MiVoice-Business-3300-Controllers-Datasheet_EN.pdf

Mitel MiVoice Business 3300 Controllers
Purpose Built Hardware Designed to Address a Variety of Business Needs
When it comes to your communications solution,
sometimes it needs to provide support for more than just
the latest in VoIP technologies.
This could entail support for analog trunks for emergency
purposes or analog fax machines for the business.
Mitel 3300 Controllers are specifically designed
hardware platforms on which the Mitel MiVoice Business
communications solution can reside on.
digital / analog trunking, and support for analog devices,
such as fax machines - all in a single package.
The other unique aspect of the Mitel 3300 Controller is
that it can be deployed as a media gateway, providing
your business with a “gateway” to productivity
enhancing solutions, like unified messaging and mobile
integration - all without having to remove your existing
communications system.
Mitel 3300 Controllers are available in several variants -
Together they provide your buisness with a complete
communications solution that provides voice
communications, unified messaging, auto-attendant,
CX II / CXi II, MXe II, and AX - with each offering unique
capabilities to address a wide range of business needs.
Mitel 3300 Controllers
3300 CX II/
3300 CXi II
3300 MXe III
Standard
3300 MXe III
Expanded
3300 AX
Maximum number of devices
(including softphones and Contact
Center agents)1
150
350
1,500
400 1,2
Maximum number of IP phones1
150
300
1,400
125 1,2
Maximum number of SIP devices /
users
150
300
1,000
100
Maximum ACD Agents1
50
100
350
50
Maximum 5550 IP Consoles
8
16
24
8
Maximum MiVoice Business Consoles
8
16
24
8
Maximum number of Analog devices10
150
350
576
288
1 Quad DSP Module
Power Supply, 40
Echo Cancellers
Specification
Shipped with
2 x ADI 21363 DSP
1 Quad DSP Module
modules Power Supply,
Power Supply, 64
32 Echo Cancellers
Echo Cancellers AMB
AMB
1 Quad DSP Module
Power Supply, 128
Echo Cancellers AMB
Main Software Storage Media
16 GB SATA Solid State
Drive
32 GB Solid State
Drive or 160GB SATA
Hard Drive
32 GB Solid State
2 GB Flash Drive, 4 GB
Drive or 160 GB SATA Flash Drive for Voice
Hard Drive
Mail
512 MB
512 MB
512 MB
512 MB
3
6
5
2
Installed RAM
Available MMC Slots
MMC Slots for
Mitel | 2
Quad CIM, Single T1/E1, Dual FIM, Quad CIM, Dual FIM, Quad CIM,
Quad BRI, and DSP II Single and Dual T1/E1, Single and Dual T1/E1,
Quad BRI, Quad DSP, Quad BRI, Quad DSP,
DSP II and
DSP II and
Echo Canceller
Echo Canceller
Single and Dual T1/
E1, Quad BRI, Quad
DSP, DSP and Echo
Canceller
Mitel 3300 Controllers (coninued)
3300 CX II/
Specification
3300 CXi II
3300 MXe III
Standard
3300 MXe III
Expanded
3300 AX
Maximum embedded T1/E1 digital
trunk modules
2 (Does not support
Dual trunk modules)
3
4
1
Maximum embedded BRI modules
2 (Does not support
Dual trunk modules)
3
4
1
See CXi Controller Data
connectivity section
2
2
2 (10/100 only)
0 (1)
3 (2)
3 (2)
2 (1)
Maximum Echo Canceller Channels
96
64
192
128
Maximum G.729a compression
channels
(DSP II=128, Quad DSP=32, Dual DSP=16)
64 with DSP II
128
192
128
Maximum T.38 channels
8
32
32
32
Maximum number of NSU’s
0
8
8
2 (R2 NSU only)
Maximum number of digital links
(except BRI)
2
16
16
4
Maximum Embedded BRI interfaces
(2 channels per interface)
8
12
12
4
Maximum number of Dual FIM
modules
0
4
4
1
Dual FIM can be used to connect
0
NSU, DSU, Triple FIM
card and SX200 Bay
NSU, DSU, Triple FIM
card and SX200 Bay
R2 NSU
Analog Main Board4,5
6 LS trunks,
