AC and AC/DC Clamp-on Ammeters Clamp-on meters include models with Temperature and True RMS measurements With Peak Hold captures in-rush currents Common Features: • Maximum AC current of 600A • Measure AC Current, AC/DC Voltage and Resistance • Data Hold “freezes” data in display • 1.25" (33mm) circular jaw opening for large cables (350MCM) • Audible Continuity beeper • Auto power off • Complete with test leads, 9V battery, and belt holster Model 38387 • AC current to 600A • Large 2000 count LCD display Model 38389 • True RMS voltage and current measurements • AC/DC current to 600A • Large 4000 count LCD display • Capacitance measurements • Temperature measurements • Includes temperature probe (-58 to 482°F/-50 to 250°C) Model AC Current: DC Current DC Voltage: AC Voltage: Resistance: Capacitance: Temperature Continuity: Power: Dimensions: Weight: 38387 (Max. Resolution) Basic Accuracy (%rdg+digits) 200.0A, 600A (0.1A) ±(1.5% + 4d) — — 600V (1V) ±(1% + 1d) 600V (1V) ±(1.5% + 4d) 2000ø (1ø) ±(1% + 2d) — — — — Beeper ≤50ø 9V battery 3.1 x 8 x 1.6" (79 x 203 x 41mm) 6.5oz (185g) 38389 (Max. Resolution) Basic Accuracy (%rdg+digits) 400A, 600A (Trms) (100mA) ±(3.0% + 5d) 400A, 600A (100mA) ±(2.5% + 3d) 400mV, 4V, 40V, 400V, 600V (0.1mV) ±(0.5% + 2d) 4V, 40V, 400V, 600V (Trms) (1mV) ±(0.8% + 3d) 400ø, 4kø, 40kø, 400kø, 4Mø, 40Mø (0.1ø) ±(0.8% + 4d) 40nF, 400nF, 4μF, 40μF, 100μF (0.01nF) ±(3.5% + 5d) -4 to 1400°F, -20 to 760°C (1°F/°C) ±(3.0% + 3°F/2°C) Beeper ≤30ø 9V battery 3.1 x 8 x 1.6" (79 x 203 x 41mm) 6.5oz (185g) Ordering Information: 38387 ............AC Clamp Meter 38387-NIST....AC Clamp Meter w/ Calibration Traceable to NIST 38389 ............True RMS AC/DC Clamp Meter 38389-NIST....True RMS AC/DC Clamp Meter w/ Calibration Traceable to NIST 480172 ..........Line Separator www.extech.com Specifications subject to change without notice. 7/23/10 - R2 Copyright © 2007-2010 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form.