PRODUCT DATASHEET EN100/EN150 Environmental Meters with 11 Functions Environmental meters measuring multiple indoor and outdoor conditions. Air Velocity/Air Flow Humidity/Temperature Light Level (EN100) UV Level (EN150) EN150 EN100 Common Features • Built-in sensors measure 11 environmental conditions including Air Velocity, Air Flow, Temperature, Humidity, • Built-in Light sensor measures light level Wet Bulb, Dew Point, Heat Index, Wind Chill, • Auto-rotating display depending on function Barometric Pressure, and Altitude • Model EN100 Additional Functionality Field replaceable low friction vane wheel improves air velocity accuracy • Backlit LCD display (auto off after 5 seconds) • Data Hold ‘freezes’ displayed reading • Auto power off (with disable feature) • Complete with built-in multiparameter sensors, Model EN150 Additional Functionality • Built-in UV sensor measures UV light level – Natural Sunlight Measurements wrist strap, and CR2032 battery. (Optional Pt -1000Ω probe, EN100-TP, for external temperature measurement) EN100-TP Ordering EN100................ Environmental Meter (11 functions including Light Level measurement) EN150................ Environmental Meter (11 functions including UV Light measurement) EN100-TP.......... RTD Temperature Probe (PT-1000Ω) EN100-V............ Replacement Vane for EN100 and EN150 (2pk) Specifications subject to change without notice. Copyright © 2013-2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. Rev. 7/7/15 www.extech.com Range Max Resolution Basic Accuracy 0 to 1860Fc 0.1Fc ±5% 0 to 20,000Lux 1Lux ±5% µW/cm2 0 to 1999µW/cm2 1µW/cm2 ±4%FS mW/cm 2 to 20mW/cm 0.01mW/cm2 ±4%FS Specifications Light Level (EN100 only) Foot Candles Lux UVA Light - 290nm to 390nm (EN150 only) 2 2 Air Velocity ft/min (feet per minute) 80 to 3940 ft/min 1 ft/min ±3%FS m/s (meters per second) 0.4 to 20m/s 0.1m/s ±3%FS km/h (kilometers per hour) 1.4 to 72km/h 0.1km/h ±3%FS MPH (miles per hour) 0.9 to 45MPH 0.1MPH ±3%FS knots (nautical miles per hour) 0.8 to 38.8 knots 0.1knots ±3%FS 0.847 to 1,271,300CFM 0.001CFM 0.024 to 36,000CMM 0.001CMM Air Volume CFM CMM Temperature (with optional RTD probe) 14 to 158°F (-10 to 70°C) 0.1°F/°C ±2.5°F/±1.2°C Temperature (ambient) 32 to 122°F (0 to 50°C) 0.1°F/°C ±2.5°F/±1.2°C % Relative Humidity 10 to 95%RH 0.1%RH ±4%RH of reading Wet Bulb 22.3 to 120.2°F (-5.4 to 49.0°C) 0.1°F/°C calculated Dew Point -13.5 to 120.2°F (-25.3 to 49.0°C) 0.1°F/°C calculated Wind Chill 15.1 to 111.6°F (-9.4 to 44.2°C) 0.1°F/°C ±3.6°F/±2°C Heat Index 32 to 212°F (0 to 100°C) 0.1°F/°C ±3.6°F/±2°C inHg 0.29 to 32.48inHg 0.01inHg ±0.05inHg mmHg 7.5 to 825mmHg 0.1mmHg ±1.2mmHg hPa 10 to 1100hPa 0.1hPa ±2hPa Barometric Pressure Altitude feet (ft) -6000 to 30000ft 1ft ±50ft meter (m) -2000 to 9000m 1m ±15m Dimensions 4.7 x 1.7 x 0.7" (120 x 45 x 20mm); Vane: 1.2" (31mm) Weight 5.6oz (160g) Specifications subject to change without notice. Copyright © 2013-2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form. www.extech.com