4 ONS ports
6 LS trunks,
4 ONS ports
6 LS trunks,
4 ONS ports
0
Analog Option Board4,5
6 LS trunks,
4 ONS ports
0
0
0
Analog Line card slots6
0
0
0
12
Maximum number of CIM connected
ASU’s
3
12
12
0
Maximum number of Fiber and
Copper connected SX200 Bays
0
7
7
0
Tone generators
128
128
128
128
Tone detector circuits
32
32
32
32
E2T Channels
64
64
1287
128
DTMF Receivers
128
128
192
128
IP Networking – max IP trunks
between MiVoice Business systems
2000
2000
2000
2000
IP Networking – total max IP trunks
2000
2000
2000
2000
SIP Trunking – total maximum SIP
trunks
2000
2000
2000
2000
SIP trunking – max SIP trunks between
peers
2000
2000
2000
2000
Maximum controllers in a cluster8
999
999
999
999
STP and RSTP
Yes
Yes
Yes
Yes
10/100/1000 MB Ethernet ports
Maximum Quad DSP
or (DSP II modules)
Mitel | 3
Voice Mail Specifications
3300 CX II/
3300 CXi II
3300 MXe III
Standard
3300 MXe III
Expanded
3300 AX
Embedded voice mail ports as
standard
16
20
20
20
Maximum embedded Voice mail ports
16
30
30
20
Maximum mailboxes9
750
750
750
750
Specification
Storage hours
Maximum messages per mailbox
30 with SSD 130 with
HDD
100
130 with SDD 130 with 130 with SDD 130 with
HDD
HDD
100
100
25
100
Engineering rules apply.
1
For low traffic solutions, like Hospitality systems, up to a maximum of 576 devices will be supported, 288 analog devices and up to 288 IP devices. For
systems of this size please refer to Mitel system engineering.
2
The Maximum Analog device limit is a nominal figure that depends on the Hardware used to connect the Analog devices. Options include the ASU II and the
SX200 Peripheral Bay Cabinet.
3
Includes Music-on-Hold (1 source supported), Paging (1 paging zone), System Fail Transfer (2 circuits).
4
Analog trunks support CLASS Signaling for North America and Latin America, ETSI Class for international markets. Onboard analog trunks are not supported
in Malaysia.
5
The Analog Line card is available in two variants; the 24 ONS circuit card and the 4 LS trunks and 12 ONS extension card. Note the 4+12 Card supports 4 SFT
circuits.
6
Supports up to 192 ET2 channels when being used in a Trunking Gateway configuration.
7
Up to 999 controllers can be clustered as a single system to support over 65,000 IP ports. Mitel’s MiVoice Business System Data Synchronization technology
is used to enable feature transparency across a cluster of controllers.
8
Up to 748 mailboxes can be used for users or multi-level auto attendant. Two mailboxes are reserved for Administration.
9
Maximum numbers reflect 100% Analog device support with no other phone type being supported on Controller.
10
Mitel | 4
Mitel 3300 CXi II Controller
Data Connectivity
EMBEDDED BRI MODULE (CX II / CXi II / MXE III / AX
CONTROLLERS)
Integral 16-port powered Layer 2 10/100 Ethernet switch
The Embedded BRI module has four Basic Rate Circuits
with embedded 802.af support.
(total 8 – 64kbs channels)
HAS AN ADDITIONAL GIGE CAPABLE LAN PORT
• Provides connection to additional switch ports and router
ALSO HAS A 10/100 WAN PORT THAT IS AN
“INTERNET GATEWAY”
EACH CHANNEL MAY BE CONFIGURED AS
EITHER A:
• T (trunk) interface for links from a BRI Central Office (CO)
• S (subscriber) interface for connecting up to eight BRI
devices.
• WAN port provides NAT and firewall capabilities
Note: S interfaces support only basic call features such as calling number
display for BRI devices (BRI call handling such as Hold or Transfer are not
supported). BRI devices are not line powered from the embedded BRI
module.
