoHS Test Report

TEST REPORT
REPORT NO.KA/2005/90345/A-1
DATE: 2005/9/13
PAGE: 1 OF 1
THE FOLLOWING MERCHANDISE WAS(WERE) SUBMITTED AND IDENTIFIED BY THE CLIENT AS :
: MINMAX TECHNOLOGY CO.,LTD.
: 18, SIN-SIN ROAD, TAINAN 702, TAIWAN
PRODUCT DESCRIPTION
: MIX TEST:DC/DC CONVERTER.
STYLE/ITEM NO.
: MAU300 SERIES.
SAMPLE
: AS ATTACHED PHOTO.
TESTING DATE
: 2005/9/6 TO 2005/9/13 .
SAMPLE RECEIVED
: 2005/09/06.
============================================================================================
WE HAVE TESTED THE SAMPLE(S) SUBMITTED AS REQUESTED AND THE FOLLOWING RESULTS WERE
OBTAINED.
CLIENT
TEST ITEM(S)
UNIT
CADMIUM (Cd)
ppm
CHROMIUM VI (Cr+6)
ppm
MERCURY (Hg)
ppm
LEAD (Pb)
ppm
PBBs(Polybrominated biphenyls)
Monobromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Tetrabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
PBDEs(Polybrominated biphenyl
ethers)
Monobromobiphenyl ether
Dibromobiphenyl ether
Tribromobiphenyl ether
Tetrabromobiphenyl ether
Pentabromobiphenyl ether
Hexabromobiphenyl ether
Heptabromobiphenyl ether
Octabromobiphenyl ether
Nonabromobiphenyl ether
Decabromobiphenyl ether
NOTE:n.d. = not detected.
--%
%
%
%
%
%
%
%
%
%
METHOD
ICP-AES after reference to EN 1122, Method
B:2001 or other acid digestion.
ANALYSIS BY US EPA 7196A WITH ADVANCE
TREATMENT US EPA 3060A.
ICP-AES after reference to US EPA 3052 or
other acid digestion.
ICP-AES after reference to US EPA 3050B or
other acid digestion.
---
DET. LMT
RESULT
2
n.d.
2
n.d.
2
n.d.
2
72.1
--0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
--n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
---
---
---
With reference to USEPA3540C or
USEPA3550C. Analysis was performed by
HPLC/DAD, LC/MS or GC/MS. (prohibited by
2002/95/EC (RoHS), 83/264/EEC, and
76/769/EEC)
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
0.0005
n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
n.d.
With reference to USEPA3540C or
USEPA3550C. Analysis was performed by
HPLC/DAD, LC/MS or GC/MS. (prohibited by
2002/95/EC (RoHS), 83/264/EEC, and
76/769/EEC)
--%
%
%
%
%
%
%
%
%
%
<END>
This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf. Attention is drawn to the limitations of liability, indemnification,
and Jurisdictional issues defined therein. The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This Test Report cannot be
reproduced, except in full, without prior written permission of the Company. 此報告是遵循本公司訂定之通用服務條款所製作發放。請注意此條款列印於背面,將本公司
之義務,免責,管轄權皆明確規範之。此報告結果除非另有說明僅對檢驗之樣品負責。本報告未經本公司書面許可,不可部份複製。
SGS Taiwan Ltd.
台灣檢驗科技股份有限公司
No. 208, Chung Hwa 2nd Road, San Ming District, Kaohsiung, Taiwan /
t (886-7) 323-0920
f (886-7) 315-7484
高 雄 市 三 民 區 中 華 二 路 208 號
www.sgs.com.tw
Member of the SGS Group