English Datasheet

PRODUCT DATASHEET
EN100/EN150 Environmental
Meters with 11 Functions
Environmental meters measuring multiple indoor and outdoor conditions.
Air Velocity/Air Flow
Humidity/Temperature
Light Level (EN100)
UV Level (EN150)
EN150
EN100
Common Features
•
Built-in sensors measure 11 environmental conditions
including Air Velocity, Air Flow, Temperature, Humidity,
•
Built-in Light sensor measures light level
Wet Bulb, Dew Point, Heat Index, Wind Chill,
•
Auto-rotating display depending on function
Barometric Pressure, and Altitude
•
Model EN100 Additional Functionality
Field replaceable low friction vane wheel improves
air velocity accuracy
•
Backlit LCD display (auto off after 5 seconds)
•
Data Hold ‘freezes’ displayed reading
•
Auto power off (with disable feature)
•
Complete with built-in multiparameter sensors,
Model EN150 Additional Functionality
•
Built-in UV sensor measures UV light level – Natural
Sunlight Measurements
wrist strap, and CR2032 battery.
(Optional Pt -1000Ω probe, EN100-TP, for external
temperature measurement)
EN100-TP
Ordering
EN100................ Environmental Meter (11 functions including Light Level measurement)
EN150................ Environmental Meter (11 functions including UV Light measurement)
EN100-TP.......... RTD Temperature Probe (PT-1000Ω)
EN100-V............ Replacement Vane for EN100 and EN150 (2pk)
Specifications subject to change without notice. Copyright © 2013-2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form.
Rev. 7/7/15
www.extech.com
Range
Max Resolution
Basic Accuracy
0 to 1860Fc
0.1Fc
±5%
0 to 20,000Lux
1Lux
±5%
µW/cm2
0 to 1999µW/cm2
1µW/cm2
±4%FS
mW/cm
2 to 20mW/cm
0.01mW/cm2
±4%FS
Specifications
Light Level (EN100 only)
Foot Candles
Lux
UVA Light - 290nm to 390nm (EN150 only)
2
2
Air Velocity
ft/min (feet per minute)
80 to 3940 ft/min
1 ft/min
±3%FS
m/s (meters per second)
0.4 to 20m/s
0.1m/s
±3%FS
km/h (kilometers per hour)
1.4 to 72km/h
0.1km/h
±3%FS
MPH (miles per hour)
0.9 to 45MPH
0.1MPH
±3%FS
knots (nautical miles per hour)
0.8 to 38.8 knots
0.1knots
±3%FS
0.847 to 1,271,300CFM
0.001CFM
0.024 to 36,000CMM
0.001CMM
Air Volume
CFM
CMM
Temperature (with optional RTD probe)
14 to 158°F (-10 to 70°C)
0.1°F/°C
±2.5°F/±1.2°C
Temperature (ambient)
32 to 122°F (0 to 50°C)
0.1°F/°C
±2.5°F/±1.2°C
% Relative Humidity
10 to 95%RH
0.1%RH
±4%RH of reading
Wet Bulb
22.3 to 120.2°F (-5.4 to 49.0°C)
0.1°F/°C
calculated
Dew Point
-13.5 to 120.2°F (-25.3 to 49.0°C)
0.1°F/°C
calculated
Wind Chill
15.1 to 111.6°F (-9.4 to 44.2°C)
0.1°F/°C
±3.6°F/±2°C
Heat Index
32 to 212°F (0 to 100°C)
0.1°F/°C
±3.6°F/±2°C
inHg
0.29 to 32.48inHg
0.01inHg
±0.05inHg
mmHg
7.5 to 825mmHg
0.1mmHg
±1.2mmHg
hPa
10 to 1100hPa
0.1hPa
±2hPa
Barometric Pressure
Altitude
feet (ft)
-6000 to 30000ft
1ft
±50ft
meter (m)
-2000 to 9000m
1m
±15m
Dimensions
4.7 x 1.7 x 0.7" (120 x 45 x 20mm); Vane: 1.2" (31mm)
Weight
5.6oz (160g)
Specifications subject to change without notice. Copyright © 2013-2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form.