• WAN port does not support IP networking
Note: This module does not support U interfaces.
• WAN port provides connection to an ISP for Internet access
(e.g., DSL or cable)
USE EXTERNAL ROUTER FOR IP NETWORKING
• Same as you would with a CX II, MXe III, AX Controller
Mitel Steamline (24-Port Versions)
• Ethernet services over two-wires
SIP Lineside and Trunking Specifications
• Power over Ethernet
Please see the SIP CoE MCD RFC specifications document
• Cat 3 or better cabling
on Mitel OnLine for up to date SIP specification support.
• Up to 1200 ft
• Simple deployment with a station-side dongle, delivering
Ethernet services and power
Digital Trunk Connectivity
DUAL EMBEDDED DIGITAL TRUNK MODULE
(MXE III CONTROLLER AND AX CONTROLLER)
• Each module has two E1/T1 trunk interfaces (links)
• Provides PRI / QSIG / T1-D4 / T1 CAS (T1-D4) / DASS II / DPNSS
/ IDA-P protocol through the controller (No NSU required)
• Each interface can run a different protocol, either PRI, QSIG, or
T1-D4
DOES NOT SUPPORT:
• Min / Max, NFAS, D-Channel Backup or TDM XNET (Hybrid
XNET is supported).
Mitel | 5
Dimensions
Specification
Height
3300 CONTROLLER
CX II / CXi II – 3.5 in. (8.9 cm.) (2U)
MXe III – 3.5 in. (8.9 cm.) (2U)
AX – 13.35 in. (39.90 cm.) (7 U)
Width
CX II / CXi II - - 17.75 in. (45.1 cm.)
(19 in. rack mountable)
ANALOG
SERVICES UNIT
(ASU)
NETWORK
SERVICES UNIT
(NSU)
STREAMLINE
ASU – 1.75 in.
(4.454 cm.) (1 U)
1.75 in. (4.454 cm.)
(1 U)
1.75 in. (4.454 cm.)
(1 U)
ASU II – 3.3 in. (8.4
cm.) (2 U)
17.75 in. (45.1 cm.)
17.75 in. (45.1 cm.)
17.13 in. (43.5 cm.)
(19 in. rack mountable) (19 in. rack mountable) (19 in. rack mountable)
MXe III - 17.75 in. (45.1 cm.) (19 in.
rack mountable)
AX – 17.4 in. (44.20 cm.)
Depth
CX II / CXi II – 16.5 in. (41.9 cm.)
15.5 in. (39.4 cm.)
9.92 in. (25.2 cm.)
8.41 lb. (4.27 kg.)
7.96 lb. (3.61 kg.)
3300 CONTROLLER
ANALOG
SERVICES UNIT
(ASU)
NETWORK
SERVICES UNIT
(NSU)
STREAMLINE
40° to 122°F
(4° to 50°C)
40° to 122°F
(4° to 50°C)
40° to 122°F
(4° to 50°C)
(10°C to 50°C)
5% to 95%
relative humidity,
non- condensing
5% to 95%
relative humidity,
non- condensing
5% to 95%
relative humidity,
non- condensing
10% to 95%
relative humidity,
non- condensing
CX II - 170 BTUs per hour
ASU – 170 BTUs per
hour
60 BTUs per hour
24-Port: 61 BTUs per
hour
MXe III – 20.25 in. (51.4 cm.)
Weight
ASU – 15.5 in. (39.4
cm.)
AX – 13.87 in. (35.23 cm.)
ASU II – 13.3 in. (33.8
cm.)
CX II / CXi II – 19.8 lb. (8.98 kg.)
ASU – 10.61 lb. (4.81
kg.)
MXe III – 28 lb. (12.7 kg.)
AX – 39.70 Ib. (18.01 kg.)
ASU II – 14.1 lb. (6.4
kg.)
Operational Environment
Specification
Temperature
Humidity
Max Heat Dissipation
(Fully Loaded)
CXi II – 170 BTUs per hour
MXe III– 750 BTUs per hour
AX – 1024 BTUs per hour
Air Flow
Acoustic Emissions
ASU II – 260 BTUs per
hour
48-Port: 81 BTUs per
hour
46 cubic ft. / min. at maximum output
of fans AX – 110 cubic ft.
_
_
_
Max 50dBA continuous, 75dBA
intermittent (<10% duty cycle)
_
_
_
Conversion factors: One watt is equal to 3.412 BTUs per hour. One ton of refrigeration is equal to 12,000 BTUs per hour or 3.516 Kilowatts,
and 0.75 kilowatt-hour is equal to one ton of refrigeration.
Mitel | 6
System Input Requirements
Specification
ANALOG
SERVICES UNIT
(ASU)
NETWORK
SERVICES UNIT
(NSU)
STREAMLINE
IEC320-C14 Class 1 AC Receptacle
2 AC Receptacles on AX
and MXe III with redundant power
IEC320-C14 Class 1
AC Receptacle
IEC320-C14 Class 1
AC Receptacle
IEC320-C14 Class 1
AC Receptacle
100 – 240 VAC
50 / 60 Hz
100 – 240 VAC
50 / 60 Hz
100 – 240 VAC
50 / 60 Hz
100 – 240 VAC
50 / 60 Hz
CX II / CXi II – 250 W
ASU – 75 W max
NSU (R2) – 20 W
24-Port: 16.5W
MXe III – 200 W
ASU II – 125 W max
NSU – 30 W
48-Port: 22W
90 – 264 VAC
90 – 264 VAC
90 – 264 VAC
90 – 264 VAC
47 – 63 Hz
67 – 63 Hz
67 – 63 Hz
67 – 63 Hz
3300 CONTROLLER
Input / Disconnect
Input Voltage / Frequency
Rating
Input Power
MXe III Expanded – 250 W
AX – 300 W
AC Source
Frequency Range
For more technical specifications on the StreamLine, please refer to the StreamLine Data Sheet at mitel.com/molstreamline.
9
Glossary
ACD
ASU
BRI
BTU
CAS
CCS
CIM
CLASS
DASSII
DID / DDI DNI
DPNSS
DSP
DTMF
FIM
IP
ISDN
LS
MMC
MOH
MSDN
NFAS
Automatic Call Distribution
Analog Services Unit
Basic Rate Interface
British Thermal Unit
Channel Associated Signaling
Common Channel Signaling
Copper Interface Module
Custom Local Access Signaling Services
Digital Access Signaling System #2
Direct Inward Dial / Direct Dial In
Digital Network Interface
Digital Private Network Signaling System
Digital Signal Processor
Dual Tone Multi-Frequency
Fiber Interface Module
Internet Protocol
Integrated Services Digital Network
Loop Start Trunk
MITEL Mezzanine Card
Music on Hold
Mitel Superswitch Digital Network
Non-Facilities Associated Signaling
NSU
OPS
Network Services Unit
Off Premises, long loop analog PBX ports
mitel.com
PRI
Primary Rate Interface, ISDN
QSIG
Q-Signaling Protocol
RSTP
Rapid Spanning Tree Protocol
SIP
Session Initiation Protocol
STP
Spanning Tree Protocol
T38ITU protocol to send FAX transmission
across
IP Networks
VM
Voice Mail
XNET Switched Networking
TRUNKING
GATEWAYA 3300 Controller used specifically to land
PSTN trunks and route them onto a User
Gateway
USER
GATEWAYA 3300 Controller / Server used specifically
to manage and control Telephones.
External traffic is routed via a Trunking
Gateway
3300
CONTROLLERMitel’s telephony platform that runs
Mitel MiVoice Business (formerly Mitel
Communications Director (MCD))
© Copyright 2014, Mitel Networks Corporation. All Rights Reserved. The Mitel word and logo are trademarks of Mitel
Networks Corporation. Any reference to third party trademarks are for reference only and Mitel makes no representation
of ownership of these marks.
6050-16480-123456-SS0715-EN